SINGLE PHASE HOUSE SERVICE METERS

Similar documents
LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

UGVCL/SP/591/11KV HT AB CABLE

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

CLAMPS CONNECTORS & EQUIPOTENTIAL RING

Cable Plug acc. to DIN EN , Form A

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Explosion proof enclosures

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

FAQs-Main switchboard design criteria

H45 LED - Direct and indirect pendant

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

R.C.C.B. s two-pole LEXIC

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SEISMIC VELOCITY TRANSDUCER T1-40

High-ohmic/high-voltage resistors

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

SURGE PROTECTIVE DEVICES

Vario-Series Accessories

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS... 4

DS 600. A contact free flux gate based current measurement sensor 600A rms

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

System 8. ü ( System 8

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RM4TG20 three-phase network control relay RM4-T - range V

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

The complete range of consumer switchboards and switchgear

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

ADM1TE 5/30A DIN rail single phase two wire energy meter

OLI. Oil level indicator

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

Agilent 87421A/87422A Power Supply

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

Specification N : NPS - 63/8. Underground Power Cable Covers

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

High-ohmic/high-voltage resistors

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI

Bulletin 150 SMC Flex Smart Motor Controller Specifications

a Nexans company Catalogue 2014

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

3/2- and 2/2-way cartridge valve type BVE

INTERNATIONAL STANDARD

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

New Media Power Socket Outlets. New Media Power Socket Outlets

TELESCOPE Motorized Lighting Suspension

AC Electric Motors best practice

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Series 8146/5-V37 and Series 8150/5-V37

James M. Pleasants Company

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Guidance for upgrading to GB (IEC : 2005, MOD)

7000 Series Buccaneer

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

INTERNATIONAL STANDARD

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

08. SEK IDC CONNECTORS

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

2 POLES - 5A LOW PROFILE TYPE

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

5235 Single Phase Credit Meter

1 POLE - 8A Medium Load Control

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

2.12. page Products for Explosion hazardous Environment

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Operating Instructions

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

TIG INVERTER INSTRUCTION MANUAL

Transformer Bushings for GIS

Data Sheet. Electro-mechanical counters Hengstler 800 series

3/2-way Solenoid Valve, direct-acting, NC or NO

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Environment-Laboratory Ambient Conditions

ADDENDUM #1(BID PACKAGE # 3)

Technical data sheet TDS0070

IMQ RULES. Contents. IMQ Rules - Product certification

Check-list for auditors. Audit visit at candidate registered laboratories

Cross-beam scanning system to detect slim objects. 100 mm in

EC DECLARATION OF CONFORMITY FOR MACHINES

Transformer oil cooler ALFA A02

Transcription:

035: 2006 CEB STANDARD SINGLE PHASE HOUSE SERVICE METERS CEYLON ELECTRICITY BOARD SRI LANKA

Specification for SINGLE PHASE HOUSE SERVICE METERS CEB Standard 035: 2006 CEYLON ELECTRICITY BOARD No. 50, Sir Chittampalam A. Gardiner Mawatha, Colombo 2. Sri Lanka Telephone: 94-1-430471, 421720 Facsimile: 94-1-430473 E-mail : cebdp@mega.lk

CONTENTS Page 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable Standards 2 5. Basic Design Features 2 6. Quality Assurance 4 7. Proof of Ability 5 8. Name Plate Markings 5 9. Tests 6 10. Warranty 7 11. Packing 8 12. Sample 8 13. Information to be supplied with the offer 8 14 Inspection and Testing 9 15 Annex 9 1

