Manual motor starter MS116



Similar documents
Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Technicaldata General

RM4TG20 three-phase network control relay RM4-T - range V

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: DILM32 10(24V50HZ) Article No.:

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Catalog. Modular DIN rail components Installation contactors

Manual Motor Starter MS 116 up to 16 A Technical Data

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Type: DILM9 10(24VDC) Article No.:

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS25 Screw Clamp Terminal Blocks Feed-through

Technical catalogue. Modular DIN rail components Installation contactors

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Bimetallic Overload Relay Specifications

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

R.C.C.B. s two-pole LEXIC

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Thermistor motor protection

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Analog signal converters CC-E I/I Current / current isolators

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

PSR The compact range Description

Relés e Contatores de Estado Sólido SIRIUS

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Series 8146/5-V37 and Series 8150/5-V37

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

CompactLogix Power Supplies Specifications

Safety automation solutions

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Solid State Timers Type F

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Thermal-Magnetic Circuit Breaker M1-..

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

38 Series - Relay interface modules A

ZS10 Screw Clamp Terminal Block

Safety technique. Emergency stop module BO 5988 safemaster

38 Series - Relay interface modules A

48 SERIES Relay interface modules 10 A

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Pluggable interface relays CR-P Pcb relays

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Plug and Socket Devices CES 63 A Series 8579

RY2 miniature industrial relays

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

5SV Residual Current Protective Devices

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

SMC -3 Specifications

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

MasterINTERFACE 39 Series - Relay interface modules

The complete range of consumer switchboards and switchgear

Power Supplies 3. SDN-P DIN Rail Series

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

7 - Phaseo power supplies and transformers

MasterINTERFACE 39 Series - Relay interface modules

Low Voltage Fuses For Motor Protection

D-Line Contactors, Overload Relays and Accessories

49 Series - Relay interface modules A. Features

EMR measuring and monitoring relays

Low Voltage Products. Switches Automatic Transfer Switches

Digital input modules

Pressure controls, type KP

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Transcription:

Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and protection against short circuit, overload, and phase loss conditions. Manual motor protection saves cost, panel space, and ensures fast and reliable short-circuit protection by reacting within milliseconds. Closecoupling adaptors are available for combination with BB contactors. Description Overload protection trip class 10 Phase loss sensitivity Disconnect function Temperature compensation from -25 +55 C djustable current setting for overload protection Suitable for three- and single-phase application Trip-free mechanism Clear switch position indication ON/OFF pprovals Marks culus UL 508 a CE K CB scheme* E CCC* D GOST-R GOST-F BS* P Lloyd s Register* GL* Order data MS116 screw terminal Setting range Catalog number Trip class Packing unit PCE Weight per PCE kg 0.10...0.16 MS116-0.16 10 1 0.225 0.16...0.25 MS116-0.25 10 1 0.225 0.25...0.40 MS116-0.4 10 1 0.225 0.40...0.63 MS116-0.63 10 1 0.225 0.63...1.00 MS116-1.0 10 1 0.225 1.00...1.60 MS116-1.6 10 1 0.265 1.60...2.50 MS116-2.5 10 1 0.265 2.50...4.00 MS116-4.0 10 1 0.265 4.00...6.30 MS116-6.3 10 1 0.265 6.30...10.0 MS116-10 10 1 0.265 8.00...12.0 MS116-12 10 1 0.265 10.0...16.0 MS116-16 10 1 0.265 16.0...20.0 MS116-20 10 1 0.310 20.0...25.0 MS116-25 10 1 0.310 25.0...32.0 MS116-32 10 1 0.310 DNV* L RMRS* Bureau Veritas* * Note: the marked approvals are still pending for MS116-20...32

Functional description 1 Terminals 1L1, 3L2, 5L3 1 2 Test function 3 Current setting range djustable current setting for overload protection 4 Terminals 2T1, 4T2, 6T3 2CDC241001F0009 2 3 4 pplication The manual motor starters protect the load and the installation against short-circuit and overload. They are three pole protection devices with thermal tripping elements for overload protection and electromagnetic tripping elements for short-circuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads. The manual motor starters have a setting scale in amperes, which allows for direct adjustment of the device without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (i.e., no tripping at 1.2 x I; I = setting current). Operation mode Single-phase operation Three-phase operation Wiring diagram 2 - MS110 Manual Motor Starters

