STEM BUILDING BASEBALL CARDS TYPICAL ROOM INFORMATION

Similar documents
EARLY CHILDHOOD EDUCATION September 30, 2010

BUILDING NAMING RIGHTS

MSBA Guidelines for Science Labs

Clear Creek Business Center 187,865 Sq. Ft. OFFICE/FLEX/INDUSTRIAL

62% 40% 96% 90% 77% 40%

Peralta Community College District th Avenue Oakland, California Phone (510) Fax (510) Purchasing Department

H107 Video Conference Room

A1.5 Classroom Standards

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

New Hanover County Schools Middle School Educational Specifications Media Center. Overview. Spatial Relationships

1/9/2015 P:\ \Project Management\Program\Ripon Space Program - 7 January 2015.xlsx

RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements

Addition and Renovation Northview Elementary School Design Development Manual

ARAPAHOE COMMUNITY COLLEGE

TURN-KEY LAB SPACE AVAILABLE

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Element D Services Plumbing

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

Montgomery County Public Schools Facilities Guide DIVISION 16 ELECTRICAL

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Part 2 Definitions for this Policy 2.1. ADA / TAS the Americans with Disabilities Act / Texas Accessibility Standards.

SPACE TYPES & REQUIREMENTS

New York, Dean. Price 182,500

Delaware Valley College

Element Z General Design Requirements Owner Standards and other Requirements

October 5, 2015 Dear Client,

15430 SAFETY SHOWERS AND EYEWASHES

Building Condition Assessment Report

HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS PRIMARY CARE CLINICS

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SECTION XI OPINION OF PROBABLE COST

Academic Learning and Teaching Center Classrooms

Base Cabinet with Self-storing Folding Doors and Floor

HA5 4JX T: NEW Instruction. One Bedroom Retirement Flat for the over 60's. Greater London HA5 4JX. 523 Uxbridge Road Road

JSP 315 SCALE 45 1 OFFICES

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

THE UNIVERSITY OF EDINBURGH. Number 5 Forrest Hill

Self-Home Inspection Checklist

2012 BIM Guidelines and Standards (Rev. 00) University at Albany

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

COMPUTER LAB CLASSROOMS. A Planning Guide

HOUSING QUALITY STANDARDS (HQS)

Frequently Asked Questions About the District of Columbia School Health Nursing Program

Supporting Agile Software Development With Agile Team Work Space

SAFETY SELF-INSPECTION PROGRAM

Huizenga College Classrooms & Technology Capabilities

Remodel Projects. Photos by Marvin Dodge

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Element D Services Plumbing

The White House 15 Whirlow Park Road, Sheffield. Park Estates

Risk Assessment: Biosafety Cabinet

Summit Series Single Section and Double Section Homes

CONSTRUCTION PROGRESS MONITORING REPORT

LABORATORY CASEWORK. Table of Contents. Laboratory Cabinetry and Specialties. ADVANTAGE laboratory. Series/Model Number Specification...

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

INTERIOR CONCEPTS Contact Center

You can do it all yourself. But you don t have to.

How to Design Your Perfect Kitchen in Just 15 Minutes Using Microsoft Word

LAB BENCHES & SPECIALTY INSTRUCTOR'S BENCHES

Back Porch. Insulation Option # 2 Includes Option #1 plus, Insulate Walls Separating Both Master Suites and Leisure Room

Board Seminar Facilities. School Year Submitted by Joseph L. Lisa-Director of Facilities

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

Case Study Design For Innovative Learning

Designing a Facility: Making It a Place Where Every Student Succeeds

Champaign Public Library Meeting Room F.A.Q.

Florida s Cottage Food Industry and Beyond

the Rehabilitation Plan

5 CEDAR BROOK D R I V E C R A N B U R Y, N J 1

University of Calgary Space Classification - September 2014 (version 8)

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

The UPLANDS at ORO VALLEY Sterling Features

Kitchen Planning Guidelines With Access Standards

GENERAL WIRING RULES FOR HOUSES

Fume Hood Questions and Answers

Design an Effective TRAINING SPACE. White Paper

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Design Questionnaire. Design & Style

CONDOMINIUM FACT SHEET: INSURANCE

Laboratory Design & Construction Guidelines

PUBLIC RESTROOMS, DESIGN INTENT

Section 4 EMERGENCY EYEWASH AND SAFETY SHOWER EQUIPMENT

A Project Description/Project Title and Data: Building Area: (sf) Addition 28,142 Renovation 14,302. Cost per Square Foot: +/- $106.