SPECIFICATION FOR SINGLE PHASE HOUSE SERVICE METERS 1.0 SCOPE This Specification covers the general requirements of design, manufacture, testing, supply and delivery of Single Phase House Service Meters. 2.0 SYSTEM PARAMETERS a) System Nominal Voltage - 230 /400 V a.c. b) System Highest Voltage (single phase) - 240 V a.c. c) System Frequency - 50 Hz d) Method of Earthing - Neutral effectively earthed at Substation e) System Fault Level - 25 ka 3.0 SERVICE CONDITIONS a) Maximum ambient temperature - 40 0 C b) Maximum relative humidity - 90% c) Annual average ambient temperature - 30 0 C d) Environmental condition - Humid tropical climate with heavily polluted atmosphere e) Highest altitude - From MSL to 2000 M above MSL f) Isokeraunic (Thunder day) level - 90 days 4.0 APPLICABLE STANDARDS The items and components supplied shall be in accordance with the latest edition of the Standard specified below and amendments thereof. However the CEB Specification shall supersede these Standards in the event there is a discrepancy. a) IEC / BSEN 62052-11:2003 - Electricity Metering Equipment (AC)-General Requirements, tests and test conditions b) IEC / BS EN 62053-11:2003 - Electricity Metering Equipment (a.c.) Particular requirements. Electromechanical meters for active energy (Class 0.5, 1 and 2) c) IEC / BS EN 60514: 1995 - Acceptance inspection of Class 2 alternating-current Watt-hour meters d) ISO/IEC : 17025:2005 - General requirements for the competence of testing and Calibration laboratories 5.0 BASIC DESIGN FEATURES The meters shall be 240 Volt, 50 Hertz, Single Phase, 2 Wire, integrating Kilo Watt-hour Meters complying with Standards stipulated in Clause 4.0 above. 5.1 The meters shall be of accuracy Class 2 and shall be suitable for use in a tropical climate and service conditions as stipulated in Clause 3.0 5.2 Power loss shall be less than 1 Watt 2

5.3 The meter base, terminal compartment, meter cover and terminal cover shall be made of non-hygroscopic non-ignitable insulating material with good surface finish. The meter cover shall be made of clear polycarbonate or transparent thermoplastic material and shall be one integral unit. The terminal covers shall be of extended type with provision to seal the meter cover and terminal cover separately. 5.4 The meter cover shall have a continuous gasket between the base and the cover (fitted in a recessed groove in the cover) to prevent entry of dust, water, insect etc. so as to achieve degree of protection not less than IP52 as per IEC 60529.Gasket shall not be detached when meter cover is removed from the base. Design of the Meter shall be such that it shall not be possible to remove the meter cover without removing the terminal cover. Fool proof seals lasting for minimum of 15 years have to be provided to the meter cover by the manufacturer. 5.5 The low load, power factor and full load adjustments shall be indelibly marked and easy access to the same shall be available. These shall be stable, sensitive and easily accessible and shall not comprise of parts, which are fragile or complicate. The adjustments devices would preferably be by means of micro screws. The rotation direction of the adjustment devices shall be clearly indicated. Full load adjustment shall be independent from low load adjustment. 5.6 The voltage and current coils shall be connected together by an easily detachable link which shall be enclosed by the meter cover and not by the terminal cover. Once detached, a sufficient clearance shall be available between terminals to prevent short-circuiting when is testing. With link detached, the voltage coil terminals shall have suitable means for independent test voltage leads to be connected to them. 5.7 The voltage coil shall be fully encapsulated to prevent ingress of moisture and marked with its rated voltage. The method of encapsulation shall be described in detail. The impulse (1.2/ 50µs) and the power frequency withstand voltages of the meter shall not be less than 10kV peak and 2kV rms respectively. The voltage coil shall be designed to withstand the above high voltages without open circuiting. 5.8 The rotor upper bearings shall be guided by stainless steel pin with a non-lubricated bearing bush mounted to the spindle. Lower bearing shall be magnetic suspension type 5.9 The upper surface of the rotor disc shall have black coloured markings dividing the circumference into 200 divisions. The markings at each 1/100th of the circumference shall be longer than those between. Markings at each 1/10th of the circumference shall be still longer and shall be numbered from 0 to 9. These markings shall be visible through the name plate window to facilitate manual calibration. 5.10 Rotor disc shall be of light weight electrolytic Aluminium metal die-cast to the spindle. 5.11 Breaking magnet shall be positioned to the frame rigidly to prevent any movement. The magnet shall be temperature compensated with respect to wide range of temperatures and shall have high resistance to de-magnetization and low temperature coefficient. The details of the method of temperature compensation shall be fully described 3

