1 LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have made Lo Torc valves the choice of high pressure plug value users, worldwide: Provides Outstanding Value Even though it leads the industry in quality and performance, the Lo Torc valve, size for size and service for service, is priced with or below every other high pressure plug valve on the market even valves without stainless steel plugs. Helps Reduce Valve Replacement Costs The rugged construction of the Lo Torc valve provides long, dependable service under severe conditions. The stainless steel cylindrical plug is heat treated to help eliminate galling during operation and provides maximum resistance to corrosion. Meets A Broad Range of Operating Requirements Lo Torc valves perform dependably at high working pressures. The sealing principle of the valve compensates for body deflections. Each valve is hydrostatically tested to the pressure specified by API 6A. Offers Installation Versatility Lo Torc valves are lightweight. This feature makes the valve suitable for many applications, including mobile installations. Helps Reduce Maintenance Costs The Lo Torc design provides for in-line maintenance. Repair or maintenance can be

2 accomplished in minutes with the valve body left in the line. Total disassembly of the entire valve involves removing only two capscrews, adjusting nut, and handle adapter or wrench. Every part in the Lo Torc valve may be replaced with standard parts. None of the parts requires factory return of the valve for servicing. Even in high pressure services, the Lo Torc plug valve is easy to operate. Unique design characteristics make this possible: 1. The cylindrical plug eliminates jamming or wedging induced by pressure acting against differential areas (a problem inherent with a tapered plug). 2. The plug is further pressured balanced by identical stem seals at each end. This feature eliminates costly and inefficient thrust bearings. 3. A initial seal between the plug and valve inserts is obtained without lapping, selective assembly, or excessive force. The valve inserts are tapered on the OD to match the valve body cavity. The inner surfaces of the inserts are precision ground to exactly the same diameter as the plug. The inserts are parted into identical halves that, when aligned in the valve body by using the adjusting nut, transmit a firm, uniform clamping action to the sealing area. 4. The plug and inserts are free to "float" downstream to compensate for temporary body deflection. As pressure is increased, the seal between plug and downstream insert half is made more effective. Since only a small area is under direct mechanical bearing, the operating torque does not become excessive. (In most other valve designs, the entire plug surface contacts the body and is subjected to frictional forces.) 5. Frictional forces are also reduced by the design of the stationary o-ring seal between inserts and body cavity. Differential pressure acts on the section of the insert sealed by the o-ring, transmitting a force against the plug. Since the seal area is smaller than the bearing area, this compressive force is considerably less than similar forces encountered in valves that do not have this design. Reduction of this force is directly responsible for reducing operating torque without sacrificing seal efficiency.

3 1. Valve body. The Lo Torc valve body is alloy steel, heat treated for extra strength and durability for high pressure service. 2. Plug design and material. The balanced cylindrical design of the plug (or core) eliminates longitudinal loading. To resist corrosion, the plug is made of stainless steel (standard on every Lo Torc valve). 3. Valve inserts. The valve inserts are tapered on the OD to provide easy adjustment for maximum sealing and plug alignment. The inserts are machined with a raised surface surrounding the o-ring groove. This raised surface (boss) is the only portion of the insert which contacts the valve body and serves as the bearing area on the plug. This design reduces the torque required to operate the valve. Various types of inserts are available. Ductile iron or cast iron inserts (depending on size) are recommended for general fluid service applications. Sealing is due to metal-tometal contact between the insert and the plug. For sour or corrosive service, aluminum bronze inserts are available. 4. End connections. The end connections are hammer union, threaded, or flanged. Flanged connections conform to the dimensional and material requirements of API 6A. Grayloc hubs, butt welds, and other custom end connections also are available. 5. Adjusting nut. The adjusting nut is alloy steel. An o-ring seal is provided around the adjusting nut. 6. O-ring seals. For standard service, 90-durometer nitrile o-rings seals are recessed into grooves in each insert and below the adjusting nut threads. For corrosive applications and temperature extremes, Teflon or fluoroelastomer o-rings are available.

