Daniel Venturi Tubes and Flow Nozzles Brochure
|
|
|
- Jacob Bennett
- 9 years ago
- Views:
Transcription
1 Daniel Venturi Tubes and Flow Nozzles Brochure
2 Is unaccounted hydrocarbon draining your bottom line? When the stakes are high, any amount of unaccounted hydrocarbon drains the bottom line. That's why companies like yours count on proven measurement technology and industry expertise from Daniel to improve service, reduce cost and add value. Daniel Overview For more than 70 years Daniel has been at the forefront of measurement technology development for the Oil and Gas Industry. Daniel has become a leading figure in the development of the standards that govern orifice measurement around the world. With offices around the globe, Daniel is capable of offering the level of quality and service required by our most demanding clients. Daniel engineers its products to produce the most precise measurement solutions in the industry. Daniel relies on precision manufacturing to ensure that specifications are met or exceeded to offer the best quality product in the marketplace. Page 1
3 Daniel Venturi Tubes Daniel Venturi Tubes Daniel Venturi Tubes serve users with accurate measurement of non-viscous fluids in clean or dirty streams. Venturi Tubes are virtually maintenance-free and corrosion-resistant. Daniel Venturi Tubes are manufactured in strict accordance with ASME MFC-3M and ISO 5167 specifications. These measurement standards provide users with +/-1.0% uncertainty of discharge coefficient. For critical measurement applications flow calibration is recommended, which results in +/-0.25% uncertainty of discharge coefficient. The Daniel Venturi Tube is a low-pressure-drop metering device identifiable by its tapered inlet, tapered outlet and straight, constricted middle section. It offers constant accuracy, low susceptibility to erosion, high-pressure recovery, and installation at any angle from horizontal to vertical. Corrosion-resistant and virtually maintenance-free, this measurement product performs in a wide variety of applications that include air, water, vapor, steam, gas, chemical substances, sludge and slurry applications. For extremely erosive service, internal surface hardening is available. The Classical Venturi is a head pressure device that consists of a convergent cone section, cylindrical bore, and a divergent cone section. The cylindrical bore restricts the fluid flow resulting in a pressure drop. This differential pressure relates to the flow rate by applying Bernoulli's equation. The angled inlet and outlet cones help control the pressure recovery, making the Venturi the most efficient of all the differential meters available. This results in lower permanent pressure loss and greater capacity than other differential meters of the same size. Permanent pressure loss is typically 5% to 15% of the differential pressure, depending on the bore size selected. Features and benefits: Can be used on slurries and dirty fluids Short upstream piping required Low installation costs Lower susceptibility to erosion High pressure recovery Low permanent pressure loss Extended product life with no moving parts Vertical or horizontal installation No moving parts, simple configuration, maintenance-free Availability in 2 to 48-inch sizes. Larger sizes available upon request. Available in all ANSI ratings (depending on line size). Available in wide variety of materials. Page 2
4 Daniel Flow Nozzles Daniel Flow Nozzles The Daniel Flow Nozzle is a differential flowmeter that creates a flow restriction for typically, high-velocity, non-viscous, erosive flows. The rounded design provides a more effective sweep-through of particles in the flow stream, which extends product life by reducing wear and potential damage. Long Radius Daniel Flow Nozzles are manufactured in strict accordance with ASME MFC-3M specifications, which provide users with +/-2.0% uncertainty of discharge coefficient. For critical measurement applications, flow calibration is recommended, which results in +/-0.25% uncertainty of discharge coefficient. ASME PTC-6 compliant flow nozzles are also available for acceptance testing of power generation plants. Daniel Flow Nozzles are erosion-resistant, corrosion-resistant, consistently accurate and virtually maintenance-free. They perform in a wide variety of applications that include air, water, vapor, steam, gas, chemical substances, and high temperature applications. For extremely erosive service, internal surface hardening is available. Flow Nozzles have a smooth elliptical inlet leading to a throat section with a sharp outlet. This restriction in the fluid flow causes a pressure drop, which relates to the flow rate by applying Bernoulli's equation. The smooth inlet of the flow nozzle results in a higher coefficient of discharge than most other differential meters. This higher efficiency means greater flow capacity when compared to most other differential meters of the same size. Features and benefits: Rounded inlet not subject to wear or damage, extending product life Better sweep-through effect for debris and liquids, eliminate damming effect Direct welding into line, eliminating potential of leaking gaskets No moving parts, simple configuration, maintenance-free Availability in 2 to 48-inch sizes. Larger sizes available upon request Available in all ANSI ratings (depending on line size) Available in wide variety of materials Page 3
