AVIATION WARNING LIGHT WITH LED PRODUCT CODE: OPT-04



Similar documents
AVIATION WARNING LIGHT WITH LED PRODUCT CODE : OPT-01

ISO 9001 : 2000 certified Copyright 2008 All rights are reserved

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Fire Pump Controllers Remote Alarm Panels

Floodlight Range Installation Guide

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

INDICATOR LAMPS & LED REPLACEMENT LAMPS

HERZ-Thermal Actuators

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Cross-beam scanning system to detect slim objects. 100 mm in

Water Leak Detection System

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Cisco Unified IP Phone Power Injector

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Product and functional description

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

2013 Wireless Video Intercom INSTALLATION GUIDE

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DuroSite TM High Bay Lighting

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electronic, Digital and Mechanical Vibration Switches

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Superlight Compact Nano

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

PRO 5000 CPE 1D Quick Installation Guide

D/N VARI-FOCAL IR CAMERA

Uninterruptible Power Supply

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

Guideline Laser Series

SURGE PROTECTIVE DEVICES

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

DALI RC BASIC SO. Control unit Operating instructions

AIRCRAFT ARRESTING BARRIER Stanchion System with TEXTILE BRAKE AT-AB/1S TEK - TB10-150

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

Energy Saving ECM Motors and Fans Ventilation Catalogue

ACS-30-EU-EMDR-10-MOD

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

COLOR VIDEO DOOR PHONE CDV-71BE/D

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

WD-AMX Water Detection Controllers

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

FIRERAY 2000 Installation Guide

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

SUPER SLIM LINEAR LED LIGHT

Product Specification instalert Rapid Messenger Variable Message Sign

FLOOR INDICATORS CATALOGUE 2007

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

OBSTRUCTION LIGHT OL 150-LED 230V

IP66 PROTECTION ULISSE RADICAL 33X

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Airfield Lighting Product Description F2.1 F22. Low Intensity Obstruction Light

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

1. INTRODUCTION FEATURES 2. PROGRAMMING

Multifunction devices

Emergency lighting units EM powerled

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

LED Anti-Collision Lighting System for Airbus A320 Family

Electric Rotary Actuator - On/Off or programmable control actuator

Installation and Operation Guide PD4600 Series Converter Replacement

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

RY2 miniature industrial relays

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Medical Lighting. XL4 Patient Light

Product specifications

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Operating Instructions

TOKISTAR. Cable Lighting TOKISTAR LIGHTING

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

19" 5:4, Flicker Free IPS LED Monitor with VGA and DVI VA951S

I STAR COMPUTER CO., LTD

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

MAJORSINE Power Inverter

Moving Head - One Signal Cable - One Omega Clamp One Power Cable - One Safety

Linear Luminaire with LED Series EXLUX 6402/2

INSTALLATION MANUAL. AC/DC Power Supply

Transcription:

AVIATION WARNING LIGHT WITH LED PRODUCT CODE: OPT-04 OPT-04 User Manual Page 1

Table of Contents 1. GENERAL SPECIFICATIONS... 3 1.1 Supply Voltage...... 3 1.2 Lamp Type... 3 1.3 Failure Warning System... 3 1.4 Blink System...3 1.5 Continuous System... 3 1.6 Operating Temprature... 3 1.7 Operating Frequency... 3 1.8 Cable Specification... 3 1.9 Connection Diagram... 4 1.10 Order Information...5 1.11 Certifateces.....5 2. TECHNICAL SPECIFICATIONS...6 3. PRODUCING FIRM...7 Page 2

