A program for phase identification using diffractograms obtained from TEM structure images



Similar documents
Crystal Structure Determination I

Diffraction Course Series 2015

This is an author-deposited version published in: Handle ID:.

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye

Relevant Reading for this Lecture... Pages

Chapters 2 and 6 in Waseda. Lesson 8 Lattice Planes and Directions. Suggested Reading

Physics 441/2: Transmission Electron Microscope

Scanning Electron Microscopy: an overview on application and perspective

" {h k l } lop x odl. ORxOS. (2) Determine the interplanar angle between these two planes:

Lenses and Apertures of A TEM

Lec 17: Dislocation Geometry and Fabric Production 1. Crystal Geometry

Crystal Structure of High Temperature Superconductors. Marie Nelson East Orange Campus High School NJIT Professor: Trevor Tyson

Characterization of excited states of 15 N through 14 C(p,p) 14 C using polarized proton beam

Introduction to X-Ray Powder Diffraction Data Analysis

X-ray Diffraction (XRD)

LMB Crystallography Course, Crystals, Symmetry and Space Groups Andrew Leslie

Tools for Electron Diffraction Pattern Simulation for the Powder Diffraction File

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry 2009

Basics of X-ray diffraction: From symmetry to structure determination

Experiment: Crystal Structure Analysis in Engineering Materials

Tuesday 20 May 2014 Morning

X-ray thin-film measurement techniques

X-ray Powder Diffraction Pattern Indexing for Pharmaceutical Applications

Chapter 14 High Resolution TEM

Spatial location in 360 of reference points over an object by using stereo vision

Introduction to Powder X-Ray Diffraction History Basic Principles

Image Processing of Atomic Resolution Transmission Electron Microscope Images

rotation,, axis of rotoinversion,, center of symmetry, and mirror planes can be

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012

X-ray Diffraction and EBSD

ISOLATION OF MAGNETIC NANOPARTICLES FROM PACHYCONDYLA MARGINATA ANTS

RAPIDLY SOLIDIFIED COPPER ALLOYS RIBBONS

The Basics of Scanning Electron Microscopy

Refinement of magnetic domains in FeTbGe 2 O 7

View of ΣIGMA TM (Ref. 1)

Chapter Outline. How do atoms arrange themselves to form solids?

Ionic Bonding Pauling s Rules and the Bond Valence Method

Física Computacional Conceptos de programación.

PHOTOGRAMMETRIC TECHNIQUES FOR MEASUREMENTS IN WOODWORKING INDUSTRY

Solid State Theory Physics 545

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Introduction to microstructure

Usage of AFM, SEM and TEM for the research of carbon nanotubes

PHYSIOLOGY AND MAINTENANCE Vol. II - On The Determination of Enzyme Structure, Function, and Mechanism - Glumoff T.

A reinterpretation of the phase transitions in Na 2 CO 3

Chapter 7: Basics of X-ray Diffraction


Phase Characterization of TiO 2 Powder by XRD and TEM

Reproducible Fabrication of Scanning Tunneling Microscope Tips

Electron Microscopy SEM and TEM

Chapter types of materials- amorphous, crystalline, and polycrystalline. 5. Same as #3 for the ceramic and diamond crystal structures.

Phase determination methods in macromolecular X- ray Crystallography

Unit 12 Practice Test

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

A comparative study of two models for the seismic analysis of buildings

vii TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENT ABSTRACT ABSTRAK

Nanoscience Course Descriptions

Guide to Understanding X-ray Crystallography

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

X-ray diffraction techniques for thin films

We shall first regard the dense sphere packing model Draw a two dimensional pattern of dense packing spheres. Identify the twodimensional

Lösungen Übung Verformung

Susana Sanduvete-Chaves, Salvador Chacón-Moscoso, Milagrosa Sánchez- Martín y José Antonio Pérez-Gil ( )

CONCEPTUAL DESIGN OF A HYBRID ROBOT

NATIONAL CENTRE FOR PARTICLE, ASTROPARTICLE AND NUCLEAR PHYSICS

Crystal Optics of Visible Light

Laue lens for Nuclear Medicine

Introduction to acoustic imaging

Atomic Force Microscope and Magnetic Force Microscope Background Information

DIFFERENTIATIONS OF OBJECTS IN DIFFUSE DATABASES DIFERENCIACIONES DE OBJETOS EN BASES DE DATOS DIFUSAS

Structure Factors

Technology White Papers nr. 13 Paul Holister Cristina Román Vas Tim Harper

Computer Vision for Quality Control in Latin American Food Industry, A Case Study

