Series description: Wilo-Yonos MAXO-D
|
|
- Morgan Johnson
- 7 years ago
- Views:
Transcription
1 ATAC Solutions LTD / 1 / Series description: 1 /, /,5-1 3/, / /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power adjustment. Application Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems. Type key Example: 3/.5-7 Yonos MAXO High-efficiency pump (screw-end or flange-end pump), electronically controlled -D Double pump 3/ Nominal connection diameter.5-7 Nominal delivery head range [m] Special features/product advantages Very high efficiency due to ECM technology LED display for showing the set delivery head Quick and convenient electrical connection with Wilo plug Collective fault signal on all types for assuring system availability Simple installation due to PN /PN 1 combination flanges (with DN 3 to DN 5) Application possible in cooling/air-conditioning systems without ambient temperature limitation Pump housing with cataphoretic coating for preventing corrosion due to condensation formation Double pump for main/standby operation 1 1 Equipment/function Operating modes Δp-c for constant differential pressure Δp-v for variable differential pressure Manual functions Setting the operating mode Setting of pump output (delivery head) Automatic functions Infinitely variable power adjustment according to the operating mode Deblocking function Soft start Integrated full motor protection Signal and display functions Collective fault signal (potential-free NC contact) Fault signal light LED segment display for displaying the delivery head and fault codes Double pump function Main/standby operation: for an automatic fault-actuated switchover, a corresponding switchgear must be provided on-site. Predefined control mode and set delivery head must be identical for both pumps. Equipment Wrench attachment point on pump body (for threaded pipe union pumps) Quick electrical connection with Wilo plug. For the connection of the mains and SSM lines, with integrated strain relief For flange-end pumps: Flange versions Standard version for pumps DN 3 to DN 5: Combination flange PN /1 (flange PN 1 acc. to EN 19-) for counter flanges PN and PN 1 Scope of delivery Pump Incl. washers for flange screws (for nominal connection diameters DN 3 - DN 5) Including installation and operating instructions Accessories Adapter fittings Subject to change without prior notice. 5 Hz EU / 15
2 1 / Duty chart: Duty chart /, /,5-7 5/,5-9 5/,5-1 3/,5-3/, Subject to change without prior notice. 5 Hz EU 13-1 / 15
3 1 / Product list: Type Nominal flange diameter Rated pressure Overall length Mains connection Gross weight Art no. PN / bar l / mm m / kg Yonos MAXO-D 3/,5-7 DN 3 /1 1~3 V, 5/ Hz 1, 1 Yonos MAXO-D 3/,5-11 DN 3 /1 1~3 V, 5/ Hz 1,9 13 Yonos MAXO-D /,5- DN /1 1~3 V, 5/ Hz 19,3 1 Yonos MAXO-D /,5-1 DN /1 5 1~3 V, 5/ Hz, 15 Yonos MAXO-D 5/,5-9 DN 5 /1 1~3 V, 5/ Hz,9 17 Yonos MAXO-D 5/,5-1 DN 5 /1 1~3 V, 5/ Hz,5 1 Subject to change without prior notice. 5 Hz EU / 15
4 1 / Data sheet: 3/,5-7 Pump curves v,, 1, 1,, 7 5 3/,5-7 1~3V - DN 3 m/s p/kpa 7 5 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C Maximum permissible operating pressure P max C /1 bar Δp-c Δp-v 15,, 1, 1, , m m m Q/l/s Pipe connections Flange Combination flange PN/1 (PN 1 flange according to EN 19-) Nominal flange diameter DN 3 Overall length l mm Motor/electronics Energy efficiency index (EEI),7 Electromagnetic compatibility EN 1-3 Emitted interference EN 1--3 Dimension drawing DN 3 Interference resistance EN 1-- Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/ Hz Nominal motor power P 9, W Speed n 1-37 rpm 7 1 Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials Pump housing Impeller Pump shaft Bearing Grey cast iron (EN-GJL-5) Plastic (PPE - 3% GF) Stainless steel (XCr13) Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU 13-1 / 15
5 1 / Data sheet: 3/,5-7 Dimension drawing, flange Ø 1 Ø 1 Ø 9 Ø 7 DN 3 Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Information for order placements Make Wilo Type Yonos MAXO-D 3/,5-7 Art no. 1 Weight approx. m 1 kg x Ø1 x Ø19 Terminal diagram 1~ 3 V, 5/ Hz 3~3 V, 5/ Hz L N PE SSM L1 L3 PE SSM L L3 SSM: L1 L Collective fault signal (NC contact according to VDI 31, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Subject to change without prior notice. 5 Hz EU / 15
6 1 / Data sheet: 3/,5-11 Pump curves v 1 3 3/,5-11 1~3V - DN 3 m/s p/kpa Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max /1 bar Δp-c 3 Δp-v , 1m 1 1 m Q/l/s Pipe connections Flange Combination flange PN/1 (PN 1 flange according to EN 19-) Nominal flange diameter DN 3 Overall length l mm Motor/electronics Energy efficiency index (EEI),7 Electromagnetic compatibility EN 1-3 Emitted interference EN 1--3 Dimension drawing DN 3 Interference resistance EN 1-- Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/ Hz Nominal motor power P, W Speed n 1 - rpm 57 Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials Pump housing Impeller Pump shaft Bearing Grey cast iron (EN-GJL-5) Plastic (PPS - % GF) Stainless steel (XCr13) Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU 13-1 / 15
7 1 / Data sheet: 3/,5-11 Dimension drawing, flange Ø 1 Ø 1 Ø 9 Ø 7 DN 3 Minimum suction head at 5 / 95 / 11 C 3 / 1 / 1 m Information for order placements Make Wilo Type Yonos MAXO-D 3/,5-11 Art no. 13 Weight approx. m 17 kg x Ø1 x Ø19 Terminal diagram 1~ 3 V, 5/ Hz 3~3 V, 5/ Hz L N PE SSM L1 L3 PE SSM L L3 SSM: L1 L Collective fault signal (NC contact according to VDI 31, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Subject to change without prior notice. 5 Hz EU / 15
