TS93 EMR T/PT/TDE. Surface applied door closer



Similar documents
8900 EMR (WITH DETECTOR)

EMF/EMR. Holder/Release Devices with Integral Door Closers

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

DORMA ED 800 SERIES Service Manual

Installation Instructions K900 series Door Closer

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES


3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Wiper Motor Marinco 2.5. Installation Instructions

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

BODY-12, Door Handle - Removal, Installation, and Adjustment

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Model 2300DR Installation Guide

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

How To Fit A T.V Door Closer

TECHNICAL INFORMATION

OPL BASIC. Dosing System for Professional Laundry machines. Contents

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

2013 Wireless Video Intercom INSTALLATION GUIDE

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Hinge, Blocker, and Tab Adjustment Guide

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

! WARNING. Before using product, read and understand instructions.

HERZ-Thermal Actuators

9300BC SERIES Light Commercial Door Closer

Duct Humidity Transmitter

DIGITAL WARMING CABINETS

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

7200 series Electromechanical Closer/Holder

Anthro Tablet Charging Cabinets

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

E-PDD Duct Smoke Detector Installation Sheet

GE Wireless Devices Battery Replacement

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

PS6500 Storage Arrays Rack Mount Instructions

STANLEY DOOR CLOSERS D-4550/D-4551 D-4550 / D-4551 SERIES OOR CLOSERS

Original Assembly Guide

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

Pulleys and Belt. Install the Major Accessory and Pulley. Install the Motor Pulley NOTE. Align the Motor Pulley and the Tool Pulley NOTE

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Advantium 2 Plus Alarm

PRS Y-axis EChain Installation

Install Guide CT101. Caution. Caution

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Micro Cart User's Guide

2M IR Mini Dome Quick Installation Guide

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Drayton Digistat +2RF/+3RF

Installation Manual. SKU# series (Base Rails) SKU# series (Overhead Racks)

Contractors Guide Central Inverter System Installation

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

INSTALLATION INSTRUCTIONS

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005

Owner's Copy December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Premier & Deluxe 3-Season Room Sliding Glass Door

K17.12 Door closers K17. Doors

Windshield Wiper System

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

TS83. Easy action door closer

All-Season Sunroom Sliding Glass Door Installation Instructions

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SETTING UP YOUR 6000 SERIES TIME RECORDER

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Digital Keypad Use s Manual

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

42U/45U 28" Wide Rack Installation & Service Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Solid-State Timer H3G

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Retrofit Instructions Installing a Sport Heated Steering Wheel - Leather, Multifunction BMW X5, E53,

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

OPERATING INSTRUCTIONS

Transcription:

TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double egress track mount door closer with smoke detector (EMR TDE)