POWDER X-RAY DIFFRACTION: STRUCTURAL DETERMINATION OF ALKALI HALIDE SALTS

CHEM 1411 Chapter 5 Homework Answers

An Efficient Load Balancing Technology in CDN

Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope

Metrics of resolution and performance for CD-SEMs

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Plate waves in phononic crystals slabs

The atomic packing factor is defined as the ratio of sphere volume to the total unit cell volume, or APF = V S V C. = 2(sphere volume) = 2 = V C = 4R

X-RAY DIFFRACTION IMAGING AS A TOOL OF MESOSTRUCTURE ANALYSIS

Scanning Electron Microscopy Primer

Supporting Information

Explain the ionic bonds, covalent bonds and metallic bonds and give one example for each type of bonds.

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Powers of Two in Generalized Fibonacci Sequences

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Principles & Practice of Electron Diffraction

DNA NANOWIRES USING NANOPARTICLES ECG653 Project Report submitted by GOPI

The Unshifted Atom-A Simpler Method of Deriving Vibrational Modes of Molecular Symmetries

Mg 2 FeH 6 -BASED NANOCOMPOSITES WITH HIGH CAPACITY OF HYDROGEN STORAGE PROCESSED BY REACTIVE MILLING

Confocal profiling of grooves and ridges with circular section using the divided aperture technique

JOURNAL INTEGRATED CIRCUITS AND SYSTEMS, VOL 1, NO. 3, JULY

X-Ray Diffraction: A Comprehensive Explanation for Multipurpose Research

Supporting Information

Characterization and Properties of Carbon Nanotubes

Fast Varifocal Lenses Based on KTa 1-x Nb x O 3 (KTN) Single Crystals

Defects Introduction. Bonding + Structure + Defects. Properties

Transcription:

INVESTIGACIÓN Revista Mexicana de Física 59 (2013) 102 106 MARCH APRIL 2013 A program for phase identification using diffractograms obtained from TEM structure images R. Galicia a, R. Herrera a,, J. L. Rius b, C. Zorrilla a, and A. Gómez a a Departamento de Materia Condensada, Instituto de Física, Universidad Nacional Autónoma de México, 20-364, México, 01000, D.F., México. e-mail:rherrera@fisica.unam.mx b Departamento de Sistemas Complejos, Instituto de Física, Universidad Nacional Autónoma de México, 20-364, México, 01000, D.F., México. Recibido el 16 de agosto de 2012; aceptado el 8 de noviembre de 2012 In this work a computer program for the indexing of diffractograms is presented. The diffractograms are obtained by means of a discrete Fourier transform from high resolution electron microscope images. The program requires the use of x-ray diffraction data files together with a fast Fourier transform program, for this purpose we used the Digital Micrograph software. Keywords: Electron microscopy; X-ray diffraction; difractograms; indexing. Se presenta un programa de cómputo que ayuda a identificar los planos cristalográficos (indexar difractogramas) que aparecen al aplicar la Transformada Rápida de Fourier (FFT) a una imagen digital de alta resolución obtenida con un microscopio electrónico de transmisión de alta resolución. El programa requiere el uso de los archivos de Rayos X de uso común y de un programa que obtenga la FFT, para este caso se utiliza el software de Digital Micrograph. Descriptores: Microscopia electrónica; rayos X; difractogramas; indexación. PACS: 61.14.Dc; 61.68.+n 1. Introduction Diffraction is doubtless one of the most powerful techniques for the elucidation of condensed matter structure. While x- ray, neutron, and electron diffraction all provide basic information on symmetry and atomic arrangements, electron diffraction is unique in its ability to identify nanometric crystal phases within a matrix or on a substrate. The atomic spacing information in a high resolution TEM image of a crystal can be extracted by taking the Fourier transform of the image. This yields a diffractogram of spots (points) in an arrangement similar to an electron diffraction pattern of the same specimen; however, the diffractogram can be obtained from regions of specimen on the order of a nanometer rather than the micrometer typical of conventional selected area electron diffraction. To identify a small crystalline phase, the specimen is usually tilted so that the electron beam is directed along a major zone axis in the crystal, thus yielding a symmetrical array of diffraction spots. The electron diffraction pattern provides the interplanar spacings of the (hkl) planes belonging to a given [uvw] zone. Indexing consists of assigning the specific (hkl) indices to the various spots. Measured distances from the diffractogram center (that corresponds to the transmitted beam in the diffraction pattern) to the (hkl) diffraction spots yield the d hkl -spacings for each spot in the electron diffraction pattern or in the Fourier transform of the lattice image or structure image (the diffractogram). The set of d-spacings obtained in this way and the angles between pairs of spots allow identification of the unknown phase by comparison with structures of known substances. Once the structure of a phase is known, the major task is to index the spots in the diffraction pattern or diffractogram. A survey of related procedures for phase identification and diffraction spot indexing can be found in the Refs. 1 to 6. This article presents a program for identifying phases using the diffractogram derived from high-resolution TEM structure images that show atomic columns. The program is based on the zone axis method of crystallography [6], and it compares the diffraction pattern data from the unknown sample with that of known compounds and indexes the unknown spots when the best fit is obtained. This article describes the steps involved in the operation of the software and gives a practical example. It is important to stress that we work with actual electron micrographs and not with simulations obtained, for example, with JEMS or related programs. In the diffractogram the spots are identified; the rest of the spatial frequencies are not used. 2. Program Description A program for the analysis of a diffractogram, obtained from the high-resolution image by means of the Fast Fourier transform (FFT) algorithm, has been developed following a standard architecture in which the Front End (Client), requests services from the Back-end (server). The graphical user interface and the operational algorithm have been programmed under Delphi 6 (in the client), a platform providing a development environment integrated to the Windows environment. It is an object-oriented language that has considerable support for databases.

