Table of Contents 1. GENERAL... 3

Similar documents
SECTION GROUND WATER STORAGE TANKS

Residential Deck Safety, Construction, and Repair

BLADDER SURGE CONTROL SYSTEM

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)

James M. Pleasants Company

STANDARD SPECIFICATION FOR STORAGE TANKS

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Calvert USA, Inc. Attic Stairs

STATEMENT OF WORK (SOW) On-Call Certified Welding Inspections and Nondestructive Testing

SECTION 1 GENERAL REQUIREMENTS

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

UltraTech International, Inc. Canadian Secondary Containment Requirements

Arctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009

1.02 SYSTEM DESCRIPTION

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

ABOUT CWB CERTIFICATION/ QUALIFICATION The work CWB does on behalf of our clients can be divided into five main categories:

City of San Diego, CWP Guidelines

SECTION PRECAST CONCRETE UTILITY STRUCTURES

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Pressure vessel basics for all engineers

Pee Dee Empty Oil Storage Tank at

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

DENVER MODEL 30 X 30 SPECIFICATIONS

TABLE OF CONTENT

SECTION STORM DRAINAGE SYSTEM

Chapter 3 Pre-Installation, Foundations and Piers

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

External Visual Inspection Form

SANITARY SEWER SPECIFICATIONS

Mechanical Installation

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Uncovered Decks & Porches

INSTALLATION. General. Important Note. Design. Transport

Fire Pump Plan Review March 2010

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

TARIFF CODE and updates standard

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

Preformed Metal Roofing and Siding

COLORADO MODEL. 35 x 65 SPECIFICATIONS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Steel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Excerpts from the Canadian National Building Code (NBC)

Welding Codes and How They're Used (DOD) (ANSI). (AWS), (ASME) (API). not American Welding Society AWS D1.1 AWS D1.2 AWS D1.3 AWS D1.4 AWS D1.

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

PART 1 GENERAL 1.1 SECTION INCLUDES

List of Frequently Utilized Storage Tank Standards and Practices

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

NFPA31FuelOilPiping 1 Revised

INDEX. Sec. No. Items Page Nos.

SECTION WINDOW WASHING SYSTEMS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Mark Cramer Inspection Services, Inc.

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Requirements for Building Application Submission

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Essentials Welding QA/QC Plan Sample

IBC Tote Containment Sumps

Cellar Tech Containment Well Cellar Systems

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

High Strain Dynamic Load Testing of Drilled Shafts

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

Les Produits MURPHCO Ltée

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

Waste Oil Collection / Storage

Code of Standard Practice for Timber Frame Structures

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

SPECIFICATION Section Insulated Precast Concrete Wall Panels

SYSTEM INSTALLATION AND INSPECTION MANUAL HEATING OIL STORAGE TANK SYSTEMS

STANDARDS FOR THE MATERIALS

Itemized RAI Responses

CLEAR-DIVISIONS CENTERFOLD

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

2010 Residential Water Heater Replacement Check List

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

Transcription:

Table of Contents 1. GENERAL... 3 1.1 Documents... 3 1.2 References... 3 1.3 Submission Requirements... 3 1.4 Shop Drawings... 4 1.5 Quality Assurance... 5 1.6 Specifications Requirements For Shop Fabricated, Fuel Storage Tanks 4640-TK-006, 4640- TK-007, 4640-TK-008, 4640-TK-009,4640-TK-010, 4640-TK-011 4640-TK-012, 4640-TK- 013, 4640-TK-014, 4640-TK-015, 4640-TK-016, 4640-TK-017, 4640-TK-018, 4640-TK-019... 5 1.7 Specifications Requirements For Shop Fabricated, Fuel Storage Tanks 4640-TK-020, 4640- TK-021, 4640-TK-022, 4640-TK-023, 4640-TK-024 (Future Jet Tanks)... 7 2. PRODUCTS... 8 2.1 Steel Tank... 8 3. EXECUTION... 11 3.1 Installation... 11 3.2 Field Quality Control... 11 3.3 Repair of Defective Welds... 12 Page ii

