for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Size: px
Start display at page:

Download "for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns"

Transcription

1 for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

2 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N ) SolEx TM HRP RSLC Columns SolEx HRP RSLC (P/N ) 2011 Dionex Corporation

3 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 2 of 15 TABLE OF CONTENTS SECTION 1 INTRODUCTION... 3 SECTION 2 OVERVIEW AND USAGE Overview System Configuration and experimental workflow Use of SPE Cartridges Condition the SPE Cartridge / Column Storage Standard SolEx HRP Use Conditions Online SPE and separation of phenols Online SPE and separation of endocrine disruptive compounds Online SPE and separation of triclosan in soapwater SECTION 3 Appendix A. Example Chromeleon Program, Dual Injection Valves in UltiMate-3000 DC Column Compartment with AS-HV... 12

4 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 3 of 15 SECTION 1 INTRODUCTION Water contaminants, including pesticides, antibiotics, pharmaceuticals, etc., are of great concern to society and must be monitored. Method detection limits (MDLs) of liquid chromatography (LC) techniques employing direct injection of samples are too high for the detection of the low levels allowed in natural waters. Therefore, water samples often require preconcentration before analysis. Solid-phase extraction (SPE) is one of the most important techniques for sample enrichment because it overcomes many of the disadvantages of liquid-liquid extraction. It is an established sample preparation technique used for sample extraction, analyte enrichment, and sample clean-up. In off-line SPE, preparing individual samples is time consuming and a new SPE cartridge must be used for each sample. Use of SPE in an online mode allows many samples to be processed without offline conditioning of the SPE device. Several of the most popular stationary phases commonly used in SPE devices contain materials that can retain organic species via adsorption. Very hydrophobic phases have the problem of de-wetting when large amounts of water samples are passed over them. This process also destabilizes the stationary phase bed so that efficiency is decreased. In addition very polar organic species do not retain well. The SolEx HRP phase is designed for fast and easy pre-concentration of contaminants prior to analysis. The SPE phase is comprised of divinylbenzene polymer with a hydrophilic bonded layer that provides a stable resin bed with no de-wetting even with 100% aqueous mobile phases. This resin shows excellent retention properties from polar to more hydrophobic analytes. This phase is provided in two 20 x 2.1 mm I.D. formats: a cartridge for HPLC system with pressures up to 600 bar and a RSLC column for pressures up to 800 bar. The convenient cartridge style is used in a holder and easily exchanged when necessary. The RSLC column style uses stainless steel hardware and is suitable for high pressure RSLC applications. RSLC Column

5 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 4 of 15 SECTION 2 OVERVIEW AND USAGE 2.1. Overview This manual describes recommended automated SPE procedures and examples of use for SPE cartridge and RSLC SPE column. A few minutes of pre-washing can be accomplished in the LC system on startup so manual cleaning is not necessary. Cartridge/ Columns Functional Group(s) Table 1 Recommended Cartridge Applications Mode of Use Typical example Applications SPE Hydrophilic Divinylbenzene Reversed Phase π-π interaction Concentration of pharmaceuticals and pesticides Table 2 SPE Products Characteristics Cartridge Type 2.1 x 20 mm SST/PEEK Column Type 2.1 x 20 mm SST Particle size µm Resin amount 150 mg ph stability 0-14 Table 3 Operating Conditions Parameter Range Preferred Flow rate ml/min 2 ml/min Solvent content 0-100% 0-100% Solvent type Acetonitrile, methanol, other ACN, MeOH tested Cartridge Backpressure bar Up to 600 bar Columns Backpressure bar Up to 800 bar

6 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 5 of System Configuration and experimental workflow Optimum performance is achieved when the SolEx HRP cartridge / column is used in the valve, and the sample is loaded directly onto the cartridge / column followed by elution of the retained analytes onto an analytical column. The SolEx HRP can be used with one valve and an autosampler (i.e. WPS autosampler with an injection valve) or with two independently controlled valves with an AS-DV or AS-HV high volume autosampler (no switching valve, but with an internal peristaltic pump to load sample to the injection loop in the pull mode). The configuration shown in Figure 1 can be accomplished on any system with two independently controlled two-position, six-port valves (two valves both from the column compartment or one from the column compartment, one from the autosampler) and two pumps; sample volume is controlled by the autosampler and an injection loop. Figure 1 One valve and an autosampler (with an injection valve) control of sample volume (sample loading and concentration) or Column