4 7. Plug seals. The stem diameters at the top and bottom of the plug are sealed by specially designed packing rings made of 75 durometer nitrile permanently bonded to brass reinforcing washers. For moderate temperatures with corrosive fluids or solvents, seals of fluoroelastomer with a stainless steel backing ring are available. For applications involving extreme temperatures or the handling of highly corrosive media, a Teflon seal ring, self-energized by an inconel spring, can be provided. Maximum service temperatures are 250 F for nitrile and fluoroelastomer and 300 F for Teflon. 8. Lubrication system. Lubricant is supplied through the conveniently-placed grease fitting, giant buttonhead type. The lubrication chambers above the below the plug are connected by recesses between the two valve inserts. 9. Valve operation. Full operation of the valve requires only a quarter turn (90 ) of the plug. A steel wrench or a cast steel handle adapter, equipped with equidistant operating bar sockets is available for all valves with bore sizes from 1 in. through 3-1/8 in. This socket design is intended to simplify operation of the valve, regardless of its installed position or location. An operating bar is also available for use with the handle adapter. Valves with 3-1/16-in. and larger bores are operated with a gear operator. Pneumatic or hydraulic actuators are available on special order for all valve sizes. 10. Sour service. Valve assemblies for sour service conform to NACE MR Plugs of monel or 316L stainless, aluminum bronze inserts, and seals of Teflon or fluoroelastomer are used. 11. Certification. All Lo Torc plug valve assemblies are traceable. Material chemical certificates and pressure test certificates are available for any valve assembly. Valves identified as "certified" also have

5 mechanical properties included with the material certificates. Certificates should be requested at the time of ordering. Lo Torc Plug Valve - Threaded Ends Female API Line Pipe Threads * Available on special order. ** Part number includes gear operator. 1 Lo Torc valves for handling sour gas/fluids conform to NACE specifications for H2S service. These valves incorporate aluminum bronze inserts, Monel or 316L plugs, Teflon or fluoroelastomer seals and specially heattreated components. 2 Handle adapter is standard and is furnished with 1-1/2-in. regular opening valves.

6 Female External Upset Tubing Threads Ring joint type flanged ends are standard on Lo Torc valves. Other flanged end connections are available on special order.

7 Gear operator for 4-1/16 in., 2,000, 3,000, and 5,000 full opening Lo Torc plug valves with flanged ends.

8 Flanged Ends - Part Numbers and Dimensions * Available on special order. 1 Lo Torc valves for handling sour gas/fluids conform to NACE specifications for H2S service. These valves incorporate aluminum bronze inserts, Monel or 316 plugs, Teflon or fluoroelastomer seals, and specially heattreated components. 2 Part No. includes gear operator. 3 Straight bore diameter. 4 Does not include gear operator. Operating wrench must be ordered separately. Not available. 3-1/16 in., 10,000 full opening and 4-1/16 in. 10,000 regular opening flanged valve. 10,000 WP comes with gear operator as standard.

9 These valves are available with special end connections for a wide variety of applications and with working pressures ranging as high as 15,000 psi (20,000 psi test). All design and operating features of the regular Lo Torc plug valve are included in special service valves. Lo Torc Plug Valve Specifications - Special Service Valves - Line Pipe Threads * Part number includes handle adapter ** Part number includes gear operator

10 Other Special Valves In addition to the valves shown, valves with special threads, special flanges, unequal flanges, flanged by threaded connections, or any other type of end connections can be furnished upon special order. Order by size, pressure, and catalog number. 1 in. through 2 in. sizes Lo Torc Plug Valves with Union End Connections 1 Overall length (Dimension A) is face to face of the thread half to nut body only. The extension of the wing nut is not indluded. 2 Lo Torc plug valves with 2-in and 3-in connections are available with certification: part numbers (1 in.), (2 in.) and (3 in.). Product certificates are available request when ordering.

11 Weights and dimensions are the same as given for the standard, 1-in., 2-in., and 3-in. valves listed above. Other sizes available on request. 3 Operating torque is given for direct stem operated valves only, and at maximum rated working pressure. The torque given is an average reading of new valves tested with water. 3-in. and 4-in. size valves are equipped with manual gear operators so direct stem operation is not required. 3 in. and 4 in. sizes CAUTION: The fact that a valve has never leaked in service does not necessarily mean that the inserts do not need to be replaced. The inserts may wash out and cause the valve body to erode before leakage is noted. A planned program of maintenance at specific intervals is the key to keeping downtime and repair cost at a minimum. For Lo Torc plug valve applications involving throttling or choking, the all metal inserts should be used. Lo Torc Valve Operation and Care Proper operation and maintenance can help extend the service life of Lo Torc valves. Due to widely varied applications, no specific frequency of maintenance or in-service inspection for the Lo Torc plug valves can be recommended. Periodic and frequent inspection of each valve will provide a basis for predicting the life or usefulness of the plug and inserts. Replacing these parts when they are eroded or worn will help prevent any erosion of the body. Disassembly and Reassembly Instructions Disassembly Remove the wrench (15) or handle adapter (2), with stop collars (14). Loosen adjusting nut (7) with operating bar or hex wrench. Remove adjusting nut, plug

