DIGITAL RADIOGRAPHY Fully-Integrated DR Systems and Upgrade SOLUTIONS COST EFFECTIVE High Quality Digital Radiography Wide Screen Control with Touch-Technology
DR Acquisition Console Software DRive is a digital imaging DR hardware & software solution designed for General Radiography of anatomy, using a unique image processing system and proprietary flat panel detector technology. It is intended to replace film and/or CR cassette based radiographic systems for all general purpose diagnostic procedures. DRive offers a flat panel digital radiography solution of a 17" x 17" Fixed detector, a 14" x 17" Tethered (Portable) detector and/or a 14" x 17" Wireless detector with either Gadolinium Oxysulfide or Cesium Iodide scintillator. DRive ensures superior image quality for today s high standards in precise diagnosis with spatial resolution of 3.5 lp/mm. DRive DR Acquisition Console Software Patient Registration: Manually or DICOM Modality Worklist Patient size selection: Pediatric, Small, Medium, Large Adult Image Acquisition + QC (Brightness/contrast, Flip, Rotate, Zoom, Annotations, Measurements, Pan, Window/Level, Mag, Crop, Invert, Line measurement, Angle Measurement, Text, Arrow, L&R Markers, Clockwise Rotation, Counter-Clockwise Rotation, Cobb s Angle Measurement, Pre-defined Texts-Labels) Image Preview in 3 Seconds DICOM Store to PACS DICOM Storage Commitment MPPS (Modality Performed Procedure Step) DICOM Print to DICOM Printer or Print to Printer for paper printer Export images formatted as.jpg,.tiff,.bmp, and DICOM (with or without Viewer) to CD or other media Archive to CD/DVD Archive to removable drive Hard disk capacity warning Scheduled periodic back-up warning Preconfigured with default anatomical exam tree, image processing parameters and generator technique Auto-Crop with Black Surround Delete Images and/or studies - scheduled periodic deletion Stitching Manually and Auto (Scoliosis & Leg-Length Imaging) Remote access via Team Viewer Exposure Handswitch DR Trigger Mode: (using generator interface cable) Generator receives signal that detector is prepared to capture X-rays AED Mode Automatic Exposure Detection: The detector detects initation of X-rays without any connection to the X-ray generator, and then acquires image according to exposure time (no need to connect to generator) Exposure Index Deviation Index Repeat- Reject tracking software (per log-in & anatomical view) Dose Recording - (Requires Optional DAP Meter) Grid Line Subtraction Software Virtual Keyboard for use with TOUCH SCREEN MONITOR Speed with Precision A preview image is displayed immediately after X-ray exposure, allowing for prompt image confirmation, fast network distribution, and quick patient throughput. DICOM 3.0 compatibility provides patient registration with modality worklist and image data transfer to any DICOM destination (Printer or PACS) for efficient data management, archiving and remote image viewing. Workflow efficiency means less wait time for patients, as well as higher patient throughput. Provides consistent image quality at a dramatically reduced dose. PACS Server & DICOM Viewer Software (Computer not included - Software Only) DICOM PACS Server Software Archives patient studies/images in DICOM format as sent from the Acquisition Console DICOM Viewer Software Query and Retrieve of patient studies/images from Server to remote viewing workstations Five 5 Client Viewing Licenses Export feature with images formatted as.jpg,.tiff,.bmp, and DICOM (with Viewer) to CD or other media REPEAT-REJECT FEATURE Reject an image & select a reject reason from the drop down menu
HIGH QUALITY DIGITAL RADIOGRAPHY Benefit from the advantages of rapid DR workflow Configure Your Drive Console To Your Specialty (Medical, Chiropractic or Veterinary) With Customizable Practice-Specific Anatomical Regions *Veterinary DICOM Attributes: Species (Canine, Feline, Equine, Ovine, Porcine, Bovine, Caprine), Breed, Sex Neutered Status, Breed Codes, Breed Registration Codes, Responsible Person EXPOSURE INDEX FEATURE The Preview image display will show the EXPOSURE INDEX per the image. In conjunction with the EXPOSURE INDEX, the display includes a color coded DEVIATION INDEX proportional to the pre-programmed anatomy - specific target index. GREEN will reflect a correct exposure range ORANGE will indicate moderate under/over adequate exposure RED will indicate over/under exposure
YOUR CHOICE OF DETECTOR COMBINATIONS DRive DETECTOR COMBINATIONS Offered with either Gadolinium Oxysulfide or Cesium Iodide scintillator. Available as a single panel detector or dual panel detector combinations (Fixed, Tethered and/or Wireless). Fixed 43 x 43 cm (17" x 17") Detector (GOS or CsI) Large imaging area 43 cm x 43 cm (17" x 17") Capture views in one shot without rotating the detector Fixed detector in the Table or Wallstand Tethered 35 x 43 cm (14" x 17") Detector (GOS or CsI) The detector fits all existing bucky trays as it is the same size as a film cassette or CR Image Plate Easy upgrade to DR without any change in conventional X-ray Imaging area 35 cm x 43 cm (14" x 17") Easy to carry with an attachable & removable handle Wireless 35 x 43 cm (14" x 17") Detector (GOS or CsI) The