7 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 6 of 15 Figure 2 Flow scheme for automated online SPE-LC Sample Loading Sample Transfer Separation And Concentration Figure 2 shows the typical setup for on-line solid phase extraction liquid chromatography (SPE-LC). The experimental workflow contains the following steps: 1) Sample loading and concentration (left): the sample is injected and transferred to the SPE column with the loading pump. The sample matrix is flushed to waste, while the analytes are retained on the SPE column. At the same time the analytical LC column is equilibrated with the analytical pump. 2) Sample transfer (middle): After the sample matrix is flushed to waste, the six-port valve is switched to a position that couples the SPE cartridge / column with the analytical LC column, and the analytes are transferred. 3) Separation (right): After the transfer, the six-port valve is returned to its original position While the analytes are separated on the analytical LC column, the SPE cartridge /column can be re-equilibrated with the mobile phase on the loading pump. Note that flow across the SPE cartridge / column to the analytical column should be in the reverse direction to the flow across the SPE column when it is being loaded. This minimizes peak broadening in the analysis Use of SPE Cartridges SolEx online SPE phase is designed for fast and easy preconcentration of contaminants from water sample prior to HPLC analysis. The cartridge / column is placed in the valve to automatically concentrate the analytes of interest and eliminate the matrix. SolEx HRP cartridges / column generates less then 100psi backpressure with a flow rate of 1mL/min of DI water. It can be used with wide ph compatibility (0-14) and wide organic solvent content (0-100%). SolEx HRP cartridges/columns have been tested with up to 1L sample volume.

8 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 7 of Condition the SPE Cartridge / Column The SPE cartridge / column is shipped in DI water. When a new cartridge / column is used for the first time, it should be washed thoroughly with the mobile phase (e.g., for 10 min at 1mL/min). When switching to a new mobile phase, make sure that the new mobile phase is compatible with the previous mobile phase in the cartridge / column to avoid clogging due to precipitation. The cartridge / column should be fully conditioned before any injection is made Storage Both cartridges and columns can be stored in the 1/99 to 100/0 v/v DI water/acetonitrile (or methanol) for long term storage Standard SolEx HRP Use Conditions The SolEx HRP SPE cartridge format is a 2.1 x 20 mm I.D stainless steel cartridge body used with a cartridge holder for easy installation in an HPLC system. The cartridges contain approximately 0.15 g of resin. Depending on the exact chemistry and types of samples treated, some cartridges can be regenerated. The SolEx HRP SPE column format is a 2.1 x 20 mm I.D stainless steel (no holder is required). The column contains approximately 0.15 g of resin. Depending on the exact chemistry and types of samples treated, some columns can be regenerated Online SPE and separation of phenols The SolEx HRP cartridge/ column can be used for a wide variety of samples. For example, the presence of phenols commonly used pharmaceuticals and pesticides in water supply are of high interest and methods are in development to provide highthroughput screening using SPE-LC-MS/MS methodologies. Figure 1 demonstrates online SPE and separation of phenols in deionized water. Figure 1 Online SPE and separation of eleven common phenols in deionized water Peaks: µg/l 1. Phenol nitrophenol chlorophenol nitrophenol ,4-dimethylphenol ,4-dinitrophenol chloro-3-methylphenol ,4-dichlorophenol ,6-dinitro-2-methylphenol ,4,6-trichlorophenol Pentachlorophenol 50

