Bologna 12-13 Maggio 2011; 1 MS Environmental Day



Similar documents
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Monitoring of Pesticides Residues in Italian Mineral Waters by Solid Phase Extraction and Gas Chromatography Mass Spectrometry

Background Information

Innovative vs Traditional

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Expectations for GC-MS Lab

Biocides main groups

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

How To Test For Contamination In Large Volume Water

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Application. Gas Chromatography September 1997

Oasis HLB Cartridges and 96-Well Plates

Analyzing Small Molecules by EI and GC-MS. July 2014

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Opiates in Urine by SAMHSA GC/MS

ORGANIC SAMPLE PREPARATION

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

AMD Analysis & Technology AG

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Gas Chromatography Liner Selection Guide

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Split / Splitless Injection for Capillary GC

Removal of Reaction Solvent by Extractive Workup: Survey of Water and Solvent Co-extraction in Various Systems

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Analysis of Liquid Samples on the Agilent GC-MS

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

SUCRALOSE. White to off-white, practically odourless crystalline powder

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

Solid Phase Extraction for Water Analysis. presented by

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Purification of reaction mixtures using flash chromatography.

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Analysis of Drugs by using the Ultra Inert Inlet Liners with Wool

Aromatic plants: from extraction to analysis

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

Analysis of Veterinary Drug Residues in China

Chemical analysis service, Turner s Green Technology Group

High-Throughput 3-D Chromatography Through Ion Exchange SPE

LC Application Note.

AppNote 1/2008. Automated Disposable Pipette Extraction of Pesticides from Fruits and Vegetables KEYWORDS ABSTRACT

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Multiresidue Analysis of Pesticides in Avocado with Agilent Bond Elut EMR Lipid by GC/MS/MS

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Multi Pesticides Residue analysis in Ayurvedic cough Syrup by GCMS/MS using QuEChERS extraction method

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

TechNote 3/2002. The Use of Different PTV Inlet Liner Types for Trapping Alkanes, Aromatics and Oxygenated Compounds During Thermal Desorption

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

23 The Thermal Conductivity Detector

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Pesticide Analysis by Mass Spectrometry

Transcription:

; 1 MS Environmental Day E. Salvadori, A. Falai, M. Cappelli, S. Dugheri, A. Bonacchi, G. Arcangeli, V. Cupelli, D. Santianni, D. Burrini

ISPRA reports: 50% of monitoring points of surface water are contaminated by pesticides 1 Generation Of Hazardous Waste 2 10000 kilogrammes of hazardous waste produced per person per year in the first 20 territory 1- Monitoraggio nazionale dei pesticidi nelle acque, ISPRA, 2007-2008; 2- www.worldmapper.org ; Bologna 12-13 Maggio 2011

54 pesticides ALACLOR ATRAZINA ATRAZINA - DESISOPROPIL ATRAZINA DESETIL AZINFOSMETILE BENDIOCARB CLORPIRIFOS-ETILE CLORPIRIFOS-METILE CLORTALONIL DEET (n,n dietil toluoamide) DICLOBENIL DICLORAN DIFENAMID DIMETOATO DIMETOMORF DIURON ENDOSULFAN alfa ENDOSULFAN beta ENDOSULFAN SOLFATO ETOFUMESATE FENHAXAMID FENITROTION FENPROPIDIN FLUFENACET FLUOROCLORIDONE IPRODIONE IPROVALICARB ISOPROTURON LENACIL LINURON MALATHION METALAXIL-M METAMIDOFOS METOLACHLOR (Dual) NAPROPAMID OXADIAZION Bologna 12-13 Maggio 2011 OXADIXYL OXYFLUORFEN PENCONAZOLO PRIMETANIL PROCYMIDONE PROPANIL - ROGUE PROPOXUR PROPYZAMIDE PROWL (Pendimetalin) SENCOR (Metribuzin) SIMAZINA SPIROXAMINA TEBUCONAZOLO TERBUTILAZINA TERBUTILAZINA DESETIL TOLYLFLUANIDE TRALCOXIDIM TRIFLURALIN - TREFLAN

VARIAN CP-3800 and Saturn 2200 IT with Gerstel MPS and MFX system

VARIAN CP-3800 and Saturn 2200 IT with Gerstel MPS and MFX system MFX Tray for 25 FFA SPME

