Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

york air-conditioning products Residential & VRF News 2015

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

LG Electronics AE Company, Commercial Air Conditioning

FULL DC INVERTER SYSTEMS

Unico Inverter. Unique and efficient.

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

FTQ. Daikin Inverter Ducted Heat Pump

Appendix - Controllers 179

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

ECOCIAT. Domestic hot water heat recovery unit

Inverter Air Conditioning for Light Commercial Use

DUCTED AIR CONDITIONING SOLUTIONS

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Air conditioners Heating & Cooling

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

M Series. Room Air Conditioning

YUTAKI S. Domestic Heating

CRAC Precision climate control units for data centres

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

HP switch LP switch Discharge thermo Comp. Surface thermo

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Daikin Altherma hybrid heat pump. The natural combination

NEW 3-PIPE ECOi MF2 SERIES

2015 / 16. price list. Airconditioning systems

Air Conditioning for Small and Medium-size Buildings

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

-~ available. Power consumption during operation is substantially less than that of lower rated

The natural ombination

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Air Conditioners Technical Data

Cooling kw Heating kw

Test Report issued under the responsibility of:

How To Design A Building In New Delhi

FCQ. Roundflow Cassette Heat Pump or Cooling Only

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

FBQ. DC Duct Heat Pump or Cooling Only

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

FHQ. Ceiling Suspended Heat Pump or Cooling Only

GREE, MAKING BETTER AIR CONDITIONERS

HVAC Systems: Overview

Daikin Altherma. hybrid heat pump. The natural combination

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

TWE+TTA TWE+TWA T.R.

2010 Duct-Free Splits Line Card

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

LOCAL AIR-CONDITIONERS

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Inverter Air Conditioning for Light Commercial Use

PANASONIC TROUBLE SHOOTING GUIDE

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.

FTXS. Wall Mount Heat Pump or Cooling Only

LG Air Conditioning & Energy Solutions Price List

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

SWIMMING POOL HEAT PUMP Owners Manual


Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Air Conditioning For Large Buildings

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

technology innovation, comfort for your home. The perfect blend of

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

PRODUCT CATALOG. Indoor Units

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Pioneer in sustainability

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

AIR-CONDITIONER SPLIT TYPE

HEAVY DUTY STORAGE GAS

Residential. Commercial Controls Multi XRV Plus System Technical courses Key to icons 76-79

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Hot Water. Heat pump water heaters. Residential and Commercial R410a

UDSA - UDSBD unit heater

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

UTOPIA DC-INVERTER ES SERIES HVRN1/H(V)RNS(E)

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

AIR CONDITIONING and HEAT PUMP PRODUCTS

We have been working in an ideal climate for thirty years.

IR410AI. The flexible solution. Simple, one touch control

Failure code manual. content

Bring the fresh in. Dedicated Outside Air Systems

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

ECO-AIR AIR CONDITIONING

Transcription:

Ducted in the Ceiling 54 More information on controls and options on pages 257272

DUCTED IN THE CEILING Hitachi s Ducted range can be positioned discreetly in the ceiling. The units are ideal for hotel bedrooms, banks and small offices where very low noise levels are needed. COP 3.61 MONOZONE Standard pressure RAD 25 50 RPA pages 58 and 59 COP 3.77 MONOZONE High pressure RAD 50 70 PPA pages 58 and 59 COP 3.59 UTOPIA ES RPI 5 6 FSN4E / RPI 8 10 FSN3E pages 60 and 61 COP 4.03 UTOPIA IVX COMFORT RPI 4 6 FSN4E / RPI 8 10 FSN3E pages 62 and 63 COP 4.23 UTOPIA IVX PREMIUM RPI 2 6 FSN4E / RPI 8 10 FSN3E pages 64 and 65 COP 3.80 UTOPIA IVX CENTRIFUGAL RPI 4 6 FSN4E / RPI 8 10 FSN3E pages 66 and 67 55

Ducted in the Ceiling UTOPIA ES +21 15 +43 10 RPI 36FSN4E PC ARF RAS 3HVRNS3 RPI 810FSN3E PC ART RAS 46H(V)RNS3E RAS 810HRNSE Indoor units Nominal cooling capacities 7.1kW to 25.0kW Nominal heating capacities 8.0kW to 28.0kW Ultra low power consumption Ultra Quiet from 29 db(a) 4 speed, 3 static pressure levels, including zero pressure setting Possible to supply fresh air : Econofresh see pages 208209 Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages 262263. Outdoor units Compact design single fan (up to 6HP) SCOP of up to 3.83 A rating and SEER of up to 4.62 B rating Available in single phase and three phase RPI 56FSN4E 60 More information on controls and options on pages 257272