12 (12) and inserts (10). If necessary, place a wooden block on top of the plug stem and tap downward. At this point, the valve body (1) should be inspected for any interior erosion or pitting. O- ring (11) on the inserts should be replaced if needed. The o-ring (8) sealing the adjusting nut should also be replaced if worn. Replacing the plug stem packing (9) at the top and bottom of the plug is usually necessary. If the valve shows signs of leakage, or if inserts show any excessive wear or pitting, the inserts should be replaced with standard parts (see part listing on back page). Wipe all old lubricant from inside the valve body. Reassembly Install o-rings in recesses of inserts and in adjusting nut groove. Install plug stem seals (9) in recesses in the top of the valve body and in adjusting nut. The seal backing ring is to be positioned away from pressure. Coat cleaned plug, inserts, and adjusting nut (threads) with recommended plug valve lubricant.

13 Exploded View 2-in. Lo Torc Plug Valve Fill void spaces inside the body with the same lubricant. This lubricant may be ordered in 3/4-lb packages under part number Install lower end of plug through adjusting nut and push down to shoulder. Use capscrews, flat washer, and lock washer to secure plug to adjusting nut. Tighten capscrew. Check for proper positioning of insert retaining pins(13) inside valve body. Place inserts on adjusting nut around plug, aligning flow holes in inserts with hole through

14 plug. Place plug, inserts, and adjusting nut into valve body with insert retaining pins keying into slots in inserts. Tighten adjusting nut into body with prescribed torque for adequate sealing (see adjustment below). Install stop collars and handle adapter (or wrench) on top of valve. Be sure flow indicators are in line with the slot in the top stem of the plug. Rotate plug several times to distribute excess lubricant through flow passage of body. Lubricate the valve through the grease fitting(3) on top of the valve body to insure total filling of the void spaces inside the valve. Valve Adjustment at Zero Pressure The proper adjustment of a Lo Torc plug valve is imperative to maintain tight sealing under pressure. The inserts should be adjusted to give the following torque to rotate the plug. (This adjustment is made by tightening or loosening the adjusting nut(7). 1-in. valves ft-lbf 1-1/2-in valves ft-lbf 2-in. valves ft-lbf 2-1/2-in. valves ft-lbf 3-in. valves ft-lbf 4-in. valves ft-lbf Extremely high working pressure may require torque settings at the upper end of the prescribed range to properly seal the valve. If so, this higher torque adjustment should be maintained by checking the adjusting nut at regular intervals. Repair Kits - Lo Torc Plug Valves Each kit includes all components necessary to renew one Lo Torc Plug Valve Plug 1 Inserts 1 set O-ring-Insert 2 O-ring-Adj. Nut 1 Seals-Stem 2 Lubricant 1

15 Repair Instructions 1 Lo Torc Plug Valves - Replacement Parts List

16 1 Aluminum bronze is suitable for standard H2S service. 2 Listed seal fits seal glands of.5 in. depth. For glands.25 inch depth use teflon seal part no Teflon plug stems and Teflon O-rings used in H2S service valves. 4 Valves with a pin part number for loc 16 are to have loc 16 inside of pin loc13. 5 Monel and 316 stainless for H2S service. 6 Plug Stem seals of Viton material w/stainless steel back-up ring: for 1 in. and 1.3 in. sizes; for other sizes. Viton O-rings; 7.XXXXX where XXXXX is the same 5 digits after the decimal point of the nitrile O-ring. Send questions or comments about this site to Halliburton Service Center or call U.S. (877) or outside U.S. (281) Copyright 2008 Halliburton. All Rights Reserved. Terms and Conditions

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...

More information

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...

More information

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

DeZURIK 3-20 BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.

