Indianapolis Power & Light Company



Similar documents
Indianapolis Power & Light Company

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Hyperlinks are Inactive

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Step 1: Application Instructions

COMMERCIAL CONDUIT RULES AND REGULATION

IRRIGATION PUMPING Table of Contents - Section 900

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

CARROLL COUNTY ELECTRICAL DEPARTMENT SERVICE POLICIES. EFFECTIVE MARCH 1, 1995 Revised 1/01/2013

How To Get A Power Line Extension

Electrical Service Guidelines

Please check with your local inspection authority for any additional requirements before installation.

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Policy and Guidelines for Electric Service

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

TABLE OF CONTENTS. PUD SERVICE TERRITORY & CONTACTS... Page 1. NEW SERVICE QUESTIONNAIRE... Page 2. GENERAL... Page 3

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

800 Communications Circuits

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

Electric Service Guide for Residential Construction

Electrical Code Regulation

Electric Service Guide for Commercial Construction

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

MOBILE HOME SERVICE REQUIREMENTS GAS

Underground Service Requirements and Instructions

ADOPTION OF THE NATIONAL ELECTRICAL CODE, 2005

SERVICE - GENERAL Residential, Commercial, Industrial

Electric Service Manual

Approved Meter Sockets and Cabinets

Questions Regarding Proposed Utility Undergrounding in Kensington

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Least Cost Cable System. Strategies to Reduce Cable and Infrastructure Costs When Transitioning to an All Conduit Systems

SERVICE ENTRANCE REQUIREMENTS MANUAL

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

A. Shop Drawing submittals shall include, but not be limited to, the following:

First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Electric Service Guide for Residential Construction

June July 18, of 7

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Call the Experts at REA Energy Services for all of Your Electrical and HVAC Needs.

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

Requirements for the installation of. Electric Services. September 8, Specifications for Electric Installations

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Considering UNDERGROUND. tampaelectric.com

Electric Service Requirements & Guidelines

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Merrimac Municipal Light Department. Residential Developments Policy

Customer Low-Voltage Switchboards Service Cable Terminal Compartment Arrangements and Clearances

Questions and Answers for Heating and A/C Contractors

Report power outage after hours: N E. Ashton, ID ec.com. Ashton, Idaho Headquarters Building

NTUA GUIDELINES FOR DESIGNING AN ELECTRICAL POWER DISTRIBUTION SYSTEM FOR NEW DEVELOPMENTS

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

ELECTRICAL SAFETY Information Bulletin

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

Report on Orange and Rockland Utilities, Inc. s Implementation of the Electric Safety Standards For the 12-Month Period Ending on November 30, 2005

Electric Service Requirement Handbook

Chapter 9. Bonding and Grounding

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ELECTRIC SERVICE HANDBOOK

Electric Service Standards

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

GENERAL ELECTRICAL REQUIREMENTS

SPECIFICATIONS FOR ELECTRIC SERVICE GARLAND POWER & LIGHT

REQUEST FOR ELECTRIC SERVICE Commercial

2. What building projects are exempted? (permit not required)


REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Mobile Home Pre-Inspection Checklist

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Electric Service and Meter Installations Manual SCANA Corporation 2013

MLGW Contact Numbers. Memphis Light, Gas and Water Division P.O. Box 430. Memphis, TN

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Presented by: The Electrical Association of Philadelphia 527 Plymouth Road, Suite 408 Plymouth Meeting, PA (610)

4. REQUEST FOR ELECTRIC SERVICE. 4.1 General Service Information

Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC)

Wellesley Municipal Light Plant. Standard Requirements for Electric Service

Journeyman Class Schedule

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

The Service Entrance. Technical Terms Drip loop Insulator Meter Meter enclosure

SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES

Electric Service Conversion Overhead-to-Underground. Minnesota

Solar Panel Installations

City of Riverside Building & Safety Division Residential Electric Vehicle (EV) Charger Guidelines

ITE/IMSA 2014 Spring Meeting March 6, 2014 Signal Maintenance Practices. Bruce E. Littleton, PE, PTOE Traffic Engineering Supervisor

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Application for. Commercial New Service

Underground Commercial Electric Service

New Residential Service Requiring Construction

SCOPE OF WORK PROVISIONS FOR ELECTRICIAN: MAINTENANCE ELECTRICIAN ORANGE COUNTY

CUSTOMER INSTALLATION STANDARDS FOR ELECTRIC SERVICE

Item Code Full Course Title (Includes Tex t b o o k ) P r i c e. E E 1 F C Basic Electricity and Electronics $

Transcription:

Indianapolis Power & Light Company Electric Service and Meter Manual The Electric Service & Meter Manual is not copyrighted and permission is hereby given to reproduce this document. However, the Indianapolis Power & Light Company takes no responsibility for out of date copies of the Electric Service & Meter Manual that are in use. Written by: W. W. Whitworth, Chairman C. K. Eldridge, Secretary D. E. Fitzwater R. J. Gray C. E. Johnson M. J. Kuehn M. Love D. D. Lufcy R. R. Manion K. L. Walker T. J. Wroblewski Revised 6/10/14