1.GENERAL SPECIFICATIONS : OPTİMA Warning Lights, are designed and manufactured to warn aircrafts / helicopters for high altitude places. It is designed to use on high towers, monopole masts, high buildings, flagpoles and all warning related areas. System consists of one unit single lamp armature. System operates under the control of microprocessor and photocell so automatically turns the system on when ambience gets dark and turns it off when the ambience gets lighten. Upon request in ordering process, system options below are available. 1.1 Supply Voltage : 12V AC/DC - 24V AC/DC - 48VAC/DC - 110V AC/DC - 220V AC 1.2 Lamp Type : Led Lamp: OPTİMA Lamps are specially designed and manufactured by OPTİMA ELEKTRONIC. Due to lamps completely made by leds, they have very long working lifes. (100.000 hours). OPTİMA Aviation Warning Lights has 5 years warranty. 1.3 Failure Warning System (Alarm System) : With this option, user is able to control the operation of system from a distant place. User installs the system by connecting failure outputs (COM: common NO: normally open NC: normally close) to sounded or lighted warning device. In case of any failure, lamps send warning to failure warning unit inside the control box. By means of Failure Warning System, problem is solved in a short time. 1.4 Blink System: Lamps blinks 60 times in a minute. 1.5 Continuous System : On this option system works continuously. 1.6 Operating Temprature : -55 C / +55 C 1.7 Operating Frequency : 50 Hz 1.8 Cable Specifications *4x1,5 NYY and LIYCY cable types are recommended for models with alarm function 2x1,5 NYY and LIYCY cable types are recommended for models without alarm function. Nevertheless the cable types could be determined as per customer request. *Cable lenght must be calculated due to tower lenght and distance between power supply and control center. Page 3

1.9 Connection Diagram Figure-1 Figure-2 Figure-3 Figure-4 Page 4

1.10 Order Informatıon : a- Supply Voltage b- Continuous or Blink System 1.11 Certifacetes : - CE Certifacete Custom Designs Special designs can be made in line with customer demand. Please contact with OPTİMA. FUNCTIONALITY TEST OF THE SYSTEM: First tests should be conducted before the system mount on the tower. Test steps; 1-Check the physical conditions of the system. Be sure that system is not damaged. 2-Read the user manual in the package completely. Page 5

2. TECHNICAL SPECIFICATIONS OPTİMA AVIATION WARNING LIGHT TECHNICAL PROPERTIES TEKNİK ÖZELLİKLER: LED Number Total Candela Visibility Distance Visibility Angle Energy Spending Operating Time LED Test Alarm Output Maintanence LED Life 140 units Ultra Bright Led 810.000 mcd 10 km in dark and clear environment conditions (Annex14 standard) X Plane=360 (horizontal) Y Plane= 45 (vertical) (Annex14 standard) 6~7 Watt/hour Operates according to the lighting level, does not considers temporary lightning. Exists (Uninterrupted test at night, Once in 10 minutes at daytime) With dry contact output. Normally Open or Normally Closed No need to maintanence 100.000 hours (operating duration) Operating Temprature -55 C +55 C Light Store Bottom Body Operating Voltage IP Standard Mode of operation Body Paint Bolts-Nuts-Washers Weight Dimensions Fastening Bracket Polycarbonate (Red) warm, forst and ignition-resistant Aluminium Casting 12V AC/DC, 24V AC/DC, 48V AC/DC,110V AC, 220V-AC IP65 Lamps blinks 60 times in a minute Ral-7032 Elektrostatik Polyester Coated 965 Gr Figure-4 865 Gr Page 6

3. PRODUCING FIRM As a result of R&D studies, OPTİMA aviation warning light led lamp has been developed by OPTİMA ELECTRONIC COMPANY in 2006. OPTİMA ELEKTRİK ELEKTRONİK VE TELEKOMÜNİKASYON SANAYİ TİCARET LİMİTED ŞİRKETİ OPTİMA ELECTRIC ELECTRONIC AND TELECOMMUNICATION INDUSTRY COMMERCE LIMITED CORPORATION Dudullu Organize Sanayi Bölgesi 3. Cad. Saraçoğlu İş Merkezi No:5/37-38 ÜMRANIYE / İSTANBUL / TURKEY PHONE: +90 216 364 09 20 FAX: +90 216 364 09 21 E-MAIL: info@optimaelektronik.com.tr WEB: www.optimaelektronik.com.tr Page 7