8 1 / Data sheet: /,5- Pump curves v,5 1, 1,5,,5 3, /,5-1~3V - DN m/s p/kpa Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max /1 bar Δp-c Δp-v Q/l/s, 1m m 1 1 Pipe connections Flange Combination flange PN/1 (PN 1 flange according to EN 19-) Nominal flange diameter DN Overall length l mm Motor/electronics Energy efficiency index (EEI),7 Electromagnetic compatibility EN Emitted interference EN 1--3 Dimension drawing DN Interference resistance EN 1-- Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/ Hz Nominal motor power P, W Speed n 1 - rpm Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials Pump housing Impeller Pump shaft Bearing Grey cast iron (EN-GJL-5) Plastic (PPS - % GF) Stainless steel (XCr13) Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU 13-1 / 15
9 1 / Data sheet: /,5- Dimension drawing, flange Ø 15 Ø 11 Ø 1 Ø DN Minimum suction head at 5 / 95 / 11 C 3 / 1 / 1 m Information for order placements Make Wilo Type Yonos MAXO-D /,5- Art no. 1 Weight approx. m 1 kg x Ø1 x Ø19 Terminal diagram 1~ 3 V, 5/ Hz 3~3 V, 5/ Hz L N PE SSM L1 L3 PE SSM L L3 SSM: L1 L Collective fault signal (NC contact according to VDI 31, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Subject to change without prior notice. 5 Hz EU / 15
10 1 / Data sheet: /,5-1 Pump curves 1 1 Δp-c v Δp-v /,5-1 1~3V - DN m 11m, 1m 11m 1m 1m 1m m m/s 1 1 Q/l/s p/kpa Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C Maximum permissible operating pressure Pipe connections Flange P max C /1 bar Combination flange PN/1 (PN 1 flange according to EN 19-) Nominal flange diameter DN Overall length l 5 mm Motor/electronics Energy efficiency index (EEI),7 Electromagnetic compatibility EN Emitted interference EN 1--3 Dimension drawing DN Interference resistance EN 1-- Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/ Hz Nominal motor power P 35, W Speed n 95-5 rpm 3 Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials Pump housing Impeller Pump shaft Bearing Grey cast iron (EN-GJL-5) Plastic (PPS - % GF) Stainless steel (XCr13) Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 15
11 1 / Data sheet: /,5-1 Dimension drawing, flange Ø 15 Ø 11 Ø 1 Ø DN Minimum suction head at 5 / 95 / 11 C 5 / 1 / 1 m Information for order placements Make Wilo Type Yonos MAXO-D /,5-1 Art no. 15 Weight approx. m kg x Ø1 x Ø19 Terminal diagram 1~ 3 V, 5/ Hz 3~3 V, 5/ Hz L N PE SSM L1 L3 PE SSM L L3 SSM: L1 L Collective fault signal (NC contact according to VDI 31, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Subject to change without prior notice. 5 Hz EU / 15
12 1 / Data sheet: 5/,5-9 Pump curves v,5 1, 1,5,,5 3, 5/,5-9 1~3V - DN 5 m/s p/kpa Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max /1 bar Q/l/s Δp-c Pipe connections Flange Combination flange PN/1 (PN 1 flange according to EN 19-) Δp-v 1m 1 1, m 1 1 Nominal flange diameter DN 5 Overall length l mm Motor/electronics Energy efficiency index (EEI),7 Electromagnetic compatibility EN 1-3 Emitted interference EN 1--3 Dimension drawing DN 5 Interference resistance EN 1-- Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/ Hz Nominal motor power P 35, W Speed n 95 - rpm 33 Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials Pump housing Impeller Pump shaft Bearing Grey cast iron (EN-GJL-5) Plastic (PPS - % GF) Stainless steel (XCr13) Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 15
13 1 / Data sheet: 5/,5-9 Dimension drawing, flange Ø 15 Ø 15 Ø 11 Ø 99 DN 5 Minimum suction head at 5 / 95 / 11 C 5 / 1 / 1 m Information for order placements Make Wilo Type Yonos MAXO-D 5/,5-9 Art no. 17 Weight approx. m kg x Ø1 x Ø19 Terminal diagram 1~ 3 V, 5/ Hz 3~3 V, 5/ Hz L N PE SSM L1 L3 PE SSM L L3 SSM: L1 L Collective fault signal (NC contact according to VDI 31, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Subject to change without prior notice. 5 Hz EU / 15
14 1 / Data sheet: 5/,5-1 Pump curves 1 v,5 1, 1,5,,5 3, 5/,5-1 1~3V - DN 5 m/s p/kpa 1 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max /1 bar Q/l/s Δp-c Δp-v m 1m, 11m 1m 1m m Pipe connections Flange Combination flange PN/1 (PN 1 flange according to EN 19-) Nominal flange diameter DN 5 Overall length l mm Motor/electronics Energy efficiency index (EEI),7 Electromagnetic compatibility EN Emitted interference EN 1--3 Dimension drawing DN 5 Interference resistance EN 1-- Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/ Hz Nominal motor power P 5, W Speed n 95 - rpm 33 Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials Pump housing Impeller Pump shaft Bearing Grey cast iron (EN-GJL-5) Plastic (PPS - % GF) Stainless steel (XCr13) Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 15
15 1 / Data sheet: 5/,5-1 Dimension drawing, flange Ø 15 Ø 15 Ø 11 Ø 99 DN 5 Minimum suction head at 5 / 95 / 11 C 5 / 1 / 1 m Information for order placements Make Wilo Type Yonos MAXO-D 5/,5-1 Art no. 1 Weight approx. m kg x Ø1 x Ø19 Terminal diagram 1~ 3 V, 5/ Hz 3~3 V, 5/ Hz L N PE SSM L1 L3 PE SSM L L3 SSM: L1 L Collective fault signal (NC contact according to VDI 31, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Subject to change without prior notice. 5 Hz EU / 15
Series description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
More informationSeries description: Wilo-Star-Z