More information

Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997

Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997 Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47

More information

Easy Tool Retracting System CMC-SR2159ER36

Easy Tool Retracting System CMC-SR2159ER36 Easy Tool Retracting System CMC-SR2159ER36 Pepperl+Fuchs, Inc. 1600 Enterprise Parkway Twinsburg, Ohio 44087 Phone: +1 330 486 0002 e-mail: pa-info@us.pepperl-fuchs.com Mounting the Easy Tool Refer to

More information

Mueller B-101 and A-3 Drilling and Tapping Machines

Mueller B-101 and A-3 Drilling and Tapping Machines TM TM Mueller and Drilling and Tapping Machines A guide to selecting Mueller Equipment Mueller TM TM and Drilling and Tapping Machines When it comes to line stopping and drilling and tapping technology

More information

Round Housing with Side Ports

Round Housing with Side Ports Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End

More information

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator 2945 A 1" SQUARE STEM 9" MAX. = 10" MIN. = 7" FIELD ADJUSTMENT INSTRUCTIONS 1. Remove the top section from

More information

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by

More information

AXLE SHAFTS - FRONT. 1998 Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION

AXLE SHAFTS - FRONT. 1998 Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION AXLE SHAFTS - FRONT 1998 Pontiac Bonneville 1998-99 DRIVE AXLES FWD Axle Shafts - Cars - "C", "G" & "H" Bodies GM Aurora, Bonneville, Eighty Eight, LeSabre, LSS, Park Avenue, Regency, Riviera MODEL IDENTIFICATION

More information

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,

More information

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT INDEX AMERICAN - DARLING 5-1/4 IN. B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation and Maintenance...

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION Mueller Pipe Repair Products A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION MUELLER STAINLESS STEEL REPAIR CLAMPS Mueller offers a full line of stainless

More information

1.8 CRANKSHAFT OIL SEALS

1.8 CRANKSHAFT OIL SEALS SERIES 60 SERVICE MANUAL 1.8 CRANKSHAFT OIL SEALS An oil seal is fitted between each end of the crankshaft and the bores of the flywheel housing and gear case cover to retain the lubricating oil in the

More information

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY 82-13-1 O-Ring (Rear) The Lead Screw Assembly is shipped separately. Note: Install Electrical and Pneumatic Circuitry. Be Sure electrical and pneumatic

More information

NEWCO VALVES Newmans Inc., Newmans Valve Ltd. NEWCO/OIC Cast Valve Operation & Maintenance Manual

NEWCO VALVES Newmans Inc., Newmans Valve Ltd. NEWCO/OIC Cast Valve Operation & Maintenance Manual NEWCO VALVES Newmans Inc., Newmans Valve Ltd. NEWCO/OIC Cast Valve Operation & Maintenance Manual TABLE OF CONTENTS 1. Introduction and Safety Information... 1 1.1. Introduction... 1 1.2. Safety Information...

More information

Repair of Hyd-ro-ac Actuators

Repair of Hyd-ro-ac Actuators Repair of Hyd-ro-ac Actuators OVERHAUL INSTRUCTIONS SS-.2A-1V SS-.5A-1V SS-.5A-2V Read the entire contents of these instructions before installing the actuator and before making any connections to the

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Dive Rite 200 & 300 Bar Isolator Manifold Service Manual Principal Photography and Text by Pete Nawrocky Copyright 2003 Lamartek Inc. D/B/A Dive Rite 0 Warning This manual is only to be used as a guide

More information

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water 1 Foreword 1.1 Thank you for choosing one of the range of AEON's BS standard valves. For safety purposes, the user shall read this instruction to fully understand the operation of the product. 2 AEON Design

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 4195 AND 495 SIZES GG - AL SECTION TSM 144 PAGE 1 of 10 ISSUE D CONTENTS Introduction....................... 1 Safety Information.................... 2

More information

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES

More information

VALVEWORKS USA OPERATION AND SERVICE MANUAL FOR MODEL FM 2 4-1/16 GATE VALVE

VALVEWORKS USA OPERATION AND SERVICE MANUAL FOR MODEL FM 2 4-1/16 GATE VALVE OPERATION AND SERVICE MANUAL FOR MODEL FM 2 4-1/16 GATE VALVE INTRODUCTION In appreciation to our customer for purchasing our product, we have prepared this Operation Manual to assist you in the Operation,

