Microwave Multiplexer Module



Similar documents
Agilent Test Solutions for Multiport and Balanced Devices

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent 8753ET/8753ES Network Analyzers

Agilent Measuring Noninsertable Devices

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent E5063A ENA Series Network Analyzer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent Technologies 1670G Series (Option 004) Pattern Generator Specifications and Characteristics

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Agilent P940xA/C Solid State PIN Diode Switches

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Agilent 4338B Milliohm Meter

Agilent 8720 Family Microwave Vector Network Analyzers

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

R&S SMZ Frequency Multiplier Specifications

CREATING YOUR OWN RF SWITCHING SYSTEM

Agilent U2000 Series USB Power Sensors

The Next Generation in Automated Oscilloscope Test

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Using Xbee in Serial Communication

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

HP 8970B Option 020. Service Manual Supplement

Agilent 4339B/4349B High Resistance Meters

Applying Error Correction to Network Analyzer Measurements. Application Note Table of Contents. Page

Bluetooth HC-06 with serial port module Easy guide

RC-1SP4T-A18. Key Features. Mini-Circuits P.O. Box 35166, Brooklyn, NY (718)

2. The Vector Network Analyzer

Byonics Micro Trak 1000 High Altitude Balloon Tracker

Agilent U2000 Series USB Power Sensors

Agilent E5100A Network Analyzer

SYSTEM 45. C R H Electronics Design

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Agilent 87421A/87422A Power Supply

Experiment 7: Familiarization with the Network Analyzer

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

PCI Express Right Angle Connector System

Application Guide to RF Coaxial Connectors and Cables

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Telephone- and leased line modem for industrial applications TD-36

Compact EGC Amplifier Model 93251

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Interface. Displaying Transactions

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

LDG DTS-4/4R Desktop Coaxial Switch / Remote

S a t S e r v i c e Gesellschaft für Kommunikationssysteme mbh

HIGH RELIABILITY POWER SUPPLY TESTING

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

DGM1D Controller + Contact less Smartcard Reader

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Keysight Technologies RF and Microwave Test Accessories

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

Bluetooth UART/RS232 Module

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Switch Selection Guide

W1 Connector W1 Adapter W1 Termination

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

.062 [1.57] Commercial Pin and Socket Connectors

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

Regards from the Team at Rheology Solutions.

S-series Mass Connection Solutions

Transponder for GainMaker Amplifiers

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

JDSU PathTrak. HCU200 Install User s Guide

SmartBlock Power and Energy Monitor With Rogowski Coil (di/dt) Support HE579ACM302

EDI Distributor Control Interface Wiring and Setup Instructions

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

BROADBAND MICROWAVE COMPONENTS & TEST EQUIPMENT

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

Agilent U2000 Series USB Power Sensors

Impedance 50 (75 connectors via adapters)

E5092A Configurable Multiport Test Set

SYSTEM 4C. C R H Electronics Design

Chapter 5 Cubix XP4 Blade Server

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Balun Parameter Definitions & Measurement May 2004

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

To Purchase This Item, Visit BMI Gaming Operation Manual

Agilent N2X Layer 2 MPLS VPN Emulation Software

Agilent E7475A GSM Based Drive-Test System Configuration Guide

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Agilent RouterTester. E7864A Technical Datasheet. Powered by QA Robot Technology. Complete MPLS Protocol Test Software MPLS Protocol Test Software

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Rack mounted telephone- and leased line modem for industrial applications

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

HP 8590 C/E/L/Q and EM Series Spectrum Analyzers and Accessories Configuration Guide

802.11ac Power Measurement and Timing Analysis

MASW T. HMIC TM PIN Diode SP2T 13 Watt Switch for TD-SCDMA Applications. Features. Functional Diagram (TOP VIEW)

PCS300 Universal IP Reporting Module V1.0

Transcription:

