B
BLOCK
GIFT FIXTURE FLORAL ROUNDER
REVISION: I. GENERAL CONTRACTOR'S RESPONSIBILITIES: 0 OLS OTS 0 CONTROL SECTION RA SSC 0 STS CO SA DTS 0 0 CONTROL SECTION RA SA DTS CONTROL SECTION RA 3 0 0 SSC 0 0 SSC SA DTS 0 CONTROL SECTION RA SA DTS 0 STS STS STS 0 SSC 0 ( IN ELECTRICAL ROOM/AREA ADJACENT TO EMS IFP PANEL SHOWN BELOW II. a. Read Dollar Tree Documentation Package and distribute to mechanical and electrical contractors. b. Coordination with the electrical and mechanical contractors to be present during the entire remote commissioning for a twohour period, via telephone, for a complete commissioning of the EMS as deemed by Teletrol Systems Commissioning Agent. c. Remote EMS commissioning shall be scheduled hours prior to requested commissioning date. Contact Teletrol Systems Inc., at 993, and submit survey for scheduling of remote EMS commissioning. d. Confirm that the mechanical and electrical contractors have completed the Teletrol Survey form. Confirm Teletrol Survey form is FAXED/EMAILED to Teletrol National Account Team at (03) 7 or Teletrol.surveys@philips.com. ELECTRICAL CONTRACTOR'S RESPONSIBILITIES: a. Provide labor and installation material, as required, for a complete and operational Teletrol Systems Inc. EMS for this Dollar Tree Stores location. b. Receive and store all Teletrol Systems Inc. material in a safe and secure place until the EMS installation has been completed. c. The following equipment will be supplied by Teletrol Systems Inc., and installed by the Electrical Contractor: i. Outdoor Light and Temperature Sensor Assembly (OSA) ii. Lighting Contactor Panel (IFP Panel) iii. Manager Timed Override panel iv. Seven Foot Ethernet Patch Cable (CAT) vi. Seven Foot Phone Patch Cable vii.modem & mounting kit d. Review the entire set of plans, perform a job site survey and inventory the Teletrol Systems Inc. equipment to ensure the proper equipment has been ordered and received for a complete and operational Teletrol Systems Inc. EMS. e. If any material is missing or additional equipment, (e.g. lighting contactors) is required, immediately call Teletrol Systems Inc. at 993 to request an order. f. Electrical Contractor shall verify number of roof top units and number of controlled lighting circuits against the design and report discrepancies that cannot be resolved in the field, to the Teletrol Operations Manager @ 993 for further instruction. g. All EMS cables are to be installed per National and Local codes. It is the Electrical Contractor's responsibility to determine if national and local codes permit class cables to be installed exposed within the building structure or if a full conduit system is required. h. EMT connectors and bushings are to be installed at the top of every conduit sleeve to protect EMS cables from abrasions. All cables are to be clearly and distinctly labeled at both ends. i. Perform all work in accordance with all national, state, or local codes for this project. j. Coordinate the EMS installation with the Mechanical Contractor to avoid any interference that may delay progress during construction. k. Furnish and install all required conduit, boxes, wire ways, fittings, straps, hangers and wiring for a complete and operational EMS as required. l. Coordinate with the Mechanical Contractor for locations when running communication and sensor wires. m.electrical Contractor shall coordinate with the phone company personnel to have an additional RJ phone jack (connected to the store's primary