VENTURI TUBE METER. Description

Similar documents
Daniel Venturi Tubes and Flow Nozzles Brochure

The Unique Accelabar Flow Meter

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Using meters to measure steam flow

Flow Measurement Options for Pipeline and Open Channel Flow

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Air Eliminators and Combination Air Eliminators Strainers

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

Custody Transfer Measurement. with the V-Cone Flowmeter

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

BLADDER SURGE CONTROL SYSTEM

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

CERTIFIED. Ellipse. The. Flow Sensor. Your First Choice in Intelligent Flow Management...

PRESSURE REDUCING CONTROL VALVE

Laminar Flow Elements

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

V-Cone, An Alternative to Orifice Meter in Wet Gas Applications

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

T U R B I N E G A S M E T E R

REGULATORS 175/153 Series

FLUID FLOW Introduction General Description

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE

C. starting positive displacement pumps with the discharge valve closed.

In-Line Electronic Flow Switches

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Pipe Cutting and Beveling Clamshells

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Pressure and Temperature Controls

VAD. Variable Area Desuperheaters

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

GS-General Service Control Valves

OPTIMASS 1400 Technical Datasheet

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Morrison Bros. Co. General Product Specifications

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

For Multi-Parameter Meters see mvx

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

REGULATORS D& HD Series

ASME Packaged Indirect Fired Water Heater

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

V47 Series Temperature Actuated Modulating Water Valves

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Water Jet Eductors. Construction. Introduction

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Interface Level And Point Level Analyzers & Sensors

VERTICAL TURBINE AND PROPELLER PUMPS

Triple Service Valve Assembly

SJT / SJM / SJP Large Vertical Pumps

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

In-Line Electronic Flow Switches

OPTIMASS 6000 Technical Datasheet

FLASH TANK ECONOMIZER PRODUCT GUIDE

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Copper and Copper Alloy Tube, Pipe and Fittings

Copper Meter Resetters

Series 4000 Fiberglass Pipe and Fittings

SECTION DUCTILE IRON PIPE AND FITTINGS

NDP-50 Specifications

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

Electronic Flow Switches

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Baumann Way Bronze or Stainless Steel Control Valve

TYPE E Main Valve Sizes 3 /8 through 12

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

1805 Series Relief Valves

TABLE OF CONTENT

08.08 Vic-Check Valves

Baumann Flexsleev Sanitary Control Valve

Comparison of multiple port and end port connections for pressure vessels

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

Typical Aluminum GFM Mass Flow Meter

Types 66R and 66RR Low-Pressure Relief Valves

Rosemount Orifice Plate in Wet Gas

Flygt Ball Check Valves

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Hose Clamps & Fittings

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Transcription:

VENTURI TUBE METER Description The DECON Venturi Tube is a differential-producing primary flow element that accurately and repeatable measures the flows of liquids or gases in closed and full pipe use conditions. The venture tube incorporates an efficient hydraulic shape with static pressure taps in the throat and inlet sections, the venture tube can be provided with pressure rating 5 to 2500 PSI, BW or flange connections. Application The cast iron series is often used in municipal water and waste water applications. Known for longevity of service with minimal maintenance, DECON fabricated venturi are ideal for metering potable water, sludge, slurries, as well as gases and clean fluids, steam, chemic or petrochemical products.. Flow Measurement Accuracy For pipe Reynolds numbers greater than 75 000 and with a normalized piping configuration, the DECON Venturi Tube provides a flow measurement accuracy of ± 0.50% without flow calibration. With independent flow calibration, DECON provide the user with ± 0.25% accuracy. Accuracy For pipe Reynolds numbers greater than 75 000 and a normalized piping configuration, the DECON Venturi Tube provides a flow measurement uncertainty of: ± 0.50% for standard meters and ± 0.25% for flow calibrated meters. Pressure Loss The permanent pressure loss of the DECON Venturi Tube is shown in Figure 1. Technical Specifications Temperature Range Cast iron DECON can handle process temperatures between - F and +350 F (- C and +175 C). Pressure Range/End Connections Flanged end connections per ANSI B.1 for 50PSIG and 2500 PSIG service are available. A variety of other end connections is also available including: Butt Weld, Socket Weld, Mechanical joint flanges per AWWA C1 or C111, as well as plain-end designs.