Microwave Multiplexer Module Form Drive s K90 OM K90 OM K90 OM Agilent 44476A Switching signals from D to 8 GHz Triple -to- microwave multiplexers N N N Drive Jumpers W W W HP876B HP876B HP876B L90 V TO DRIVE JUMPERS () 906 Microwave Driver Module The 44476A includes three independent SPDT 50 Ω coaxial relays with excellent electrical performance from D to 8 GHz. For general-purpose microwave N * TE: Terminal designations inside the dashed boxes refer to the HP876B only. Module panel designators outside the dashed boxes are those silkscreenedon the HP44476A panel. Any reference in this manual to a port refers to the module panel designators. MODULE* PANEL DESIGNATORS N N = PORT = PORT = RMALLY OPEN N = RMALLY LOSED = OMMON hannel 00 hannel 0 hannel 0 switching applications, the module can be used to switch separate signal sources for a multi-band receiver/transmitter testing application. The mm SMA connector on the module edge simplifies wiring. Specifications Input haracteristics Frequency Range: haracteristic Impedance: Input Power Rating: (Also less than ± 7 VD) Repeatability (after 0 6 operation): onnector: A Isolation / Performance D to 8 GHz 50 Ω W average 00 W peak 0.0 db SMA Isolation: D-8 GHz >90 db Insertion Loss: D- GHz <0.5 db D-8 GHz <0.50 db VSWR D- GHz <.5 db ( mm SMA): D-.4 GHz <.5 db D-8.0 GHz <.40 db With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 4 55 5 fax +49 4 5 066 Feldchen 6-4 D-5070 Aachen Germany Form Drive s K90 OM K90 OM K90 OM Agilent 44476B N N N Drive Jumpers W W USER INSTALLED MIROWAVE SWITH USER INSTALLED MIROWAVE SWITH HANNEL 0 AVAILABLE BUT T USED hannel 00 hannel 0 Supporting varieties of microwave coaxial relays Two set mounting holes for coaxial relays The 44476B brings multi-port 50/75 Ω coaxial switching flexibility to your test system. It has two set mounting panels, so any two Agilent 876XX coaxial switches can be mounted. The coaxial switches come in three-, four-, and five-port configurations. This flexibility allows you to use the different switches for a variety of applications, constructing transfer switches, switch matrices and more. Using the 876XX in conjunction with the 44476B allows you to extend your automated three-port switching to 6.5 GHz. oaxial relays must be ordered separately when using with this module. The coaxial switches that can be used are listed below. Option 0 designates the switches for a coil voltage of 5 VD. oaxial Switch Port Frequency 876A/Option 0 D to 4 GHz 876B/Option 0 D to 8 GHz 876/Option 0 D to 6.5 GHz 876F/Option 0 D to 4 GHz 876B/Option 0 4 D to 8 GHz 876/Option 0 4 D to 6.5 GHz 8764B/Option 0 5 D to 8 GHz 8764/Option 0 5 D to 6.5 GHz Note: For details of Agilent 876XX specifications, please refer to publication number 5968-44. V L90 TO DRIVE JUMPERS () 906 5 Artisan Scientific - Quality Instrumentation... Guaranteed (888) 88-SOURE www.artisan-scientific.com

Agilent E69A Microwave Switch Driver Data Sheet -Slot, B-size, register based Signal switching from dc to 6.5 GHz Drive three internal 50 Ω terminated switches Drive two additional external switches Select internal or use external energizing voltages Use equivalent switches of other manufacturers Agilent E69A Description The Agilent E69A Microwave Switch Driver is a B-size, -slot, register-based VXI module. It provides room for you to install up to three 876B/, 876B/, and 8764B/ (- port, 4-port, and 5-port) series of microwave switches to match your application needs up to 5.6 GHz. These switches must be ordered separately. The E69A can power and control a total of five switches, two of which must be mounted externally with ribbon cable and DIN connector. Additionally, you can select internal energizing voltages + 5 and + Vdc, or supply your own external energizing voltage up to 45 Vdc if more power is needed. Refer to the Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable. Other Manufacturers These manufacturers supply equivalent switches that can be installed in the E69A: K&L Microwave Inc. Dynatech Microwave Tech Inc. RL Electronics Inc. Switches can be used if they require less than 4 V, draw less than A per switch, and are of the split-coil (separate for each contact) design. Maximum current also depends on the mainframe or external supply capacity. The following coaxial switch series will not function in the E69A microwave switch module, because the switch coils are not split: Agilent 876, 8766, 8767, 8768, and 8769. PDFINFO H 5 5 9 7-0