UTOPIA ES Ducted in the Ceiling INDOOR UNITS RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 7.1 (3.2 8.0) 10 (4.5 11.2) 12.5 (5.7 14.0) 14.0 (6.0 16.0) 20.00 (8.00 22.40) 25.00 (10.00 28.00) Nominal Heating Capacity (min max) (2) kw 8.0 (3.5 10.6) 11.2 (5.0 14.0) 14.0 (5.0 16.0) 16.0 (5.0 18.0) 22.40 (6.30 28.00) 28.00 (8.00 35.00) UK Cooling Capacity (sensible) (3) kw 7.4 (6.0) 10.3 (7.9) 12.7 (9.1) 15.2 (10.5) 20.1 (15.5) 24.9 (17.9) Seasonal Efficiency SEER (4) Energy Efficiency Class 4.62 B 4.62 B na * na * na * na * Seasonal Efficiency SCOP (4) (Average Climate) Energy Efficiency Class 3.81 A 3.83 A na * na * na * na * Nominal Load Efficiency EER / COP (5) Energy Class (Cool/Heat) 2.81 / 3.54 C / B 3.4 / 3.59 B / A 2.84 / 3.27 C / C 2.67 / 3.18 D / C 2.46 / 3.00 E / D 2.32 / 2.97 F / D Noise Level (sound pressure) (L / M / H) (6) db(a) 29/31/31 32/35/37 33/35/38 33/36/39 51/54/54 52/55/55 Noise level (sound power) (8 ) db(a) 57 62 65 66 77 78 Air flow cooling mode (L / M / H) m 3 /h 960/1140/1320 1500/1680/1800 1740/1920/2100 1800/1980/2160 3570/3960/3960 4056 / 4500 / 4500 Static Pressure Nom. (min ~ max) Pa 30 (0 125) 45 (0 120) 50 (0 140) 50 (0 140) 140 220 140 220 Dimensions (H x W x D) 275x1084x600 275x1474x600 275x1474x600 275x1474x600 423 x 1592 x 600 423 x 1592 x 600 Weight kg 36 48 48 48 85 87 Included Condensate Pump yes yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ25 φ25 3/8 / 3/4 9.53 / 19.05 3/8 / 7/8 9.53 / 22.2 Power Input w 150 250 250 250 1065 1065 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 10 10 Remote Controller PC ART (PC ARF infrared and simplified model optional) OUTDOOR UNITS RAS 3HVRNS3 RAS 4H(V)RNS3E RAS 5H(V)RNS2E RAS 6H(V)RNS2E RAS 8HRNSE RAS 10HRNSE Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 400V / 3Ph / 50Hz 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db(a) 48 (46) 50 (48) 52 (50) 55 (53) 53 (51) 60 (56) Noise level heating (sound pressure) (7) db(a) 50 52 54 57 55 62 Noise level (sound power) (8) db(a) 66 70 71 72 71 78 Air flow (Cooling / Heating) m 3 /h 2682 3720 4080 4800 7620 8760 Dimensions (H x W x D) 600x792x300 800x950x370 800x950x370 800x950x370 1380x950x370 1380x950x370 Weight kg 44 67 83 83 135 141 Piping diameter (Liquid / Gas) 3/8 / 11/8 9.53 / 28.61 1/2 / 11/8 12.07 / 28.61 Minimum Piping Length m 5 5 5 5 5 5 Maximum Piping Length / Height Difference m 50 / 30 50 / 30 50 / 30 50 / 30 50 / 30 50 / 30 Current Quantity of Refrigerant kg 1.90 2.90 2.9 2.9 6.0 6.2 Chargeless / Additional Refrigerant Charge m / g/m 20 / 30 30 / 40 30 / 60 30 / 60 30 / 65 30 / (120) Recoended fuse size 1Ph/3Ph A 25 32/16 32/16 32/16 /32 /32 Starting current (1Ph/3Ph) A <10 <10 <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) A 10.0 / 8.8 (/) 11.3 / 11.3 (4.1 / 4.1) 18.4 / 18.5 (6.5 / 6.6) 24.6 / 23.8 (8.7 / 8.4) / (10.7 / 9.9) / (14.6 / 13.5) Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~43(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Rotary Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN12102 61

Ducted in the Ceiling UTOPIA IVX COMFORT +21 15 +43 10 RPI 36FSN4E PC ARF RAS 3HVNC1 RPI 810FSN3E Indoor units Possible to supply fresh air : Econofresh see pages 208209 Low consumption motor 4 speed, 3 static pressure levels, including zero pressure for blowing onto the grill. PC ART Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages 262263. RAS 456H(V)NC1E Outdoor units RAS 810HNCE Capacities from 3.2kW to 35kW Compact design single fan (up to 6HP) Multi split applications possible SCOP of up to 4.31 A rating and SEER of up to 5.84 A+ rating Available in single phase and three phase RPI 36FSN4E 62 More information on controls and options on pages 257272