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

MP8000 Series Pneumatic Valve Actuators

MP8000 Series Pneumatic Valve Actuators 14-1161- 9, Rev. A Technical Bulletin MP8000 Issue Date March 2016 MP8000 Series Pneumatic Valve Actuators Pre-Assembly Details Page 3 MP8000 Actuator Components 3 Tools Required to Assemble an MP8000

More information

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12 DUAL BEVEL COMPOUND MITER SAW B27A PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510

More information

KF Needle & Gauge Valves

KF Needle & Gauge Valves KF Needle & Gauge Valves Superior Fluid Control Products KF O-Ring & Packed Stem Style Needle Valves KF Needle Valves combine rugged construction, dependability and leak-free performance at high and low

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

Fisher 249 Caged Displacer Sensors

Fisher 249 Caged Displacer Sensors Instruction Manual 249 Caged Sensors Fisher 249 Caged Displacer Sensors Contents Introduction... 1 Scope of Manual... 1... 2 Type Number... 3 Educational Services... 4 Maintenance... 4 Cleaning the Cage...

More information

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303 WATER MIST HAND PORTABLE FIRE EXTINGUISHERS Model B270 ¾ Gallon Model B272 2 ½ Gallon INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 6303 All fire extinguishers should be installed, inspected

More information

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19 Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR

More information

Pump Shaft Sleeves - Stratford Engineering

Pump Shaft Sleeves - Stratford Engineering Pump shafts are usually protected from erosion, corrosion, and wear at seal chambers, leakage joints, internal bearings, and in the waterways by renewable sleeves. The most common shaft sleeve function

More information

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY

More information

ENGINEERED & PROCESS VALVES. Installation, Operation and Maintenance Manual GENERAL VALVE. Twin Seal Double Block and Bleed Plug Valve GENERAL VALVE

ENGINEERED & PROCESS VALVES. Installation, Operation and Maintenance Manual GENERAL VALVE. Twin Seal Double Block and Bleed Plug Valve GENERAL VALVE GENERAL VALVE Twin Seal Double Block and Bleed Plug Valve GENERAL VALVE 2 TABLE OF CONTENTS GENERAL VALVE TWIN SEAL Installation.... 4 Operation.... 5 Series 400, 800 & 900 Integral Bushing/Retained Ring

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

Service Manual Rol-Lift

Service Manual Rol-Lift R 2000 Service Manual Rol-Lift Series: T and E Developed by Generic Parts Service This manual is intended for basic service and maintenance of the Rol-Lift pallet jack. The pallet jacks you are servicing

More information

Fire Hydrant Troubleshooting

Fire Hydrant Troubleshooting Fire Hydrant Troubleshooting Pulsation or chatter during opening and flow of water from hydrant. Loose condition in stem at lower valve plate nut. Tighten lower valve plate nut and secure with SS lock

More information

Drive shaft, servicing

Drive shaft, servicing Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,

More information

Step-by-step instructions:

Step-by-step instructions: Spark plug thread repair for Ford Triton cylinder heads Step-by-step instructions: Identification Installation Verification Specifically designed and tested for 4.6L, 5.4L, and 6.8L 2 and 4 valve heads,

More information

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS PART NUMBER: 132581 REVISION: A RELEASE DATE: 24 March 2000 Page 1 of 10

More information

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification OWNER S MANUAL Model MH1230 Important Safety Instructions Assembly Instructions Parts and Hardware Identification Pallet Jack CAUTION: Read, understand and follow ALL instructions before using this product

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification... OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3

More information

TUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-2

TUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-2 Part #: HT-2 1965-82 CORVETTE O-RING CONVERSION REAR CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette

More information

High Pressure Equipment Pressure Vessels and Reactors Index

High Pressure Equipment Pressure Vessels and Reactors Index Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard

More information

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,

More information

S&G Model 2937 Group 1 Combination Lock

S&G Model 2937 Group 1 Combination Lock Installation and Combination Changing Instructions S&G Model 2937 Group 1 Combination Lock NOTE: READ COMPLETE INSTRUCTIONS BEFORE INSTALLATION These instructions should be followed when installing the

More information

The Ford Model A Water Pump

The Ford Model A Water Pump The Ford Model A Water Pump George Washington Chapter, Inc. 3903 Old Lee Highway Fairfax, VA 22030 1 Table of Contents Introduction/Specifications.. 3 1. Water Pump Inspection and Removal. 4 a. Removal..