A PROGRAM FOR PHASE IDENTIFICATION USING DIFFRACTOGRAMS OBTAINED FROM TEM STRUCTURE IMAGES The services are requested from an SQL (Structured Query Language) Server 2005 Express data base, a product freely distributed, designed as a data base platform that is easy to use where one has stored procedures (SQL statements) that will be called by client procedures (Delphi). For image analysis, it is necessary to know some of the parameters involved in image acquisition via DigitalMicrograph: the electron wavelength, camera length, accelerating voltage, magnification of the image, etc. All the images were obtained with a JEOL FEG 2010 microscope equipped with image capture software. The program can be obtained freely from the authors. Although at present the program uses the DigitalMicrograph software, it is possible to use other platforms such as Matlab for the purpose of calculating the Fourier transforms.. 3. User Screens The program contains five screens. In the first one (Fig. 1), the user keys in the data provided by the DigitalMicrograph (DM) program in order to calculate the reference parameters such as the magnitudes of vectors defining the positions (with respect to the coordinate origin) of each of the spots in the F IGURE 1. First screen used for data identification and input. F IGURE 2. Second screen used for the input of x-ray crystallographic data for various materials. 103 diffractogram. The program requires at least two points and the angles between the points relative to the center spot. The second screen (Fig. 2) introduces the lattice parameter data taken from the X-ray crystallographic data tables relevant to the sample under consideration. These data are stored in a database for future use unless the user deletes them. In the third screen (Fig. 3), the actual calculations are performed. The user selects the X-ray crystallographic database and gives a tolerance for the maximum error allowed between calculated angles and measured ones (this parameter is called Delta in the program). This part is based upon the so-called zone-axis method; it uses the standard formulas for interplanar angles and spacings as functions of Miller indices [6] for cubic, tetragonal, orthorhombic, and hexagonal crystals. Delta is the difference between the measured angle on the diffractogram and the angle as calculated by the program for a pair (hi ki li )1 and (hj kj lj )2 (taken as a possible solution). While the program requires at least two points, a typical analysis of a diffractogram will use three or more points. The fourth (Fig. 4) and fifth screens assist the user in selecting the best solution, starting from the zone axis or using F IGURE 3. Third screen where the actual calculations are performed. F IGURE 4. Fourth screen where the possible solutions are displayed.