TABLE OF CONTENTS Closer overall Technical specifications Door templates Size selection charts Electrical specifications Closer setup Exploded parts list Handing of the door Surface closer configurations A. Installing the surface closer Pull side mount (T) - Push side mount (PT) - Double egress mount (TDE) 0- B. Adjustments Adjusting the closing speeds Adjusting the spring force Adjusting the hold open C. Electrical setup Wiring diagrams - Final installation and tests 0 D. Final setup Installing the cover Smoke detector testing Technical specifications Templates Contents NOTE: Refer to the included drawings for push side door closer, back plate mounting templating. NOTE: Refer to the included drawings for pull side door closer, back plate mounting templating. NOTE: Refer to the included drawings for double egress door closer, back plate mounting templating. Note. Drawing is not to scale.. Dimensions are in inches/[mm].. Hand door see image note.. Caution: sex nuts are required for attachment of components to unreinforced doors and to wood or plastic faced composite type fire doors, unless an alternative method is identified in the individual door manufacturer's listings.. Template is for -/ x -/ butt hinges & /" offset pivots. Maximum door opening degree is: T = ; PT = 0 ; TDE = 0.. Minimum door width is: T = "; PT = "; TDE = ".. Hold open range with optional hold open kit is: T = 0-0 ; PT = 0 - ; TDE = 0 -.. The appropriate closer body styles are: T = "B" style; PT = "G" style; TDE = "B" style. 0. Arrows on closer mounting plate point upward. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Size selection charts TS EMR T Closer Interior/ Exterior Door Width '-" min. '-0" TS EMR T Interior N/A N/A TS EMR T Interior N/A N/A N/A '-" '-0" '-" '-0" TS EMR PT Closer Interior/ Exterior Door Width '-" min. '-0" TS EMR PT Interior N/A N/A TS EMR PT Interior N/A N/A N/A '-" '-0" '-" '-0" TS EMR TDE Closer Interior/ Exterior Door Width '-0" min. '-" TS EMR TDE Interior N/A N/A TS EMR TDE Interior N/A N/A '-0" '-" '-0" Electrical specifications Electrical connection Apart from the broad range of DORMA accessories, other manufacturers offer various activators, locking devices, safety sensors and additional accessories that are compatible with TS EMF closers. External activation device minimum requirements In general external activation devices need to provide a normally closed alarm contact. Contact ratings Operating voltage with power supply via operator: V DC + 0% -% VAC +0% -% Maximum input current: VDC ma VAC ma Dry contact, normally open devices (such as push buttons or overhead sensors): Minimum requirements Operating voltage with power supply via operator: V DC +/- 0% Operating voltage with external power supply: V AC/DC Current load for relay contact of locking device: A Power supply: V AC +/- 0% 0/0 Hz max. A Rated for continuous duty: electric strike: min. 0% Rated for continuous duty: motor lock: 00 % Power consumption for accessories: The operator will provide a maximum of. A at V DC for external accessories. Any additional power will require an external power supply in order to avoid malfunctions. Override Activation Inputs Note: These inputs bypass the mode switch and are always active. Dry contact, normally closed devices (frequently used to control systems with smoke and heat evacuation or building management systems): Use input terminals and and set parameter "d" to. Wet output devices with to volts (such as telephone/ intercom systems): Use input terminals and a. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Closer setup Follow included template to properly prepare door and frame for all accessories of the closer installation. Know the swing of the door which is being installed prior to installation. Verify closer spring size prior to installation. See "Size selection chart" on page. Make sure door efficiently operates prior to installing closer. The surface closer is comprised of the following components.. Closer body. Main arm. Track assembly. Pinion. Cover and end caps. Back plate. Closing/sweep speed adjustment. Latch speed adjustment. Backcheck adjustment 0. Delayed action adjustment. Smoke detector. Detector cover 0 Handing of the door Left hand door (LH) Interior side of door Right hand door (RH) Hinge Hinge Left hand reverse door (LHR) Exterior side of door Right hand reverse door (RHR) DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Surface closer configurations The surface can be assembled in the following configurations. a. Pull side mount configuration (T): Closer body style "B" [left hand reverse door] b. Push side mount configuration (PT): Closer body style "G" [right hand door] c. Double egress mount configuration (TDE): Closer body style "B" [left hand reverse door] DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE A. Installing the surface closer: Pull side mount (T) Tools recommended Drill Bits Metal: No. & 0- Tap Wood: /" #0 Phillips screwdriver # Phillips screwdriver /" flat head screwdriver Jeweler's flat head screwdriver M Hex key Installing the track, detector, and backplate Electrical wiring outside of the wall Electrical wiring inside wall Reference template 0 NOTE: For use on regular mount applications on the pull side of the door.. Orient the detector portion of the track () away from the hinge (see step image for orientation).. Remove the appropriate wire access plug () from the track. Left hand reverse door If removing the frame side wire access plug, ensure it aligns with the wire through hole in the frame.. For wiring applications that are outside of the wall, screw a surface conduit () into the exterior wire plug hole. Left hand reverse door. Attach the track channel () to the frame through the end blocks with two provided screws [/-0x" Phillips flathead screws or No. x-/" Phillips flathead screws] ().. Slide the front indent of the detector () under the standoff (), then attach the detector to the track with four screws [-0x/" Phillips pan head screws] (). Note: If construction is still being completed near the detector installation, DO NOT install the detector at this time or protect the detector from construction dust contaminants. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE. Attach the back plate () to the mounting surface using the four screws [0-x/" Phillips flathead screws or #0x" wood screws] provided with the surface closer, using the st and rd holes of the plate. Installing the surface closer NOTE: Make sure arrows on plate point upward. Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws [Mxmm Phillips flathead] () provided with the plate itself.. Attach the main arm () to the top pinion with an Mx0 socket head cap screw () and an M lock washer () using an M hex key. Be sure the main arm is parallel to the door during application. Left hand reverse door Left hand reverse door. Align the arm () with the slide shoe of the track channel.. Attach with one shoulder bolt () using an M hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE A. Installing the surface closer: Push side mount (PT) Tools recommended Drill Bits Metal: No. & 0- Tap Wood: /" #0 Phillips screwdriver # Phillips screwdriver /" flat head screwdriver Jeweler's flat head screwdriver M Hex key /" or mm box wrench Installing the track, detector, and backplate Right hand door Reference template 0 NOTE: For use on soffit mount applications on the push side of the door.. Orient the detector portion of the track () towards the hinge.. Attach the track channel () to the soffit with two screws [/x-/" Phillips flathead screws or No. x" Phillips flathead wood screws] () and through the center of the track with one screw [/x-/" Phillips flathead screws or No. " Phillips flathead wood screws] ().. Slide the front indent of the detector () under the standoff (), then attach the detector to the track with four screws [-0x/" Phillips pan head screw] (). Note: If construction is still being completed near the detector installation, DO NOT install the detector at this time or protect the detector from construction dust contaminants.. Attach the back plate () to the mounting surface using the four screws [0-x/" Phillips flathead screws or #0x" wood screws] provided with the surface closer, using the st and rd holes of the plate. NOTE: Make sure arrows on plate point upward. