SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.



Similar documents
SMART SENSOR COLLECTION

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Executive Summary. Technical Description

Specification Requirements DBL 700MX and 1000MX Series UPS

Adit 3000 Series Part Guide

Temperature & Humidity SMS Alert Controller

Uninterruptible Power Supply

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAJORSINE Power Inverter

Phase Modular Finally the benefits of Modular ups are for all

TrueAlarm Fire Alarm Systems

Computer Cabinet Environment Monitor

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

HM-W536 Install Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Chassis, Power Supply, and Element Management

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Remote Monitoring and REC 501 Control Unit Product Guide

Cisco Redundant Power System 2300

NetScanner System. Toronto: , Montreal: , Toll Free: ,

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

Temperature & Humidity SMS Alert Controller

T1 Backhaul Connectivity Solution All Products :: Application Note

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

SECTION DETECTION AND ALARM

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

TMS TANK MANAGEMENT SYSTEM

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

8-Port PoE Network Switch

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SAGEON SITE MONITOR (SSM) Application Note AN

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

NeuStar Ultra Services Physical Security Overview

IFS SP-PoE Splitter User Manual

Server Technology, Inc.

SWITCHGEAR. EGP Switchgear

Power & Environmental Monitoring

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

GSM Voice Auto Dialer & SMS Sender JC-999

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

OPERATIONS MANUAL DATA CENTER COLOCATION

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Harris County, Texas. Extra Low Energy LED DC Cabinet System Alternative Energy System

PowerCommand iwatch 100

Magnum Mobile Generator MMG55 Specifications

3500/22M Transient Data Interface

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

How to Monitor Every Small Site in Your Network... Without Breaking Your Budget

Office of Integrated Security Systems Longwood University Camera System Standards

Inverter / Charger Installation General Operations and AC and DC Connections

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Electronic Control Devices The European Product Catalogue 2007

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

How To Sell A Talan

Fire Pump Controllers Remote Alarm Panels

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Smart-UPS On-Line 230 V

Cisco Unified IP Phone Power Injector

Advantium 2 Plus Alarm

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Infinity C DC to DC Power System

Zertico Rack Monitoring Unit

Innovative Electronics for a Changing World INDEX

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Understanding Emergency Power Off (EPO)

PowerGem Pro Uninterruptible Power Supply

Product Guide CM-Relay

FIREDEX Conventional Fire Panels

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Data Centre Services. JT Rue Des Pres Data Centre Facility Product Description

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Installation Instructions for Alarm Module Kit A043F059

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS. Trend Datacom USA, Inc.

Transcription:

SiteRanger tm Comprehensive Broadband/ Enterprise site monitoring device for Headend s, Hub Sites. Power quality / site monitoring Focus on power system infrastructure Retrofit legacy devices for remote visibility Contact closure based unit for basic SNMP output SR2 Modules provide analog measurements such as temperature, generator fuel levels, AC and DC power system voltage, current and power, ground current and many other parameters. Comprehensive system for Broadband Communications facility power and site infrastructure monitoring. > SiteRanger SR1: Consists of a 2RU rack mount unit that can accept 8,16,24, or 32 contact closure input channels - normally open or closed. Accepts contact closures from UPS and DC systems, Generators, HVAC units, Fire Suppression, access control and other site devices. Simple contact closure input, SNMP Ethernet output system for remote network operation center monitoring via enterprise network management software such as CA Spectrum, HP OpenView, Micromuse Netcool etc. Compliant with Broadband-Enterprise VOIP telemetry alarm requirements for site monitoring and remote visibility. SNMP trap output to remote NOC monitoring servers. > SiteRanger SR2: Consists of a series of dedicated purpose acquisition modules connected via the CSInet Cat5E network that are all centrally powered via PoE. Dedicated modules are installed/retrofitted in legacy or new power system devices such as Generators, Automatic transfer switches, UPS systems, -48VDC power systems, AC distribution panels and other power infrastructure devices. Additional SR2 devices include HVAC environmental monitor, network ground current monitor and DC distribution current monitor. SR2 modules can also be deployed on a local basis via internal webserver function. Simply point your browser to the SR2 device IP and instantly review power system operating parameters on a local headend or hub basis. > Ala Carte approach: Allows installation of specific monitoring modules as needed for retrofit to existing sites and for upgrade/additions of new devices as facilities grow. > Open Source - non proprietary: Standard network interface for cost effective implementation. SNMP data - TCP/IP web. CSInet utilizes Cat5E network with PoE interface to provide highly reliable and redundant single point powering of remote SR2 devices. All devices are powered from a PoE enabled switch via -48VDC with battery back-up or 120VAC UPS. SiteRanger data output is available via many customer access topologies - no proprietary software licenses! > 15 years of experience in power systems integration in the Broadband network facility market nationally. CSI has installed hundreds of Generators, AC switchgear systems, UPS systems, -48VDC systems and integrated device monitoring implementation. CSI provides installation, service and maintenance local support via CSI regional service facilities with a competent staff of power system professionals. The SiteRanger product family provides an innovative and targeted monitoring overlay for power quality monitoring benefit for the local headend technician to the the Enterprise network operations center.

