PROFIBUS PA fault-finding and Maintenance Tools

Similar documents
PROFIBUS fault finding and health checking

PROFIBUS diagnostics and network monitoring

PROFIBUS DP Diagnostics and Network Monitoring Tools

PROFIBUS Diagnostics and Network Monitoring Tools

Introduction to PROFIBUS and PROFINET

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Top Level Design of Automation and Control Systems

PROFINET IO Diagnostics 1

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

PROFIBUS/PROFINET System design

Integrating HART into PROFIBUS DP

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

Process automation engineering tools

Introduction to the Actuator Sensor-Interface

Siemens S7 PLC and FC 300 Profibus

Everything you ever wanted to know about DPV1 diagnostics but were afraid to ask!

Automation Unit TM 1703 ACP Flexible automation and telecontrol

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Research of PROFIBUS PA s integration in PROFINET IO

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Development of a Gateway to PROFIBUS for Remote Diagnostics

SIMATIC PDM software. Siemens FI /1

Conditie gebaseerd onderhoud met PROFIBUS in overeenstemming met NAMUR NE107

PROFIBUS AND MODBUS: A COMPARISON

MINIMAT-EC-Servo Screwdriver Spindles

Configuring PROFINET

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Computer Networking. Definitions. Introduction

CP Page 1342 Mar 2008 Siemens ITS

PROFINET Diagnostics Software and Tools

obems - open source Building energy Management System T4 Sustainability Ltd

ETS4 Diagnostics. KNX Association

The CP provides access to different communication services of the PROFIBUS bus system:

SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG All Rights Reserved.

PROFIBUS. Installation Guideline. for Planning

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

The CP FO provides access to different communication services of the PROFIBUS bus system:

S-series DeviceNet Interface Card

Permissible ambient temperature Operation Storage, transport

Siemens. Partner for the petrochemical industry. chemicals

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Masterclass Maintenance & Management

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

FDT Stand. FDT Standard FDT/DTM. Device Management Technology based on the FDT/DTM standard

Universal Adapters for Remote Monitoring

Using installed Fieldbus Wiring to carry Ethernet Communications

PROFIBUS. Design and. Good Practices

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

API Marine. BMS Presentation. Ballast Measurement Systems

Hirschmann Networking Interoperability in a

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Understanding Device Level Connection Topologies

Welcome to the Introduction to Controller Area Network web seminar My name is William Stuart, and I am a Applications Engineer for the Automotive

A network is a group of devices (Nodes) connected by media links. A node can be a computer, printer or any other device capable of sending and

CONVI. User and Service Manual. Viscolone uk_1.doc. 10. august 2010

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

Partner for automation Water technology

OSM 2007 MONITORING SOFTWARE

Service & Support. How Can You Have Diagnostics Data of IPCs Displayed in WinCC? WinCC, IPC and DiagMonitor. FAQ July Answers for industry.

Understanding Device Level Connection Topologies

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Helmut Schoenfelder, ABB Stotz-Kontakt, UMC100.3 Technical Presentation. ABB Stotz-Kontakt May 18, 2015 Slide 1

Massachusetts Institute of Technology

Application about Communication

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

White paper The future role of ethernet and the trend to decentralised control solutions

Designing VM2 Application Boards

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

IEEE Projects in Embedded Sys VLSI DSP DIP Inst MATLAB Electrical Android

FDI Meets Plant's Device Integration Needs

Workshop PROFINET in Process Automation. Intern / Siemens AG Alle Rechte vorbehalten.

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

C24-CAMANL Video Server/Encoder

Capacitive Touch Lab. Renesas Capacitive Touch Lab R8C/36T-A Family

Flowserve ValveSight DTM installation instructions for the D3 HART Digital Positioner

Mastertech Diagnostic Software Frequently Asked Questions

Product Information Sheet UH36 Hi Pot Tester

Device Type Manager (DTM) Basic HART

Wireless Sensor Networks

Troubleshooting & Diagnostic Procedures

1 Application Description System Topology Hardware and Software Requirements... 3

G3 Series PROFIBUS DP Technical Manual

SMS GSM Alarm Messenger

S-series SQ Controller

Power & Environmental Monitoring

Setup guide. point to point wall plate extenders

Using a Modbus TCP to Profibus PA Gateway by IFAK system

WIRELESS INSTRUMENTATION TECHNOLOGY

Setup and Programming of the. Master Module R72-11Z-SLSASG-028

Transcription:

PROFIBUS PA fault-finding and Maintenance Tools Andy Verwer Verwer Training & Consultancy Ltd PROFIBUS PROFIBUS is a very reliable and cost effective technology. It is common to find extensive installations comprising thousands of PROFIBUS devices operating on complex networks which are connected together via industrial Ethernet. The reliable operation of these networks is essential to maintaining plant productivity. So, what can go wrong? Page 2