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws [Mxmm Phillips flathead screws] () provided with the plate itself.. Using an adjustable wrench (and looking up at the bottom of the closer): Left hand door - turn the bottom pinion counterclockwise 0 -. Right hand door - turn the bottom pinion clockwise 0 -.. Attach the main arm () to the top pinion with an Mx0 socket head cap screw () and one M lock washer () using an M hex key. Right hand door Be sure the main arm is parallel to the door during application. Right hand door. Align the arm () with the slide shoe of the track channel.. Attach with one shoulder bolt () using an M hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE A. Installing the surface closer: Double egress mount (TDE) Tools recommended Drill Bits Metal: No. & 0- Tap Wood: /" #0 Phillips screwdriver # Phillips screwdriver /" flat head screwdriver Jeweler's flat head screwdriver M Hex key Installing the track, detector, and backplate Electrical wiring outside of the wall Electrical wiring inside wall Reference template 0 NOTE: For use on regular mount applications on the pull side of the door.. Orient the detector portion of the track () away from the hinge.. Remove the appropriate wire access plug () from the track. Left hand reverse door If removing the frame side wire access plug, ensure it aligns with the wire through hole in the frame.. For wiring applications that are outside of the wall, screw a surface conduit () into the exterior wire plug hole. Left hand reverse door. Attach the track channel () to the frame through the end blocks with two provided screws [/-0x" Phillips flathead screws or No. x-/" Phillips flathead wood screw] (). 0. Slide the front indent of the detector () under the standoff (), then attach the detector to the track with four screws] -0x/" Phillips pan head screws] (). Note: If construction is still being completed near the detector installation, DO NOT install the detector at this time or protect the detector from construction dust contaminants. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE. Attach the back plate () to the mounting surface using the four screws [0-x/" Phillips flathead screws or #0x" flathead wood screws] provided with the surface closer, using the st and rd holes of the plate. NOTE: Make sure arrows on plate point upward. Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Attach the closer body () to the plate using the four screws [Mxmm Phillips flathead screws] () provided with the plate itself. / Left hand reverse door. Attach the main arm () to the top pinion with an Mx0 socket head cap screw () and an M lock washer () using an M hex key. Top view Be sure the smaller portion () of the main arm is angled approximately away from the door during application. Left hand reverse door. Align the arm () with the slide shoe of the track channel.. Attach with one shoulder bolt () using an M hex key. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE B. Adjustments Confirm closer spring size prior to making any closing speed adjustments. Do not back valves out beyond closer casting. Maximum opening angles are listed on page. Door should close in to seconds from 0º. Do not close valves completely. Adjusting the closing speeds: sweep, latch or backcheck and delayed actions Delayed action [Sweep] [Latch] [Backcheck] Backcheck Sweep [Delayed action] Latch Decrease Increase Sweep & Latch Speed. Adjust the sweep speed () for the area from the maximum open position to 0. Maximum opening degrees are listed on page. Increase sweep speed: Turn valve counter-clockwise Decrease sweep speed: Turn valve clockwise.. Adjust the latch speed () for the area from - 0. Increase latch speed: Turn valve counter-clockwise Increase Decrease. Adjust the backcheck () for the area from 0 to maximum opening. Increase resistance: Turn valve clockwise Decrease resistance: Turn valve counter-clockwise.. Adjust the delayed action () for the area from 0 to 0. Increase delayed action: Turn valve clockwise Backcheck & Delayed actions Decrease delayed action: Turn valve counter-clockwise Adjusting the spring force Increase Decrease CLOSER TYPE MAX DOOR WEIGHT (LBS) SPRING SIZE FULL TURNS OF SPRING ADJUSTER + TS 0 + 00 + TS 0 0 TS NOTE: Supplied with a size spring setting. Adjust according to chart. TS NOTE: Supplied with a size spring setting. Adjust only if more spring tension is required to positively close and latch door. DOOR WIDTH FULL TURNS OF CLOSER INT. EXT. SPRING ADJUSTER SIZE ' '" + '" ' + ' '" + NOTE: DO NOT ADJUST SPRING LOWER THAN SIZE DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Adjusting the hold open Less hold open angle Greater hold open angle NOTE: Hold open position is preset at approximately 0.. Loosen the set screws () using a /" hex wrench.. Slide the hold open to the desired position.. Tighten the screws to desired the position. C. Electrical setup Wiring diagrams. Turn the screw () with a screw driver to set the force needed to manually disengage the hold open: Clockwise = increase force Counter clockwise = decrease force Note: An auxiliary door stop must be installed to limit the maximum degree of door swing. Failure to do so may result in damage to the unit. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE SECONDARY TRANSFORMER WIRES PRIMARY TRANSFORMER WIRES EXTERNAL STEP DOWN TRANSFORMER (OPTIONAL) 0VAC POWER INPUT 0 VAC/DC POWER SUPPLY 0 0 0 VAC/DC POWER SUPPLY 0 0 0 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE No. OF ELECTRO- MAGNET (E) No. OF ELECTRO- MAGNET (E) No. OF ELECTRO- MAGNET (E) No. OF ELECTRO- MAGNET (E) POWER SUPPLY WIRE LENGTH TO E (D) WIRE LENGTH TO E (D) WIRE LENGTH TO E (D) WIRE LENGTH TO E (D) TO NEXT HOLD OPEN SOLENOID #-# # 0 # #-# #-# #-# 0 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE AUXILIARY HOLD OPEN ELECTROMAGNET MAIN HOLD OPEN ELECTRO- MAGNET UL/ULC LISTED ALARM CONTROL PANEL POWER IN HOLD OPEN ELECTRO- MAGNET VOLT ONLY 0 0 0 0 0 0 0 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE VAC/DC POWER SUPPLY 0 UL/ULC LISTED AUDIBLE SIGNAL APPLIANCE OR CONTROL UNIT 0 UL/ULC LISTED AUDIBLE SIGNAL APPLIANCE OR CONTROL UNIT 0 0 0 UL/ULC LISTED AUDIBLE SIGNAL APPLIANCE OR CONTROL UNIT 0 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE + CONNECTIONS FOR SIX () WIRE INSTALLATION CONNECTIONS FOR SIX () WIRE INSTALLATION 0 0 A Continued on page DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE 0 0 0 0 0 0 B DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Final installation and tests SD- Detector sensitivity test (ULC requirement only). Apply power to the detector.. Connect a voltage meter to the two test terminals ().. The normal range is between.vdc -.Vdc. Check all the wiring and connections. The LED () should blink every - 0 seconds.. If not, verify the wiring of the device. Test the hold open unlatching function. Open the door so the slide shoe engages the hold open mechanism. Test the detector. Insert a small screwdriver into the light pipe () and turn counter-clockwise. Hold for 0 seconds.. The LED will turn red and the door will close.. Turn the light pipe clockwise back to the original position to reset the detector.. The LED will turn off and then begin to blink as described in step. 0 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE D. Final setup Installing the covers. Snap both end covers () into place.. Remove the un-needed tab (), and snap the closer body cover () into place.. Attach with a -0 Phillips pan head screw ().. Slide the tab () of the detector cover () under the end of the detector () and swing it into position.. Secure the detector cover with one -0x/" Phillips flathead screw. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