1. GENERAL 1.1 Documents Conform to the requirements stated in the General Conditions, the Supplementary General Conditions, the General Requirements, this specification and all addenda. 1.2 References 1. Applicable federal, provincial and territorial codes 2. API 650, 11th Edition, 2008, Welded Steel Tanks for Oil Storage including Addendums 1 and 2 3. API 653 4th Edition, 2009, Tank Inspection, Repair, Alteration and Reconstruction 4. National Building Code of Canada (NBC) 2010 5. National Fire Code of Canada (NFCC) 2010 6. NFPA 30, 2008 Edition, Flammable and Combustible Liquids Code 7. CCME Environmental Code of Practice for Aboveground and Below Ground Storage Tank Systems containing Petroleum and Allied Petroleum, 2003 8. ANSI / ASME B31.3-2010, Process Piping 9. CSA W47.1-09, Certification of Companies for Fusion Welding of Steel 10. CSA W59-03 (R2008) - Welded Steel Construction (Metal Arc Welding) 11. Canadian Environmental Protection Act 1999, (2008 Update), Storage Tank System for Petroleum Products and Allied Petroleum Products Regulations 12. CSA W178.2-08, Certification of Welding Inspectors 1.3 Submission Requirements Coordinate each submission with requirements of work and Contract Documents. Individual submissions will not be reviewed until all related information is available. Allow seven (7) days for Owner or Owner s representative s review of each submission. Accompany submissions with transmittal letter containing: 1. Date 2. Project title and number 3. Contractor's name and address Page 3 of 12

4. Identification and quantity of each shop drawing, product data and sample 5. Other pertinent data Submissions shall include: 1. Date and revision dates 2. Project title and number 3. Name and address of: i) Subcontractor ii) Supplier iii) Manufacturer 4. Contractor's stamp, signed by Contractors authorized representative certifying approval of submissions, verification of field measurements and compliance with Contract Documents. 5. Details of appropriate portions of Work as applicable: a) Fabrication b) Layout, showing dimensions, including identified field dimensions, and clearances c) Setting or erection details d) Capacities e) Performance characteristics f) Standards 1.4 Shop Drawings g) Operating weight h) Relationship to adjacent work Shop drawings: original drawings or modified standard drawings provided by Contractor, to illustrate details of portions of Work, which are specific to project requirements. Shop drawing data information to be submitted in PDF or Cad format via email or FTP. Cross-reference shop drawing information to applicable portions of Contract Documents. Page 4 of 12

1.5 Quality Assurance Contractor to submit quality inspection and test plan for tank construction. Include milestone signoff sheets and qualifications for inspection personnel. 1.6 Specifications Requirements For Shop Fabricated, Fuel Storage Tanks 4640-TK- 006, 4640-TK-007, 4640-TK-008, 4640-TK-009,4640-TK-010, 4640-TK-011 4640- TK-012, 4640-TK-013, 4640-TK-014, 4640-TK-015, 4640-TK-016, 4640-TK-017, 4640-TK-018, 4640-TK-019 Design, supply, fabricate, erect and test four (4) welded steel (Diesel) storage tank meeting the following criteria: 1. Number of tanks = 15 2. Nominal capacity =1,000,000 Liters 3. Diameter: 12 meters 4. Height: 9 meters 5. Specific gravity of contents = 0.82 0.95 6. Appurtenances: (See Part 2 Products) 7. Design metal temperature extremes to National Building Code of Canada (NBC) data for Arctic Bay, Nunavut 8. Design Pressure: Depth of fluid with tank at atmospheric and a 0.5 oz pressure / vacuum vent 9. Design for tanks to incorporate a center column 10. Location FOB Steensby Inlet, Baffin Island Nunavut 11. Permits, Fees for Construction: Owner's responsibility 12. Live Load (Wind Velocity): 1/10= 0.40 kpa, 1/50=0.55 kpa 13. Live Load (Ground Snow Load): Ss = 2.1 kpa 14. Foundation Type: prepared sand and gravel bedding (by civil contractor) 15. Operating Temperature Range: -45 C to 20 C 16. Plate and structural steel specification: (bottom, shell and roof) = CSA G40.21, Structural Quality Steels 260WT Category 4 to -50 F 17. Mill test reports on steel: Supplied by Contractor Page 5 of 12

18. Tank Plate thicknesses: Bottom Plate, minimum thickness 6mm or to API 650 standards, whichever is greater; Shell Plate, minimum thickness 6mm or to API 650 standards, whichever is greater; Roof Plate, to API 650 minimum requirement 19. Roof supports: framing as required to API 650 20. Seismic data to National Building Code of Canada (NBC) edition for Arctic Bay, Nunavut 21. Allowable Site Sub Base Soil Bearing Resistance: 168 kpa (3500 psf) 22. All shell / roof nozzles shall have slip-on flanges unless noted otherwise 23. In lieu of a frangible joint roof connector the tanks shall be designed to incorporate two (2) emergency relief manholes API flange drilling 24. Tank Chime: Floor plate protection at shell connection shall be 75 mm or to API 650, whichever is greater 25. All nozzle heights and projections shall be as noted on the drawings and exceed API 650 minimum requirements 26. Tank floor plates shall be overlapped in a manner to reduce the tendency for liquid to puddle during draw down toward the exterior shell 27. The tank shall be constructed with three (3) water draw off sumps sized to API 650 requirements 28. Tanks shall be designed to incorporate lifting lugs located in strategic positions which will enable a safe and stable lift for the loading on flatbeds in preparation for land and sea transportation to project site 29. All tank trim, railing, stairs and platforms and associated support framing will be shipped loose to project site 30. All tank manways, nozzles, and associated trim openings shall be blinded off and / or plugged in preparation for transportation to project site Page 6 of 12