Product Specifications Microwave Switches (+ 5 V, 50 Ω) for mounting in the E68/69A Microwave Switch Modules Switch: B or 876B or 876 B or 876B or 876 B or 8764B or 8764 Frequency: dc to 8 GHz dc to 6.5 GHz dc to 8 GHz dc to 6.5 GHz dc to 8 GHz dc to 6.5 GHz Ports: 4 4 5 5 Internal termination: Terminated Terminated Terminated (one port) Terminated (one port) Unterminated Unterminated Insertion loss (db): SWR (into termination or through line): <0.0 to GHz <0.5 to 4 GHz <0.50 to 8 GHz <. to GHz <. to 4 GHz <. to 8 GHz <0.0 to GHz <0.50 to 8 GHz <.5 to 6.5 GHz <.5 to GHz <.5 to.4 GHz <.40 to 8 GHz <.8 to 6.5 GHz Isolation (db): >90 to 8 GHz >90 to 8 GHz >50 to 6.5 GHz Life and 0 6 cycles 0 6 cycles repeatability 0.0 db 0.0 db (typical): Power (peak power is nonswitching): Watt average 00 Watts peak Watt average 00 Watts peak <0.0 to GHz <0.50 to 8 GHz <. to GHz <. to 4 GHz <. to 8 GHz <0.0 to GHz <0.50 to 8 GHz <.5 to GHz <.5 to.4 GHz <.40 to 8 GHz <.8 to 6.5 GHz >90 to 8 GHz >90 to 8 GHz >50 to 6.5 GHz 0 6 cycles 0 6 cycles 0.0 db 0.0 db Watt average 00 Watts peak Watt average 00 Watts peak <0.0 to GHz <0.50 to 8 GHz <.5 to 6.5 GHz Into Termination: n/a Through Line: same as Agilent 876B <0.0 to GHz <0.50 to 8 GHz <.5 to 6.5 GHz Into Termination: n/a Through Line: same as Agilent 876 >90 to 8 GHz >90 to 8 GHz >50 to 6.5 GHz 0 6 cycles 0 6 cycles 0.0 db 0.0 db Watt average 00 Watts peak Watt average 00 Watts peak Switching speed: 0 ms 0 ms 0 ms 0 ms 0 ms 0 ms RF connectors: SMA (female).5 mm (female) SMA (female).5 mm (female) SMA (female).5 mm (female) Switching dwell time: 5 ms 5 ms 5 ms 5 ms 5 ms 5 ms Driver output voltage ( A max per switch): 5 V or V 5 V or V 5 V or V 5 V or V 5 V or V 5 V or V Maximum external energizing voltage: 0 V 0 V 0 V 0 V 0 V 0 V With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 4 55 5 fax +49 4 5 066 Feldchen 6-4 D-5070 Aachen Germany PDFINFO H 5 5 9 7-0

