SD Series. SD Series Rectifiers. EPC Energy & Power Conversion



Similar documents
Thyristor-controlled power supplies and battery chargers

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

MAJORSINE Power Inverter

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Phase Modular Finally the benefits of Modular ups are for all

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Uninterruptible Power Supply

User s Manual Before using the inverter, you need to read and save the safety instructions.

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

SMART SENSOR COLLECTION

DCS Series 1 kw, 1.2 kw, & 3 kw

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

7-41 POWER FACTOR CORRECTION

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

MPR-Systems. Mini Power Racks 1200 W W

4.0 UPS dedicated to ICT for unmatched energy savings

Operating Manual UWAPS-TINY Series

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Research RF Sputtering Packages

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Specification Requirements DBL 700MX and 1000MX Series UPS

I STAR COMPUTER CO., LTD

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

User Manual 1K/2K/3K Online UPS

PowerGem Pro Uninterruptible Power Supply

HIGH FREQUENCY RECTIFIERS 24 & 48 VDC

Diesel Generating Set

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

TOSHIBA G /100/160/225 kva

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

BB800 Off-Grid Solar System

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

OUTPUT CABLE CONNECTIONS:

Stroom voor elke toepassing

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

10000HXL31/15000HXL31/20000HXL31

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

SURGE PROTECTIVE DEVICES

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

High Efficiency Battery Charger using Power Components [1]

Installation manual. Generator Paralleling Controller GPC multi-line C

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

IntesisBox KNX LG Air Conditioning

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ELECTRONIC POWER SYSTEMS

Infinity C DC to DC Power System

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Online UPS. PowerWalker VFI 1000R/1U

650W Single Output Power Supply

What is a multimeter?

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Intersection Preassembled 19-inch Rack

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

DC/DC power modules basics

Assembled in Florida, USA.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

LM2704 Micropower Step-up DC/DC Converter with 550mA Peak Current Limit

Low Voltage Products

UPS Applications and VRLA Battery Sizing

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Properties of electrical signals

Technical data UNIBLOCK UBSF

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Inverter / Charger Installation General Operations and AC and DC Connections

Model #: SMART2200CRMXL

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

SWITCHGEAR. EGP Switchgear

Charger Output AC Ripple Voltage and the affect on VRLA batteries

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

SKY LIGHT INTERSECTION SYSTEM

Series AMLDL-Z Up to 1000mA LED Driver

Transcription:

Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and extended battery life High efficiency and low operation cost Wide range of options for monitoring Improvedenviromental operation characteristics Remote monitoring via RS232 communication port Potential free alarm contacts on extended alarm board Tel : 90 216 622 30 73 (pbx) Fax : 90 216 622 30 79

Rectifiers rectifiers provide pure and regulated DC power for load, charging of LeadAcid and NicelCadmium batteries. SD series rectifers are used for very wide range of DC power applications such as power plants, telecommunication, power generation and distribution, traction, emergency lighting, automation systems and petrochemical plants. Rectifiers are equipped withthyristors, which are used in Semiconductor Controller Rectifier technology. Phase control and regulation are made by microprocessor controled eletronic boards. SD series has also output voltage regulation features with automatic current limiting. rectifiers are flexible for different applications. Optional N1 paralleling redundancy can be obtained by paralleling diodes. By adding optional load circuit and current limiting unit, rectifier can be used as DC UPS, which provides DC power to load from battery, when the AC input is not available. Whenthe AC input is recovered, rectifier will feed your DC load and charge your batteries. A load circuit for this purpose can be build by diode drop blocks or by a DC/DC converter, depending on requirements of the customer. Tel : 90 216 622 30 73 (pbx) Fax : 90 216 622 30 79