UTOPIA IVX COMFORT Ducted in the Ceiling INDOOR UNITS RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 7.1 (3.2 8.0) 10 (4.5 11.2) 12.5 (5.7 14.0) 14.0 (6.0 16.0) 20.00 (8.00 22.40) 25.00 (10.00 28.00) Nominal Heating Capacity (min max) (2) kw 8.0 (3.5 10.6) 11.2 (5.0 14.0) 14.0 (5.0 16.0) 16.0 (5.0 18.0) 22.40 (6.30 28.00) 28.00 (8.00 35.00) UK Cooling Capacity (sensible) (3) kw 7.7 (6.2) 10.6 (8.2) 13.2 (9.5) 15.6 (10.8) 21.1 (16.2) 26.1 (18.8) Seasonal Efficiency SEER (4) Energy Efficiency Class 4.97 B 5.38 A Seasonal Efficiency SCOP (4) (Average Climate) Energy Efficiency Class 3.80 A 4.01 A+ Nominal Load Efficiency EER / COP (5) Energy Class (Cool/Heat) 2.81 / 3.54 C / B 3.10 / 4.03 B / A 3.18 / 3.54 A / B 3.08 / 3.37 B / C 2.84 / 3.07 C / D 2.73 / 3.04 D / D Noise Level (sound pressure) (L / M / H) (6) (SP00) db(a) 29/31/31 32/35/37 33/35/38 33/36/39 51/54/54 52/55/55 Noise level (sound power) (8) (SP00) db(a) 57 62 65 66 77 78 Air flow cooling mode (L / M / H) m 3 /h 960/1140/1320 1500/1680/1800 1740/1920/2100 1800/1980/2160 3570/3960/3960 4056 / 4500 / 4500 Static Pressure Nom. (min ~ max) Pa 30 (0 125) 45 (0 120) 50 (0 140) 50 (0 140) 140 220 140 220 Dimensions (H x W x D) 275x1084x600 275x1474x600 275x1474x600 275x1474x600 423 x 1592 x 600 423 x 1592 x 600 Weight kg 36 48 48 48 85 87 Included Condensate Pump yes yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ25 φ25 3/8 / 7/8 9.53 / 22.2 Power Input w 150 250 250 250 1065 1065 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 10 10 Remote Controller PC ART (PCARF, infrared and simplified model optional) OUTDOOR UNITS RAS 3HVNC1 RAS 4H(V)NC1E RAS 5H(V)NC1E RAS 6H(V)NC1E RAS 8HNCE RAS 10HNCE Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 400V / 3Ph / 50Hz 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db(a) 48 (46) 52 (50) 52 (50) 55 (53) 57 (55) 58 (56) Noise level heating (sound pressure) (7) db(a) 50 54 54 57 59 60 Noise level (sound power) (8) db(a) 66 68 68 71 76 76 Air flow (Cooling / Heating) m 3 /h 2682 3720 4080 4800 7620 8040 Dimensions (H x W x D) 600 x 792 x 300 1140 x 950 x 370 1140 x 950 x 370 1140 x 950 x 370 1380 x 950 x 370 1380 x 950 x 370 Weight kg 44 79 89 89 136 138 Piping diameter (Liquid / Gas) 3/8 / 11/8 9.53 / 28.61 1/2 / 11/8 12.07 / 28.61 Minimum Piping Length m 5 5 5 5 5 5 Maximum Piping Length / Height Difference m 50 / 30 70 / 30 75 / 30 75 / 30 100 / 30 100 / 30 Current Quantity of Refrigerant kg 1.9 3.2 3.2 3.2 5.7 6.2 Chargeless / Additional Refrigerant Charge m / g/m 20 / 40 30 / 40 30 / 60 30 / 60 30 / Calculate 30 / Calculate Recoended fuse size 1Ph/3Ph A 20/ 32/25 32/16 32/16 /32 /32 Starting current (1Ph/3Ph) A <10 <10 <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) A 9.4/8.3 (/) 11.2/10.1 (4.1/3.7) 15.5/15.1 (5.7/5.5) 18.1/19.0 (6.6/6.9) / (9.1/9.0) / (12.9/12.0) Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~46(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN12102 63

Ducted in the Ceiling UTOPIA IVX PREMIUM +21 15 +43 10 RPI 26FSN4E PC ARF RAS 22.5HVNP1 RPI 810FSN3E Indoor units Nominal cooling capacities 5.0kW to 25.0kW Nominal heating capacities 5.6kW to 28.0kW Possible to supply fresh air: Econofresh see pages 208209 Low consumption motor 4 speed, 3 static pressure levels, including zero pressure setting Easily accessible filters. PC ART Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages 262263. RAS 3HVNP1E Outdoor units Compact design single fan (up to 6HP) RAS 410H(V)NP1E Fully ErP compliant with A++ seasonal efficiency Available in single phase and three phase. RPI 26FSN4E 64 More information on controls and options on pages 257272