Injector : 265 C Splitless 300 sec Desorption Time Flow/Pressure : 1.2 ml/min Pres. (psi) Vel.(psi/min) Dur. (min) Tot. (min) 45 ----- 0.5 0.50 Solved with Merlin Microseal 53.5 3.55 0 2.90 septum (Max pressure 90 psi) 1 critical point 58.4 0.7 0 9.90 68.6 0.68 0 24.90 72.6 3.33 0 26.10 Column Oven: Temp. ( C) Vel. ( C/min) Dur. (min) Tot. (min) 80 ----- 0.5 0.50 140 25 0 2.90 175 5 0 9.90 250 5 0 24.90 280 25 0 26.10

Saturn 2200 Ion trap EI ionization CI ionization [MeOH] collected from some articles 1,2,3 MS/MS parameters studied and optimized with injections of pesticides Single compound or mix solution 1- Sheridan, Meola; Journal of AOAC International, vol. 82, n.4, 1999; 2- Cortés-Aguado, Sánchez-Morito, Arrebola, Garrido Frenich, Martínez Vidal; Food Chemistry, 107 (2008),1314-1325. 3- Gonçalves, Carvalho, Azenha, Alpendurada; Journal of Chromatography A, 1110 (2006) 6-14.

CHROMATOGRAPHIC SYSTEM narrow-bore column VF-5MS, 20mt x 0.15 μm x 0.15 mm ID VS classic column VF-5MS, 30mt x 0.25 μm x 0.25 mm ID SAMPLE PREPARATION FFA SPME - MFX Robotic system VS SPE membrane filtration and solvent elution

29 min Total Run to Run Time 60 min Total Run to Run Time BUT 2 chromatography Run is necessary Analysis time reduction 50% Ion Trap in MS/MS ion preparation max 2 channel for segment 1 channel is recommended NOT ADEGUATE Point per peak number 0.1-0.2 min means width 20-25 points per peak

29 min Total Run to Run Time 60 min Total Run to Run Time Analysis time reduction 50% BUT 2 chromatography Run is necessary Ion Trap in MS/MS ion preparation max 2 channel for segment 1 channel is recommended ADEGUATE Point per peak number 0.1-0.2 min means width 20-25 points per peak

40 ml of water clear glass vial 1 Lt. Filtered on C-18 SPE membrane SPME/off-line extraction under agitation 4 h SPE membrane elution with 10 ml x2 of Ethyl Acetate FFA SPME disposed in 25 SPME tray Automatic injection and clean up concentration in Genevac system up to 500 µl 1 µl injection in GC-MS easy to use solvent free minimal manual intervention More manual operation High quantity solvent use reduced time for sample preparation

Absolute response Bologna 12-13 Maggio 2011 20 Coating from literature Part of results PDMS/DVB Polyacrylate PEG PDMS/CAR/DVB All coating were tested and evaluated for each analytes 18 16 14 12 10 8 6 4 2 ALACLOR ATRAZINA DESETIL ATRAZINA PROPYZAMIDE appropriate SPME Coating: PDMS/CAR/DVB suitable for molecules with different chemical/physical property PEG suitable for Triazine and more polar compound 0 PDMS/DVB PEG PA PDMS/CAR/DVB ENDOSULFAN beta

Direct Immersion in water without ionic strength modifier and injection in GC (T 265 C) PDMS/CAR/DVB No problems found Direct Immersion in water with 25% of NaCl, 60 sec. washing in water (acqua Panna) and injection in GC (T. 190 C Max) PEG PEG COATING WAS ABANDONATED

response % Bologna 12-13 Maggio 2011 100 80 60 40 20 0 0 100 200 300 400 500 240 min extraction time

Current Method compromise for 50 molecules 45 C was chosen

First Second

Legal limit - 100 ng/l for each compound LOQ: 10-50 ng/l LOD : 1-5 ng/l Internal standard : 1 chlorododecane 4,4 -dibromobiphenyl

Metamidofos VF-624 column for more polar compound Triazine

VF-624 column for more polar compound Metamidofos

Test of IL-65 column Apply the Method to Routine Analysis in first time for confirmation after to substitute the old method

Solvent Free Increases the life of the gas chromatographic system Costs reduction Minimal manual intervention Reduction hours/worker More time for research and development Elimination of interference by MS/MS ions preparation More selectivity and sensitivity