104 R. GALICIA, R. HERRERA, J. L. RIUS, C. ZORRILLA, AND A. GÓMEZ the differences between the calculated and observed angles. The results can be stored in a (text, excel, etc.) file. 4. Program Operation The strategy followed to reach a plausible solution can be summarized as follows: (a) Normally the user has an idea of what sorts of compounds are worth examining. In order to do this the user has to make sure that the relevant X-ray cards have been captured beforehand; otherwise he will have to capture the data using the second screen (Fig. 2). In case the user has no idea at all concerning the nature of his sample he will have to run the program over all the entries in the database, but of course this will not warrant that the right compound is there. (b) From the x-ray crystallographic data table, two sets with seven Miller indices {h,k,l} are selected. Each set is selected so as to correspond to the closest d hkl spacing (in Å) to d 1 and d 2, respectively. Consider the example given in Fig. 5, the selected spots on the FFT correspond to distances d 1 = 2.33 Å, d 2 = 1.97 Å and d 3 = 2.28 Å. Upon examination of the corresponding x-ray crystallographic data card for Fe 0.902 O (cubic), we see (Table I) that the distance closest to d 1 = 2.33 Å is d = 2.3552 Å; for d 2 = 1.97 Å is d= 1.9672 Å and for d 3 = 2.28 Å is d= 2.2804 Å. Given that the distances measured on the FFT depend on the cursor position (set manually by the user), there is some associated error. In order to take this into account, we take three values above and three values below as tolerance and in this way we end up with seven values to consider. The program takes next the Miller indices and proceeds as described below. Should it happen that the chosen distance is the first in the card, the program takes this and the next six values. A similar procedure is followed if the chosen distance is the last one in the card. TABLE I. Example of the selection of distance sets for seven candidate compounds from the list of x-ray crystallographic data. PDF card number d 1 =2.33 Å d 2 =1.97 Å d 3 =2.28 Å #862316 2.5299 2.0396 2.4826 2.4826 2.0146 2.3954 2.3954 1.9905 2.3552 d=2.3552 Å d=1.9672 Å d=2.2804 Å 2.2804 1.9447 2.2456 2.2456 1.9230 2.2123 2.2123 1.9020 2.1500 (c) For each pair (h i k i l i ) 1 and (h j k j l j ) 2 (and all equivalent permutations and sign changes), cos(θ 12 ) calculated and compared to the value measured from the diffractogram (taken from the first screen). If Delta 12 is larger than the given tolerance, the program rejects the solution. (d) If Delta 12 is less than or equal to the tolerance, the solution is stored in a file and the program calculates d (hkl), the distance between consecutive planes in the same family {hkl}, and the corresponding zone axis [uvw]. (e) The procedure is repeated with another pair of indices until all possible permutations and/or sign changes are included. The program will repeat steps (c) and (d) more than 100 thousand times, but the number of possible solutions will depend on the value given to Delta 12. (f) The program repeats (b) but only for the third spot and takes as possible solutions the (h j k j l j ) 2 stored in the file (step e) for the second spot. (g) With these new sets, steps (c) and (d) take into account not just the value of Delta 23 but also the zone axis, which should be the same as the one found for the first two spots. (h) The solutions are stored in a new file. It may happen that there is no solution, in which case the program will indicate that the search is over, but the solution screen will remain blank. 5. An application of the program Figure 5 shows an example of this procedure applied to a 3 nm nanoparticle. The particle was synthesized by means of bioreduction using alfalfa as a reducing agent in distilled water with FeNH 4 (SO 4 ) 2 12H 2 O and a buffer solution at ph=10. The high resolution image was obtained with a JEOL2010- FEG microscope. Given that in this case we have followed all the steps necessary to obtain iron oxide nanoparticles we will search for our solution among the x-ray cards [7] for Fe 3 O 4 (Magnetite, cubic, PDF#890688), Fe 0.902 O (Wuestite, cubic, PDF#862316), FeO (Wuestite, cubic, PDF#890687), FeOOH (Lepidocrocite, orthorhombic, PDF#741877) and Fe 2 O 3 (Maghemite, cubic, PDF#391346). The FFT was obtained from the image with the Digital Micrograph (DM) software, (Fig. 5), three spots were selected for analysis. The positions of these points with respect to the 000 spot were P 1 = (1.64,-3.96), P 2 = (4.92,-1.23) and P 3 = (3.41,2.73), and from them the program calculated the corresponding interplanar spacings, d 1 = 2.33 Å, d 2 = 1.97 Å and d 3 = 2.28 Å. The angles between vectors from the center spot to the other spots were θ 1,2 =53.47 and θ 2,3 =52.72.