More information

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations Instruction Manual 1061 F & G Actuator Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...

More information

Rebuild Instructions for 70001 and 70010 Transmission

Rebuild Instructions for 70001 and 70010 Transmission Rebuild Instructions for 70001 and 70010 Transmission Brinn, Incorporated 1615 Tech Drive Bay City, MI 48706 Telephone 989.686.8920 Fax 989.686.6520 www.brinninc.com Notice Read all instructions before

More information

STEERING SYSTEM - POWER

STEERING SYSTEM - POWER STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and

More information

Series 2700A Control Valve. Operation and Maintenance INTRODUCTION

Series 2700A Control Valve. Operation and Maintenance INTRODUCTION INTRODUCTION Scope This instruction manual includes installation, operation and maintenance information for 1" through 8" Norriseal Series 2700A Control Valves. Please refer to separate manuals for instructions

More information

DeZURIK 3" (75MM) & LARGER ECCENTRIC PLUG VALVES

DeZURIK 3 (75MM) & LARGER ECCENTRIC PLUG VALVES BULLETIN 12.00-1C SUPERSEDES 12.00-1C & 12.60-1A JUNE 2014 DeZURIK 3" (75MM) & LARGER ECCENTRIC PLUG VALVES www.dezurik.com The DeZURIK Eccentric Plug Valve In thousands of installations worldwide, DeZURIK

More information

Trunnion-Design Ball Valves

Trunnion-Design Ball Valves Trunnion-Design Ball Valves 12" 20" (DN 300 500) Series 7150 12" (DN 300) Series 730S 12" 20" (DN 300 500) Series 7300 14" 24" (DN 350 600) Series 9150 14" 24" (DN 350 600) Series 9300 Installation, Maintenance

More information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard

More information

TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-1

TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-1 Part #: HT-1 1965-82 CORVETTE O-RING CONVERSION front CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette

More information

2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure

2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure 2100 AD 015 0009 Mirror Elevator Ball Nut Replacement Procedure Derek Guenther 1/28/2015 Rev. Purpose The purpose of this document is to describe the procedure necessary to replace one of the ball nuts

More information

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120 An industry leader in underground and in-plant applications. BUTTERFLY VALVES STYLE 4500 3 24 STYLE 1450 30 54 Consult factory for sizes 60 120 C504 Class 150B & 250B M&H Valve is a division of McWane,

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

DiscPlus DX195 and DX225 Air Disc Brakes

DiscPlus DX195 and DX225 Air Disc Brakes Revised 11-04 Technical Bulletin Revised 1 Technical 11-04 Bulletin DiscPlus DX195 and DX225 Air Disc Brakes Inspection, Installation and Diagnostics Air Disc Brake Inspection Intervals and Procedures

More information

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids The AMERICAN Mechanical Joint was developed by the American Cast Iron Pipe Company and first marketed in 1929. Since that time, millions

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

FLANGED END BALL VALVE

FLANGED END BALL VALVE Specification: FLANGED END BALL VALVE - Chem Oil s two-piece ball valve has been designed to handle extreme service applications with unsurpassed reliability. Valve body machined from solid wrought material

More information

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE 4500 3 24 STYLE 1450 30 54. Consult factory for sizes 60 120 An industry leader in underground and in-plant applications. BUTTERFLY VALVES STYLE 4500 3 24 STYLE 1450 30 54 Consult factory for sizes 60 120 C504 Class 150B & 250B M&H Valve is a division of McWane,

More information

Baumann 24000SB Barstock Control Valve

Baumann 24000SB Barstock Control Valve Instruction Manual 24000SB Valve Baumann 24000SB Barstock Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Disassembly...

More information

Fisher CV500 Rotary Globe Control Valve

Fisher CV500 Rotary Globe Control Valve Instruction Manual CV500 Valve Fisher CV500 Rotary Globe Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 3 Maintenance...