Resistance and power loss per pole Type Setting range Resistance per pole Power loss per pole lower value upper value Ω at lower value W at upper value W MS116-0.16 0.10 0.16 66.00 0.7 1.7 MS116-0.25 0.16 0.25 25.50 0.7 1.7 MS116-0.4 0.25 0.40 10.38 0.7 1.7 MS116-0.63 0.40 0.63 4.36 0.7 1.7 MS116-1.0 0.63 1.00 1.605 0.7 1.7 MS116-1.6 1.00 1.60 0.648 0.7 1.7 MS116-2.5 1.60 2.50 0.272 0.7 1.7 MS116-4.0 2.50 4.00 0.106 0.7 1.7 MS116-6.3 4.00 6.30 0.046 0.7 1.7 MS116-10 6.30 10.0 0.024 0.9 2.4 MS116-12 8.00 12.0 0.016 1.0 2.3 MS116-16 10.0 16.0 0.011 1.1 2.8 MS116-20 16.0 20.0 0.0057 1.5 2.3 MS116-25 20.0 25.0 0.0045 1.8 2.8 MS116-32 25.0 32.0 0.0030 1.9 3.1 Dimensions in mm / inches 1,5 / 0,06" 5,5 / 0,22" 80,1 / 3,15" 70 / 2,76" 43,5 / 1,71" 1,5 / 0,06" 5,5 / 0,22" 79,9 / 3,15" 69,8 / 2,75" 43,3 / 1,7" 90 / 3,54" 1,7 / 0,07" 27,5 / 1,1" 75 / 2,95" 35 / 1,38" 45 / 1,77" 57,8 / 2,3" 97,8 / 3,85" 1,7 / 0,07" 27,5 / 1,1" 75 / 2,95" 35 / 1,38" 45 / 1,77" 57,8 / 2,3" 14 / 0,55" 14 / 0,55" 45 / 1,77" 14 / 0,55" 14 / 0,55" 45 / 1,77" MS116 16 MS116 20 Ø 4,5 / Ø 0,18" 9 / 0,35" 5,4 / 0,21" Ø 4,5 / Ø 0,18" 9 / 0,35" 5,4 / 0,21" 122 / 4,8" 110 / 4,33" 122 / 4,8" 110 / 4,33" 17,5 / 0,69" 17,5 / 0,69" MS116 16 with screw fixing kit FS116 (accessory) MS116 20 with screw fixing kit FS116 (accessory) MS110 Manual Motor Starters - 3

Technical data IEC/EN Data at T = 40 C and at rated values, if nothing else indicated Main circuit 1L1-3L2-5L3 2T1-4T2-6T3 Rated operational voltage U e 690 V a.c. - V d.c. Setting range - thermal overload protection see table Order data on page 1 Rated operational current I e see table below Rated instantaneous short-circuit current setting I i see table below Rated service short-circuit breaking capacity I cs see table Short-circuit breaking capacity and Rated ultimate short-circuit breaking capacity I cu back-up fuses on page 6 Trip class see table Order data on page 1 Rated frequency 50/60 Hz Number of poles 3 Resistance per pole see table Resistance and power loss per pole Power loss per pole on page 3 Isolation data Rated impulse withstand voltage U imp 6 kv Rated insulation voltage U i 690 V Pollution degree 3 Electrical connection MS116 16 MS116 20 Connecting capacity solid 1/2 x 1... 4 mm² 1/2 x 2.5 6 mm² stranded 1/2 x 1... 4 mm² 1/2 x 2.5 6 mm² flexible with ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 1 6 mm² flexible with ferrule insulated 1/2 x 0.75... 2.5 mm² 1/2 x 1 6 mm² flexible without ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 2.5. 6 mm² Stripping length 9 mm 10 mm Tightening torque 0.8 1.2 Nm 2 Nm Connection screw M3.5 (Pozidrive 2 / 5.5 mm) M4 (Pozidrive 2 / 6.5 mm) Type Rated instantaneous Rated operational current l e short-circuit current setting l i MS116-0.16 1.56 0.16 MS116-0.25 2.44 0.25 MS116-0.4 3.90 0.40 MS116-0.63 6.14 0.63 MS116-1.0 11.50 1.0 MS116-1.6 18.40 1.6 MS116-2.5 28.75 2.5 MS116-4.0 50.00 4.0 MS116-6.3 78.75 6.3 MS116-10 150 10 MS116-12 180 12 MS116-16 240 16 MS116-20 300 20 MS116-25 375 25 MS116-32 480 32 4 - MS110 Manual Motor Starters