Standart and Optional Features STANDART OPTIONAL 1 2 High Voltage Absorber (MOV) 3 RFI Filter INPUT 4 5 HarmonicFilter Inductor Neutral Connection 6a Used Neutral Connection 6b Unused Neutral Connection 7 GalvanicIsolated Input Transformer 8 Regulated & Full Controlled SCR DC Regulation Units RECTIFIER 9 DC Inductor 10 DC Capacitor Control Boards 11 Main Logic Board Battery Circuit 12 Parallelling Block 13 Load Circuit OUTPUT 14a Voltage & Current Limiting Block 14b Diod Voltage Drop Block 14c Voltmeter 14d Ampermeter 14e Measurements STATUS MONITORING & CONTROL 15 15a 15b 16 17 17a 17b 18 18a 18b 19 20 21 Rectifier Output (Battery) Voltage & Current Analog Voltmeter & Ampermeter AC Input Voltameter (Only Analog 72x72 ) User Interfaces LCD Panel Paremeter Adjustments, Monitoring & Alarms Simple Control & Display Panel LCD Panel Alarm Terminals (Fuse Protected Dry Contacts) Common Alarm (NC,C,NO) Customized Alarm (NC, C, NO) RS232 Communication Additional Control & Monitoring Options Input Circuit Breaker Battery Circuit Breker Status Tel : 90 216 622 30 73 (pbx) Fax : 90 216 622 30 79

Rectifiers Technical Specifications INPUT Voltage Frequency Power Factor Circuit Protection 380Vac / 400Vac / 420Vac / 10% 15% 3PN 4W (3P 3W Optional) 50Hz / 60Hz Selectable 5% < 0,8 MCB or MCCB High Voltage Protection (Metal Oxide Varistor) OUTPUT Voltage Current Current Limiting & Trip Circuit Protection 24Vdc / 48Vdc / 110Vdc / 220Vdc Nominal 15Adc / 30Adc / 60Adc / 100Adc / 150Adc / 200Adc / 300Adc Nominal Current Limiting adjustable between 10% to 115% Current Trip adjustable between 10% to250% Termic Magnetic Circuit Breaker (Ic > 16 ka) 24 VDC > 80% Efficiency (at full load) 48 VDC > 80% 110 VDC > 90% 220 VDC > 90% Voltage Ripple Voltage Regulation < 1% (with or without battery) (<0,5 % optional) < 1% (10% to 100% load) Charger Mode Charge Type Float Charge Voltage Range Boost Charge Voltage Range Protection Class Cooling Color Cable Inlet Mounting Operation Temperature Storage Temperature Relative Humidity Operation Altitude CHARGE CHARACTERISTICS GENERAL ENVIROMENTAL CHARACTERISTICS Automatic / ManualUICharacteristic Float / Boost (Manual equalizing charge optional) 90% 115% adjustable 90% 115% adjustable IP20 (Higher IP Class Optional) Forced cooling with termic controlled fan RAL 7032 (Other colors optional) Bottom (Top inlet optional) Floor 5 ºC to50 ºC 40 ºC to 50ºC 090% Non condensing 0 1000 m Tel : 90 216 622 30 73 (pbx) Fax : 90 216 622 30 79

Rectifiers STATUS MONITORING (Simple Panel or LCD Panel, Leds) Output Voltage (Analog 72x72 or LCD Panel) Output Current ( Analog 72x72 or LCD Panel) Charge Mode Charge Type AC OK Sign Operation Status Log Record / Alarm History (Only with LCD Optional) RS232 Communication Input Voltage (Optional Only Analog 72x72) Load Voltage (Optional withload circuit, only analog 72x72) Load Current (Optional with load circuit, only analog 72x72) Breaker Status (Optional) Common Alarm CONTROL (Simple Panel or LCD Panel) Eletronic Control, Start & Stop Output Voltage Adjustment Charge ModeAdjustment Charge TypeAdjustment Automatic Recovery After Alarm Date & Time (Only withlcd Optional) Time Controlled Boost Charge, adjustable up to72 hours Periodical Boost Charge (Only with LCD Optional) Language Selection (Only with LCD Optional) DC Undervoltage & Overvoltage Protection Availibility Matrix Weigth (kg) 24 V 48 V 110 V 220 V 24V 48V 110V 220V 15A 30A 60A 100A 150A 200A 300A Dimensions 500 / 450 / 1000 600 / 600 / 1300 750 / 700 / 1600 800 / 800 / 1600 15A 30A 60A 100A 150A 200A 300A 110 180 230 280 110 185 230 260 270 150 300 485 500 190 295 490 Tel : 90 216 622 30 73 (pbx) Fax : 90 216 622 30 79