UTOPIA IVX PREMIUM Ducted in the Ceiling INDOOR UNITS RPI 2.0FSN4E RPI 2.5FSN4E RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 5.0 (2.2 5.6) 5.6 (2.2 6.3) 7.1 (3.2 8.0) 10 (4.5 11.2) 12.5 (5.7 14.0) 14.0 (6.0 16.0) 20.0 (8.0 22.4) 25.0 (10.0 28.0) Nominal Heating Capacity (min max) (2) kw 5.6 (2.2 7.1) 6.3 (2.2 8.0) 8.0 (3.5 10.6) 11.2 (5.0 14.0) 14.0 (5.0 16.0) 16.0 (5.0 18.0) 22.4 (6.3 28.0) 28.0 (8.0 35.0) UK Cooling Capacity (sensible) (3) kw 5.3 (4.7) 5.9 (5.1) 7.7 (6.2) 10.6 (8.2) 13.2 (9.5) 15.7 (10.8) 21.1 (16.2) 26.1 (18.8) Seasonal Efficiency SEER (4) Energy Efficiency Class 5.83 A+ 5.51 A+ 6.05 A++ 6.45 A++ Seasonal Efficiency SCOP (4) (Average Climate) Energy Efficiency Class 4.01 A+ 4.33 A+ 4.00 A++ 4.23 A+ Nominal Load Efficiency EER / COP (5) Energy Class (Cool/Heat) 3.54 / 3.73 A / A 3.49 / 3.81 A / A 3.5 / 3.95 A / A 3.92 / 4.23 A / A 3.42/3.92 A / A 3.07 / 3.64 B / A 3.05 / 3.25 B / C 2.93 / 3.22 C / C Noise Level (sound pressure) (L / M / H) (6) (SP00) db(a) 27/29/29 28/30/30 29/31/31 32/35/37 33/35/38 33/36/39 51/54/54 25/55/55 Noise level (sound power) (8) (SP00) db(a) 55 56 57 62 65 66 77 78 Air flow cooling mode (L / M / H) m 3 /h 600/750 /960 780/960/1140 960/1140/1320 1500/1680/1800 1740/1920/2100 1800/1980/2160 3570/3960/3960 4056/4500/4500 Static Pressure Nom. (min ~ max) Pa 30 (0~120) 30 (0~125) 30 (0 125) 45 (0 120) 50 (0 140) 50 (0 140) 140 220 140 220 Dimensions (H x W x D) 275 x 1084 x 600 275x1084x600 275 x 1084 x 600 275 x 1474 x 600 275 x 1474 x 600 275 x 1474 x 600 423 x 1592 x 600 423 x 1592 x 600 Weight kg 35 36 48 85 87 Included Condensate Pump yes no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ32 φ32 φ25 φ25 1/4 / 5/8 3/8 / 3/4 6.35 / 15.88 9.53 / 19.05 Power Input w 60 150 250 1065 Power supply 230V / 1Ph / 50Hz Recoended fuse size A 5 10 Remote Controller PC ART (PCARF, infrared and simplified model optional) 3/8 / 7/8 9.53 / 22.2 OUTDOOR UNITS RAS 2HVNP1 RAS 2.5HVNP1 RAS 3HVNP1 RAS 4H(V)NP1E RAS 5H(V)NP1E RAS 6H(V)NP1E RAS 8HNPE RAS 10HNPE Power supply 230V / 1Ph / 50Hz (230V / 1Ph / 50Hz) 230V / 1Ph / 400V / 3Ph / 50Hz 50Hz 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode) (7) db(a) 44 (42) 45 (43) 46 (42) 47 (43) 48 (44) 48 (45) 57 (55) 58 (56) Noise level heating (sound pressure) (7) db(a) 46 47 48 49 50 50 59 60 Noise level (sound power) (8) db(a) 62 63 63 63 64 65 76 76 Air flow (Cooling / Heating) m 3 /h 2436 2436 2700 4800 5400 6000 7620 8040 Dimensions (H x W x D) 600 x 792 x 300 600 x 792 x 300 800 x 950 x 370 1380 x 950 x 370 1380 x 950 x 370 1380 x 950 x 370 1380 x 950 x 370 1380 x 950 x 370 Weight kg 43 43 66 103 103 103 136 138 Piping diameter (Liquid / Gas) 6.35 / 12.7 6.35 / 12.7 3/8 / 11/8 9.53 / 28.61 1/2 / 11/8 12.07 / 28.61 Minimum Piping Length m 5 5 5 5 5 5 5 5 Maximum Piping Length / Height Difference m 50 / 30 50 / 30 50 / 30 75 / 30 75 / 30 75 / 30 100 / 30 100 / 30 Current Quantity of Refrigerant kg 1.6 1.6 2.3 4.1 4.2 4.2 5.7 6.2 Chargeless / Additional Refrigerant Charge m / g/m 30 / 30 30 / 30 30 / 40 30 / 60 30 / 60 30 / 60 30 / Calculate 30 / Calculate Recoended fuse size 1Ph/3Ph A 16/ 20/ 20/ 32/16 32/16 32/16 /32 /32 Starting current (1Ph/3Ph) A <10 <10 <10 <10 <10 <10 <10 <10 Running current (cooling / heating) 1Ph (3Ph) A 5.1/4.9 (/) 5.4/5.7 (/) 6.4/6.7 (/) 8.7/8.9 (3.2/3.2) 13.7/12.8 (5.0/4.7) 17.3/15.9 (6.3/5.8) 8.6/8.1 12.6/11.3 Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~46(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Rotary Scroll Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Data calculated in accordance to pren14825 and the Coission Counication 2012/C 172/01 (5) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (6) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (7) Sound pressure level is measured at 1.0m from the unit front surface and 1.5m from floor level (Measured in an anechoic chamber) (8) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN12102 65