1.7 Specifications Requirements For Shop Fabricated, Fuel Storage Tanks 4640-TK- 020, 4640-TK-021, 4640-TK-022, 4640-TK-023, 4640-TK-024 (Future Jet Tanks) Design, supply, fabricate, erect and test five (5) welded steel (Future Jet A1) storage tanks meeting the following criteria: 1. Number of tanks = 5 2. Nominal capacity =1,000,000 Liters 3. Diameter: 12 meters 4. Height: 9 meters 5. Specific gravity of contents = 0.82 0.95 6. Appurtenances: (See Part 2 Products) 7. Design metal temperature extremes to National Building Code of Canada (NBC) data for Arctic Bay, Nunavut 8. Design Pressure: Depth of fluid with tank at atmospheric and a 0.5 oz pressure / vacuum vent 9. Design for tanks to incorporate a center column 10. Location FOB Steensby Inlet, Baffin Island Nunavut 11. Permits, Fees for Construction: Owner's responsibility 12. Live Load (Wind Velocity): 1/10= 0.40 kpa, 1/50=0.55 kpa 13. Live Load (Ground Snow Load): Ss = 2.1 kpa 14. Foundation Type: prepared sand and gravel bedding (by civil contractor) 15. Operating Temperature Range: -45 C to 20 C 16. Plate and structural steel specification: (bottom, shell and roof) = CSA G40.21, Structural Quality Steels 260WT Category 4 to -50 F 17. Mill test reports on steel: Supplied by Contractor 18. Tank Plate thicknesses: Bottom Plate, minimum thickness 6mm or to API 650 standards, whichever is greater; Shell Plate, minimum thickness 6mm or to API 650 standards, whichever is greater; Roof Plate, to API 650 minimum requirement 19. Roof supports: framing as required to API 650 Page 7 of 12

20. Seismic data to National Building Code of Canada (NBC) edition for Arctic Bay, Nunavut 21. Allowable Site Sub Base Soil Bearing Resistance: 168 kpa (3500 psf) 22. All shell / roof nozzles shall have slip-on flanges unless noted otherwise 23. In lieu of a frangible joint roof connector the tanks shall be designed to incorporate 2 (two) emergency relief manholes API Flange drilling 24. Tank Chime: Floor plate protection at shell connection shall be 75 mm or to API 650, whichever is greater 25. All nozzle heights and projections shall be as noted on the drawings and exceed API 650 minimum requirements 26. Tank floor plates shall be overlapped in a manner to reduce the tendency for liquid to puddle during draw down toward the exterior shell 27. The tank shall be constructed with three (3) water draw off sumps sized to API 650 requirements 28. Jet A1 tank shall have internal coatings Refer to specification 09915 29. Tanks shall be designed to incorporate lifting lugs located in strategic positions which will enable a safe and stable lift for the loading on flatbeds in preparation for land and sea transportation to project site 30. All tank trim, railing, stairs and platforms and associated support framing will be shipped loose to project site 31. All tank manways, nozzles, and associated trim openings shall be blinded off and / or plugged in preparation for transportation to project site 2. PRODUCTS 2.1 Steel Tank Plate material for tank shall be furnished to CSA G40.21-04 in Grade 260WT Category 4 to -50 F, rolled, kilned and made to fine grain practice. Construction (vertical): to API standard 650. All shell, floor and roof attachments are to have doubler plates. All column bases are to have doubler plates with minimum 150 mm beyond column base plate bearing surfaces. Page 8 of 12