phone line) installed within 3'0 of the contactor panel. The phone jack shall be connected to the store phone number. Electrical Contractor shall connect the phone line patch cord, provided by Teletrol Systems Inc. from the RJ phone jack to the esc controller's modem. n. Bailiwick shall install an Ethernet cable run from the esc Controller to the (HUB) under Cash Register #. Bailiwick will terminate both ends of the cable, test cable for proper wiring, plug one end of the Ethernet cable into the (HUB) and terminate the other end of the Ethernet Cable into a RJ jack that serves the esc Controller. o. Furnish and install a dedicated 0 VAC circuit for the IFP Panel. i.label: DO NOT TURN OFF / IFP EMS ii. Confirm wiring is completed as per Documentation Package before applying power. Improper wiring will cause damage to equipment. p. Furnish and install a 3pole, 0 amp breaker/disconnect at the main distribution panel (MDP) for phase loss monitor power. i.label: DO NOT TURN OFF / PHASE FAILURE ii. Confirm wiring is completed as per Documentation Package before applying power. Improper wiring will cause damage to equipment. q. Mount the Remote Override Panel (ROP) in Manager's Office Area, see EMS drawings for details. r. Connect the Ethernet patch cord provided from the esc Controller to the RJ Ethernet jack. If the Ethernet jack is not yet in place, connect one end of the patch cord to the esc System Controller, coil and tape the other end of the cord to the conduit for future connection. s. Mount the contactor panel adjacent to the electrical panels. Install the lighting circuit home runs from the fixtures straight to the load side of the contactors. Install the circuits from the line side of the contactors to each breaker. i. The lighting loads will be configured as follows:. Employee lights: 0% of sales lighting and 00% of offices, lounge, stock room, and electrical room.. Customer lights: remaining 0% of sales 3. Exterior lights: building and pylon signs. Parking lot lights: pole lights t. Mount the Outdoor Sensor Assembly (OSA) on the roof top unit that resides closest to the esc System Controller. Mount the device on a rigid riser and 'LB' to back of Assembly, 3 feet above the roof top unit, facing north, away from the combustion heat blower and condenser fan. u. Electrical Contractor is responsible for installing and terminating the Teletrol Systems Inc. communication trunk in a daisy chain fashion from the esc Controller to each of the SimpleSTAT Thermostat Controls. (see EMS drawings for requirements) A. TELETROL SYSTEMS INC. WILL VERIFY THE PROPER OPERATION OF THE FOLLOWING ITEMS BY EXERCISING THE CONTROLLED LOAD. a. If any end unit (e.g. lighting, roof top unit, supply air fan) cannot be operated for mechanical or electrical reasons, Teletrol Systems Inc. will verify the proper operation of the control devices (e.g. contactors, discrete I/O) leading up to the unit. b. Timed operation of lighting loads employee, customer, parking, and signs. c. Outside light level control of lighting loads parking, signs, and security. d. Operation of HVAC unit heating stages, as indoor environment allows. e. Operation of HVAC cooling stages, as indoor and outdoor environments allow. f. Verification of HVAC unit sensor readings space and supply temperatures. g. Timed override operation of lighting and HVAC loads. h. Operation of phase loss monitor HVAC load lockout. i. CO Level on the Sales Floor II. MECHANICAL CONTRACTOR'S RESPONSIBILITIES: a. Provide labor and installation material, as required, for a complete and operational Teletrol Systems Inc. EMS for this Dollar Tree Stores tenant space. b. Mechanical Contractor shall verify number and type of roof top units against the design and report discrepancies that cannot be resolved in the field to the Teletrol Operations Manager @ 993 for further instruction. c. The following equipment will be supplied by Teletrol Systems Inc. and installed by the Mechanical Contractor: i. Remote Duct Temperature Sensor ii. SimpleStat Thermostat Controllers iii. Remote Space Temperature Sensors. Please refer to Down Rod installation instructions for correct placement of Remote Space Temperature Sensors. iv. CO Sensor d. The following services will be supplied by Teletrol Systems Inc.: i. Equipment shipping to the job ii. Preprogramming and downloading of Teletrol Systems Inc. equipment. iii. Telephone technical support at 993. iv. Remote system checkout with installing contractor e. Amended stores only, provide credit back to Dollar Tree Stores Inc. for any equipment and/or labor that has been omitted from the original bid as a result of the EMS installation, i.e.; contactors, relays, thermostats, etc. f. Perform all work in accordance with all national, state, or local codes for this project. g. Coordinate the EMS installation with Electrical Contractor to avoid any interference that may delay progress during construction. h. Install 8/8 cable (MC Supplied) between the SimpleStat Thermostat module and rooftop unit. Terminate R, G, Y, Y, W, and W for control of fan, cooling and heating. Secure the communications cables to the SimpleStat as shown. Provide VAC power to the SimpleStat Thermostat Module from the roof top unit transformer. Power to the controller must be off while terminations are made. i. Mount the remote supply duct temperature sensor of each roof top unit. The remote supply duct temperature sensor should be mounted no closer than six feet from the roof top unit penetration measured along the duct. Install and secure the supply duct temperature sensor wire (8/ Shielded, MC Supplied) to the SimpleStat location and terminate, as shown. j. Mount the Remote Space Temperature per Dollar Tree Stores location criteria, i.e., near zone return air grille and away from supply air drafts or impingement on Ceiling down Rod as shown on Dollar Tree plan detail. Install and secure the Remote Temperature Sensor wire (8/ Shielded, MC Supplied) to the SimpleStat location and terminate. k. Provide a technician for an approximate hour remote telephone checkout with Teletrol Systems Inc. l. If extra equipment exists after installation (e.g. sensors), inform the Teletrol personnel at checkout to arrange for RA # to return the material. m. Coordinate with the Electrical Contractor to verify proper HVAC control during the Teletrol Systems Inc. remote telephone checkout. Provide Electrical Contractor with roof plan layout, showing location of s on the roof. n. Mount the CO sensor per Dollar Tree Stores location criteria, i.e. one sensor in Sales Floor area. Install and terminate sensor's signal wires and power wires as shown on EM. DO NOT CALIBRATE CO SENSOR! FIELD CALIBRATION WILL CAUSE SENSOR FAILURE. o. Install and terminate DCV wires to economizer section of s as shown on EM. If s do not have economizer section, DCV wires do not need to be installed, but CO sensor should still be installed in space. p. Set address and configuration DIP