9 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 8 of 15 Chromatographic conditions: SPE column: SPE-HRP cartridge, 14µm, 2.1X20mm Analytical Column: Acclaim PA, 3µm, 2.1X150mm Flow rate: 210µL/min Injection Volume: 10mL Temperature: 25 C Detection: UV, 280nm, MS Eluent: A: 25mM HAc/NH 4 Ac (1.45:1, v/v), B: Acetonitrile Gradient: Time A% B% The method described in Figure 1 was applied to Sunnyvale tap water samples extracts, which demonstrated good recovery ranging from 5ng to 225ng as shown in Table 4. % Recovery COMPOUNDS 500ng/L 10ug/L 22.5ug/L ESI-MS/MS ESI-MS/MS, UV UV 2,4-dinitrophenol 88.3% 91.4%* 92.5% phenol Not detected 112.6% 86.5% 4-nitrophenol 100.0% 96.6% 92.8% 2-methyl-4,6-dinitrophenol 81.8% 110.0%* 98.0% 2-chlorophenol Not detected 110.7% 102.8% 2-nitrophenol 112.9% 102.7% 103.0% 2,4-dimethylphenol Not detected 95.1% 94.3% 4-chloro-3-methylphenol 92.8% 99.7% 96.2% 2,4-dichlorophenol 111.7% 103.7% 95.1% 2,4,6-trichlorophenol 92.1% 113.0% 96.3% Pentachlorophenol 94.6%** 98.7%** 97.8% *determined by ESI-MS/MS **determined by Q1 only Table 4: Recovery of phenols in Sunnyvale tap water: recovery% calculated by comparing the area responses of phenols spiked in Sunnyvale tap water to the same sample spiked in deionized water.

10 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 9 of Online SPE and separation of endocrine disruptive compounds Endocrine disruptive compounds in sea water are another environmental concern. It has been reported that there is global contamination of sea sand and sea water with the endocrine disruptor bisphenol A. Figure 2 shows the separation of bisphenol A, β-estradiol and estrone, using the SolEx HRP cartridge for easier preconcentration. Lower detection limit can be obtained using large injection volume. Figure 2 Online SPE-LC of endocrine disruptors in deionized water, 2% sodium chloride, and half moon bay seawater Peaks: µg/l 12. Bisphenol A β-estradiol Estrone Chromatographic conditions: SPE column: Analytical Column: Flow rate: Injection Volume: Temperature: Detection: Eluent: SolEx HRP cartridge, 12µm, 2.1X20mm Acclaim PA, 3µm, 2.1X150mm 300µL/min 10mL 25 C UV, 210nm, A: water B: Acetonitrile C: 100mM ph 5.4 ammonium acetate

11 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 10 of 15 Gradient: Time A% B% C% Recovery of these three endocrine disruptive compounds in 2% sodium chloride and seawater collected at half moon bay are calculated by comparing to the area responses on analytes in deionized water. Analyte, 5 ppb 2% NaCl Seawater Bisphenol A 98.01% 97.18% β-estradiol 93.81% 93.39% Estrone % 97.81% Table 5: Recovery of endocrine disruptive compounds in 2% sodium chloride and half moon bay seawater.

12 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 11 of Online SPE and separation of triclosan in soapwater Triclosan is a powerful antibacterial and antifungal agent. It is an ingredient added to many consumer products to reduce or prevent bacterial contamination. It may be added to antibacterial soaps and body washes, toothpastes, and some cosmetics products regulated by the FDA. Triclosan safety is currently under review by the FDA. Based on recent studies that seem to indicate it causes endocrine disruption in the body and leads to the emergence of drug-resistant "super" bacteria. Figure 3 Online SPE-LC of triclosan in deionized water, % sodium dodecylbenzene sulfonate, and 1/500 antibacterial hand soap contains 0.15% triclosan Chromatographic conditions: SPE column: Analytical Column: Flow rate: Injection Volume: Temperature: Detection: Eluent: SolEx HRP cartridge, 12µm, 2.1X20mm Acclaim PA, 3µm, 2.1X150mm 300µL/min 10mL 25 C UV, 210nm, A: water B: Acetonitrile C: 100mM ph 5.4 ammonium acetate Gradient: Time A% B% C%