5 Daniel Meter Tubes Meter Tubes Daniel Meter Tubes are accurate and dependable instruments that adhere to the highest quality standards. They are an integral piece of the Daniel Flow Nozzle and Venturi Tube Meters. Quality Fabrication Close quality control guarantees highly accurate fabrication of Meter Tubes for Daniel Flow Nozzles and Venturi Tube Meters. Special jigs and fixtures are used to assure precise alignment of tube and fitting so there are no steps or offsets. All welds are ground and micrometer readings are made. Testing Radiography and hydrostatic testing is available for Daniel Flow Nozzles and Venturi Tube Meters to ensure measurement accuracy. Micrometer and internal surface roughness readings are recorded and supplied with each meter tube. Paint and Coating A special quick-drying paint is applied as standard on Meter Tubes. Sandblasting and corrosion-resistant coatings are also available. Page 4
6 Daniel Engineered Systems Daniel Measurement and Control is the industry leader in designing, constructing and commissioning of complex oil and gas metering systems to exacting standards. This global organization offers decades of petroleum fiscal flow measurement application experience. Customers rely confidently on Daniel's Systems Group international fabrication facilities, customized engineering and its successes in field-testing and support. From the simplest single-stream skid to complex on-site installations, Daniel Systems delivers both natural gas and liquid petroleum turnkey applications. Daniel Systems designs, constructs and commissions the metering project, blending up-to-the-minute technology with decades of understanding what customers need and expect. Components of a Daniel Systems installation typically include meters, valves, provers, flow-control instruments, instrumentation and read-out equipment and process management components. Computer software and hardware are integrated with the measurement system. Standard calculation methods include AGA3 (now API-MPMS-14.3), ISO 5167, AGA5/7/8, AGA9 and the API Manual for Petroleum Measurement Standards. Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface, database server, and a dedicated PLC for the metering skid/mov interface. Redundancy is often used for custody transfer systems and/or when system integrity is essential. A dedicated Project Manager and Project Team are assigned to each measurement system project. This team is responsible for overall system design and project construction from start to finish. A separate internal QA/QC group reviews all design details, inside and outside fabrication, assembly and system testing. Whether it is a pipeline, offshore production facility or a loading facility for ocean-going tankers, the Daniel Systems group is a proven, single-source solution for customers throughout the world. Page 5
7 Daniel Measurement Services, Inc. Daniel Measurement Services, Inc. takes pride in being there with the right solution for customers with gas and liquid fiscal flow measurement applications. Around the clock and around the world, Daniel Measurement Services has experienced, highly qualified people prepared to assist customers with: Startup and commissioning Preventative maintenance Product repair / upgrades Project management and integration Meter tube inspection and recertification Educational services Remote diagnostics Warranty Plus! The Solution can be a warranty-enhancement program or a remote dial-up check of installed equipment that keeps desired performance a fingertip away. Daniel Measurement Services also offers a series of educational courses essential to customer success, taught at the factory or the customer's location by a credentialed engineer, technician or other trainer. Courses include product instruction on proper operation of Daniel gas chromatographs, ultrasonic meters, presets and other instruments for fiscal flow measurement applications. Daniel Measurement Services' educational courses and the commitment to being the world's leading provider of value-added measurement services afirm that Daniel support of its customers has never been stronger. Page 6