A PROGRAM FOR PHASE IDENTIFICATION USING DIFFRACTOGRAMS OBTAINED FROM TEM STRUCTURE IMAGES 105 FIGURE 5. Example of a Fe 2O 3nanoparticle: (left) structure image of 3 nm particle and (right) indexed diffractogram showing the points (spots) used for analysis. After running the program using the x-ray crystallographic data from the table for the five chosen candidate compounds, it was found that the best fit was with Delta 1,2 =1.07, Angle 1,2 =52.4, Delta 2,3 =0.32, Angle 2,3 =52.4. For a Zone Axis of [1,0,1], the indexing of the three planes was: Plane 1 = (-1,1,1), Plane 2 = (0,1,0) and Plane 3 = (1,1,-1), which yielded interplanar spacings of d 1 =2.36Å, d 2 =1.93Å and d 3 =2.36Å. These values suggest that the unknown nanoparticle is FeOOH with a orthorhombic structure as shown in Table II. TABLE II. Summary of the best matches for each candidate structure. Plane a b Compound Delta a b Spacing a Spacing b Zone Axis 1-2 Fe 3O 4 1.266 2.42 2.10 [1,1,0] 2-3 2.016 2.10 2.42 [1,1,0] 1-2 Fe 0.902 O 1.266 2.24 1.94 [1,1,0] 2-3 2.016 1.94 2.24 [1,1,0] 1-2 FeO 1.266 2.47 2.14 [1,1,0] 2-3 2.016 2.14 2.47 [1,1,0] 1-2 FeOOH 1.07 2.36 1.93 [1,0,1] 2-3 0.32 1.93 2.36 [1,0,1] 1-2 Fe 2O 3 1.266 2.41 2.08 [0,1,1] 2-3 2.016 2.08 2.41 [0,1,1] Thus, in Table II we have presented the best solutions for the tested structures, and they are very similar. However, in this case for FeOOH we get the lowest Delta values and the best fitting with the measured distances. 6. Discussion The program requires the use of the DigitalMicrograph (DM) program and X-ray crystallographic data for various known substances. The DM package was used to analyze the images, to Fourier-transform them, and to obtain the coordinates of the various spots. Under DM it is possible to work at 64 64, 128 128 and 256 256 resolutions. This implies varying errors in the spot positions as a function of pixel size, so the program works within a given tolerance. The solutions are understood as best fits. Given the spot positions, the program searches for a fit to interplanar distances and angles between planes. Currently, it works for cubic, tetragonal, orthorhombic, and hexagonal structures. By considering all the possibilities, for every pair of spots, the program can produce up to 100,000 solutions in general. This number is quickly reduced to a few dozen possibilities by ruling out those where the angles produce matches outside the user-given tolerance. The program produces a list of possible solutions, and the final choice is left to the user. Some of the virtues of the program are that it is friendly and easy to use, no special expertise is required, only modest memory resources are needed, the search takes only a few seconds, and the lattice parameter data captured can be stored in a data base for future use. Since it is based on a micrograph, smaller regions of the sample (a few nanometers) can be studied than with selected area electron diffraction. Of course our approach is not meant to be a replacement for convergent beam electron diffraction (CBED), but it can be useful not only when CBED is unavailable but also when a set of high resolution micrographs is available and crystallographic information of small areas is desired. The main limitation of the program is that the user has to guess (from the chemical and physical conditions of sample preparation) what are the likely structures and to include the corresponding X-ray data; it is impossible to include all the available cards. The accuracy of the method is limited by the precision with which the magnification in the micrograph is known. In principle it would be desirable to have a built in standard together with the actual sample. 7. Conclusions Diffractograms obtained as Fourier Transforms from a digital TEM image can be used to identify an unknown crystal in the image. This article describes a program devised to achieve this. The program has a graphical user interface that allows the user to control various windows, input boxes, and processes. Measured data can be compared with data from candidate compounds to arrive at the likely identity of the unknown crystal. Crystals of only a few nanometers in size can be analyzed by this method. Acknowledgements The authors acknowledge the financial support from DGAPA with grant PAPIIT IN105109-5 and Conacyt grant 82270.

106 R. GALICIA, R. HERRERA, J. L. RIUS, C. ZORRILLA, AND A. GÓMEZ 1. Raymond P. Goehner and Prakash Rao, Metallography 10 (1977) 415-424. 2. C. Narayan, J. of Electron Microscopy Technique 3 (1986) 151-158. 3. P. A. Stadelmann, Ultramicroscopy 21 (1987) 131-146. 4. Harold R. Powell, Acta Cryst. D55 (1999) 1690-1695. 5. C. E. Lyman, M. J. Carr Identification of Unknowns, in Electron Diffraction Techniques, Vol. 2, J. M. Cowley (ed.), International Union of Crystallography )Oxford University Press, New York, 1993) pp. 373-417. 6. A.G. Jackson, Handbook of Crystallography for Electron Microscopists and Others (Spring-Verlag, 1991). 7. Powder Diffraction File (PDF) 2.4, (International Centre for Diffraction Data, 2003).