5.12 The edge of the rotor nearest an observer viewing a meter from the front shall move from left to right for positive registration. The direction of rotation shall be marked clearly by a visible arrow. The edge of the rotor disc shall carry an easily visible mark with a width of between 1/20 and 1/30 of the circumference of the disc to facilitate testing. This mark shall either start from the marking for number 0 or end at the marking for number 0 stated in clause 5.9 above. 5.13 With no current in the current circuit, the rotor shall not make one complete revolution at any voltage between 80% and 110% of the rated voltage. The meters shall be fitted with antireverse device. 5.14 All terminals, screws and nuts shall be nickel plated brass to provide high resistance to corrosion. 5.15 The registers shall be of large jumping figure cyclometer type. The dimensions of figures shall not be less than 6mm (Height) and 4mm (Width). There shall be six number drums in the register and numbering shall be done as specified in IEC/BS EN 62053. The limits of variation in percentage error due to mechanical load of the register shall not be more than one (1). 5.16 The meter constant shall not be more than thousand revolutions per kwh and the meter constant shall be indelibly marked on the body of the register. 5.17 All components (except terminals) shall be mounted on single rigid Aluminium die-cast frame to achieve long-term calibration stability. The spacing of meter fixing holes, terminal arrangement, and the terminal bore sizes and the wiring arrangement shall be as indicated in the Drawing No. DS&S /2001/35 (Annex A). The terminals and screws shall have two M6 screws for effectively clamping the cable. 6.0 QUALITY ASSURANCE 6.1 The manufacturer shall possess ISO 9001: 2000 Quality Assurance Certification for the design, manufacture and testing of Single Phase kwh meters. In the event the meters are manufactured in a plant under the licence of the manufacturer, the manufacturing plant shall possess ISO 9001: 2000 Quality Assurance Certificate for manufacturing and testing of Single Phase kwh Meters. The Bidder shall furnish a copy of the ISO Certificate certified as true copy of the original from the manufacturers, along with the offer. If the following items are purchased from other manufacturers, they shall have ISO 9001 Quality Assurance Certification for the manufacture of same for the plant where the manufacture is done. The Bidder shall furnish copies of the ISO Certificates certified as true copies of the originals from the manufacturers, along with the offer i) Permanent magnet ii) Magnetic bearing iii) Register 6.2 Each Meter to be tested and calibrated at a meter testing laboratory having ISO/IEC: 17025:2005 and properly sealed thereafter. 6.3 The proof documents with regard to the accreditation for the above facility in accordance with ISO/IEC:17025:2005 shall be submitted along with the tender. 4

7.0 PROOF OF ABILITY 7.1 Manufacturing Experience. 7.1.1 The Manufacturer shall have at least twenty years (20) of experience in the manufacture of House Service Meters. Documentary proof for the manufacturing experience shall be provided. In addition, sufficient documentary evidence such as name of purchaser, year of sale, quantity sold, purchase orders, model numbers of the meter sold etc. for the last 15 years shall be furnished with the offer. 7.1.2 The meter manufacturer shall guarantee that the offered meters will operate within the stipulated error limits for a period of 15 years without re-calibration. 7.2 SUPPLIMETARY QUALIFICATIONS The following supplementary qualifications will be considered in the evaluation of bids. Hence if the equipment offered meets any one or more of the following criteria the bidder shall further qualify for the selection. 7.2.1 Certificates for Service life Ofgem certification or other certification issued by an electricity regulating institution certifying a minimum service life of 15 years, (certified copies of the certificates shall be attached to prove this.) 7.2.2 Performance Reports/Certificates 7.2.2.1 Bidders may furnish performance reports/certificates obtained from electricity supply authorities outside the country of manufacture to whom the bidder has supplied meters of similar type/model during the last ten years. 7.2.2.2 The above certificates/reports shall indicate the name of purchaser, model of the meter, year of purchase, quantity purchased, and the performance of the meters based on the field experience or field studies. 7.2.2.3 The purchaser reserves the right to communicate with electricity supply authorities who has issued performance certificates with regard to the performance of the meters and the authenticity of the performance certificate issued by them. The contact person and contact details of those utilities such as FAX/Telephone numbers etc shall be furnished by the Bidder in his offer. 8.0 Nameplate Markings 8.1 The Nameplate of Meters shall bear all the information stipulated in clause 7.1 of IEC/ BS EN 62053. The marking shall be indelible, distinct and readable from outside the meter. 8.2 The words "Property of the Ceylon Electricity Board" with a mark W-15Y shall be engraved on the nameplate. 8.3. A serial number (which will be indicated at the time of placing an order) shall also be engraved on the nameplate. 5