Piping Requirements Designed for full-pipe flow,decon flow meters may be mounted either horizontally or vertically. For recommended upstream piping, refer to DECON Engineering Technical Manual Energy Considerations Figure 1 compares the head-loss of the DECON design with that of other primary flow elements. The pressure recovery of the DECON Venturi Tube means reduced pumping costs. The DECON Venturi has a shorter laying length and exhibits better recovery than typical classical and modified venturi meters. Design Concepts The DECON Venturi is designed to provide a high degree of accuracy with unquestionable and predictable performance. Key to this design is the following: Accuracy: Static inlet and throat pressure sensation provides a highly accurate, stable, and predictable flow measurement signal for flow rates with pipe Reynolds numbers as low as 75 000. Beta Ratio DECON Venturi Tubes are available with a wide range of diameter ratios (d/d). This provides users with accurate flow measurement over a broad range of flow rates for a given line size. Reliability: The DECON Venturi Tube is free of protrusions and sharp-edged, debris-collecting annuli. Static pressure taps reduce flow noise. The internal contour is designed to minimize the buildup of solids and deter erosion, corrosion, and scaling. Energy Savings: DECON Venturi Tubes operate with minimal head-loss. This results in less energy consumption, lower operational costs, and a lower cost of ownership.

This sizing table can be used as a guide to aid the user in choosing the proper DECON Venturi Tube for a given application. Depending on the details of that application, a more appropriate selection, or a more accurate estimation of the performance of a given selection, may be available. DECON Engineering encourages users to contact their local DECON representatives, or call us directly, for definitive sizing information.

DIESEL LOCOMOTIVE TURBOCHARGER FLOW METER " DIAMETER WITH A.17" Diesel locomotive turbocharger flow meter 24.64" diameter with an.64" throat "x4.35" DVT- FRP Venturi w/3 STN. STL. FLNG. x.00 DVT- Venturi Flowmeter - Ready to go THROAT " DVT- Venturi "x.960 w/150 C.S. FLNG "x4.35" DVT- FRP Venturi w/3 STN. STL. FLNG. 96" Vinyl ester fiberglass universal venturi tube manufactured by DECON for BIF. Special " Reverse Flow FRP Venturis Bi-directional flow measurement

Venturi Flow Meter- Model DVT- Description: The DVT- is an all fiberglass design, utilizing DERAKANE Epoxy Vinyl Ester Resin. It is non-corrosive, self scouring, dimensionally stable and can be used with line temperatures of up to 0 degrees F with standard resin and up to 250 degrees F with high temperature resin. The DECON DVT- can be supplied with bronze, stainless steel or other metal throat materials. The high and low pressure connections are 3 stainless steel. The Venturi is supplied ready to install with integral neoprene flange gaskets. Size range is for piping from 3/4" to 1". The DVT- is a short laying length design featuring high accuracy and Low Permanent Pressure Loss. The flow conditions within the inlet section allow for closer coupling with upstream pipe fittings. Should pressure drop be of importance in a particular piping network, the outlet cone can be extended to satisfy the user's head loss requirements. Specifications: The flow meter shall be of the differential pressure producing type for insertion within the pipe line. The inlet shall consist of a conic convergent section for flow conditioning. The throat inlet section included angle shall not exceed 22 degrees and shall have a minimum length of 0.5 times the throat diameter. The throat section shall be cylindrical with a length at least 0.5 times the throat diameter and shall have sharp intersections to support a protected and stable throat pressure profile. Meters with blended radii shall not be considered. Devices amplifying the differential pressure by causing a change in the direction of the flow stream within the throat shall not be considered. The outlet cone shall have an included angle of degrees. The outlet cone length may be selected to minimize laying length or to maximize pressure recovery. The entire flow meter, inlet section, throat section, outlet cone and integral flange shall be fabricated from thermosetting epoxy vinyl ester resin, reinforced with not less than % fiberglass by weight. Pressure connections shall be 3 stainless steel. The pressure connecting passage shall be within the integral mounting flange. The device shall be designed for mounting between ANSI flanges and shall include flange gaskets. The metering element shall have single high and low pressure connections. The manufacturer shall furnish flow versus differential curves to the design engineers for approval. The device performance and metering similitude shall be substantiated by the manufacturer's traceable independent testing. Performance substantiation shall include coefficient value, predictability, effects from installation and line pressure loss from hydraulic shape. The meters coefficient shall be independent of line size and shall be constant and predictable at low Reynolds numbers. The un-calibrated accuracy shall be at least + 0.75% of actual flow based on 2 standard deviation values calculated from a significant sample size. The device shall be a DECON DVT- or approved equal. DVT- PVC Venturi inserted in schedule 40 PVC pipe with 3 stainless steel pressure taps calibrated for air service by CEESI