General data Mechanical durability 10 5 Electrical durability 10 x 10 4 Duty time 100 % Dimensions (W x H x D) see drawing Dimensions on page 3 Weight see table Order data on page 1 Mounting DIN-rail (EN 60715) Mounting position position 1-6 (optional for single mounting) Group Mounting on request Minimum distance to other units same type horizontal 0 mm vertical 150 mm Minimum distance to electrical conductive board horizontal, up to 400 V 0 mm horizontal, up to 690 V > 1.5 mm vertical 75 mm Degree of protection enclosure / terminals IP20 Utilization category ltitude up to 2000 m Maximum operating frequency 170 cycles/h Electromagnetic compatibility Electromagnetic compatibility not applicable Environmental data mbient air temperature Operation open - compensated without derating -25... +55 C open -25... +70 C Storage -50... +80 C Temperature compensation continuous Vibration (sinusoidal) acc. to IEC/EN 60068-2-6 (Fc) 5g / 3... 150 Hz Shock (half-sine) acc. to IEC/EN 60068-2-27 (Ea) 25g / 11 ms Standards / directives Product standard IEC/EN 60947 2 IEC/EN 60947-4-1 IEC/EN 60947-1 UL 508, CS 22.2 No. 14 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC MS110 Manual Motor Starters - 5

Short-circuit breaking capacity and back-up fuses l CS Rated service short-circuit breaking capacity l CU Rated ultimate short-circuit breaking capacity (in case of MS116: = ) I CC Prospective short-circuit current at installation location Note: Maximum rated current of the back-up fuses if I CC > Type 230 V C 400 V C 440 V C 500 V C 690 V C MS116-0.16 MS116-0.25 MS116-0.4 MS116-0.63 No back-up fuse required up to I CC = 30 MS116-1.0 MS116-1.6 No back-up fuse required up to I CC = 50 MS116-2.5 10 10 25 10 10 25 5 5 25 MS116-4.0 6 6 25 6 6 25 2 2 25 MS116-6.3 6 6 63 6 6 63 2 2 40 MS116-10 6 6 63 6 6 63 2 2 50 MS116-12 25 25 80 25 25 80 6 6 63 6 6 63 2 2 50 MS116-16 16 16 80 16 16 80 6 6 63 4 4 63 2 2 63 MS116-20 10 15-10 15-3 6-3 4-2 3 - MS116-25 10 15-10 15-3 6-3 4-2 3 - MS116-32 10 10-10 10-3 6-3 4-2 3-6 - MS110 Manual Motor Starters