13 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 12 of 15 SECTION 3 APPENDIX A. EXAMPLE CHROMELEON PROGRAM, DUAL INJECTION VALVES IN ULTIMATE-3000 DC COLUMN COMPARTMENT WITH AS-HV The following steps in a PGM will load a loop, perform the sample preparation, load the SPE cartridge, wash the SPE cartridge, transfer the analytes from SPE column to the analytical column, and start the analysis. Both valves are installed in an UltiMate-3000 TCC column compartment. Valve nomenclature follows the default conventions of the Chromeleon Server Configuration. Column_A.SystemPressure = "LoadingPump" Column_B.SystemPressure = "MicroPump" LoadingPump.Pressure.LowerLimit = 0 [psi] LoadingPump.Pressure.UpperLimit = 5076 [psi] LoadingPump.MaximumFlowRampDown = 500 [µl/min²] LoadingPump.MaximumFlowRampUp = 500 [µl/min²] LoadingPump.%A.Equate = "%A 2mM HCOOH" LoadingPump.%B.Equate = "%B ACN" LoadingPump.%C.Equate = "%C " MicroPump.Pressure.LowerLimit = 0 [psi] MicroPump.Pressure.UpperLimit = 5076 [psi] MicroPump.MaximumFlowRampDown = 500 [µl/min²] MicroPump.MaximumFlowRampUp = 500 [µl/min²] MicroPump.%A.Equate = "%A 25mM HAc/NH4AC" MicroPump.%B.Equate = "%B ACN" MicroPump.%C.Equate = "%C" NeedleHeight = RinseVolume = Sampler.Flow = Sampler.Pressure.LowerLimit = Sampler.Pressure.UpperLimit = 10 [mm] [ml] 2.00 [ml/min] 0 [psi] 3000 [psi] Data_Collection_Rate = [Hz] Rise_Time = 2.00 [s] Range = 6 Smoothing = None UV_VIS_1.Wavelength = 2 UV_VIS_1.Bandwidth = UV_VIS_1.RefWavelength = Off UV_VIS_1.RefBandwidth = UV_VIS_2.Wavelength = 254 [nm] UV_VIS_2.Bandwidth = UV_VIS_2.RefWavelength = Off UV_VIS_2.RefBandwidth = UV_VIS_3.Wavelength = 280 [nm] UV_VIS_3.Bandwidth = UV_VIS_3.RefWavelength = Off UV_VIS_3.RefBandwidth = UV_VIS_4.Wavelength = 200 [nm] UV_VIS_4.Bandwidth =

14 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 13 of 15 UV_VIS_4.RefWavelength = Off UV_VIS_4.RefBandwidth = UV_VIS_5.Wavelength = 225 [nm] UV_VIS_5.Bandwidth = UV_VIS_5.RefWavelength = Off UV_VIS_5.RefBandwidth = 50 [nm] 3DFIELD.RefWavelength = 220 [nm] 3DFIELD.RefBandwidth = 50 [nm] ValveLeft = 6_1 ; this valving directs loading water through the injection loop, the SPE cartridge to waste; ValveRight = 6_1 ; this valving places SPE cartridge on line with eluent and the analytical column; 3DFIELD.MinWavelength = 3DFIELD.MaxWavelength = 3DFIELD.BunchWidth = TCC3x00_RELAY_2.State 190 [nm] 300 [nm] Off Autozero Wait AZ_Done MicroPump.Flow = 210 [µl/min] MicroPump.%B = 30.0 [%] LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 0.0 [%] Wait ColumnOven.Ready and MS.Ready Inject ;this Inject command of AS-HV autosampler includes the rinse of autosampler and injection loop with DI water, pumps sample through the autosampler to the injection loop using the internal peristaltic pump of AS-HV autosampler Position = GotoPosition R0 ;MS Data Acquisition On TCC3x00_RELAY_2.Duration = 2.00 MicroPump.Flow = 210 [µl/min] MicroPump.%B = 30.0 [%] LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 0.0 [%] ValveLeft = 1_2