SiteRanger power quality - site monitoring SiteRanger SR1 SR1 Implementation configuration: SiteRanger SR1 Rack mount unit UPS system Standby Electrical Generator -48VDC Power system Commercial Power input status Fire Suppression system ATS Automatic Transfer switch Contac t closure monitoring for legac y devices: Examples of contact closure device sources: Standby electrical generator, ATS, UPS system, -48V DC plant, Fire suppression, HVAC, Commercial power monitor, Temperature alarms, intrusion alarms, distribution fuse or circuit breaker trip alarms and other contact closures or switches. Power and facility device dry contact source circuits are routed to a cross-connect termination block system in the facility and then connected via 50 conductor cable harnesses to the the SiteRanger SR1 rack mount monitor. SNMP alarm traps are created upon input port alarm function and sent via Ethernet TCP/IP to local or remote IP addresses for SNMP network management software tracking and reporting functions. SiteRanger SR1 can send SNMP traps to two IP addresses simultaneously. Advantages include simply wire pair contact closure wiring from site devices to cross-connect and SiteRanger unit. Many legacy devices have relay contacts and switches available that provide basic functional monitoring of device status. Contact closures can be configured normally open or normally closed and the SiteRanger SR1 unit can alarm on either. Implementation of the SR1 system is simple and reliable. Disadvantages include the fact that the SR1 system does not provide analog parameter monitoring. It is intended to provide notification of failure or distinct conditions as communicated by on/off contact status. Qualitative information such as analog power parameters, temperature, humidity, fuel level, etc cannot be provided that are valuable for capacity management, early detection of failure and analysis of site reliability. The SiteRanger SR2 system is designed for Ala carte implementation of remote acquisition modules interconnected on a network to provide analog data for more detailed and sophisticated site visibility.

SiteRanger tm SR2 SR2 Distributed Network monitoring modules. Remote power via PoE - reliable and redundant Dedicated function modules - targeted monitoring Connect via CSInet or direct LAN connection for local monitoring > Individual dedicated function modules are retrofitted/installed in power devices, HVAC, Fire Suppression and other site systems to provide both contact closure and analog parameter monitoring to provide significant remote visibility of facility status. > SR2 Modules are designed for interconnection via CSInet which includes an industry standard Cat5E network with PoE enabled network power distribution to provide reliable central power for the SR2 modules. CSInet provides individual Cat5E connectivity for data and power for the SR2 modules without proprietary wiring or interconnection limitations. Standard network wiring devices and components are used for maximum cost and reliability benefit. > Contact closures and analog parameter acquisition provides the maximum in remote visibility. Each SR2 module includes inputs for contact closures from site devices as well as electrical monitoring connectivity for AC/DC power parameters as well as other analog information such as temperature, humidity, generator fuel level etc. > SiteRanger SR2 modules include dedicated purpose configurations that allow the end user to decide which site devices should be monitored and to add these devices as required over time instead of pre-purchasing the entire monitoring infrastructure in advance. This ala carte approach saves cost and still allows the SiteRanger system to be future proof by allowing new modules to be added over time in the future as new equipment is added or selected to be monitored. SR2 Available remote acquisition modules: : AC monitor Single or three phase. AC volts, amps, watts, VA, power factor, frequency. Eight contact closure inputs for device alarm contacts. Used in Automatic transfer switches, UPS systems, service entrance panels, distribution breaker panels. DCM: DC monitor -48V DC volts, amps, watts, VA, Temperature. Eight contact closure inputs for device alarm contacts. Used in -48VDC powerplants, rectifier bays, BDFB cabinets, distribution bays. GSM: Generator system monitor Single or three phase. AC volts, amps, watts, VA, power factor, frequency, temperature, starting battery voltage. Eight contact closure inputs for generator status alarm contacts. FSM fuel monitor input port for fuel level sensing. Used in standby electrical generators. EVM: Environmental system monitor Temperature, Humidity, HVAC status. Eight contact closure inputs for HVAC status alarm contacts. Used in hub rooms, headends, facility space. GNSM: Ground network system monitor Ground fault current for Telephony switch / VOIP infrastructure. Eight current sense inputs for MGB and other ground current detection locations.

