PRODUCT/TEST MANUAL 1B220K1 SINGLE SHOT AUTO-RECLOSE. Order Number Serial Number. Issue Date Summary of changes A 5/10/00 Initial issue.

Similar documents
Sentron Series Circuit Breakers

Solid State Timers Type F

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

conventional system operation

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Fire Alarm Control Panel. Family. Operating Manual

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

PUSH BUTTON START INSTALLATION MANUAL

Data Sheet. Electro-mechanical counters Hengstler 800 series

DC LOAD TESTING Gian Trento June 18 th, 2004

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Product Guide. Low voltage grounding system. Answers for industry.

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Current and voltage measuring relays

Type SA-1 Generator Differential Relay

SKR - industry relay

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

PAC1 Door Access Controller

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

13 SERIES. Electronic step relays A

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

38 Series - Relay interface modules A

Tamura Closed Loop Hall Effect Current Sensors

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Fundamentals of Power

38 Series - Relay interface modules A

INSTALLATION & SERVICE MANUAL. Display Panel

T Substation Maintenance and Commissioning Test Equipment

Safety technique. Emergency stop module BO 5988 safemaster

ECE 586b Course Project Report. Auto-Reclosing

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Safety automation solutions

Chapter 11. Inductors ISU EE. C.Y. Lee

Nokeval. User's Manual Models 301 / 302 / 305

UNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT ME269 ELECTROMECHANICAL DEVICES AND POWER PROCESSING.

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The

Telefon (+45) Telefax (+45) Installation and operating manual

Trip circuit supervision relay. Type RXTCS

RCDC1 Radio Controlled Device Controller- 1 Channel

Speed Control Relays SX2

Low Cost Automatic Transmission Line Sectionalizing

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

210E - 210ECL ECL ECL RMS Signal Monitor. Operations Manual

Auxiliary Relay. Type P8n, PQ8n, PN8n

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

AUTODIALLER / QUICKDIALLER - SA132

Allen-Bradley/Rockwell

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Control Devices Catalogue. Control Devices. Preferred and Standard Products

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

FREJA 300 Relay Testing System

MSL1000 Monitored Serial Link Interface Manual V1.01

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Pilot-wire differential relay for lines with two or more terminals

TS510 & TS500. Installation & User Guide. Compatible Equipment

1.44 kw Programmable DC Power Supplies XLN Series

INTRODUCTION TO SYNCHRONIZING AUTOMATIC SYNCHRONIZING CONSIDERATIONS AND APPLICATIONS

Protect your home and family with Advanced Technology from Cutler-Hammer

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Servo Info and Centering

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

80 Series - Modular timers 16 A. Features

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Technical Data. back-up time in minutes 100% load % load

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

GLOLAB Two Wire Stepper Motor Positioner

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Generator Differential Relay Electrical Apparatus

Quick Connect. quick - simple - efficient.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

S&C BankGuard PLUS Control

Transcription:

Sheet 1 of 6 PRODUCT/TEST MANUAL 1B220K1 SINGLE SHOT AUTO-RECLOSE Order Number Serial Number Issue Date Summary of changes A 5/10/00 Initial issue. Due to RMS continuous product improvement policy this information is subject to change without notice. This document is uncontrolled and subject to copyright. Author Checked & Registered.pdf file created Released ERL MW MW

Sheet 2 of 6 1. BROAD DESCRIPTION The 1B220 relays are single shot adjustable automatic reclosing relays designed to initiate an automatic reclosing attempt of a circuit breaker following interruption of supply due to a fault in the system. The auto-reclose function may be initiated by either a series or a shunt arrangement as selected. The dead time between initiation of the 1B220 and the output of the reclose signal may be selected between 0.5 and 10 seconds. At the end of the set time period a two second reclose pulse commences after which a 5 to 100 second lockout timer is enabled. If at the end of the lockout period the circuit breaker has not re-opened the 1B220 will reset to provide another reclose sequence on the next fault. The timing and logic functions are achieved using solid state circuitry driving electromechanical relays. Initiation of the relay is achieved by applying a current (series initiate) or a voltage (shunt initiate) to a double wound relay (start relay). This relay operates and remains operated via it own contact until the auxiliary supply voltage is removed by the protection. The instantaneous protection may be inhibited by a switch on the front panel. 2. SPECIFICATIONS Initiate relay (double wound) Series initiate Current 1.2A Pulse Length >40mS Resistance <0.05 Ohms Shunt initiate Voltage 125 Vdc Tolerance + 15% to - 25% Pulse length > 40 ms Auxiliary supply Stand by Burden CB Auxiliary contact Requirement 125 Volts DC Zero 1 Normally closed (when tripped), voltage free contact Time ranges Reclose Lockout 0.5 to 10 seconds 5 to 100 seconds Timing Accuracy +/- 2 % of setting +/- 5 % of maximum setting Inhibit Instantaneous protection Instantaneous /Time delayed lockout Operation indicators Counter Selectable Switch selection LED "reclose" LED "lockout" 7 digit non resettable