DEARBORN HEIGHTS SCHOOL DISTRICT NO. 7 Sinking Fund Projects 10 Year Plan Proposal ( )

costs and billing Facilities Services State-Funded and Billable Services Centrally Funded Services for State Supported Spaces Billable Services

MP 5.7 RESIDENTIAL SERVICES BUILDING STANDARD

APC APPLICATION NOTE #92

THE UNIVERSITY OF EDINBURGH George Square Library

Damage Charge Lists. FLOORING Replace Repair Carpet per square foot (Mohwak heat carpet tile)

How To Check If A Building Is Safe For A Disabled Person

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO (216) POINT OF SALE CERTIFICATE OF INSPECTION

Designing from the Inside Out: The Design of Specialist Spaces in Secondary Schools. Workshop 1: Science Lab Design

SERC Audio Visual Options

PARKVILLE HIGH SCHOOL LIMITED RENOVATION

Estimating Database Checklist

Innovative Storage and Distribution System

Turku University Of Applied Sciences Ltd furniture and equipment for the student laboratories of the degree programme in dental technology 1 (9)

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Data Center Components Overview

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms

17,280 square feet Overview:

Transcription:

NORTH DAKOTA STATE UNIVERSIT Y BASEBALL CARDS TYPICAL ROOM INFORMATION 07.15.2014

MT MOVEABLE TABLES LAB QTY: 10 Occupants: 24 and 32 Fume Hoods: Plumbed Services: Sinks: Student Stations: Casework: Electrical: Exhaust Air System: Eyewash/Shower: Floor drain: Projector, manual screen, and fixed presenter station at perimeter (2) Natural gas ports at perimeter (3) at perimeter Moveable tables (24) storage cubbies, microscope storage, base cabinets 24 at front wall Wireless and several data jacks around perimeter Standard 110v perimeter wiremold, overhead retractable cord reels for tables Room Purge Yes First and Second (1) MT lab better accommodates electronics-based courses (2) MT labs can accommodate up to 36 students 8@ 24 STUDENTS 2@ 36 STUDENTS University of Wisconsin-Stout STEM EDUCATION BUILDING

H2 TWO FUME HOOD LAB QTY: 2 Occupants: 24 Fume Hoods: Plumbed Services: Sinks: Student Stations: Projector, manual screen, and fixed presenter station at perimeter (1) 4-0 wide and (1) 6-0 wide with lab air, natural gas, vacuum, and cupsinks Natural gas, lab air, vacuum, and pure water at island benches (3) at island benches Fixed island benches Casework: (24) storage cubbies, 140 student drawers, base cabinets Electrical: Exhaust Air System: Eyewash/Shower: Floor drain: 24 at front wall Wireless and several data jacks around perimeter Standard 110v perimeter wiremold, and at benches Standard Yes Third Adjacent H2 lab prep space. University of Wisconsin-Stout University of Wisconsin-Stout STEM EDUCATION BUILDING

H8 EIGHT FUME HOOD LAB QTY: 6 Occupants: 24 Fume Hoods: Plumbed Services: Sinks: Student Stations: Projector, manual screen, and fixed presenter station at perimeter (8) 4-0 wide with lab air, natural gas, vacuum, and cupsinks. (1) 4-0 wide hood for waste Services in fume hoods (3) at perimeter of room Fixed island benches Casework: (24) storage cubbies, 300 student drawers, base cabinets. Storage behind marker boards Internet /Data: Electrical: Exhaust Air System: Eyewash/Shower: Floor drain: 16 at front wall Wireless and several data jacks around perimeter Data acquisition system Standard 110v at perimeter and at islands Standard Yes Third (1) H8 prep space and chemical storage room adjacent to all H8 labs Instrumentation room on the same floor University of Wisconsin-Stout STEM EDUCATION BUILDING

BSL2 BIO SAFETY LEVEL 2 LAB QTY: 2 Occupants: 24 Fume Hoods: Plumbed Services: Sinks: Student Stations: Projector, manual screen, and fixed presenter station at perimeter (2) 4-0 Bio safety cabinets Natural gas at island benches 3 at island benches Fixed island benches Casework: (24) storage cubbies, 60 student drawers, microscope storage, base cabinets, lab coat storage Internet Access: Electrical: Exhaust Air System: Eyewash/Shower: Floor drain: 24 at front wall Wireless and several data jacks around perimeter Standard 110v perimeter wiremold and at island benches Standard Yes Second Adjacent BSL2 prep space with walk-in cold rooms, sterilizers, and lab washer. STEM EDUCATION BUILDING

PBL PROJECT BASED LEARNING QTY: 1 Occupants: 48 Best Use: SF/person: 39 Internet Access: (2) Projectors, manual screens, and presenter table 40 at front wall, 16 at side wall Group Work, Discussion, Collaboration, Lecture Wireless and data jacks around perimeter First Adjacent storage room. Plans (below) show alternate furniture layouts. STEM EDUCATION BUILDING