Technical data UL/CS Main circuit Maximum operational voltage 600 V Manual Motor Controller ratings see table UL 508 Manual Motor Controller on page 8 Motor ratings Horse power see table below Full load amps (FL) see table below Locked rotor amps (LR) see table below Electrical connection MS116 16 MS116 20 Connecting capacity stranded 1/2 x WG 16... 12 1/2 x WG 12... 8 flexible without ferrule 1/2 x WG 16... 12 1/2 x WG 12... 8 Stripping length 9 mm 10 mm Tightening torque 10... 12 lb-in 18 lb-in Connection screw M3.5 (Pozidrive 2) M4 (Pozidrive 2) Motor rating, single phase hp Horse power; FL Full load amps; LR Locked rotor amps Type 220-240 VC 440-480 VC hp FL LR hp FL LR MS116-0.16-0.16 0.96-0.16 0.96 MS116-0.25-0.25 1.5-0.25 1.5 MS116-0.4-0.4 2.4-0.4 2.4 MS116-0.63-0.63 3.78-0.63 3.78 MS116-1.0-1.0 6.0-1.0 6.0 MS116-1.6 1/10 1.5 - - 1.6 9.6 MS116-2.5 1/6 2.2-1/2 2.5 - MS116-4.0 1/3 3.6-1/2 2.5 - MS116-6.3 1/2 4.9-1 4 - MS116-10 1-1/2 10-2 6 - MS116-12 2 12-3 8.5 - MS116-16 2 12-5 14 - MS116-20 3 17 92 5 14 81 MS116-25 3 17 127 7-1/2 21 116 MS116-32 5 28 162 10 26 145 Motor rating, three phase hp Horse power; Horse power; FL Full load amps; LR Locked rotor amps Type 110-120 VC 220-240 VC 440-480 VC 500-600 VC hp FL LR hp FL LR hp FL LR hp FL LR MS116-0.16-0.16 0.96-0.16 0.96-0.16 0.96-0.16 0.96 MS116-0.25-0.25 1.5-0.25 1.5-0.25 1.5-0.25 1.5 MS116-0.4-0.4 2.4-0.4 2.4-0.4 2.4-0.4 2.4 MS116-0.63-0.63 3.78-0.63 3.78-0.63 3.78-0.63 3.78 MS116-1.0-1.0 6.0-1.0 6.0 1.0 6.0 1/2 0.9 8 MS116-1.6-1.6 9.6-1.6 9.6 3/4 1.6 12.5 3/4 1.3 10 MS116-2.5-2.5 15.0 1/2 2.2 20 1 2.1 15 1-1/2 2.4 16 MS116-4.0-4.0 16.0 1 4.2 30 2 3.4 25 3 3.9 25.6 MS116-6.3 1/2 4.4 40 1-1/2 6.4 40 3 4.8 32 5 6.1 36.8 MS116-10 1 8.4 60 3 9.6 64 5 7.6 46 7-1/2 9 50.8 MS116-12 1-1/2 12 80 3 9.6 64 7-1/2 11 63.5 10 11 64.8 MS116-16 2 13.6 100 5 15.2 92 10 20 81 10 11 64.8 MS116-20 3 19.2 128 5 15.2 92 10 14 81 15 17 93 MS116-25 3 19.2 128 7-1/2 22 127 15 21 116 20 22 116 MS116-32 5 30.4 184 10 28 162 20 27 145 25 27 146 MS110 Manual Motor Starters - 7

UL 508 Manual Motor Controller Type Maximum fuse type Maximum short-circuit current K5 o. RK5 per UL/NEC for motor disconnect 1) for group installation 480 V / 600 V 480 V 600 V 480 V 600 V MS116-0.16 100 30 5 18 5 MS116-0.25 100 30 5 18 5 MS116-0.4 100 30 5 18 5 MS116-0.63 100 30 5 18 5 MS116-1.0 100 30 5 18 5 MS116-1.6 100 30 5 18 5 MS116-2.5 100 30 5 18 5 MS116-4.0 100 18 5 18 5 MS116-6.3 100 18 5 18 5 MS116-10 100 18 5 18 5 MS116-12 100 18 5 18 5 MS116-16 100 18 5 18 5 MS116-20 100 18 5 18 5 MS116-25 100 18 5 18 5 MS116-32 100 18 5 18 5 1SXU131003L0201 June 2011 1) Suitable as motor disconnect only when provided with padlock S1 or S3... BB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-1441 US Technical Support & Customer Service: 888-385-1221, Option 4 7:30M to 5:30PM, CST, Monday - Friday lvps.support@us.abb.com Web: www.abb.us/lowvoltage BB Canada Low Voltage Products 2117, 32 nd venue Lachine, Quebec H8T 3J1 Tel.: 514-420-3100 Toll free: 800-567-0283 Canadian Technical Support: lvp.support@ca.abb.com Web: www.abb.ca/lowvoltage