9.0 Tests 9.1 Routine Tests The following routine tests as per IEC/ BS EN 62053 shall be carried out on all the meters in a laboratory as per clause 6.2. a) 400% basic current, reference voltage and at unity power factor. b) 400% basic current, reference voltage and at 0.5 lagging power factor. c) 200% basic current, reference voltage and at unity power factor. d) 200% basic current, reference voltage and at0.5 lagging power factor. e) 5% basic current, reference voltage and at unity power factor f) Register test g) Starting current test h) Running with no load test i) Verifying minimum range of further adjustment A certificate on the above testing and calibration for each meter should also be submitted along with the meter. 9.2 Type Test Certificates Type test reports for the test listed in below shall be obtained from one of the following Internationally Recognized Institutions / National Meteorological Laboratories shall be submitted with the offer..each page of the test report shall be certified and stamped by the Testing Authority. CEB shall request Original Type Test Reports/Test Certificates before the issue of award letter for perusal if considered necessary. i) United Kingdom - ASTA Certification Services (ASTA) or National Metrological Laboratory in UK, accredited to Western European Legal Metrology Corporation (WELMEC). ii) Italy - Centro Electtrotecnico Sperimentale Italiano S.P.A. (CESI) or National Metrological Laboratory in Italy accredited to Western European Legal Metrology Corporation (WELMEC). iii) France - Ensemble Des Stations D Essais a Grande Puissance Francaises (ESEF) or National Metrological Laboratory in France accredited to Western European Legal Metrology Corporation (WELMEC) iv) Netherlands B.V. KEMA (KEMA) or National Metrological Laboratory in Netherlands accredited to Western European Legal Metrology Corporation (WELMEC) v) Japan National Metrological Laboratory in Japan accredited to National Laboratory Accreditation System in Japan vi) USA National Metrological Laboratory accredited to American Association for Laboratory Accreditation. vii) Australia National Metrological Laboratory accredited to National Association of Testing Authority (NATA) viii) India Central Power Research Institute (CPRI) 6

9.3 Type Tests The Type Tests shall be carried out at a reference voltage 240 volts and at a reference frequency of 50 hz. a) Mechanical Requirements as per IEC/ BS EN 62053 and as per Clause 5.0 of this standard. i ) Mechanical Requirements and tests as per Clause 5 of IEC / BSEN 62052-11:2003 for Electricity Metering Equipment (AC)-General Requirements, tests and tests conditions ii) Terminal block Material test as per ISO 75 iii) Non-flammability Glow wire test as per IEC 60695-2-10 b) Electrical Requirements as per IEC / BS EN 62053 and as per Clause 5.0 of this Standard. i) Power Losses 1. Voltage Circuits 2. Current Circuits ii) iii) Heating Di-electric properties 1. Impulse withstand voltage test - as per Clause 5.6 of this Specification. 2. Power frequency withstand Voltage tests.- - do - 3. Insulation resistance c) Accuracy ( including change of error due to variation of voltage, ambient temperature, frequency, level, stray field etc and Mechanical load on register as per Clause 5.11 of this Standard. d) Starting and running no-load e) Adjustment f) Mean temperature coefficient g) Effect of high temperature Test as per Clause 9.4 of this Standard The test certificates shall clearly identify the kwh meter tested, showing the following; i) Manufacturer's identity, ii) Model / type number, iii) Type of register, iv) Type of rotor bearing, break magnet and other basic parameters, 10 Warranty Manufacturer shall provide 15 year warranty from the date of FOB dispatch of the meters to the purchaser. Manufacturer should forward the duly signed Warranty Certificate together with the letter of acceptance of the tender award. The format of the Warranty Certificate is given in Annex C. When the meters become defective within first two years of warranty they shall be replaced free of charge. The meters become defective after two years during the warranty period shall be repaired or replaced free of charge. CEB shall not remove the meter cover for any purpose such that CEB has the right to claim under warranty in the event of any defect in the meter. Manufacturer shall honour the conditions in the warranty certificate accordingly. 7