The most common PROFIBUS problems Configuration. PLC OS Manufacturing PROFInet / Ethernet/TCP-IP IPC OS Wiring, reflections, wire breaks, short circuits. Process RS 485 or FO PROFIBUS DP MBP PROFIBUS PA? Device removal AS-Interface Interference pickup. Instrument or I/O failure Addressing Page 3 The reliability problem To understand the problem that faces system engineers, consider a modest installation with 1000 devices installed: Each device might exhibit a mean (average) time to failure of 20 years. On average we would therefore expect a failure every 20/1000 years which is approximately a failure each week! We must be able to locate and fix these failures quickly and efficiently. Page 4

Fault categorisation Operational can be categorised in several ways: Peripheral Communication Concerned with the sensor or actuator. E.g. sensor wire break, loss of output power, sticking valve etc. Devices are still communicating. Faults prevent signals reaching their destination. E.g. network wiring errors, interference pickup, reflections etc. Communication is disrupted. Page 5 Peripheral Because the communication remains operational, peripheral can often be located and diagnosed using the communications system itself. Tools and techniques that are useful for locating peripheral on PROFIBUS systems include: Diagnostic reporting using on-line system diagnostics. Engineering tools, protocol analysers, etc. Modern intelligent devices incorporate self diagnostic features that can identify and highlight peripheral. However, tools are still required to access these extended diagnostics. Page 6

Communication Communication can be diagnosed using tools such as: Protocol analysers and diagnostic tools. Waveform visualisation tools such as oscilloscopes etc. Communication errors do not always produce loss of control. This is because modern fieldbus technologies are very robust to errors that can corrupt data. Page 7 Communication Quite often users are unaware that their system has communication errors because the robustness of PROFIBUS can hide these. Green light all must be ok! Only when the rate of data corruption reaches a critical threshold will the fault become visible. Page 8

Fault categorisation Operational can therefore be categorised as to their criticality: Critical Faults which prevent devices from functioning. E.g. sensor wire break, loss of device power, stuck valve, cut network cable etc. Can cause loss of production and/or unsafe situations and so must be immediately dealt with. Non-critical Do not immediately prevent devices from working. E.g. sensor drift, valve stiction, corrosion in connectors etc. Can be tolerated for a short time because the device is still functioning, albeit with reduced accuracy or performance. Page 9 Fault categorisation Installation Fix during commissioning How do we make sure all is well? System Health Check Critical Operational Fix during normal operation Production stops Rapid diagnostics and location required. Non-critical How can we detect, diagnose and locate these? Page 10

ProfiTrace2 (Procentec) ProfiTrace2 is the latest in a range of fault finding and health checking tools from Procentec. High-speed analyser for both DP and PA. Extensive triggering and filtering capability. PA probe available for PA segment connection. Decoding of all telegrams (DPV0 and DPV2). Built-in high-speed oscilloscope. DP scope shows RS485 waveform at bus interface. PA probe Ultra allows MBP waveform to be measured. Rapid overview of network health live list and bar chart Health-checking and performance statistics. Report generation for documentation. Page 11 ProfiTrace2 In addition ProfiTrace2 can be used as a Class1 and Class2 master for setting up and testing of both DP & PA devices. DP/PA Coupler required for PA devices (MBP segments) Simple set up and commissioning of cyclic data exchange Acyclic services for DVP1 DP devices and PA devices. Page 12

Fieldbus Diagnostic Module (Pepperl+Fuchs) The Fieldbus Diagnostic Module from Pepperl+Fuchs provides communications monitoring and diagnostics for PA segments. The device is available as a permanent fixture that plugs into a coupler base, or as a mobile unit that can be plugged into any PA segment. Page 13 Our Demo Setup We have a small system set up to demonstrate some of the engineering tools that are available: Siemens S7-300 PLC Pepperl+Fuchs DP/PA coupler PROFIBUS PA MBP wiring Master #1 #3 Pressure transmitter #4 #5 PROFIBUS DP RS485 wiring Temperature transmitter Level transmitter Page 14

Our Demo Setup PA Probe Ultra ProfiTrace hardware USB cable to laptop PROFIBUS DP connection (RS485) PROFIBUS PA connections (MBP) Mobile Fieldbus Diagnostics Module Page 15 FDT/DTM The FDT (Field Device Tool) specification provides a standard interface between device specific Device Type Manager (DTM) software and the User. The DTM is a software component provided by the manufacturer of an intelligent device. The DTM provides all the functionality to configure, test and diagnose the device from a laptop or PC station. DTM FDT Write PC Read Read Write Page 16

Live Demonstration