detector fits all existing bucky trays as it is the same size as a film cassette or CR Image Plate Image acquired and transmitted through Wi-Fi in seconds. The battery charger system can recharge up to 3 batteries at the same time within 2 hours for full charge. Wireless detector has a built-in Access Point (AP) Carrying Handle Can be removed at installation to fit into existing cassette trays, if needed Battery Charger Wireless Communication Standard Communication interface through WLAN (IEEE 802.11a/b/g/n) Dual bandwidth (2.4GHz and 5GHz) with two antennas Router STITCHING SOFTWARE The image stitching is standard with the DRive Software. Below is a screen capture which involves this process. As with any stitching, images must first be acquired with stitching in mind. The stitched image becomes a stand-alone composite DICOM image to which measurements can be applied. Image - 1 72" SID OPTIONAL (For Table or WallStand) ROTATING RECEPTOR TRAY One-handed manual rotation Lengthwise/ Crosswise in swivel based tray design Tray locks provide for safe placement/ removal of receptor Locking tab secures the receptor within the tray OVERLAP BB Tube Horizontal Detent Image - 2 Remote Service Support Software TEAM-Viewer Remote Access Software Included (allows for WEB-Based Remote dial-up support) Download files and maintenance instructions. Transfers files between the workstation and a service representative
Retro-Fit DR Upgrade Packages A truly unique offering and productivity enhancement is Generator integration with Quantum Medical Imaging Radiographic Systems. With fully integrated Quantum DRive DR systems, the generator is controlled via the DR console. This frees space within the technologist control booth. Rather than having to set techniques on a separate generator control and manage DR acquisition on another separate user interface, all is integrated onto one DR User Console. This includes preprogrammed exposure techniques and patient size modifiers for each view (procedure step) selected on the DR console. X-Ray Generator + DR Acquisition = INTEGRATION DR UPGRADE PACKAGES Extend The Life Of Your Existing Rad Room Investment Upgrade to DR from Existing Installed OEM Rad Room With unique AED Mode Automatic Exposure Detection: The detector detects initation of x-rays without any connection to the x-ray generator, and then acquires image according to exposure time (no need to connect to generator) Upgrade to DR with Generator Integration to Any Existing Installed Quantum Rad Room Includes Exposure Handswitch DR Trigger Mode: (using generator interface cable) Generator receives signal that detector is prepared to capture x-rays Benefit from the advantages of rapid DR workflow Easy to use with your existing X-ray system. Wireless Tethered Fixed
DRive DR Detector Specifications DRive Specifications DR-1417 (Wireless) DR-1417 (Tethered) DR-1717 (Fixed) Purpose General Radiography Feild Of View 14"x17" 14"x17" 17"x17" Scintillator CsI (Cesium Iodide) or Gadox (Gadolinium Oxysulfide) Pixel Pitch 140 Microns Grayscale 14 bit, 16,384 grayscale Spatial Resolution Min. 3.5 line pair/mm (Nyquist Resolution) Image Matrix Size 2560 x 3072 pixels (7.8 Mega Pixels) 2560 x 3072 pixels (7.8 Mega Pixels) 3072 x 3072 pixels (9 Mega Pixels) Image Acquisition & Transfer Time 3 seconds Technology Flat Panel Detector a-si TFT Cooling Network Interface Power Supply Ambient Air Cooling Tether Interface (1000 Base-T) 7.4V 4000mAh Lithium Ion Battery 16 bit Digital Output Ethernet (1000 Base-T) DC+24V, 0.5 A 16 bit Digital Output Ethernet (1000 Base-T) DC+24V, 0.8 A Weight 6.39 lbs. (2.9kg) 5.94 lbs. (2.7kg) 24.2 lbs. (11kg) Dimensions 384 x 460 x 15mm 384 x 460 x 15mm 470 x 470 x 39mm Panel Warranty 3-Year Warranty (against manufacturing defects) Wireless Standard IEEE 802.11a/b/g/n (2.4GHz/5GHz) - Dual Bandwith (Specifications subject to change without notice) N/A N/A Computer Workstation - (3 Year Warranty on PC and Monitor) Windows 7 Professional 64bit Intel Core i5 2400 2.8 Ghz Processor 4GB DDR3 memory Two hard disks (2 TB) 1TB x 2 Level 1 RAID Image Storage Capacity = 100,000 Images NIC-Broadcom Ethernet card DVD writer Monitor Features: 23 Wide Touch-Screen Display Full HD Resolution 1920 x 1080 Pixels (2MP) Unique Monitor Stand tilts up to 60 degrees to suit individual viewing needs (Optional Monitor Wall Mount Kit) 2015 Quantum Medical Imaging, LLC p/n: QMI-DRive (4/15) DRive Options: DRive-TRAY: Rotating Tray with Receptor Housing, for use with 14" x 17" Tethered DRive Detector Rotating Tray and Receptor Housing, for Landscape/Portrait positioning of 14" x 17" Tethered DRive Detector Allows for one-handed manual rotation of the portable digital detector within the tray *(may not fit into all existing tables and/or wall stands) Panel Three Year Warranty Coverage: Covers against mechanical failure and malfunction of the products caused by a deficient design, factory defect or faulty workmanship. Warranty shall be void if: Damages are caused by owner abuse, malicious destruction or accidental drop. Quantum Medical Imaging, LLC Division of Carestream 2002 Orville Drive North Ronkonkoma, NY 11779 USA Tel: (631) 567-5800 Fax: (631) 567-5074 www.quantummedical.net