Capacity and Dimensions DVT- Rate of flow in gallons per minute @0 inches of water differential Estimated shipping weight: LBS size D d B L 150F 0F tf Dci Ei Eo GPM Lbs. 6a 6b 6c 6 6 6 2.60 3.50 4.3 0.4467 0.5967.7.0.9.750.750.750 9.75 9.75 9.75 5.7 5.7 5.7 7.4 5.2 3.3.5.0 6.7 406 750 1153 9 a b c 3.50 4.770 5.760 0.4475 0.5963 27.9 21.7.9 11.000 11.000 11.000 7.6 7.6 7.6.3 7.4 4.9. 13.4 9.1 724 1332 50 a b c 4.770 5.760 7.0 0..4770 0.5760 34.1 2.7.9 75 75 75 9.5 9.5 9.5.5.1 6.5.7 17. 11.5 93 1923 33 a b c 5.760 7.0.640 0.400 0.6000 40.9 32.7 22.9.5.5.5.225.225.225 11.4 11.4 11.4 11.7.1 24.9.2 13.9 7 3 46 26 22 a b c 6.260.640.00 0.4471 0.6171 49.9 36.7 26.9 17.750 17.750 17.750 19.5 19.5 19.5 19.1 9.7 29.6 22.5.2 22 4413 627 40 35 a b c 7.0.00 11.5 0.4500 0.60 56.7 40.6..250.250.250 2 2 2 21.9.9 11.3 33.9 24.9.6 29 6050 0 50 a b c.640.00.960 0.400 0.5600 61.9 5.3 34.7 21.625 21.625 21.625 23.500 23.500 23.500 17.1 17.1 17.1 23.5.0. 37.5 33.5 21.0 45 554 371 65 55 45 a b c.00 11.5.400 0.5040 0.5760 66.6 5.3 3.6 23.75 23.75 23.75 25.750 25.750 25.750 19.0 19.0 19.0 25.0 21.4.3 40. 36.0 23.4 5 7695 07 0 70 60 24a 24b 24c 24 24 24 1.400 17.040 0.400 0.6000 0.70 2.6 66.0 47. 2.250 2.250 2.250.500.500.500 22. 22. 22. 31.5 24.4 17.9 50.2 40. 29.0 754 15 17774 5 1 95 a b c.960 17.040 21.600 0.43 0.560.1 9.0 57.9 34.750 34.750 34.750 37.500 37.500 37.500 2.5 2.5 2.5. 32. 21.5 64.0 54.9 35.1 9465 70 2 2 0 0 36a 36b 36c 36 36 36 17.040 21.600 25.9 0.4733 0.6000 4. 99.1 69.5 4 4 4 44.000 44.000 44.000 34.2 34.2 34.2 47.9 36.6 25.9 75.7 61.2.3 9 27349 415 30 3 20 a b c.7 25.9.240 0.4457 0.6171 9.7 1.5 1.0 4.000 4.000 4.000 50.750 50.750 50.750 39.9 39.9 39.9 5.7 40.9.2 9.5 6.1 49.3 19794 39723 56500 50 500 4 4a 4b 4c 4 4 4 21.600.240 34.560 0.4500 0.60 170.5 2.0 92.6 54.500 54.500 54.500 5.750 5.750 5.750 45.6 45.6 45.6 66.7 45.3 34.7 2.3 75.1 56.4 26369 54443 7379 0 740 600