AVIATION WARNING LIGHT WITH LED PRODUCT CODE : OPT-01
|
|
- Marshall Lloyd
- 8 years ago
- Views:
Transcription
1 AVIATION WARNING LIGHT WITH LED PRODUCT CODE : OPT-01 OPT-01 User Manual Page 1
2 Table of Contents GENERAL SPECIFICATIONS Supply Voltage Lamp Type Backup System Simultaneous System Failure Warnings System Blink System Continuous System Operating Temprature Operationg Frequency Cable Specifications Certifacetes Mechanical Specifications Connection Diagram.. 6 TECHINICAL SPECIFICATIONS... 7 PRODUCING FIRM Page 2
3 GENERAL SPECIFICATIONS OPTİMA Warning Lights, are designed and manufactured to warn aircrafts / helicopters for high altitude places. It is designed to use on high towers, monopole masts, high buildings, flagpoles and all warning related areas. OPT-01 System consists of one unit double lamp armature. System operates under the control of photocell relay so automatically turns the system on when ambience gets dark and turns it off when the ambience gets lighten. Upon request in ordering process, system options below are available. 1- Supply Voltage: 12V AC/DC - 24V AC/DC - 48VAC/DC - 110V AC/DC - 220V AC 2- Lamp Type : OPTİMA Led Lamp Optima Led Lamp : OPTİMA Lamps are specially designed and manufactured by OPTİMA ELEKTRONİK. Due to lamps completely made by leds, they have very long working lifes. ( hours). OPTİMA Aviation Warning Lights has 5 years warranty. 3- Backup Systems : System has two lamps on two seperate arms. While one of the lamps is working the other lamp waits as a spare.(figure-1) If active lamp fails, it sends a failure code to the spare one and turn the spare one on after 3 seconds. Figure-1 4- Simultaneous System : Two lamps on two arms works simultaneously.(figure-2) If one of the lamps fails it does not effect the other lamp. Figure-2 Page 3
4 5- Failure Warning System : With this option, user is able to control the operation of system from a distant place. User installs the system by connecting failure outputs (COM: common NO: normally open NC: normally close) to sounded or lighted warning device. In case of any failure, lamps send warning to failure warning unit inside the control box. By means of Failure Warning System, problem is solved in a short time. 6- Blink System : Lamps blinks 60 times in a minute. 7- Continuous System : On this option system works continuously without blinking. 8- Operating Temprature : -55 C / +55 C 9- Operationg Frequency : 50 Hz 10- Cable Specifications : a- System with Error Alert : 4x1.5mm2 b- System without Error Alert : 2x1.5mm2 *NYY and LIYCY cable types are recommended, the cable types are determined due to customer choice. *Cable lengths must be calculated due to tower length and distance between power supply and control center. 11- Certifacetes: CE Certifacete FUNCTIONALITY TEST OF THE SYSTEM: First tests should be conducted before the system mount on the tower. Test steps; 1-Check the physical conditions of the system. Be sure that system is not damaged. 2-Read the user manual in the package completely. Page 4
5 12- Mechanical Specifications : ARMATURE: 1-Armature Body : Aluminium Moulding 2-Armature Cover : Aluminium 3-Body Paint : Ral-7032 Elektrostatic Polyester 4-Bolts-Nuts-Washers : Coated 5-Lamp Protective Cover : Red Polycarbonate 6-Protection Class : IP-65 7-Dimensions : 365mmx500mmx110mm (Figure-3) 8-Weight : 2.8 kg Figure-3 Page 5
6 13- Connection Diagram Figure-4 Figure-5 Figure-6 Page 6
7 TECHNICAL SPECIFICATIONS OPTİMA AVIATION WARNING LIGHT TECHNICAL PROPERTIES TEKNİK ÖZELLİKLER: LED Number Total Candela Visibility Distance Visibility Angle Energy Spending Operating Time LED Test Alarm Output Maintanence LED Life 140 units Ultra Bright Led mcd 10 km in dark and clear environment conditions (Annex14 standard) X Plane=360 (horizontal) Y Plane= 45 (vertical) (Annex14 standard) 6~7 Watt/hour Operates according to the lighting level, does not considers temporary lightning. For double armature; 2nd light operates when the 1st one breaks down Exists (Uninterrupted test at night, Once in 10 minutes at daytime) With dry contact output. Normally Open or Normally Closed No need to maintanence hours (operating duration) Operating Temprature -55 C +55 C Light Store Bottom Body Operating Voltage IP Standard Mode of operation Body Paint Bolts-Nuts-Washers Weight Dimensions Fastening Bracket Polycarbonate (red)- Resistant to warming. İcing and ignition Aluminium Casting 12V AC/DC, 24V AC/DC, 48V AC/DC,110V AC, 220V-AC IP65 Lamps blinks 60 times in a minute Ral-7032 Elektrostatik Polyester Coated 2.8 Kg Figure Gr Page 7