More information

BOWIE PUMPS OPERATION - MAINTENANCE

BOWIE PUMPS OPERATION - MAINTENANCE BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped

More information

Fisher CV500 Rotary Globe Control Valve

Fisher CV500 Rotary Globe Control Valve CV500 Valve D101606012 Product Bulletin Fisher CV500 Rotary Globe Control Valve The Fisher CV500 Cam Vee-Ball control valve combines the rangeability of the cammed-segmented V-notched ball, with the inherent

More information

Mechanical Joint Restraints

Mechanical Joint Restraints -15 PVC Pipe Restrainer The PVC mechanical joint restrainer eliminates the need for thrust blocking, tie rodding, or harnessing mechanical joint fittings when they are used with PVC pipe. The key to the

More information

RMF Engineering 23 05 23

RMF Engineering 23 05 23 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

SINGLE STAGE INLINE FIRE PUMP

SINGLE STAGE INLINE FIRE PUMP MODEL 383 SINGLE STAGE INLINE FIRE PUMP INSTRUCTION AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY CHEXTER TM FITS YOUR APPLICATION, PROFITABLY Commercial Construction CHEXTER TM Check Valves are economically used in chilled and hot water air conditioning systems, refrigeration and other piping and

More information

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE. www.sharpevalves.

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE. www.sharpevalves. Valves, Automation & Controls series 8 /99 & FS8 /FS99 HIGH PERFORMANCE -PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE www.sharpevalves.com Design & Features SHARPE VALVES - SERIES 8/99 Fire

More information

White Industries Rear Hub Instructions

White Industries Rear Hub Instructions White Industries Rear Hub Instructions Tool required: 2mm allen/hex wrench, 19mm socket, 20mm socket, and mallet. 1. Loosen the set screws located in the adjusting collar by using a 2mm allen wrench inserted

More information

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

BALL VALVES TECHNICAL CATALOGUE

BALL VALVES TECHNICAL CATALOGUE SITINDUSTRIE VALVO VALVES BALL VALVES Ed. 01/NOV-2004 SITINDUSTRIE reserves the right to change, without notice, 1/16 SITINDUSTRIE VALVE DIVISION We are pleased to introduce you to the ball valves manufactured

More information

Front axle components, overview

Front axle components, overview just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,

More information

SERIES 127A AND 4127A STAINLESS STEEL SIZES H, HL, K, KK, L, LQ, LL CONTENTS UNMOUNTED PUMP UNITS

SERIES 127A AND 4127A STAINLESS STEEL SIZES H, HL, K, KK, L, LQ, LL CONTENTS UNMOUNTED PUMP UNITS TECHNICAL SERVICE MANUAL UNIVERSAL SEAL HEAVY DUTY PUMPS SERIES 124A, 4124A, 124AE, 4124AE, AND 4124B CAST IRON SERIES 126A AND 4126A DUCTILE IRON SERIES 123A AND 4123A STEEL SERIES 127A AND 4127A STAINLESS

More information

Machine devices, jig devices

Machine devices, jig devices Machine devices, jig devices 853 K0697 Rolled thread studs DIN 6379 Material: Tempered steel. KIPP Rolled thread studs DIN 6379 Order No. D L B1 B2 Approx. weight g Surface finish: Thread rolled. Class

More information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24 Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical

More information

American- Darling 5¼" B-84-B-5.

American- Darling 5¼ B-84-B-5. -5 Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which

More information

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series

More information

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear DIAMOND Gear Company, LTD. an ERIKS Company Installation, Maintenance, & Operation Manual Declutchable Worm Gear 2016 DECLUTCHABLE WORM GEAR INSTRUCTIONS This is an instructional manual which provides

More information

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS

SECTION 15105 DUCTILE IRON PIPE AND FITTINGS SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections

More information

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Experience In Motion. Valtek Spring Cylinder Linear Actuators Experience In Motion Valtek Spring Cylinder Linear Actuators Valtek Spring Cylinder Linear Actuator Flowserve spring cylinder linear actuators are powerful, compact, high-performance pneumatic actuators

More information

Viking Pump with Motor and Gear Reduction Drive

Viking Pump with Motor and Gear Reduction Drive Viking Pump with Motor and Gear Reduction Drive Mfg: Viking Model: Stock No. SPGP003.2 Serial No. Viking Pump with motor and gear reduction drive. Motor: Ajax Electric Motors. Type DFT100L4. 23/450 volt,

More information

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

Type 119 Control Valve

Type 119 Control Valve Instruction Manual Form 5204 Type 119 December 2009 Type 119 Control Valve Introduction Scope of the Manual This instruction manual provides installation, spring adjustment, maintenance, and parts information

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47) 47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing

More information