TS EMR T/PT/TDE Smoke detector testing Aerosol testing is a "go - no go" test and is not an acceptable means to test smoke detector sensitivity. If the local air velocities exceed 00 ft/min, the detector may not alarm on the first try.. Aim the Smoke Detector Tester tube at the detector and release a burst of aerosol in second bursts. Note: The detector may take up to 0 seconds to respond.. If the detector does not alarm and is in a high air velocity area, spray up to five bursts in to 0 second intervals.. If the detector still does not alarm after five repeated aerosol sprays, a higher smoke volume may be needed. DORMA accepts the use of Home Safeguard Smoke Detector Tester (Models H and S) if, and only if, it is used: With the Model 0 accessory. With the new formula as identified by a date code, located on the bottom of the can, of 0 or later. In accordance with the instructions stated above If the preceding requirements are not met, the use of the Smoke Detector Tester is unacceptable and DORMA cannot guarantee the proper operation of detectors that have been subject to this product. Other acceptable methods of aerosol or smoke generation: Gemini 0 Smoke Generator Machine (set to %/ft to %/ft obscuration as described in the Gemini 0 Manual) Burning paper or fabric in a metal can (useful for application in high air velocity locations) Burning cigarettes, punk, or cotton wick (commonly available materials) DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 00-- E-mail: dormaarchitectural@dorma.com 000 0/ Reamstown, PA Fax: 00-- Subject to change without notice

DORMA USA, INC. DORMA DRIVE, DRAWER AC REAMSTOWN, PA TOLL-FREE: 00-- FAX: 00-- E-MAIL: DORMAARCHITECTURAL@DORMA.COM WWW.DORMA-USA.COM 000 0/0, Subject to change without notice