15 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 14 of 15 ; this valving switch directs loading water from the loading pump through the injection loop, the SPE cartridge to waste; this step transfer the sample from injection loop to the SPE cartridge, pre-concentrate and remove the matrix; LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 0.0 [%] UV_VIS_1.AcqOn UV_VIS_2.AcqOn UV_VIS_3.AcqOn UV_VIS_4.AcqOn UV_VIS_5.AcqOn 3DFIELD.AcqOn ValveLeft = 6_1 ValveRight = 1_2 ; this right valving switch directs loading eluent from the micro pump through the SPE cartridge to the analytical column; this step transfer the sample from SPE cartridge to the analytical column for separation; PrepareNextSample LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 90.0 [%] MicroPump.Flow = 210 [µl/min] MicroPump.%B = 30.0 [%] ValveRight = 6_1 ; this valving switch directs eluent from the micro pump through the analytical column; this step switch the SPE cartridge offline for cleanup; LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 90.0 [%] LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 0.0 [%] LoadingPump.Flow = 2000 [µl/min]

16 Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 15 of 15 LoadingPump.%B = 0.0 [%] LoadingPump.Flow = 210 [µl/min] LoadingPump.%B = 0.0 [%] MicroPump.Flow = 210 [µl/min] MicroPump.%B = 75.0 [%] LoadingPump.Flow = 2000 [µl/min] LoadingPump.%B = 0.0 [%] MicroPump.Flow = 210 [µl/min] MicroPump.%B = 75.0 [%] ;MS Data Acquisition Off UV_VIS_1.AcqOff UV_VIS_2.AcqOff UV_VIS_3.AcqOff UV_VIS_4.AcqOff UV_VIS_5.AcqOff 3DFIELD.AcqOff End

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for

More information

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water Chen Jing, 1 Dai Zhenyu, 1 Xu Qun, 1 Liang Lina, 1 and Jeffrey Rohrer 2 1 Thermo Fisher Scientific, Shanghai, People s

More information

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) IonSwift MAC-100 & MAC-200 Product Manual Page 1 of 16 PRODUCT MANUAL for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) MAC-100, 0.5 x 80mm (P/N 074702)

More information

Oasis HLB Cartridges and 96-Well Plates

Oasis HLB Cartridges and 96-Well Plates CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION

More information

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High-Throughput 3-D Chromatography Through Ion Exchange SPE High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample

More information

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water Online SPE-LC-APCI-MS/MS for the Determination of Steroidal ormones in Drinking Water presented by Paul Fayad, Ph.D. Candidate under the supervision of Sébastien Sauvé, Ph.D. Department of Chemistry paul.fayad@umontreal.ca

More information

Dionex IonPac AS19-4µm

Dionex IonPac AS19-4µm Total Thermo Scientific Dionex IonPac AS9-4µm Column Product Manual P/N: September 203 Part of Thermo Fisher Scientific Product Manual for Dionex IonPac AS9-4µm Column Dionex IonPac AG9-4µm Capillary Guard

More information

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract

More information

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo

More information

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac.

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac. SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 i.chianella.1998@cranfield.ac.uk Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information

Purification of reaction mixtures using flash chromatography.

Purification of reaction mixtures using flash chromatography. Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?

More information

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK Background Unilabs YBS are a bioanalytical CRO based in York (Uk) Copenhagen

More information

Automation of Sample Preparation in Ion Chromatography

Automation of Sample Preparation in Ion Chromatography Automation of Sample Preparation in Ion Chromatography Praha, nd October 04 Ing. Roman Repáš ACO Sales Manager (IC and SP) Agenda Thermo Scientific Dionex Sample Preparation Products Automation of Sample

More information

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Automation of Solid Phase Extraction and Column Chromatographic Cleanup Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines

More information

The Theory of HPLC. Gradient HPLC

The Theory of HPLC. Gradient HPLC The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims

More information

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS Summary: Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS UCT Part Numbers: CUNAX226 - Clean-Up C8+NAX, 2mg/6mL BETA-GLUC- ml Beta-Glucuronidase Enzyme, liquid form SLAQ1ID21-3UM -