SiteRanger tm SR2 AC Module Installed in UPS Single phase or three phase. Volts,Amps,power, VA power factor, frequency. AC Module Installed in ATS Single phase or three phase. Volts,Amps,power, VA power factor, frequency. CSInet Cat 5 network with PoE Central power source for all modules on network DCM DC Module Installs in -48VDC power system-rectifier bay or distribution cabinet. DC volts, amps,power, temperature. To enterprise network GNSM Ground network system monitor. Installs on MGB main ground bus and secondary ground feeder connections. Detects and measures ground fault current on Telco / Voip switch ground network. 8 current sense inputs. PoE (Power over ethernet) switch -48VDC source with battery back-up. EVM Environmental Module Installs in Hub room. Temperature, humidity, HVAC alarm monitoring. GSM Generator Module Installs in generator housing. AC volts, amps, power, VA, frequency, starting battery DC volts. FSM Generator fuel level sending unit. Installs on diesel or propane tank. Propane rotary gauge sending module or diesel tank float sensor.

SiteRanger SR2 tm Advanced remote monitoring and site visibility Power quality monitoring for high reliability SiteRanger SR2 Module configuration: Power parameters: Analog parameters Contact closure inputs AC monitor UPS 1ph/3ph Volts, amps, watts, VA, Voltage, Current, Frequency Hz, PF, phase imbalance. UPS on battery, UPS on commercial power, UPS fault, UPS in static bypass, UPS fan fail, UPS low battery, battery fault, UPS distribution circuit trip. AC monitor ATS 1ph/3ph Volts, amps, watts, VA, Voltage, Current, Frequency Hz, PF, phase imbalance. Site connected to commercial power, site connected to generator power, ATS not in auto mode, battery charger fault, exerciser mode active, generator run. DCM DC monitor DCV, DCA, watts, charge A, load A. Temperature Rectifier fail, major alarm, minor alarm, battery offline, distribution fuse fail, overtemp alarm, AC input fail, system fail. EVM Environmental monitor Temperature, humidity, overtemp alarm. HVAC general alarm, compressor fail, controller fail, condensate drain alarm. 8 contact inputs for multiple HVAC unit alarms. GSM Generator System monitor 1ph/3ph Volts, amps, watts, VA, Starting battery voltage, Hz, PF, phase imbalance. temperature, fuel level, starter current. GNSM Ground network system monitor Ground fault current in Amps, Eight current sensor inputs for current flow direction, peak MGB, SGB, Telephony switch current, AC ripple current. ground window etc. GM8 General monitor module 8 contact inputs for misc alarms: TVSS fail, Fire suppression, intrusion alarm, Tech on site, smoke detect, fuse fail, breaker trip, etc. FSM Generator fuel status monitor Diesel or propane fuel level sending unit. Connects to GSM module input port. Rupture basin alarm, over-fill alarm, low fuel alarm, leak alarm, low gas pressure alarm. PoE powerpoint -48VDC power injector point for PoE cat 5 network. Provides power for CSInet modules Generator summary alarm, not in auto mode, generator running, low oil, low coolant, overcrank, High temperature, tamper alarm.