switches on the SimpleStats, as shown in the SimpleStat Installation Note. Once DIP switches are set properly, the SimpleStat will operate /7 as a standalone STAT using the following temperature setpoints; i. Default Cooling Setpoint = 7.0 F ii. Default Heating Setpoint = 8.0 F TELETROL SYSTEMS INC. 8 Commercial Street Manchester, NH 030 FOR REFERENCE ONLY v. Amended stores only, provide credit back to Dollar Tree Stores Inc. for any equipment that has been omitted from the original bid as a result of the EMS installation, i.e.; time clocks, contactors, switches, etc. w. Provide a technician for an approximate hour remote telephone checkout with Teletrol Systems Inc. x. Coordinate with the Mechanical Contractor to verify HVAC control during the Teletrol Systems Inc. remote telephone checkout. y. Upon completion of the installation, the Electrical Contractor will fill in the information below, coordinate with Mechanical Contractor to be present and contact Teletrol Systems Inc. to schedule a remote checkout at 993. If both Electrical EMS IFP (x0x7) 0 VAC IFP POWER CIRCUIT (RE: EM) 0/80 VAC 3ɸ CIRCUIT (RE: EM) (PHASE LOSS) NOTE: CONNECT EXTERNAL MODEM, INCLUDING: RJ FROM WALL CONNECTOR TO 'LINE' OF MODEM DB9 FROM esc80 TO MODEM DB PLUG MODEM INTO 0VAC SERVICE OUTLET IN IFP PANEL SYMBOL SSC DEVICE LEGEND DESCRIPTION SIMPLESTAT CONTROLLER PART # 039 Contractor and Mechanical Contractor are not present, the checkout can not be scheduled. z. If extra equipment exists after installation, the Electrical Contractor will inform Teletrol Systems Inc. personnel at checkout to arrange for RA # to return the material. ST REVIEW RELEASE ACCEPTED RELEASE ACCEPTED RELEASE NOTE 'N' MODIFICATION ROS DTS DUCT TEMPERATURE SENSOR VR MODEM MOUNTING SIMPLESTAT MOUNTING STS SPACE TEMPERATURE SENSOR 79 NOTE 'M' MODIFICATION CO SPACE CO SENSOR KE03 NOTE 'N' & 'O' MODIFICATION ADDED DOOR CONTACT NOTE REMOVED STOCK RM CO REMOVED DOOR MONITOR RJ RJ ETHERNET JACK TELEPHONE JACK CABLE LEGEND OLS OUTDOOR LIGHT SENSOR KE09 KEY SIZE TYPE MFG. MFG. PART # 0 8/ SHIELDED, WINDY # 0030B OTS OUTDOOR TEMPERATURE SENSOR VR7 W.L.L./R.S.R. B.T.B/P.M.B (MOUNTED IN ELECTRICAL ROOM/AREA ADJACENT TO LIGHTING CIRCUIT PANELS) (RE: EM EMS WIRING DETAIL) PLENUM 8/ SHIELDED, PLENUM 8/8 TSTAT, CITY WINDY CITY WINDY # 0030B # 0039 esc80 ebuilding SYSTEM CONTROLLER 03 PLENUM CITY VARIES FIELD INSTALLED WIRING ROS REMOTE OVERRIDE SWITCH 003
R R3 R R7 R R R R8 7 8 9 0 3 7 8 9 30 3 3 33 3 3 3 37 38 TB TB C TB TB3 R R3 R R7 R R R R8 SW SW SW SW SW7 SW8 R R3 R R7 R R R R8 TB TB 3 7 8 9 0 3 R R3 R R7 R R R R8 R R3 R R7 R R R R8 R R3 R R7 R R R R8 3 VOLTAGE ADJ. (VAC) UNBALANCE TRIP NEMA % RESTART (SEC) TRIP DELAY (SEC) LED STATUS REVISION: IFP FACTORY WIRING (RE: INTERFACE PANEL SHEET EM) x 0 x 3 Wire Duct PS VDC POWER SUPPLY F L N G ABC 3 7 8 90 378 A B C F F3 F PFR Motor Saver NOTE: OBSERVE POLARITY WHEN WIRING CO SENSOR SALES FLR CO SENSOR (RE: CO SENSOR WIRING DETAIL EM3) PWR IN OUTPUT L N G L 0VAC SERVICE OUTLET N G F 3A (BLACK) (RED) TR (WHITE) (RED) TELETROL SYSTEMS INC. 8 Commercial Street Manchester, NH 030 A B C TR 9KA 0: VAC 70vA G N L x 3 Wire Duct A A A A EMPLOYEE EMPLOYEE CUSTOMER CUSTOMER LC LC LC LC x 3 Wire Duct SUB NET C 7 7 SW3 SW A R R R3 R R R R7 R8 A A A A A CUSTOMER LC A A EXTERIOR LC3 CR x 3 Wire Duct REMOTE OVERRIDE SWITCH (RE: REMOTE OVERRIDE MOUNTING DETAIL EM3) EMPLOYEE LIGHTS OVERRIDE EXTERIOR LIGHTS OVERRIDE OUTDOOR AIR /LIGHT SENSOR ASSEMBLY (RE: OTS/OLS DETAIL EM3) GRY GRY 3 8 9 FOR REFERENCE ONLY x 3 Wire Duct SUB NET esc CONTROLLER RED BLK 0 esc NETWORK (RE: SIMPLESTAT DETAIL EM3) ST REVIEW RELEASE ACCEPTED RELEASE MODEM/Phase loss changes 7 FUSE LOCATION CHANGE MODIFIED 0VAC CIRCUIT S 8 MODIFIED PHASE MONITOR THREE PHASE POWER FROM ELECTRICAL PANEL Aɸ A Bɸ B R.S.R. B.T.B./P.M.B. Cɸ C ALL WIRING INSIDE DOTTEDLINES REPRESENTS PREWIRED FACTORY PANEL FIELD WIRING KEYNOTE