Ducted in the Ceiling UTOPIA IVX CENTRIFUGAL +21 15 +43 10 NEW RPI 5FSN4E PC ARF RPI 10FSN3E Indoor units Nominal cooling capacities 10.0kW to 25.0kW Nominal heating capacities 11.2kW to 28.0kW Possible to supply fresh air: Econofresh see pages 208209 Low consumption motor 4 speed, 3 static pressure levels, including zero pressure setting Easily accessible filters. PC ART Remote controllers Advanced PCARF wired LED controller (inc. 7day time clock) 5 time ranges with different temperatures (reduced, weekly, holiday etc) Service menu and optional function menus, add your contact details to be shown when there is an error Standard PCART wired remote controller (inc. 7day time clock) 4 prograable weekly schedules Service menu, optional function menu and fault diagnostic Alternative option: infrared or simplified remote control see pages 262263. RASC 410HNPE Outdoor units Only Utopia IVX centrifugal on the market Installed indoors with fieldsupplied ductwork ideal where external installation space is limited or planning restrictions apply Low temperature operation as standard Flexible inlet air and outlet air option for easy installation (excludes 5HP) Only 43cm high (5HP only) RPI 5FSN4E 66 More information on controls and options on pages 257272

UTOPIA IVX CENTRIFUGAL Ducted in the Ceiling INDOOR UNITS RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (min max) (1) kw 10 (4.5 11.2) 12.5 (5.7 14.0) 14.0 (6.0 16.0) 20.00 (8.00 22.40) 25.00 (10.00 28.00) Nominal Heating Capacity (min max) (2) kw 11.2 (5.0 14.0) 14.0 (5.0 16.0) 16.0 (5.0 18.0) 22.40 (6.30 28.00) 28.00 (8.00 35.00) UK Cooling Capacity (sensible) (3) kw 10.3 (7.9) 12.7 (9.1) 15.2 (10.5) 20.1 (15.5) 24.9 (17.9) Nominal Load Efficiency EER / COP (4) Energy Class (Cool/Heat) 3.35 / 3.8 A / A 3.14 / 3.4 B / C 2.75 / 2.7 D / E 2.7 / 3.2 D / D 2.66 / 3.05 D / D Noise Level (sound pressure) (L / M / H) (5) db(a) 32/35/37 33/35/38 33/36/39 51/54/54 52/55/55 Noise level (sound power) (6) db(a) 62 65 66 77 78 Air flow cooling mode (L / M / H) m 3 /h 1500/1680/1800 1740/1920/2100 1800/1980/2160 3570/3960/3960 4056 / 4500 / 4500 Static Pressure Nom. (min ~ max) Pa 45 (0 120) 50 (0 140) 50 (0 140) 140 220 140 220 Dimensions (H x W x D) 275x1474x600 275x1474x600 275x1474x600 423 x 1592 x 600 423 x 1592 x 600 Weight kg 48 48 48 85 87 Included Condensate Pump yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ25 φ25 3/8 / 3/4 9.53 / 19.05 Power Input w 250 250 250 1065 1065 Power supply 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 10 10 Remote Controller PC ART (PCARF, infrared and simplified model optional) 3/8 / 7/8 9.53 / 22.2 OUTDOOR UNITS RASC 4HNPE RASC 5HNPE RASC 6HNPE RASC 8HNPE RASC 10HNPE Power supply 400V / 3Ph / 50Hz Noise level cooling (sound pressure) (night mode )(5) db(a) 52 (48) 52 (48) 53 (49) 55 (51) 56 (52) Noise level heating (sound pressure) (5) db(a) 53 53 54 56 57 Noise level (sound power) (6) db(a) 70 71 72 74 75 Air flow (Cooling / Heating) m 3 /h 3300 3600 3600 6900 6900 Maximum External Static Pressure Pa 90 100 100 120 120 Dimensions (H x W x D) 555 x 1415 x 1015 555 x 1415 x 1015 555 x 1415 x 1015 620 x 1850 x 1360 620 x 1850 x 1360 Weight kg 192 192 192 300 303 Piping diameter (Liquid / Gas) 1/2 / 1 1/8 12.7 / 28.61 Minimum Piping Length m 5 5 5 5 5 Maximum Piping Length / Height Difference m 75 / 30 75 / 30 75 / 30 100 / 30 100 / 30 Current Quantity of Refrigerant kg 4.1 4.2 4.2 5.0 5.0 Chargeless / Additional Refrigerant Charge m / g/m 30 / 60 30 / 60 30 / 60 30 / Calculate 30 / Calculate Drain Diameter (ext) φ30 φ30 φ30 φ30 φ30 Recoended fuse size A 25 25 25 32 32 Starting current A <10 <10 <10 <10 <10 Running current (cooling / heating) A 4.8/4.7 6.4/6.6 8.2/9.2 11.9/11..2 14.5/13.7 Interconnecting Cables No. LNE + 2 core screened Working Range (cooling / heating) C 5ºC~46(db)ºC / 20(wb)ºC~15(wb)ºC Refrigerant / GWP R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 R410a / 1975 Compressor type Scroll Scroll Scroll Scroll Scroll System price includes PCART wired remote controller. (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Nominal load efficiency (Cooling 35 C/27 C, Heating 7 C/20 C) (5) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber) (6) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN12102 67