SiteRanger SR1 and SR2 product family General Specification: Series model # P/N 016-900-10 P/N 016-905-10 P/N 016-910-10 Configuration SiteRanger SR1 Contact input-snmp output Contact inputs, internal DC/AC power supply. VFD display LED interface panel, 19/23 Rack mount housing. AC power module. Monitors single or three phase AC voltage, current, power parameters.. Use for ATS site power monitoring, UPS output monitoring. DCM DC power module. Monitors -48VDC rectifier and battery system status. Measures DC voltage, current, distribution circuit breaker trip, battery status, accepts alarm contact outputs from DC power system. Part # 016-900-10 (8 inp.) 016-901-10 (16 inp.) 016-902-10 (24 inp.) 016-903-10 (32 inp.) 016-905-10 016-906-10 016-907-10 016-908-10 016-910-10 016-911-10 016-912-10 Description Rack mount housing. Accepts 8/16/24/32 contact inputs, LAN. Ethernet 10/100 Base T jack with LED indicators. -48VDC/120VAC input, internal power supply Non-metallic housing with terminal block connections for AC voltage sense, current transformer input sense, ATS position sensing (generator/commercial power), 8alarm contact inputs. CSInet LAN port. Specify 1,2 or 3 phase, 120V, 240V, 208V, 480V versions. Current transformers available for 100, 200, 400 and 600A systems. Non-metallic housing with terminal block connections for DC voltage sense, DC power system contact closure inputs, distribution alarm contact inputs, CSInet LAN port. Specify input configuration, current monitoring kit, battery temperature probe kit. P/N 016-915-10 EVM Environmental module. Monitors HVAC alarm contact outputs, temperature, condensate drain alarm, multiple temperature sensor, humidity sensor. 016-915-10 016-916-10 Non-metallic housing with terminal block connections for 8 HVAC system alarm contact inputs. Temperature sensor, humidity sensor, CSInet LAN port. 8 input ports. P/N 016-920-10 P/N 016-925-10 P/N 016-927-10 P/N 016-929-10 GSM Generator status module. Monitors Generator contact closures, fuel level, starting battery voltage. AC power parameters. FSM Generator fuel status module. Monitors Generator fuel level. (Diesel or propane). GNSM Ground network system monitor. Multipoint ground current monitoring. GM8 General monitor module. Contact inputs only. Generic use for devices. 016-920-10 016-921-10 016-922-10 016-930-10 016-931-10 016-932-10 016-933-10 016-935-10 016-940-10 Non-metallic housing with terminal block connections for generator output AC voltage/current sense, 8 alarm contact inputs. CSInet LAN port. Specify 1,2 or 3 phase. Monitors Generator fuel level. Specify diesel tank level sensor, propane tank transducer head (various versions depending upon tank vendor). Monitors ground fault current at up to 8 sensor locations. Specify Shunt or hall effect sensor modules. Monitors any remote contact closure or switch. 8 inputs for general use for site monitoring devices. Common Specifications for All Models: SiteRanger SR1 Dimensions: 17" W x 3.75 (2RU) T x 12 D Weight: 13 Lbs. Rack mount with 19/23 reversible mounting flanges.hinged cover w/led or VFD control panel. Unit includes wiring diagram / instruction manual, software, spare fuses. Input contact detachable set screw terminals. 10BT/100BaseT ethernet RJ45 jack Electrical specifications: Input: 120VAC power supply and dual -48VDC redundant inputs. All three power inputs are redundant and will operate the unit. SiteRanger SR2 Dimensions: 5" W x 7.5 T x 2.5 D Weight: 4 Lbs. Wall surface mount. Sealed cover w/led and LCD control panel. Unit includes wiring diagram / instruction manual, software, spare fuses, 10BT/100BaseT ethernet RJ45 jack, analog input connectors, input contact connectors. Electrical specifications: Input: Network powered via CSInet PoE power over ethernet. Local power port 12VAC power cube option. Order Info: Shipping box packaging for UPS/FedEx shipment. Typical configuration includes bill of materials / parts kit as per customer site survey order form. CSI Provides customer site surveys at no charge to provide customer proposals for the correct SiteRanger component and installation configurations. www.commnetsystems.com E. sales@commnetsystems.com 800 274 0544 (24/7 Sales & Service) Seattle Corporate Office 4237 24th Avenue W. Seattle, WA 98199 T. 206 282 8670 F. 206 282 8684