8 Emerson Process Management Daniel Measurement and Control, Inc., Division Headquarters Houston, Texas, USA T: , F: USA Toll Free FLOW Calgary, Alberta, Canada T: , F: Alberta Toll Free Daniel Measurement and Control, Inc. and Daniel Measurement Services, Inc. (collectively Daniel ) are a wholly owned subsidiary of Emerson Electric Co., and a division of Emerson Process Management. The Daniel logo is a registered trademark of Daniel Industries, Inc. The Emerson logo is a registered trademark and service mark of Emerson Electric Co. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time. Daniel does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Daniel product remains solely with the purchaser and end-user. Stirling, Scotland - Europe, Middle East, Africa T: +44 (0) , F: +44 (0) Singapore - Asia Pacific Emerson Process Management Asia Pacific Private Limited T: , F: Daniel Measurement and Control, Inc., All Rights Reserved. Printed in the USA. DAN-GAS-DIF
Daniel Orifice Fittings Brochure. Senior Orifice Fitting, Simplex Orifice Plate Holder, Junior Orifice Fitting, Orifice Flange Union, Meter Tubes
Daniel Orifice Fittings Brochure Senior Orifice Fitting, Simplex Orifice Plate Holder, Junior Orifice Fitting, Orifice Flange Union, Meter Tubes Is unaccounted hydrocarbon draining your bottom line? When
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE
THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPERS THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT www.daniel.com INTRODUCTION Orifice meters are
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Custody Transfer Measurement. with the V-Cone Flowmeter
Custody Transfer Measurement with the V-Cone Flowmeter Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the approval of the McCrometer V-Cone flowmeter for custody
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers
The DL8000 Preset Controller The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers Reliability, ruggedness, flexibility, and accuracy all in one package
Using meters to measure steam flow
Page 1 of 6 April 1998 Plant Engineering SELECTING NEW TECHNOLOGY: PROBLEM SOLVING Using meters to measure steam flow Jesse L. Yoder, Ph.D., Senior Analyst, Automation Research Corp., Dedham, MA Key Concepts
Pump Division MNR MND. Absorber Recirculation Pumps. Bulletin PS-10-32 (E)
MNR MND Absorber Recirculation Pumps Bulletin PS-10-32 (E) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in the world has the
Daniel Measurement and Control FLOW MEASUREMENT TECHNOLOGIES
Daniel Measurement and Control FLOW MEASUREMENT TECHNOLOGIES The Key to Accurate and Reliable Flow Measurement page 4-7 Served Markets page 8-11 REDUCING MEASUREMENT UNCERTAINTY IS OUR BUSINESS Daniel
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
Enhance Your Oil & Gas Production and Transmission Operations
Enhance Your Oil & Gas Production and Transmission Operations SmartProcess Oil & Gas Application Suite Achieve unparalleled productivity with best-in-class application software for critical oil & gas operations.
Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2
Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2 Steve Baldwin Chevron Energy Technology Company Houston, Texas USA Casey Hodges CEESI Measurement Solutions. Nunn, Colorado
CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation
CALDON LEFM 380Ci Gas Ultrasonic Flow Meter Integrating experience, proven technology and innovation VALVES & MEASUREMENT Cameron s CALDON LEFM 380Ci gas ultrasonic flow meter combines world-leading flow
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas
FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS Sami Halilah Dynamic Flow Computers Houston, Texas GENERAL LAYOUT This paper presents information about applications of flow computers in the oil
Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper
2001 Canadian Gas Association Gas Measurement School Winnipeg, Manitoba Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper Prepared by: Dean Mah, P.Eng. Warren Peterson
Integrated Custom Systems
Integrated Custom Systems Compact panels Standard Manifolds & Assemblies Electronic pressure control Custom manifolds & Assemblies Automated test benches S t r e a m l i n e y o u r p r o c e s s Complete
INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM
INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM 1. IS 15663(Part 1):2006 This code covers requirements and recommendations for the design, materials, construction and testing of pipelines made of steel
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager
TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES Randall Messman SW Regional Sales Manager PGI International 16101 Vallen Drive Houston, TX 77041 Purpose Natural
ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.