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

A Novel Approach to Low Volume Sample Preparation

A Novel Approach to Low Volume Sample Preparation A Novel Approach to Low Volume Sample Preparation Tony Edge, Jon Bardsley, Ken Meadows, Luisa Pereira International Symposium on Chromatography Salzburg, Austria September 2014 1 The world leader in serving

More information

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE Solid Phase Extraction Products PAGE: 1 Introduction of Solid Phase Extraction (SPE) SPE has been used increasingly in chemical analysis and purification broadly, and become the most popular technology

More information

Innovative vs Traditional

Innovative vs Traditional And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late

More information

ChromQuest 5.0 Chromatography Data System

ChromQuest 5.0 Chromatography Data System ChromQuest 5.0 Chromatography Data System User Guide for the Surveyor LC CHROM-97257 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor and ChromQuest are trademarks

More information

Determination of Calcium and Magnesium in Brine

Determination of Calcium and Magnesium in Brine Application Note Determination of Calcium and Magnesium in Brine INTRODUCTION To prevent membrane poisoning, new membrane technology in chlor-alkali cells requires feed brine that is relatively free of

More information

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study Application Update Now sold under the Thermo Scientific brand Separation of Peptides from Enzymatic Digestion on Different claim Columns: A Comparative Study INTRODUCTION Separation of peptides which can

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

Extraction to Injection in a Single Process

Extraction to Injection in a Single Process Extraction to Injection in a Single Process MEPS Fast Miniaturized SPE Save hours in sample preparation Semi or fully automate to improve workflow and increase productivity Reduce solvent usage and sample

More information

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for

More information

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml GE Healthcare Life Sciences Instructions 71-7146-00 AI Ion Exchange Columns RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml Introduction RESOURCE Q and S are pre-packed columns for separating biomolecules

More information

Affi-Prep Protein A Matrix Instruction Manual

Affi-Prep Protein A Matrix Instruction Manual Affi-Prep Protein A Matrix Instruction Manual Catalog Numbers 156-0005 156-0006 Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules, CA 94547 LIT-230 Rev B Table of Contents Section 1 Introduction...1

More information

columns IonPac CS18 Cation-Exchange Column

columns IonPac CS18 Cation-Exchange Column columns IonPac CS Cation-Exchange Column The IonPac CS is a cation-exchange column of moderate capacity and hydrophobicity, recommended for isocratic and gradient separations of polar amines such as alkanolamines,

More information

INSTRUCTIONS 56-1190-98. Edition AC

INSTRUCTIONS 56-1190-98. Edition AC Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography

More information

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS D. Loeffler 1, M. Ramil 1, T. Ternes 1, M. Suter 2, R. Schönenberger 2, H.-R. Aerni 2, S, König, A. Besa,

More information

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application

More information

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler

More information

EQuan MAX Getting Connected Field Service Guide

EQuan MAX Getting Connected Field Service Guide EQuan MAX Getting Connected Field Service Guide This guide provides procedures to connect the various components for the Thermo Scientific EQuan MAX automated high-throughput LC-MS system. Contents Hardware

More information

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid

More information

Overview. Purpose. Methods. Results

Overview. Purpose. Methods. Results A ovel Approach to Quantify Unbound Cisplatin, Carboplatin, and xaliplatin in Human Plasma Ultrafiltrate by Measuring Platinum-DDTC Complex Using LC/M/M Min Meng, Ryan Kuntz, Al Fontanet, and Patrick K.

More information

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box

More information

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup by Andrew J. Alpert PolyLC Inc./ 9151 Rumsey Road, ste.

More information

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1. Application Note Determination of Amino acids by UHPLC with automated PA- Derivatization by the Autosampler Category Bio Analysis Matrix - Method UHPLC Keywords Proteinogenic Amino acids, Canonical Amino

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic

More information

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Thermo Scientific Syncronis HPLC Columns. Technical Manual Thermo Scientific Syncronis HPLC Columns Technical Manual Thermo Scientific Syncronis HPLC Columns When developing a new method, one of the most important goals for the chromatographer is to achieve a

More information

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers Automation, sample preparation Autosamplers for Ion Chromatography Dionex AS-AP Autosampler Advanced Features Perform full-loop, partial-loop,