ON ON REVISION: IFP WIRING TERMINALS (RE: TERMINALS SHEET EM) cool 7 8 heat fan 7 COM COM DI DI REMOTE SENSOR NETWORK AUX SNSR DIG INPUTS 0 POWER GND R G D W W Y Y 9 SPACE TEMPERATURE SENSOR. SEE REMOTE SENSOR MOUNTING DETAIL (EM3). (RE: TELETROL CEILING DOWN ROD INSTALLATION INSTRUCTIONS) (YELLOW) (BLUE) (WHITE) (ORANGE) (GREEN) (BLACK) (RED) Y Y W W G C R REFER TO SIMPLESTAT INSTALLATION GUIDE FOR HEATPUMP CONFIGURATION SWITCHES ALL OTHER WIRING IDENTICAL TO SIMPLESTAT WIRING DETAIL POWER GND R G D O/B W Y Y (YELLOW) (BLUE) (WHITE) (ORANGE) (GREEN) (BLACK) (RED) G HEATPUMP WIRING TERMINALS Y Y W O/B C R TELETROL SYSTEMS INC. 8 Commercial Street Manchester, NH 030 cooler warmer ready WIRING TERMINALS EMPLOYEE LIGHTS 8 SIDE VIEW EXTERIOR LIGHTS REMOTE OVERRIDE SWITCH (RE: EM REMOTE OVERRIDE SWITCH) ACT CEILING & GRID PROVIDE FEET EXCESS SENSOR WIRE ABOVE CEILING TO ACCOMMODATE SENSOR RELOCATION. FOR REFERENCE ONLY 3 /8" NOTCH IN TOP OF TUBE FOR SENSOR WIRE CEILING GRID CLIP (WHITE) FOR STORES LOCATED IN CANADA OR ALASKA, MOUNT ON NORTHEAST SIDE OF BUILDING 3" A.F.F. RED WIRE 8 9 0 TEMPERATURE SENSOR WIRE INSIDE PVC PIPE PROVIDED & INSTALLED BY TENANT'S GC. TEMPERATURE SENSOR WIRE INSIDE PVC PIPE ST REVIEW RELEASE ACCEPTED RELEASE REMOVED DCV NOTES SIMPLESTAT MOUNTING HP DETAIL & OAT DETAIL TEMPERATURE SENSOR DOOR CONTACT DETAIL DOOR CONTACT REVISED DOOR CONTACT REMOVED BLACK WIRE 7'0" AFF HEIGHT VARIES W.L.L./R.S.R. B.T.B./P.M.B. IFP WIRING TERMINALS (RE: esc CONTROLLER SHEET EM) FIELD WIRING KEYNOTE
PWR IN AC/DC OUTPUT REVISION: IFP WIRING TERMINALS (RE: esc CONTROLLER SHEET EM OR DOC3) 'S SERVING SALES FLOOR WIRE TO BE LANDED ON TERMINAL DESIGNATIONS SHOWN BELOW BY MANUFACTURER DAISYCHAINED TO NEXT SERVICING SALES FLOOR R C 7 CARBON DIOXIDE SENSORS (RE: KCDMV MOUNTING DETAIL) SALES FLOOR CO SENSOR VAC/VDC OUTPUT TELETROL SYSTEMS INC. 8 Commercial Street Manchester, NH 030 NOTE: TERMINAL DESIGNATIONS ARE FOR ECONOMIZER ACTUATOR MOTORS. IF 'S DO NOT HAVE ECONOMIZER SECTION OR DO NOT HAVE IAQ/DCV OPTION, THEN DO NOT TERMINATE WIRES AND MAKE NOTE ON SURVEY FORM. KCDWV (RE: CARBON DIOXIDE SENSORS) FRONT VIEW KCDWV (RE: CARBON DIOXIDE SENSORS) BACK VIEW AQ AQ DAMPER MOTOR CARRIER/YORK 'S WIRE TO BE LANDED ON ECONOMIZER BOARD HH3AW00 (W7), AS SHOWN P P Q79C YORK 'S (option ) WIRE TO BE LANDED ON INTERFACE BOARD Q79C AS SHOWN P8 TRANE 'S WIRE TO BE LANDED ON TERMINALS, AS SHOWN 0 TB LENNOX L SERIES 'S WIRE TO BE LANDED ON TERMINAL TB, AS SHOWN IFP PANEL WIRING TERMINALS (RE: esc CONTROLLER SHEET EM) FOR REFERENCE ONLY 9 9 NOTE: INSTALL ADDITIONAL CONTACTOR(S) IN IFP PANEL FOR PERIMETER LIGHTS ST REVIEW RELEASE ACCEPTED RELEASE AMBIENT LIGHT SENSOR MOUNTED ON x BOX SIDE VIEW AMBIENT LIGHT SENSOR MOUNTED ON x BOX FRONT VIEW 3 ACCEPTED RELEASE CO DETAILS FOR ALL STATES MODIFIED ACTUATOR DETAIL ADDED RESPONSIBILITIES MODIFIED REQUIRED WIRE REMOVED STOCKROOM CO ADD OPT'L DAYLIGHT ZONE NOTE: IF ADDITIONAL AMBIENT LIGHT SENSORS ARE REQUIRED, REFER TO DOC MODIFY MIN/MAX CFM AMBIENT LIGHT SENSOR R.S.R. B.T.B./P.M.B. FIELD WIRING KEYNOTE