8 PRODUCING FIRM As a result of R&D studies, OPTİMA aviation warning light led lamp has been developed by OPTİMA ELECTRONIC COMPANY in OPTİMA ELEKTRİK ELEKTRONİK VE TELEKOMÜNİKASYON SANAYİ TİCARET LİMİTED ŞİRKETİ OPTİMA ELECTRIC ELECTRONIC AND TELECOMMUNICATION INDUSTRY COMMERCE LIMITED CORPORATION Dudullu Organize Sanayi Bölgesi 3. Cad. Saraçoğlu İş Merkezi No:5/37-38 ÜMRANIYE / İSTANBUL / TURKEY PHONE: FAX: info@optimaelektronik.com.tr WEB: Custom Designs Special designs can be made in line with customer demand. Please contact with OPTİMA. Page 8
AVIATION WARNING LIGHT WITH LED PRODUCT CODE: OPT-04
AVIATION WARNING LIGHT WITH LED PRODUCT CODE: OPT-04 OPT-04 User Manual Page 1 Table of Contents 1. GENERAL SPECIFICATIONS... 3 1.1 Supply Voltage...... 3 1.2 Lamp Type... 3 1.3 Failure Warning System...
More informationFire Pump Controllers Remote Alarm Panels
Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel
More informationISO 9001 : 2000 certified Copyright 2008 All rights are reserved
LED STREET FLOOD LIIGHT Teksav Teknoloji Elektrik Elektronik Makine Sanayi ve Tic A.S. 10016 Sokak No: 20 A.O.S.B. Cigli Izmir Turkey Tel : +90-232- 328 1141 (PBX) Fax : +90-232- 328 1147 Doc no : 081027-1
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationCisco Unified IP Phone Power Injector
Data Sheet Cisco Unified IP Phone Power Injector The Cisco Unified IP Phone Power Injector (Figure 1) increases the deployment flexibility of Cisco Unified IP phones by providing an alternative powering
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationWespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE
Wespot SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE EN This manual is published by OPTEX, without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies
More informationXUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm
Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION
ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION 2014 Ferport/Armas has over 30 years been synonymous with technology, reliability and experience in
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationPSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
More informationSD Series. SD Series Rectifiers. EPC Energy & Power Conversion
Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and
More informationDALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
More informationPOINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES
INCANDESCENT Compliances: ETL Listed to UL 1598 USA ETL Listed to CSA C22.2 No. 250.0-04 Canada ETL Certified FAA L-810 per FAA AC 150/5343G ICAO Annex 14 Low Intensity Types A (10 cd) & B (32 cd) IMO
More informationWater Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
More informationPOINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION
Compliances: Class I, Division 2, Groups A B C D, T5 at -40 deg C to +55 deg C* Class I, Zone 2, Groups IIA IIB+H2 IIC, T5 at -40 deg C to +55 deg C* Certified FAA L-810 by Intertek Testing Service (ETL)
More informationABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationINDICATOR LAMPS & LED REPLACEMENT LAMPS
INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE
Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly
More informationDuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
More informationElectronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationShort Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
More informationWATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationProduct Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
More informationSPID Azimuth Antenna rotator Type: BIG-RAK/HR
WWW.RFHAMDESIGN.COM SPID Azimuth Antenna rotator Type: BIG-RAK/HR SPID BIG-RAK/HR MD-02 Rotor Controller Type BIG-RAK/HR is a 1 engine rotor system (Azimuth) and delivered including: BIG-RAK/HR rotor 0.2
More informationOBSTRUCTION LIGHT OL 150-LED 230V
OBSTRUCTION LIGHT : OL150-LED 230V OBSTRUCTION LIGHT OL 150-LED 230V Type OL 150-LED 230V Illuminating power 10 cd minimum (14 cd typical) Light source Obelux 230-E27 LED Life time 100 000 hours Cable
More informationCOLOR VIDEO DOOR PHONE CDV-71BE/D
COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed
More informationLED Anti-Collision Lighting System for Airbus A320 Family
LED Anti-Collision Lighting System for Airbus A320 Family LEDs established in anti-collision lighting For the first time, UTC Aerospace Systems has implemented state-ofthe-art LED technology into an anti-collision
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
3 3000 6000 W Electrical heat 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationD/N VARI-FOCAL IR CAMERA
D/N VARI-FOCAL IR CAMERA PIH-0364X/0368X/0384X/0388X W/S INSTRUCTION MANUAL IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before the unit is operated.