SUPERIOR PRODUCTS, INC. 20550 MADISON STREET, TORRANCE, CA 90503 ORIFICE PLATES MANUFACTURING STANDARDS: Superior Products manufactures Orifice Plates in strict accordance with the specifications of: AGA.,
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
Measurement Services Inspectorate America Corporation
Measurement Services Inspectorate America Corporation Expert Testing & Inspection Services for the Oil, Gas & Petrochemicals Industry Measurement Services Inspectorate America Corporation applies a client-focused
Rosemount Orifice Plate in Wet Gas
00870-0100-4810 January 2006 Page 1 Rosemount Orifice Plate in Wet Gas This paper discusses the phenomenon of wet gas measurement, definitions, and the need to accurately measure this mixture. This paper
SupportNet Technical Services
TM SupportNet Technical Services Help is Just a Mouse Click Away Introducing SupportNet Technical Services Now you can get technical support for your ROC, FloBoss, Bristol, and ControlWave brand products
Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves
Baumann TM Sanitary and Aseptic Process Valves The Company Fisher Controls International LLC, Baumann Control Valves, is an ISO 9001 certified, PED compliant manufacturer of general utility, precision
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
ROC800L Liquid Application Software
ROC800:SW1 Product Data Sheet D301576X012 January 2015 ROC800L Liquid Application Software The ROC800L Liquid Application Software Suite enables the ROC800 platform to perform API compliant liquid flow
191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES
191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of
Baumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
OIL & GAS PRODUCTION AUDITING
OIL & GAS PRODUCTION AUDITING Wayne C. Dussel Offshore Measurement Supervisor El Paso Production GOM Basic Measurement Audit Steps I. Select location (s) to be reviewed. II. Review contracts, commingling
How To Make A Pressure Relief Valve
0510 First Line of Safety: Farris Engineering Our Company Farris Engineering, a business unit of Curtiss-Wright Flow Control Company, has been at the forefront of the design and manufacture of spring-loaded
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
Engineered Solutions
Engineered Solutions Long established partnerships bring together the world s leading instrumentation companies within BKW. Our manufacturing facility enables us to quickly adapt standard instruments to
Welding Codes and How They're Used (DOD) (ANSI). (AWS), (ASME) (API). not American Welding Society AWS D1.1 AWS D1.2 AWS D1.3 AWS D1.4 AWS D1.
Welding Codes and How They're Used Almost all design, welding, fabrication, material, repair, testing, and inspection requirements are covered under three main governing organizations. Even the Department
GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications
GE Oil & Gas Air cooled heat exchangers Robust and reliable for all loads and applications What it is Air cooled heat exchangers are commonly used in industrial applications where a reliable source of
Oilfield Services Measurement Solutions
Oilfield Services Measurement Solutions Superior flow and density measurement Best-in-class measurement How can I streamline my operations for efficiency without compromising environmental, safety and
Oil and Gas Custody Transfer
By Emerie Dupuis Daniel Measurement and Control, Emerson Process Management Oil and Gas Custody Transfer When money changes hands, flow measurement accuracy matters. When flow measurement is performed
Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve
Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve Problem Gate valves in severe service applications that experience premature trim wear from seat guided discs or leakage
Heating Water by Direct Steam Injection
Heating Water by Direct Steam Injection Producing hot water by direct steam injection provides a solution where large volumes of hot water at precise temperatures are required, and where energy and space
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe
Fire Protection Pumps
Experience In Motion Fire Protection Pumps Pump Supplier to the World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in the world has the depth or breadth
BLADDER SURGE CONTROL SYSTEM
PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures
Micro Motion ELITE CMFS Series Meter
Revolutionize your Coriolis measurement technology Micro Motion ELITE CMFS Series Meter Introducing Emerson s Micro Motion Elite CMFS Series METER Our ELITE CMFS meter delivers unmatched, real-world performance
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative
Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative Problem Fast isolation of a large bore main steam or feedwater line during a pipe rupture that seals flow in both directions.