Sheet 3 of 6 SPECIFICATIONS (Cont.) Output Contact Ratings Lockout Contacts Alarm Contact Make and Carry Continuously Make and Carry of 0.5 Second AC Break Capacity Reclose Contact Make and Carry Continuously 1700 VA AC resistive with maxima of 380 Volt and 8 Amp 1700 VA DC resistive with maxima of 250 Volt and 8 Amp AC Break Capacity 1700 VA AC resistive with maxima of 380 Volt and 8 Amp 3000 VA AC resistive with maxima of 660 Volt and 12 Amp 3000 VA DC resistive with maxima of 660 Volt and 12 Amp 7500 VA AC resistive with maxima of 660 Volt and 30 Amp 7500 VA DC resistive with maxima of 660 Volt and 30 amp 3000 VA AC resistive with maxima of 660 Volt and 12 Amp With magnetic blowout & arcing horns Break 2 Amps @ 250 VDC L/R=50 ms 10 times @ 30 second intervals 3. TEST EQUIPMENT REQUIRED DC Supply AC Current Supply AC Ammeter Electronic timer Oscilloscope High Voltage Test Equipment. Dummy CB or similar 4. ASSOCIATED DRAWINGS 151-220-101 Wiring Diagram 660-326-201 PCB circuit diagram 660-326-301 PCB Loading 5. HIGH VOLTAGE TESTING a) Apply 2KV RMS. between the terminal groups as listed in Group1 & Group 2 below for 1 minute. b) Apply three 5KV 1/50usec pulses of each polarity as listed in A & B below. Group 1 Group 2 1,3,5,7,9,11,15,16,17,19 22,24,26,28 + E 1,3,5,7,15,16,26,28 9,11,17,19,22,24+ E 1,3,5,7,9,11,22,24 15,16,17,19,26,28 + E

Sheet 4 of 6 6. CALIBRATION & TEST PROCEDURE 6.1 Initiation a) Apply the auxiliary supply to terminals 1 & 5 with 1 being positive, ensure the "dummy" CB auxiliary contact is closed (CB in tripped position) b) Apply a current pulse of 1.2 Amps and a pulse length of >40 ms to the series initiate input (terms 15 & 16). RL1 should pick up and hold itself operated via contact RL1-1. c) Remove & reapply the auxiliary voltage to reset the relay with term 15 as positive. d) Apply a voltage pulse of 75% nominal volts and a pulse length >40 ms to the shunt initiate input (terms 3 & 5). RL1 should pick up and hold itself operated via contact RL1-1. e) Reapply the current pulse and make sure that the relay does not drop out. This tests for correct coil polarity. 6.2 Reclose timer Calibration. a) Set front panel switches to Auto reset and Dead line b) Select divide ratio of MC14541 to 1024 by setting pin 12 (link B)to zero volts and pin 13 (link C) to positive 10 volts. c) Connect a device for measuring period to TP01-C and ignoring actual values set the ratio of minimum and maximum dial setting to 20 : 1 by adjusting R16. d) Set "reclose" control fully clockwise and select C7 & C8 combination to achieve a period of 19.5 ms. e) Check the period at minimum setting this should be 0.98 ms and maximum setting 19.5 ms. f) Record results Minimum Maximum Nominal Actual Unit 0.0 1.0 0.5 s 3.5 4.5 4.0 s 6.5 7.5 7.0 s 9.5 10.5 10.0 s 6.3 Two Second Pulse Connect the oscilloscope to TP01-D and TP01-I and adjust R23 for a two second pulse at this point. ie 2 seconds from when TP01-D goes low and when TP01-I goes high. Minimum Maximum Nominal Actual Unit 1.9 2.1 2.0 s 6.4 Calibration of the Reclaim Timer a) Select divide ratio of MC14541 to 8192 by setting pin 12 (link F)to zero volts and pin 13 (link H) to zero volts. b) Connect a device for measuring period to TP01-G and ignoring actual values set the ratio of minimum and maximum dial setting to 20 : 1 by adjusting R20.

Sheet 5 of 6 6. CALIBRATION & TEST PROCEDURE (Cont.) 6.4 Calibration of the Reclaim Timer (Cont.) c) Set "reclaim" control fully clockwise and select C12 & C13 combination to achieve a period of 24.42 ms. d) Check the period at minimum setting this should be 1.221 ms and maximum setting 24.42 ms. e) Record results Minimum Maximum Nominal Actual Unit 0 10 5 s 35 45 40 s 65 75 70 s 95 105 100 s 7. GENERAL & FUNCTIONAL a) Set switches to Auto reset and Dead line and apply nominal supply voltages. Make sure the "dummy" CB is in the tripped position indicating a fault condition. b) Apply an initiate pulse (either current or volts), RL1 should operate and hold in via its RL1-1 contact. The reclose timer will commence to time out after application of the initiate pulse. c) At the end of the time setting of the reclose timer, RL2 operates and will remain operated for 2 seconds. The "reclose "LED on the front panel will be illuminated during this time. d) When the "dummy CB" has re-closed the reclaim timer will commence and the relay will reset after the reclaim time expires. e) If the mode switch was set to "S", the relay will go to lockout after the reclaim time expires and will require a manual reset (panel push button). f) If the fault has not cleared ("dummy" CB fail to close) then the relay will go to lockout after the reclaim time expires and will require a removal of auxiliary supply. g) Set the blocking switch to Live Line and the "dummy CB "to tripped. Apply an initiate pulse, RL1 will pick as will RL3 and the relay will go directly to lockout and will require a removal of auxiliary supply. OK h) For full timing details refer to the timing waveforms in the product Maintenance Manual. i) Check that the relay is electrically sound and mechanically robust as per Standard Inspection & Test Schedule 903.000.026. PASS TESTED BY: DATE:

Sheet 6 of 6 8. CONNECTION DIAGRAM