11 Packing Each meter shall be individually packed in a cardboard box using bubble wrapping to prevent damage during transport and handling. A maximum of ten meters shall be packed in cardboard boxes and the boxes shall indicate the Type, Rating and Serial No. of the item. All packing material shall be of bio-degradable type 12.0 SAMPLE Two samples of each rating with manufacturer s seals shall be furnished with the offer. Unsealed sample meters shall not be accepted. 13.0 INFORMATION TO BE SUPPLIED WITH THE OFFER 13.1 The following shall be furnished with the offer. a) Catalogues describing the meter and indicating the type and model number. b) Literature describing the operational features of the meter. c) Constructional features, materials used for components and relevant technical literature for the following shall be furnished i) Permanent magnet ii) Magnetic bearing iii) Register iv) Voltage coil d) Full details of the method of encapsulation of voltage coil and winding details of current and voltage coils eg. Type of frame used, Insulation of wires, etc. e) Full details of temperature compensation methods used in magnets, giving details of thermal compensating device, temperature ranges etc. f) Construction details of upper and lower bearings. g) Complete dimensional drawing. h) List of Electricity Supply Authorities who purchased similar meters during last 20 years. Details of such purchases including names of purchaser, year of sale, quantity sold, purchase orders/tender Nos. and model numbers of the meters sold etc. shall also be furnished. i) Manufacturing Experience stipulated in clause 7.1. Documents shall be furnished to prove the manufacturing experience. j) The details of the information that will be marked on the Name Plate of the Meter. k) Completed Schedule of Particulars (ANNEX - B). l) Quality Assurance Certification conforms to ISO 9001 as per Clause 6.0. m) Proposed format of agreement shall be submitted along with the offer 13.2 Offer shall be rejected if the Bidder fails to furnish the complete particulars conforming to clauses 6.1, 6.3, 7.1, 9.2 and 10 and Sample Meters as stipulated in clause 12.0. 8

14.0 INSPECTION AND TESTING 14.1 Inspection Selected bidder shall make necessary arrangements for inspection of each consignment of meters by an Engineer appointed by the purchaser and to carry the tests as stipulated in Clause 10.2 in his presence to verify the accuracy and performance of the meters offered is as per this specification. If the meters fail to meet the requirements of this specification, then the total quantity under the tender shall be rejected. Routine Test reports (as per Clause 9.1) of the meters offered for inspection shall also be furnished for the observation of the inspector. 14.2 Acceptance / Sample Tests a) Clearance and creepage distance b) Power loss on i) Voltage circuit ii) Current circuit c) Apparent power loss d) Heating e) Dielectric qualities f) A C Voltage g) Flammability h) Variation due to self-heating i) Percentage error limits 14.3 Sampling method The sampling method shall be as stipulated in IEC/ BS EN 60514. 15.0 ANNEX A - Drawing No. DS&S /2001/035 B - Schedule of Particulars to be filled by the Bidder C - Format for Warranty 9

ANNEX - A 10

ANNEX - B SCHEDULE OF GUARANTEED TECHNICAL PARTICULARS (This schedule shall be duly filled by the Manufacturer) 1) Name of manufacturer and country of origin - 5/20 10/40 20/80 2) Type and Catalogue number/ Model number - 3) Accuracy Class - 4) Applicable Standards - 5) Reference / Rated i) Voltage V - ii) Frequency Hz - 6) Rated maximum Current I max A - 7) Basic Current I b A - 8) Starting Current of Meter - % of rated current - (at unity power factor) 9) Creeping voltage % of rated voltage - 10) Meter constant Rev/kWh - 11) Basic Speed Rev./min - 12) Basic Torque gm/cm - 13) Rated Maximum Load Speed at unity PF Rev/min - 14) Rated maximum load torque gm/cm - 15) Mean temperature coefficient i) From 0.1I b To I max at unity PF %/ o C - ii) From 0.1I b To I max at 0.5 lagging %/ o C - 16) Break magnet system i) Name of the manufacturer - ii) Type (two pole/four pole/six pole/eight pole) - iii) How long the type of break magnet in the offered meter has been in use Years - v) Whether the ISO 9001 certificates are furnished Yes/No - (as per Clause 6.0) 11

17) Rotor Bearings i) Name of manufacturer - ii) Type ( Jewel / magnetic) - iii) How long the type of rotor bearing in the offered meter has been in use Years - vi) Whether the ISO 9001 certificate furnished Yes/No - 18) Rotor weight grams - 19) Energy Register i) Name of manufacturer - ii) Type (Dial type, Cyclometer/Jumping cyclometer) - iii) How long the type of register in the offered meter has been in use Years - iv) No. of digits - v) Digit size mm X mm - vi) Whether the ISO 9001 certificate furnished Yes/No - 20) Material of n) Meter base - ii) Terminal base - iii) Meter cover - iv) Terminal cover - v) Cover screws and the type - 21) Whether the gasket is i) provided between the meter base & cover Yes/No - ii) continuous Yes/No - iii) fitted in a recessed groove in the cover Yes/No - 22) Material of gasket - 23) Applicable IP Code IP - (Degrees of protection) 24) Terminal - i) Material - ii) Bore diameter - iii) Bore length - iv) Number of screws provided - v) Size of screws - vi) Material of screws - 25) Material of the meter frame - Whether the meter frame is single rigid type Yes/No - 26) Whether the meter is fully tropicalised Yes/No - 27) Number of holes provided for mounting the meter - 12