RITTER Multiple Sonic Nozzle Calibration System
RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases
OFFSHORE POWER. Caterpillar Global Petroleum
OFFSHORE POWER Caterpillar Global Petroleum YOUR OPERATION, CATERPILLAR SOLUTIONS We listened to our customers, invested in research and development, and put 80 years of engine manufacturing experience
POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors
POLARIS AIR COMPRESSOR SERIES engineering excellence stellar performance P - 3 0 0 RELIABLE 100% OIL-FREE ENGINEERED AIR A World Leader for Centrifugal Compressors It s simple: The Polaris Air Compressor
Fisher CV500 Rotary Globe Control Valve
CV500 Valve D101606012 Product Bulletin Fisher CV500 Rotary Globe Control Valve The Fisher CV500 Cam Vee-Ball control valve combines the rangeability of the cammed-segmented V-notched ball, with the inherent
SELECT Hg Ultra-purification of mercury from natural gas
SELECT Hg Ultra-purification of mercury from natural gas SELECT Hg: Ultra-purification of mercury from natural gas Mercury is a naturally occurring contaminant in some hydrocarbons. It is highly toxic
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 9744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FREEZE RESISTANT WALL MOUNTED EMERGENCY EYEWASH
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
Mechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
Fundamentals of Orifice Meter Measurement page 1. Fundamentals of Orifice Meter Measurement. What is an Orifice Meter? How does it work?
Fundamentals of Orifice Meter Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPERS Fundamentals of Orifice Meter Measurement www.daniel.com Fluid meters are divided into two functional groups
GE Oil & Gas. Industrial modules. Turnkey power-generation and compression solutions to increase efficiency, reliability & power in restrictive areas
GE Oil & Gas Industrial modules Turnkey power-generation and compression solutions to increase efficiency, reliability & power in restrictive areas Industrial modules Modern oil and gas operations must
Meter Technician Certification Exam
Meter Technician Certification Exam Revised September 2012 Version 12.0 This exam is designed to test the knowledge of meter technicians in order to attain certification to check the calibration of portable
V-Cone, An Alternative to Orifice Meter in Wet Gas Applications
V-Cone, An Alternative to Orifice Meter in Wet Gas Applications Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the use of the V-Cone differential pressure flowmeter
GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications
GE Oil & Gas Air Cooled Heat Exchangers Robust and reliable for all loads and applications What it is Air cooled heat exchangers are commonly used in industrial applications where a reliable source of
A basic introduction to steam
A basic introduction to steam FOR HOT, COLD, MOIST AND DRY, FOUR CHAMPIONS FIERCE. STRIVE HERE FOR MASTERY Milton 1666 Steam Wonderful Steam Very high heat content Recyclable Clean, non toxic Biodegradable
Stilling Well Recommendations
White Paper June 24, 2009 Stilling Well Recommendations This document describes general requirements for stilling wells used for radar tank gauging applications. Automation solutions for oil & gas, defense
Baumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
Equipment Performance Monitoring
Equipment Performance Monitoring Web-based equipment monitoring cuts costs and increases equipment uptime This document explains the process of how AMS Performance Monitor operates to enable organizations
289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
CSI Oil Analysis Options
Product Data Sheet L-OAOB-101105 October 2005 Machinery Health Management CSI Oil Analysis Options n CSI Oil Laboratory provides accurate and comprehensive industrial oil analysis results you can import
Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.
Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance
Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters
July 10, 2007 - Page 1 Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters General The Bristol 5453-10G indicating pneumatic pressure controller with 624-II control unit, from Emerson
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
Chromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
Process Instrumentation Training Europe. Instrumentation training capabilities
Process Instrumentation Training Europe Instrumentation training capabilities Empower your Staff Striving to optimize plant operation, reduce start-up time, plant down time and even reduce spares inventory?
Ultrasonic Meters: A Natural Choice To Measure Gas Flow
Pipeline & Gas Journal July issue 2000: Ultrasonic Meters: A Natural Choice To Measure Gas Flow by Jesse Yoder, Flow Research, Wakefield, Massachusetts Anyone who is familiar with natural gas flow measurement
Chemical Measurement Solutions
Chemical Measurement Solutions Superior flow and density measurement Best-in-class measurement I need to simultaneously increase production and plant up-time while lowering operations and maintenance costs.