General Specifications VXI haracteristics VXI device type: Register based, A6, slave only Size: B Slots: onnectors: P Shared memory: None VXI busses: None -size compatibility: Requires E40 Instrument Drivers See the Website (http://www.agilent.com/find/ inst_drivers) for driver availability and downloading. ommand module firmware: Downloadable ommand module firmware rev: A.0 I-SPI Win.: I-SPI Series 700: -SPI LynxOS: -SPI Series 700: Panel Drivers: VXIplug&play Win No VXIplug&play Win 95/NT VXIplug&play HP-UX No Ordering Information Description Product No. Microwave Switch Driver E69A Yr. Retn. to Agilent to Yr. OnSite Warr. E69A W0 oaxial SPDT Switch, dc-8 GHz 876B 5 V Solenoids Instead of 4 V Solenoids 876B 0 ommercial al. ertificate w/test Data 876B UK6 ertificate of alibration 876B UKS oaxial SPDT Switch, dc-6.5 GHz; 50 Ω 876 5 V Solenoids Instead of 4 V Solenoids 876 0 ommercial al. ertificate w/test Data 876 UK6 ertificate of alibration 876 UKS Switch, oaxial, Transfer Switch, 4 Port 876B 5 Volt Solenoids 876B 0 ommercial al. ertificate w/test Data 876B UK6 ertificate of alibration 876B UKS Switch, oaxial, Transfer Switch, 4 Port 876 5 Volt Solenoids 876 0 ommercial al. ertificate w/test Data 876 UK6 ertificate of alibration 876 UKS Switch, oaxial, Signal Reversal, 5 Port 8764B 5 Volt Solenoids 8764B 0 ommercial al. ertificate w/test Data 8764B UK6 ertificate of alibration 8764B UKS Switch, oaxial, Signal Reversal, 5 Port 8764 5 Volt Solenoids 8764 0 ommercial al. ertificate w/test Data 8764 UK6 ertificate of alibration 8764 UKS Drive able, 40GHz Attn 4pin DIP 6in 764D Module urrent I PM V: 0. 0 + V: 0 0 V: 0 0 +4 V: 0 0 4 V: 0 0 5. V: 0 0 V: 0 0 I DM ooling/slot Watts/slot: 5.00 ΔP mm H O: 0.08 Air Flow liter/s: 0.50 Agilent E68A/E69A/70A Drive ircuits Agilent E69A Switch onfigurations PDFINFO H 5 5 9 7-0

Related Literature 000 Test System and VXI atalog D-ROM, Agilent Pub. No. 5980-008E (detailed specifications for VXI products) 000 Test System and VXI atalog, Agilent Pub. No. 5980-007E (overview of VXI products ) 998 Test System and VXI Products Data Book, Agilent Pub. No. 5966-8E Online Internet access for Agilent product information, services and support www.agilent.com/find/tmdir VXI product information www.agilent.com/find/vxi Defense Electronics Applications www.agilent.com/find/defense_ate VXI hannel Partners www.agilent.com/find/vxichanpart HP VEE Application Website www.agilent.com/find/vee Data Acquisition and ontrol Website www.agilent.com/find/data_acq Instrument Driver Downloads www.agilent.com/find/inst_drivers Electronics Manufacturing Test Solutions www.agilent.com/go/manufacturing Get assistance with all your test and measurement needs at www.agilent.com/find/assist or check your local phone book for the Agilent office near you. test and measurement service/support commitment Agilent strives to maximize the value our test and measurement products give you, while minimizing your risk and service/support problems. We work to ensure that each product is realistically described in the literature, meets its stated performance and functionality, has a clearly stated global warranty, and is supported at least five years beyond its production life. Our extensive selfhelp tools include many online resources (www.agilent.com). Experienced Agilent test engineers throughout the world offer practical recommendations for product evaluation and selection. After you purchase an Agilent product, they can provide no-charge assistance with operation verification and basic measurement setups for advertised capabilities. To enhance the features, performance, and flexibility of your test and measurement products and to help you solve application challenges Agilent offers free or extra-cost product options and upgrades, and sell expert engineering, calibration, and other consulting services. Phone and fax United States: (tel) 800 45 4844 anada: anada Inc. (tel) 877 894 444 Europe: Test & Measurement European Marketing Organisation (tel) ( 0) 547 000 Japan: Japan Ltd. (tel) (8) 46 56 78 (fax) (8) 46 56 7840 Latin America: Latin American Region Headquarters, U.S.A. (tel) (05) 67 445 (fax) (05) 67 486 Australia/New Zealand: Australia Pty Ltd. (tel) 800 69 485 (Australia) (fax) (6 ) 97 0749 (tel) 0 800 78 78 (New Zealand) (fax) (64 4) 80 688 Asia Pacific:, Hong Kong (tel) (85) 97-7777 (fax) (85) 506-984 Data Subject to hange 000 Printed in the U.S.A. 04/000 Publication No.: 5965-5597E PDFINFO H 5 5 9 7-0 4