28) Vertical distance between top fixing holes and centre line of bottom fixing holes mm - 29) Distance between centres of bottom fixing holes and centre line of meter mm - 30) Whether the type test certificates as per Clause 9.2 and 9.3 are furnished Yes/No - 31) Limit of Errors i) 0.05 I b at unity PF - ii) from 0.1 I b to I max at unity PF - iii) 0.1 I b 0.5 lagging - 0.8 leading - iv) from 0.2 I b to I max 0.5 lagging - 0.8 leading - 32) Insulation Level i) Power frequency withstand voltage for 1 min. kv - ii) Lightning impulse withstand voltage (Peak) KV - iii) Insulation resistance Mega ohms at 500V DC - 33) Power Losses i) Voltage circuit at reference voltage a) Active W - b) Apparent VA - ii) Current circuits at basic current (Apparent) VA - 34) Temperature rise i) Winding ii) External surfaces of the case o C - o C - 35) Whether the sample tests as per clause 14.2 will be carried out by the Bidder during inspection Yes/No - If Yes, Indicate the place of testing - 36) Number of meters (similar type/model) sold up to now Nos. - 37) How long the model offered has been under production Yes/No - 38) Single phase meter manufacturing capacity per month Nos. - 39) Single phase meter calibration facility Number of single phase meter calibration Benched available at the laboratory Nos. - Number of single phase meters that could be calibrated by each bench/per day Nos. - 13

40) Testing Laboratory is complied to Yes/No ISO / IEC : 17025:2005-41) Whether the document to prove the manufacturing experience as per Clause 7.1.1 is furnished Yes/No - 42) Whether the Quality Assurance Certification conforming to ISO 9001 for the manufacture of the following are furnished i) kwh Meter Yes/No - ii) Permanent magnet Yes/No - iii) Magnetic bearing Yes/No - iv) Register Yes/No - 43) Certification period of the meter offered (as per Clause 7.1.2) Years - Whether documentary evidence furnished to prove this Yes/No - 44) Recommended re- calibration interval Years - 45) Guaranteed Life Span of the offered meter Years - 46) Type of packing material - 47) Whether the packing material is bio - degradable yes/no - I/We certify that the above data are true and correct. ----------------------------------------------------------------------------------------- SEAL AND SIGNATURE OF THE BIDDER / MANUFACTURER 14

ANNEX C Warranty Certificate General Manager, Ceylon Electricity Board, 50, Sir Chittampalam A Gardiner Mawatha, Colombo 2, Sri Lanka... (Hereinafter called the Manufacturer) shall make good by repair or, at our option by replacement, defects which, under proper use and in accordance with any instructions issued by us, as appeared in the contract of our supply or manufacture within a period of not more than One Hundred and eighty (180) months after the original FOB dispatch date (When the meters become defective within first two years of warranty they shall be replaced free of charge. The meters become defective after two years during the warranty period shall be repaired or replaced free of charge. ) provided that:- a) All meters having Serial Nos. From. To. supplied by....manufacturer for the CEB Tender No is handled, installed and commissioned in a manner as agreed to by the Manufacturer and the Ceylon Electricity Board and operated at the designed normal operating conditions at all times for which it was intended. b) We are notified of the alleged defect first coming to the purchaser s notice and within the warranty period. c) The defective meter(s) is/are returned promptly to our Agent in Sri Lanka free of charge if we so require and we shall return new or repaired meter(s) free of charge to the original contract delivery point unless otherwise arranged within 03 months period from notification. d) Any unauthorized handling; repairs or alterations to the meter(s) shall invalidate this warranty. e) If it is found that the meter has been mishandled, neglected and / or modified in any way during the storage period, the warranty in general will become null and void. The warranty applied only to goods and services carried out by the Manufacturer or with the Manufacturer approval. Yours faithfully, (Manufacturer) 15

Date: 16