ELECTRICAL INSPECTION AUTHORITIES COVERING TERRITORY SERVED BY INDIANAPOLIS POWER & LIGHT COMPANY City of Indianapolis (Marion County) Kate Warpool Scott Mason Christopher Freeman (Electrical Chief) Automated Inspection Request Line Beech Grove Mike Fitzgerald Boone County John Hudson Jerry Seymour Department of Code Enforcement City of Indianapolis 1200 Madison Ave. Suite 100 Indianapolis, IN 46225 http://www.indy.gov/dce Administrator, Construction Services Manager, Building Inspections Supervisor, Building Inspections Electrical Inspector City Hall 806 Main Street Beech Grove, IN 46107 Electrical Inspector 116 W. Washington St., Rm. 101 Lebanon, IN 46052 8 AM 9 AM & 3 PM 4 PM Mon. thru Fri. General Information Ph: 327-8700 Ph: 327-5553 Ph: 327-5550 Ph: 327-5554 Ph: 327-5525 Ph: 223-4776 Ph: (765) 482-3821 Fax: (765) 483-5241 City of Cumberland (Hancock Co.) Scott Stephens Ph: 894-6202 894-6213 Fax 894-6216 Greenwood Tony Magnabosco Lowell Weber Electrical Inspector 225 S. Emerson Avenue Greenwood, IN 46143 Ph: 881-8698 Hamilton County (Carmel and Clay Townships Only) Building & Electrical Inspectors 1 Civic Square Carmel, IN 46032 Ph: 571-2444 If a correction is needed, please send an e-mail with the correction to charlie.eldridge@aes.com to have it corrected v Revised 6/10/14

200A Meter Fitting Installed After Main Service Equipment Network Installation Only 277/480 Volt, 1 Phase, 3 Wire 125A Maximum Service 200A Meter Fitting 225A Maximum Service 200A Meter Fitting, 2, 3 or 4 Gang 225A Maximum Service Per Position 320A Meter Fitting 250A to 400A Service Residential Outdoor Metering (Single Family Dwelling Only) 450A to 800A Service Commercial Outdoor Metering 450A to 800A Service Residential Outdoor Metering (Single Family Dwelling Only) 850A to 1600A Service 200A Single Phase Residential Services 125A Single Phase Commercial Services 120/208 Volt, 1 Phase, 3 Wire 200A Maximum Service 200A Meter Fitting (Installed After Main Service Equipment) 120/208 Volt, 1 Phase, 3 Wire 200A Maximum Service 100A & 200A Meter Center 225A Maximum Service Per Position 120/208 Volt, 1 Phase, 3 Wire 200A Maximum Per Position Residential 100A Maximum Per Position Commercial GB1-075 GB1-080 GB1-090 GB1-100 GB1-110 GB1-120 GB1-121 GB1-130 GB1-140 GB1-150 -IV- Revised 6/10/14

Distributed Generation Contact Information Level I Applications Jake Allen, Marketing and Program Management, 261-8972 John Haselden, Regulatory Affairs, 261-6629 Level II and III Applications Account Management Executives shown on drawing GB0-120 Technical Mark Kempker, Planning, 261-8615 Ron Cooper, Planning, 261-8076 Regulatory Ken Flora, Regulatory Affairs, 261-6713 NOTE: EMAIL ADDRESS FORMAT IS firstname.lastname@aes.com REV 6/10/14 DISTRIBUTED GENERATION GB0-115

Monsanto Love 261-8672 Section Leader Commercial and Residential Covers the entire Company service territory for the Service Connection crews William Maines 261-8731 Residential Only Covers the entire Company service territory for conversion from an overhead service drop to an underground service lateral, new service installations and service lateral relocations NOTE: EMAIL ADDRESS FORMAT IS firstname.lastname@aes.com RESIDENTIAL SERVICE INSTALLATIONS AND SMALL COMMERCIAL (NON-CT METERED) REV 6/10/14 INSTALLATIONS GB0-160

Section 560, cont. F. Customer shall furnish and install posts to protect meter cabinets, junction boxes, conduits, and other facilities as specified by the Company when exposed to vehicular traffic. Each post shall be a minimum of 7'-0" long and 6 inch diameter steel pipe. The posts shall be concrete filled, set in concrete and extend 4'-0" above grade. Contact the Company for approval of post arrangement. G. For the installation of Company cables: 1. All nonmetallic conduit installed above grade shall be gray schedule 80 or heavier. 2. Where conduit is installed from a meter fitting or enclosure into the earth, the conduit shall extend a minimum of 18" below grade and have a box adapter at the point of termination of the conduit in order to provide a smooth edge. This requirement does not apply to continuous conduit turned up for riser poles or into pad mounted transformers. 3. All metallic conduit shall be rigid or IMC. 4. Where conduit is in contact with the earth, the conduit shall not be aluminum. 5. All conduit elbows for the installation of the Company's cable shall be 4" X 36" radius minimum. 6. All conduit runs shall be installed with a with a pull string. H. The electrician shall take precautions when adding any circuits to an existing installation to insure that it is connected on the load side of the meter. Only one conductor may be connected to each terminal of an individual meter position in any self-contained meter fitting. Terminals for more than one conductor and terminals used to connect aluminum shall be so identified. I. On a three phase, four wire, delta service, the phase conductor having the higher voltage to ground shall be permanently marked at each point of connection, in accordance with the Indiana Electrical Code. If red or orange is used to mark the phase having the higher voltage to ground, red or orange shall not be used to mark any other phases. J. The contractor shall install the meter fittings and meter cabinets provided by the Company. If service junction boxes are required, they shall be provided by the Company and installed by the contractor as specified by the Engineering Department. K. The Company will make all connections in the service junction box. The contractor shall identify all cables by meter position. If no junction box is required, the Company will make connections on the line side of the meter or current transformers. 36 Revised 6/10/14