Indoor Units UTOPIA IVX DUCTED IN THE CEILING RPIM 0.8FSN4E(DU) RPIM 1.0FSN4E(DU) RPIM 1.5(1.3)FSN4E(DU) RPIM 1.5FSN4E RPI 0.8FSN4E RPI 1.0FSN4E Nominal Cooling Capacity (1) kw 2.0 2.5 3.0 3.6 2.0 2.5 Nominal Heating Capacity (2) kw 2.2 2.8 3.4 4.0 2.2 2.8 UK Cooling Capacity (sensible) (3) kw 2.1 (1.7) 2.6 (2.1 3.2 (2.3) 3.7 (2.6) 2.1 (1.7) 2.6 (2.1 Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 27/29/29 27/29/29 28/30/30 28/30/30 29/31/33 29/31/33 Noise level (sound power) (5) (SP00) db(a) 50 50 51 51 52 52 Air flow cooling mode (L / M / H) (SP00) m 3 /h 330/408/480 330/408/480 480 / 540 / 600 480 / 540 / 600 378/432/480 378/432/480 Static Pressure Nom. (min ~ max) Pa 32 (0~50) 32 (0~50) 27 (0~58) 27 (0~58) 32 (0~50) 32 (0~50) Dimensions (H x W x D) 275x702x600 275x702x600 275x702x600 275x702x600 197 x 1084 x 600 197 x 1084 x 600 Weight kg 26 26 26 26 29 29 Included Condensate Pump (DU model only) yes yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ25 φ25 φ25 φ25 φ25 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 Power Input W 30 30 30 40 30 30 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 5 5 RPI 1.5(1.3)FSN4E RPI 1.5FSN4E RPI 2.0(1.8)FSN4E RPI 2.0FSN4E RPI 2.5(2.3)FSN4E RPI 2.5FSN4E Nominal Cooling Capacity (1) kw 3.0 3.6 4.4 5.0 4.9 5.6 Nominal Heating Capacity (2) kw 3.4 4.0 5.0 5.6 5.6 6.3 UK Cooling Capacity (sensible) (3) kw 3.2 (2.3) 3.7 (2.7) 4.3 (3.3) 5.3 (4.0) 5.5 (4.1) 5.9 (4.5) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 29/31/34 29/31/34 27/29/29 27/29/29 28/30/30 28/30/30 Noise level (sound power) (5) (SP00) db(a) 53 53 55 55 56 56 Air flow cooling mode (L / M / H) (SP00) m 3 /h 480/540/600 480/540/600 780/900/960 780/900/960 900/1020/1140 900/1020/1140 Static Pressure Nom. (min ~ max) Pa 27 (0~50) 27 (0~50) 30 (0 120) 30 (0 120) 30 (0 140) 30 (0 140) Dimensions (H x W x D) 197x1084x600 197x1084x600 275x1084x600 275x1084x600 275x1084x600 275x1084x600 Weight kg 30 30 35 35 36 36 Included Condensate Pump (DU model only) yes yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ32 φ32 φ32 φ32 φ32 1/4 / 5/8 1/4 / 5/8 6.35 / 12.70 6.35 / 12.70 6.35 / 15.88 6.35 / 15.88 Power Input W 30 40 40 40 80 80 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 5 5 RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E RPI 8.0FSN3E RPI 10.0FSN3E Nominal Cooling Capacity (1) kw 7.1 10.0 12.5 14.0 20.0 25.0 Nominal Heating Capacity (2) kw 8.0 11.2 14.0 16.0 22.4 28.0 UK Cooling Capacity (sensible) (3) kw 7.7 (5.8) 10.6 (7.7) 13.2 (9.5) 15.7 (11.3) 21.1 (16.2) 26.1 (20.6) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 29/31/31 25/28/30 28/32/35 29/33/36 51/54/54 25/55/55 Noise level (sound power) (5) (SP00) db(a) 57 62 65 66 77 78 Air flow cooling mode (L / M / H) (SP00) m 3 /h 1020/1200/1320 1500/1680/1800 1680/1920/2100 1740/1980/2160 3600/3960/3960 4110/4500/4500 Static Pressure Nom. (min ~ max) Pa 30 (0 150) 45 (0 110) 50 (0 140) 50 (0 150) 180/220/220 180/220/220 Dimensions (H x W x D) 275x1084x600 275x1474x600 275x1474x600 275x1474x600 432x 1592x600 432x 1592x600 Weight kg 36 48 48 48 85 87 Included Condensate Pump (DU model only) yes yes yes yes no no Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ32 φ32 φ32 φ25 φ25 3/8 / 3/4 3/8 / 7/8 9.53 / 19.05 9.53 / 22.2 Power Input W 110 160 200 220 970 1060 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 10 10 (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 m below the unit with 1m of return air ducting and 2m of discharge ducting (without ceiling under the unit) (5) Sound power level is the Aweighted sound power level [db(a)] measured at standard rated conditions for the «cooling» mode operation in accordance to EN12102. 170 More information on controls and options on pages 257272