H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationCatalogue Wilo- Stratos PARA
Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos
More information1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]
Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF
More informationSeries description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
More informationMultistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationButterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationFlow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationINLINE SD-PUMPS WITH IEC-STANDARD MOTOR
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More information2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationSubmittal Data Sheet Wilo IPL - Inline Centrifugal Circulators
Wilo IPL 1.5 175 RPM Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM IPL 1.5-1/5-6Hz 1,75 ( Pole) 6 1 H[ft] H[m] Wilo-IPL 1.5-1/5-175
More information2- and 3-port valves with flanged connections, PN 10
4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey
More informationHydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationHeating, Air-conditioning, Cooling
Catalogue Building Services Heating, Air-conditioning, Cooling Pumps, pump systems and accessories for heating, secondary hot water, air-conditioning and cooling International edition 2011/2012-50 Hz APPLIES
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationHose and Tube Fittings Series 1-3
Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationProduct Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz
Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,
More informationSafety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationOperating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationSIGMA GROUP a. s. Divize průmyslová čerpadla
SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationVertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
More informationSeries 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
More informationType 3353 Angle Seat Valve
Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationMFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationMEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationARI-ASTRA / ASTRA Plus Combinend flow regulating valve
ARI-ASTRA - Free of maintenance combinend flow regulating valve - soft sealed (to 120 C) ARI-ASTRA Plus - Free of maintenance combinend flow regulating valve (to 175 C resp. 350 C) ARI-ASTRA / ASTRA Plus
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationOEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationNIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
More informationInstructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More information4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
More informationGRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps
GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance
More informationAMTRON E-30 Compact heat and cooling meter
AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationRTD Temperature Probe for the Food/Pharmaceutical Industry
sales@jumo.co.uk Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationBM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
More informationO-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationVM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz
VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,
More information50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod.
/ Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev ev.a.a Ed./ ecocirc BASIC SERIES INSTALLA ALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks
More informationSISTO-16TWA/HWA/DLU. Type Series Booklet
Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationSelf-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
More informationSimple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos. Information for installers
Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos Information for installers 2 ErP Directive Everyone's talking about saving electricity We take action Advantages
More informationSJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationdp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationLaing industrial pumps
Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...
More informationCORONA E / FLYPPER ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationPneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a
Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a Application Tight-closing, double eccentric butterfly valve for process engineering and plants with industrial
More informationGrey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6
Bimetallic steam trap CONA B Bimetallic steam trap Bimetallic steam trap PN16 - with flanges (Fig. 600...1) - union with butt weld ends (Fig. 600...5) Grey cast iron Fig. 600 Page 2 Bimetallic steam trap
More informationBall valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationSITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationPumps n Valves n Service. The right partner for your project. Heating, ventilation and air-conditioning
Pumps n Valves n Service The right partner for your project. Heating, ventilation and air-conditioning 02 Introduction Always the right solution It is not only large projects that place high demands on
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More information