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationFTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This
More informationASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)
ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A) ATEL TEKNOLOJİ ve SAVUNMA SANAYİ A.Ş. ATEL TECHNOLOGIE and DEFENSE INDUSTRY Inc. Co. Hilal Mah. 677. Cad. No: 9 06550 Çankaya ANKARA / TÜRKİYE
More informationSuperlight Compact Nano
Willy Meyer+Sohn GmbH+Co. KG Stemmessiepener Weg 5 D-58675 Hemer Telephone: +49 (0) 23 72/98 91-0 Telefax: +49 (0) 23 72/98 91-48 E-mail: info@meyer-lighting.com www.meyer-lighting.com 258 00 530-1211
More informationT1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More informationBusiness/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
More informationPC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationHigh Resolution Media Display - B series 20mm Pitch Outdoor RGB Module
Date: Quantity: Company: Project: 1 High Resolution Media Display - B series The High Resolution Media System displays crisp, clear imaging in vivid color and detail. This Outdoor RGB Module provides scalable
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationNELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence
More informationWD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
More information(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationPolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More information2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
More informationInstallation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
More informationINSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C 20094 Corsico (MI) phone +39-02 - 48601011 / 4581861 Fax: +39-02 48600783
INSTRUCTION MANUAL VRT-200 TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C 20094 Corsico (MI) phone +39-02 - 48601011 / 4581861 Fax: +39-02 48600783 http://www.tecsystem.it R.3 27/03/03 VRT200 protection
More informationLC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
More informationSecurity. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationHome Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationKnow-how makes the difference. Electrical Actuators
Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product
More informationEvolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASB) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationDehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationLong sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
More informationUninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationOLI. Oil level indicator
OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes
SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted
More informationWater Leak Detector BA/LDT Accessories Termination and Troubleshooting
Overview & Identification The is designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. Upon water detection, an alarm relay changes state,
More informationLEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34
LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR
More informationSolid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection
More informationOperating Instructions
CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More information1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.
DIGITAL AUDIO INTERCOM SYSTEM The contractor shall Supply, Install, Test and Commission a modern Audio Entry Phone System to facilitate Audio Communication between the different apartments and the building
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationGTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
More informationCardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationEvolve LED Area Light
GE Lighting Evolve LED Area Light Scalable Area Light (EASA) imagination at work Product Features The next evolution of the GE Evolve LED Area Light continues to deliver outstanding features, while adding
More informationTS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationAirfield Lighting Product Description F2.1 F22. Low Intensity Obstruction Light
F2.1 F22 Low Intensity Obstruction Light Note: This page is blank for convenient double-sided printing. 1. INTRODUCTION Obstruction lighting is intended to reduce the hazards to aircraft by indicating
More informationINSTALLATION MANUAL. SAILOR 5080 AC Power Supply
INSTALLATION MANUAL SAILOR 5080 AC Power Supply Contents Introduction... 3 General description... 3 Technical data... 3 Installation... 4 Outline and dimension... 4 Installation wiring... 5 Block diagram
More informationTechnote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationLow Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs
Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs Part #: GAU-LB-400 Page: 1 Made in USA Compliant The GAU-LB-400 LED Low Bay Light offers high light output from a compact
More informationAC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
More informationMedical Lighting. XL4 Patient Light
Medical Lighting XL4 Patient Light The XL4 is the new ergonomically designed, energy efficient patient light from EDL Lighting Limited. Its purpose is to cover a spectrum of applications within the Healthcare
More informationOutput torques up to 8000 Nm. General features. Protection. External coating. Working temperature range
Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:
More informationProduct Guide Specification
Americas Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: + 1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East,
More informationElectronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W
T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a