Set Free DUCTED IN THE CEILING LOW HEIGHT PC ARF New multifunction graphical remote control (see page 262) DC Inverter fan motors deliver up to 40% reduction in energy consumption compared to previous model Very low noise Unit height less than 200, particularly suitable for lowered ceilings Adjustable return air configuration Automatic drainage pump eliminates condensation build up. RPI 0.6~1.5FSN4E (Low height) DUCTED IN THE CEILING (LOW HEIGHT) RPI 0.6FSN4E RPI 0.8FSN4E RPI 1.0FSN4E RPI 1.5(1.3)FSN4E RPI 1.5FSN4E Nominal Cooling Capacity (1) kw 1.7 2.2 2.8 3.8 4.0 Nominal Heating Capacity (2) kw 1.9 2.5 3.2 4.2 4.8 UK Cooling Capacity (sensible) (3) kw 1.5 (1.2) 2.1 (1.7) 2.6 (2.1) 3.4 (2.4) 3.9 (2.8) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 27/30/32 29/31/33 29/31/33 29/31/34 29/31/34 Noise level (sound power) (SP00) db(a) 50 52 52 53 53 Air flow cooling mode (L / M / H) (SP00) m 3 /h 330/372/420 378/432/480 378/432/480 480/540/600 480/540/600 Static Pressure Nom. (min ~ max) Pa 20 (0~35) 32 (0~50) 32 (0~50) 27 (0~50) 27 (0~50) Dimensions (H x W x D) 197 x 1084 x 600 197 x 1084 x 600 197 x 1084 x 600 197 x 1084 x 600 197 x 1084 x 600 Weight kg 29 29 29 30 30 Included Condensate Pump (DU model only) yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ25 φ25 φ25 φ25 φ32 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 6.35 / 12.70 Power Input W 30 30 30 30 40 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 5 (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 metres below the unit (measured in anechoic room) 197

Set Free DUCTED IN THE CEILING STANDARD PC ARF New multifunction graphical remote control (see page 262) Adjustable static pressure depending on installation requirements Static pressure adjustment via remote controller RPI 2~6FSN4E (Standard) Builtin drain pump (excludes RPIFSN3E models) DUCTED IN THE CEILING (STANDARD) RPI 2.0(1.8)FSN4E RPI 2.0FSN4E RPI 2.5(2.3)FSN4E RPI 2.5FSN4E RPI 3.0FSN4E RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E Nominal Cooling Capacity (1) kw 5.2 5.6 6.7 7.1 8.0 11.2 14.0 16.0 Nominal Heating Capacity (2) kw 5.6 6.3 7.5 8.5 9.0 12.5 16.0 18.0 UK Cooling Capacity (sensible) (3) kw 4.5 (3.4) 5.2 (4.0 6.2 (4.7) 6.4 (4.9) 7.5 (5.6) 10.5 (7.7) 12.7 (9.1) 14.8 (10.7 Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 27/29/29 27/29/29 28/30/30 28/30/30 29/31/31 25/28/30 28/32/35 29/33/36 Noise level (sound power) (SP00) db(a) 55 56 57 62 65 66 Air flow cooling mode (L / M / H) (SP00) m 3 /h 780/900/960 900/1020/1140 1020/1200/1320 1500/1680/1800 1680/1920/2100 1740/1980/2160 Static Pressure Nom. (min ~ max) Pa 30 (0 120) 30 (0 140) 30 (0 150) 45 (0 110) 50 (0 140) 50 (0 150) Dimensions (H x W x D) 275 x 1084 x 600 275 x 1474 x 600 Weight kg 35 36 48 Included Condensate Pump (DU model only) yes yes yes yes yes yes yes yes Condensate Pump Lift 850 from the bottom edge of the unit Drain Diameter (ext) φ32 φ32 φ32 φ32 φ32 φ32 φ32 φ32 1/4 / 5/8 1/4 / 5/8 6.35 / 15.88 6.35 / 15.88 Power Input W 40 40 80 80 110 160 200 220 Power supply 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 5 5 5 5 5 (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 metres below the unit (measured in anechoic room) 198 More information on controls and options on pages 257272