GEOil&Gas. Liquefied Natural Gas. Reliable innovation for the entire LNG value chain
GEOil&Gas Liquefied Natural Gas Reliable innovation for the entire LNG value chain Pushing technological boundaries When GE Oil & Gas introduced its Frame 5 gas turbine driver to LNG liquefaction in 1989,
Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014
Ultrasonic Gas Meters for Industrial and Commercial Applications Ohio Gas Association Technical Seminar March 27-28,2014 Objectives Technology Operation Benefits Applications Approvals and Standards Products
UPM 15010. Figure 1 MPFM installed on well pad
UPM 151 In-line Multiphase Flowmeter Field Trial Comparison vs. Three Phase Flow Separator on Naturally Flowing Shale Wells A. Michael Jones, Independent Flow Measurement Consultant, Travis Gaskill, Daniel
OpenEnterprise. Lifecycle Services
TM OpenEnterprise Lifecycle Services Emerson offers a comprehensive Lifecycle Services approach to help our customers achieve maximum business value and operational excellence Lifecycle Services are Emerson
Lifecycle Services for Syncade Logistics
Service Data Sheet Lifecycle Services for Syncade Logistics Offering the Right Service at the Right Time to Help You Operate Safely, Optimize Asset Reliability and Improve Process Capabilities. Introduction
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
Power Recovery Turbines
Power Recovery Turbines Fixed and Variable Geometry Vertical Horizontal Bulletin PS-90-1 (E) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Smart Operations Management Suite
Lifecycle Services for Syncade Operations Smart Operations Management Suite Service Data Sheet Lifecycle Services for Syncade Operations Smart Operations Management Suite Offering the Right Service at
Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15
The Connection Bulletin for Forged Steel Flow Control Valves CB 15 Flow Control Division Forged Steel Flow Control Valves GRADUATED DIAL AND INDICATOR FULLY GUIDED V-PORT THROTTLING DISC AND INTEGRAL HARD
ABB Flowmeters Review of industrial processing flowmeters
White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in
CCI 100 DPC DRAG Wellhead Production Choke Valve
CCI 100 DPC DRAG Wellhead Production Choke Valve 2 Severe service DRAG choke valve delivers precise wellhead pressure control with superior reliability and life. Improves well production time Enhances
The First Line of Safety
Pilot Operated Pressure Relief Valves The First Line of Safety Pilot Operated Pressure Relief Valves 597C Farris Engineering Pressure Relief Valves Process Pressure Relief Valves Series 2600 ASME NB Certified:
How to Pre-empt a Significant Profit Drain: Nozzle Wear
Experts in Technology Nozzles Control Analysis Fabrication How to Pre-empt a Significant Profit Drain: Nozzle Wear Causes, Detection and Corrective Action Strategies By Jon Barber, ing Systems Co. KEY
Pumps for CO 2 Capture, Transportation and Storage
Pumps for CO 2 Capture, Transportation and Storage Pre-Combustion Post-Combustion Pipeline Injection Experience In Motion Pump Supplier to a Carbon Constrained World Flowserve is the driving force in the
FLASH TANK ECONOMIZER PRODUCT GUIDE
FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
THE RELEVANCE OF TWO DIFFERENT PATH LAYOUTS FOR DIAGNOSTIC PURPOSES IN ONE ULTRASONIC METER
THE RELEVANCE OF TWO DIFFERENT PATH LAYOUTS FOR DIAGNOSTIC PURPOSES IN ONE ULTRASONIC METER MR. JOHN LANSING, SICK MAIHAK, Houston, Texas DR. VOLKER HERRMANN, SICK MAIHAK, Dresden, Germany MR. TORALF DIETZ,
MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS
FIRE DEPARTMENT Bureau of Fire Protection and Life Safety www.cityofsanmateo.org 1900 O Farrell, Suite 140 San Mateo, CA 94403-1332 (650) 522-7940 FAX: (650) 522-7941 TDD: (650) 522-7047 MAINTENANCE AND
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 19 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
FUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801
FUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801 INTRODUCTION The majority of all gas measurement used in the world today is performed by two basic
Chokes. Types Reasons Basics of Operations Application
Chokes Types Reasons Basics of Operations Application Most Common Chokes Positive: Fixed orifice Disassemble to change bean Adjustable Provides variable orifice size through external adjustment Schematic
Determining Lost and Unaccounted For Gas Loss. Duane A. Harris VP Sales and Support Flow-Cal, Inc. 2222 Bay Area Boulevard, Suite 200 Houston, TX.
Determining Lost and Unaccounted For Gas Loss Duane A. Harris VP Sales and Support Flow-Cal, Inc. 2222 Bay Area Boulevard, Suite 200 Houston, TX. USA Introduction Every company involved in the natural