More information

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary Application Note Purifying common light-chain bispecific antibodies using MCSGP Category Matrix Method Keywords Analytes ID Continuous chromatography, biochromatography Antibodies MCSGP Bispecific antibody,

More information

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische

More information

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird

More information

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites Carmen T. Santasania and David S. Bell SUPELCO, 595 North Harrison Road, Bellefonte, PA 16823 T404045 GUS Abstract

More information

Chemical analysis service, Turner s Green Technology Group

Chemical analysis service, Turner s Green Technology Group Chemical analysis service, Turner s Green Technology Group Hourly costs, Academic collaborations leading to co-publications: 627 SEK/hr (excl. VAT) Hourly costs, Industry/Academic collaborations, no publications:

More information

Materials for Pharmaceutical Manufacturing

Materials for Pharmaceutical Manufacturing Materials for Pharmaceutical Manufacturing GRACE WHITEPAPER Vydac 150HC Purification Media Greater Loading Capacity and Resolution for Improved Productivity in Peptide Purification Technical Development:

More information

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities ICMS and LCMS Determination of Ionic Liquids, Counterions, and Impurities Leo Wang, Detlef Jensen, and William Schnute Dionex Corporation, Sunnyvale, CA, USA; Dionex Corporation, Olten, Switzerland INTRODUCTION

More information

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC The Essential CHROMacademy Guide Mobile Phase Optimization Strategies for Reversed Phase HPLC Webcast Notes Type your questions in the Submit Question box, located below the slide window You can enlarge

More information

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation PURIFICATION Preparative Chromatography Modular Solutions from Manual Systems to Full Automation PREPARATIVE CHROMATOGRAPHY SOLUTIONS Lab scale Scale Up Reverse Phase Medicinal Chemistry Natural Products

More information

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual Catalog numbers 780-1070 780-1650 Please read these instructions before you use ENrich SEC high-resolution size exclusion

More information

SUCRALOSE. White to off-white, practically odourless crystalline powder

SUCRALOSE. White to off-white, practically odourless crystalline powder SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA

More information

Unique Bonding Chemistry

Unique Bonding Chemistry columns Acclaim HPLC Columns Reversed-phase silica columns for pharmaceutical, nutraceutical, environmental, food, and life science applications in HPLC. High hydrophobicity, low polarity phases LC/MS

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes Technical Note 64 Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes INTRODUCTION The AS Autosampler is enhanced with new features to speed throughput and simplify sample

More information

Biocides main groups

Biocides main groups Analytical challenges for the analysis of biocides in aqueous and solid environmental matrices Arne Wick, Kathrin Broeder, Michael Schluesener, Thomas Ternes Federal Institute of Hydrology (BfG), Koblenz,

More information

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT AppNote 9/2013 Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides Oscar G. Cabrices Gerstel, Inc., 701 Digital Dr. Suite J, Linthicum, MD 21090, USA

More information

This study was performed in collaboration with CT Laboratories of Baraboo, WI, USA.

This study was performed in collaboration with CT Laboratories of Baraboo, WI, USA. Automated Gel Permeation Chromatography (GPC) Clean-up of Soil Extracts Prior to Analysis for Semivolatile Organic Compounds by GC/MS (USEPA Method 8270) Keywords: Automated GX-271 GPC Clean-up System,

More information

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) Method OIV-MA-AS313-22 Type II method Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) 1. Introduction

More information

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation Craig Aurand 1, David Bell 1, Anders Fridstrom 2, and Klaus Buckendahl 2 1 Supelco, Div.