Tank appurtenances: 1. See drawings for list and sizes and as described in this section. 2. All internal studs, nuts and fasteners shall be stainless steel. ASTM A193, Grade B8M and ASTM A194, Grade 8/8M. 3. Manway cover bolts and nuts shall be cadium plated. ASTM B766-86 (2008). Railings, stairs and platform: Design to API standard 650, Table 5-19 and as shown on the drawings and outlined herein. Stair tread, platform grating, handrail and supports: 1. Stair treads: Diamond grip, galvanized steel 12 gauge - 915 wide x 241 deep x 38 2. Platform Grating: Diamond grip, safety grating, pre-galvanized steel, 12 gauge with 38 mm channel, length and width to suit dimensions shown on the drawing 3. Guard rails at Walkways and Tank Roof: a) Rails: 50 x 50 x 6 mm angle. Railing height on platform measured from top of grating to top of rail. Intermediate rail 610 mm from top of platform to centerline of rail b) Posts: 50 x 50 x 6 mm angle at 1500 mm c/c maximum spacing c) Toe Plate: 125 mm height x 6 mm thick plate 4. Handrails at Stairs: a) Rails: 50 x 50 x 6 mm angle b) Railing height from toe of tread to top of rail: 1067 mm c) Posts: 20 square bar x 1130 mm long 5. Loadings: complete structure shall be capable of supporting a moving concentration load of 455 kg, and the handrail structure shall be capable of withstanding a load of 91 kg applied in any direction at any point on the top rail 6. Steel support framing: structural steel to CSA G40.21, grade 350 W weldable Steel 7. Railing, stairs and platforms to meet all local, provincial, territorial and federal regulations. Page 9 of 12

All tank attachments are to be fastened by use of seal welded doubler plates. API Inspection and testing of tank: 1. Inspection of roof welds shall be as per API Standard 650, Section 8 Methods of Inspecting Joints including complete visual inspections. 2. Inspection of shell - radiograph inspections of butt welded shell seams shall be as per API 650 Code Section 8 including complete visual inspections. 3. Inspection of floor welds shall be as per API 650 Section 8 including complete visual and complete vacuum box testing. 4. Inspection of floor to shell joint shall be as per API Standard 650 Section 8 including complete visual, liquid penetrant and vacuum box testing. 5. Inspection of roof to shell joint shall be as per API Standard 650 Section 8 including complete visual testing. 6. Inspection of nozzle to shell or nozzle to reinforcing pad welds shall be as per API Standard 650 Section 8 including Mag Particle testing of the back gouged root pass weld and Mag Particle and UT of the completed weld. Reinforcing pad to shell welds shall be tested by Mag Particle and the Reinforcing pad shall be pressure tested. 7. Inspection of double plates shall be as per API Standard 650 Section 8 and API Standard 653 including complete visual and vacuum box testing. 8. All Visual Inspection shall be to API standard 650. 9. All Dimensional Tolerances shall be to API standard 650. 10. All Welding shall be to CSA W47.1, CSA W178.2, and CSA W59. 11. Welders to be certified in accordance with CSA W47.1-03. 12. Submit records of Welders certification and test results to Owner or Owner s Representative. Page 10 of 12

3. EXECUTION 3.1 Installation Install tanks in accordance with API standard 650 and the National Fire Code of Canada. Contractor shall take care as to not puncture the dyke membrane with scaffolding and / or digging. Any damage to the membrane shall be repaired as instructed by Owner or Owner s Representative at no additional cost to the Owner. Position tanks using lifting lugs and hooks, and where necessary use spreader bars. Do not use chains in contact with tank walls. 3.2 Field Quality Control Test tank for leaks in presence of Owner or Owner s Representative. Field test for leaks in accordance with API 650. API monogram is acceptable evidence of testing. Contractor shall confirm that tank base finish grade elevation tolerances are within acceptable range before and after floor plate installation as per API-650. Tank shall be hydrostatically tested for a period of 24 hours and monitored for leaks and/or level change during the test period. Contractor is responsible for the supply and disposal of hydrostatic test water. All water shall be clean and free of rust and other foreign particles. All costs associated with hydro-testing shall be by the contractor. Owner or Owner s Representative shall outline method of test water discharge once completed. Tank shall be surveyed in two locations per quadrant before test, after construction is complete. Further survey shall be completed during testing at: 1. 25% Full 2. 50% Full 3. 100% Full 4. Empty (post-testing) In lieu of a hydrostatic test which may not be practical in this instance, additional shell testing shall be performed on all welds by: (1) performing an penetrating oil test by applying oil to the interior side of the weld and examining the exterior or (2) by applying a soapy water solution and a vacuum to either side of the weld as per Section 7.3.5 of API 650. All costs associated with testing shall be by the Contractor. All test results shall be provided to the Owner or Owner s Representative for review upon completion. Page 11 of 12

3.3 Repair of Defective Welds Requirements outlined in API standard 650 and at contractor's expense. Additional testing as a result of defective welds is at Contractor s expense. Page 12 of 12