Set Free DUCTED IN THE CEILING LARGE CAPACITY PC ARF New multifunction graphical remote control (see page 262) Adjustable static pressure depending on installation requirements Static pressure adjustment via remote controller RPI 8~10FSN3E (Large capacity) Builtin drain pump (excludes RPIFSN3E models) DUCTED IN THE CEILING (LARGE CAPACITY) RPI 8.0FSN3E RPI 10.0FSN3E RPI 16.0FSN3PE RPI 20.0FSN3PE Nominal Cooling Capacity (1) kw 22.4 28.0 45.0 56.0 Nominal Heating Capacity (2) kw 25.0 31.0 50.0 63.0 UK Cooling Capacity (sensible) (3) kw 18.4 (14.21) 22.9 (18.1) 36.8 (28.4) 45.8 (36.2) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 51/54/54 52/55/55 53//56 54//57 Noise level (sound power) (SP00) db(a) 77 78 79 80 Air flow cooling mode (L / M / H) (SP00) m 3 /h 3600/3960/3960 4110/4500/4500 7200//7920 8220//9000 Static Pressure Nom. (min ~ max) Pa 180/220/220 180/220/220 180//220 180//220 Dimensions (H x W x D) 432 x 1592 x 600 432 x 1592 x 600 846 x 1592 x 600 846 x 1592 x 600 Weight kg 85 87 171 175 Included Condensate Pump (DU model only) no no no no Condensate Pump Lift Drain Diameter (ext) φ25 φ25 2 x φ25 2 x φ25 3/8 / 3/4 3/8 / 7/8 2 x 3/8 / 3/4 2 x 3/8 / 7/8 9.53 / 19.05 9.53 / 22.2 2 x 9.53 / 19.05 2 x 9.53 / 22.2 Power Input W 1065 1065 2 x 1065 2 x 1065 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 10 10 25 25 (1) Cooling: Internal ambient 27 C db (19 C wb) Ambient 35 C (2) Heating: Internal ambient 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level measured at 1.5 metres below the unit (measured in anechoic room) 199

Ventilation ECONOFRESH Functions EF 4,5 & 6NE The Econofresh can be attached to the RPI size 4, 5 & 6 ducted units. Fresh and recycled air is controlled using a series of dampers It can also be connected to a CO2 sensor to ensure the air quality or use of a enthalpy probe The Econofresh kit can provide up to 100% fresh air and has the ability to provide free cooling when the outdoor temperature is below the indoor setting temperature Used in conjunction with Hitachi s RPI In the Ceiling unit Maintains the correct room temperature and provides fresh air, but also provides natural cooling therefore increasing energy savings. RAS 5 H(V)NP1E Outdoor units New DC inverter compressor for improved lowspeed and partload seasonal performance SCOP of up to 4.65 A+ rating and SEER of up to 6.82 A++ rating. Individual control of multiple indoor units in each zone Adjust temperature settings according to occupancy and external environmental conditions to save on energy. Reduced number of outdoor units and less pipework required. Cold draught prevention, frost protection and low noise as standard. RPI 4, 5 & 6FSN4E Indoor units Ultra low energy consumption Ultra quiet up to 27 db(a) 3 fan speeds 3 static pressure settings All models compatible with the UTOPIA IVX and SET FREE ranges Easily accessible filters. EF 5NE 208 More information on controls and options on pages 257272

Econofresh DUCTED INDOOR UNITS RPI 4.0FSN4E RPI 5.0FSN4E RPI 6.0FSN4E Nominal Cooling Capacity (min max) (1) kw 10 (4.5 11.2) 12.5 (5.7 14.0) 14.0 (6.0 16.0) Nominal Heating Capacity (min max) (2) kw 11.2 (5.0 14.0) 14.0 (5.0 16.0) 16.0 (5.0 18.0) UK Cooling Capacity (sensible) (3) kw 10.6 (8.2) 13.2 (9.5) 15.7 (10.8) Noise Level (sound pressure) (L / M / H) (4) (SP00) db(a) 25/28/30 28/32/35 29/33/36 Noise level (sound power) (SP00) db(a) 62 65 66 Air flow cooling mode (L / M / H) m 3 /h 1500/1680/1800 1680/1920/2100 1740/1980/2160 Static Pressure Nom. (min ~ max) Pa 45 (0 110) 50 (0 140) 50 (0 150) Dimensions (H x W x D) 275x1474x600 275x1474x600 275x1474x600 Weight kg 48 48 48 Included Condensate Pump yes yes yes Drain Diameter (ext) φ32 φ32 φ32 Power Input w 250 250 250 Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Recoended fuse size A 5 5 5 (1) Nominal Cooling: Internal temperature 27 C db (19 C wb) Ambient 35 C (2) Nominal Heating: Internal temperature 20 C Ambient 7 C db (6 C wb) (3) UK Cooling: Internal Temperature 23 C db (16 C wb) Ambient 30 C (4) Sound pressure level is measured at 1.5m below the unit (Measured in an anechoic chamber). ECONOFRESH KIT EF456NE Dimensions H x L x W 254x310x1350 Weight kg 12.5 Power Supply Fed From Indoor Unit Interconnecting Cables Supplied Remote Controller Type via Indoor Unit The Econofresh EF456NE is compatible with ES, IVX and Set Free Systems Data in table above is when used with IVX Premium. OPERATING PRINCIPLE 209