More information

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Smartline HPLC by design

Smartline HPLC by design HPLC SMB Osmometry Smartline Systems Smartline HPLC by design Smartline high performance liquid chromatography instruments are designed to provide reliable separation solutions for routine tasks such as

More information

Environmental Analysis Using the ICS-3000 Ion Chromatography System

Environmental Analysis Using the ICS-3000 Ion Chromatography System Environmental Analysis Using the ICS- Ion Chromatography System Ion chromatography (IC) is well established as a routine method for the analysis of ionic analytes in environmental samples. IC has been

More information

Solid Core Technical Compendium

Solid Core Technical Compendium 150-C4 150-C18 Phenyl-Hexyl XL-C18 PFP 150-Amide-HILIC C0 Urea-HILIC Phenyl-X HILIC Polar Premium C8 XL-C8 aq C18 RP-MS Solid Core Technical Compendium Want fast, high-resolution separations, plus a range

More information

RapidFire for High Throughput Screening in early Drug Discovery

RapidFire for High Throughput Screening in early Drug Discovery RapidFire for High Throughput Screening in early Drug Discovery Fast but do we stay on track? Markus Trunzer ADME Profiling in Basel High analytical burden ~8 000 compounds per year by HT-Sol and HT-Perm

More information

HPLC Column Comparison Screening Study for Reversed Phase Columns

HPLC Column Comparison Screening Study for Reversed Phase Columns HPLC Column Comparison Screening Study for Reversed Phase Columns Carmen T. Santasania, Eric M. Snyder, Matilal Sarker, and Tracy L. Ascah Supelco, 595 North Harrison Road, Bellefonte, PA 16823, USA T403058

More information

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Carl Fisher and Linda Lopez Thermo Fisher Scientific, Sunnyvale,

More information

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K =

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K = Theory of SPE 1 SPE Nonequilibrium,, exhaustive removal of chemical constituents from a flowing liquid sample via retention on a contained solid sorbent and subsequent recovery of selected constituents

More information

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection Application Note Food Testing & Agriculture Authors Edgar Naegele and Thomas

More information

Protocol: HPLC (amino acids)

Protocol: HPLC (amino acids) Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain

More information

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Chapter 28: High-Performance Liquid Chromatography (HPLC) Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion

More information

[ Care and Use Manual ]

[ Care and Use Manual ] The Waters GPC Cleanup System uses two Envirogel GPC Cleanup Columns to perform routine cleanup of environmental samples as specified by EPA Method 3640A, GPC Cleanup. The columns, 19 x 150 mm and 19 x

More information

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS AppNote 1/2012 Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS Oscar G. Cabrices, Fred D. Foster, John R. Stuff, Edward

More information

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE User Guide for Reversed-Phase Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE Notice The information in this document is subject to change without notice and should not be construed as a commitment

More information

Solid Phase Extraction for Water Analysis. presented by

Solid Phase Extraction for Water Analysis. presented by Solid Phase Extraction for Water Analysis presented by Dr. Bernd Thierfelder Outline 1. Introduction in SPE 2. Retention Mechanisms / Sorbent Selectivity 3. strata -X for Water Analysis 4. Applications

More information

[ Care and Use Manual ]

[ Care and Use Manual ] Analytical columns and cartridges i. Introduction Waters offers a large selection of analytical columns and cartridges packed with silica-based packing materials. Follow this instruction sheet to obtain

More information

LC Application Note. www.palsystem.com

LC Application Note. www.palsystem.com LC Application Note Pain Management & Drugs of Abuse Measured in Urine or Oral Fluid Measuring all the drugs at all the relevant concentrations in a single method / workflow using an ITSP solution for

More information

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs

More information

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in uman Serum Technical verview Clinical Research Authors Anthony Macherone, Ph.D. Agilent Technologies,

More information

PRODUCT INFORMATION Chromalite resins for reverse-phase chromatography, adsorption and SPE

PRODUCT INFORMATION Chromalite resins for reverse-phase chromatography, adsorption and SPE PRODUCT INFORMATION Chromalite resins for reverse-phase chromatography, adsorption and SPE Presents an overview of the advantages of Purolite s Chromalite polymeric resins over silica for the purification

More information

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry. IFC A new perspective i l ifi ti Medicinal Chemistry p p CombiChem Compound Isolation Autopurification Drug Discovery y y q p p p p g p Single softw FractPAL software plug-in for Agilent ChemStation The

More information

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC Mackenzie Ree and Erik Stoa Department of Chemistry, Concordia College, 901 8 th St S,

More information