FLUIDS LAB QTY: 1 Occupants: 24 Fume Hoods: Plumbed Services: Sinks: Student Stations: Casework: Projector, manual screen, and fixed presenter station at perimeter Compressed air (1) wall mounted hand wash sink and (1) laundry tub, ceiling hose reel Mobile chairs, moveable tables for equipment Lockable tall storage cabinets 24 at front wall Exhaust Air System : Room Purge Floor drain: Eyewash/Shower: Electrical: Trench drain at rear of room Yes Standard 110v ceiling cord reels, specialty power at perimeter Wireless and data jacks First No ceiling, exposed to structure above 8-0 wide overhead door to exterior Coe College STEM EDUCATION BUILDING

LAB PREP AND STORAGE Occupants: 1-8+ (varies) Quantity: Storage at Auditorium, (2) MT prep and storage, H8 prep and storage, H8 Instrumentation, Chemical storage, H2 prep and storage, BSL2 prep and storage, and BSL2 Equipment. Fume Hoods: Plumbed Services: Size varies. One or more hoods in MT preps, H8 prep, H2 prep. Services include Lab air, Natural gas, vacuum and cupsinks. Varies. Pure water, other services in hoods. Exhaust Air System : Room Purge typically Floor drain: Eyewash/Shower: Electrical: Yes Standard 110v Wireless and data jacks Varies, see plans Walk-in coolers and lab washers in main MT prep space and BSL2 prep, sterilizers in BSL2 prep. SECOND LEVEL THIRD LEVEL FIRST LEVEL STEM EDUCATION BUILDING

AUDITORIUM QTY: 1 Occupants: 295 Fume Hoods: Plumbed Services: Sinks: Best Use: SF/person: 13 Electrical: (2) Projectors, fixed screens, and fixed presenter station at front Downdraft hood at demonstration station Lab air, natural gas, vacuum at demonstration station (1) at demonstration station 40 at front wall Lecture Demonstration Wireless and several data jacks around perimeter Power available at 1/3 of seats First (5) Accessible areas Room slopes to front Storage at front left Ceiling height: 10 17 Acoustical panels at back and side walls 3M Leadership Development Institute STEM EDUCATION BUILDING

LECTURE HALL QTY: 1 Occupants: 95 Best Use: SF/person: 25 (2) Projectors, manual screens, and fixed presenter station at front 36 at front wall Lecture, Group Work Wireless and several data jacks around perimeter First Two rows per floor landing allows students to turn around for group work Acoustical panels at back and side walls University of Wisconsin-Stout STEM EDUCATION BUILDING

ALC ACTIVE LEARNING CLASSROOM (med) QTY: 5 Occupants: 55-80 Best Use: SF/person: 29-32 Internet Access: (2) Projectors, manual screens, and fixed presenter station at perimeter 42 at front wall, additional at side and back walls Group Work, Discussion, Lecture Collaboration Wireless and several data jacks around perimeter Second and Third Marker board on walls around room. Multiple options for furniture layout STEM EDUCATION BUILDING

ALC ACTIVE LEARNING CLASSROOM (large) QTY: 1 Occupants: 126 Best Use: SF/person: 25 Internet/Data (6) Projectors, manual screens, typically fixed presenter station at center. Monitor per table Group Work, Discussion, Lecture, Collaboration Wireless and several data jacks at tables and around perimeter First Fixed tables with power and data are each connected to a monitor, and each table could push content to the large screens UMN Veterinary Medicine STEM EDUCATION BUILDING

COMPUTER CLUSTER QTY: 1 Occupants: 48 Student Stations: Casework: Best Use: SF/person: 34 (2) Projectors, manual screen, and fixed presenter station at front 24 at front wall Moveable tables Printers on countertop with paper storage below. Hands on training Wireless, data jacks in furniture at tables, data jacks at printer stations and around perimeter Second Computer at each chair Gustavus Adolphus College STEM EDUCATION BUILDING

M. Union University Drive N INFORMAL LEARNING Occupants: 1-8+ (varies) Quantity: (6) rooms, (7) nooks, and several seating areas in the building Monitors in enclosed spaces and nooks Best Use: Individual Study Group Work, Discussion, Collaboration SF/person: Varies Wireless and data jacks Varies, see plans Variety of seating areas throughout the building provide comfortable, safe, well-lit spaces that encourage choice whether studying, lounging, gathering, or collaborating. SECOND LEVEL THIRD LEVEL Churchill Field will be preserved and improved, to the east between STEM and University Avenue. Churchill Field Outdoor seating FIRST LEVEL STEM EDUCATION BUILDING