WaterWay Rainscreen Drainage Mats

Similar documents
CHAPTER 7: Building Systems ROOFING SYSTEMS

Building Envelope. Moisture Drainage & Ventilation Products from Keene Building Products.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Asphalt Shingle Application Requirements

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

GreenGuard Housewrap Installation Guide

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

GYPSUM BOARD AND PLASTER

Avoiding Air Barrier Pitfalls

application instructions

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

DELTA Premium Moisture Management Systems for Foundations.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

PART 1 GENERAL 1.1 SECTION INCLUDES

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Comment Form on Proposed Gut Rehabilitation Alternatives

Detached accessory structures that contain no conditioned floor area are exempt.

Residential Roofing Guide

K2 STONE NATURAL VENEER

Tundra Series Windows January 2016

LP OSB Sheathing & Structural 1 Sheathing

Sun Windows General Information Sun New Construction Window Installation Instructions

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Please read the entire document before purchasing and installing any of these products

The WANZ Guide to Window Installation

Ver. 2. Guide to. Inspecting Residential Brick Veneer

DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines

Fiberglas, Exterior Wall Thermal Insulation

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Most of my work is in exterior remediation, both as a builder. Adhered Concrete Masonry Veneer To avoid water damage, treat faux stone like stucco

Product Guide Specification

Window Installation Instructions

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

WATER MANAGEMENT PRODUCTS

SHINGLE APPLICATION GUIDE

SECTION STANDING SEAM METAL ROOFING

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

Manufactured Stone Veneer Installation Instructions

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Certification: Building Plans Examiner. Exam ID: B3

SECTION STANDING SEAM METAL ROOF

Discipline: Structural Issued

12.1 Schlüter -KERDI-BOARD

COMMERCIAL BUILDING APPLICATIONS

EcoTouch Insulation with PureFiber Technology

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Built to Last. Built for Beauty. Good. Solid. Logix. TM

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

INSTALLATION GUIDE. americanwick.com WICK (9425)

Atlas Roofing Corporation insulating sheathing

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

SECTION PREFORMED METAL STANDING SEAM ROOFING

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

Mark Cramer Inspection Services, Inc.

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Frequently Asked Questions LP SmartSide Siding, Trim, and Soffit

The WANZ Guide to Window Installation

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier

Figure 1A. Typical brick veneer installation over wood frame construction.

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

Renovating Your Basement

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

LAYING BLOCK AND BRICK

GigaCrete Specification PlasterMax

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

Transcription:

WaterWay Rainscreen Drainage Mats Section 07460 - Rainscreen Drainage Mat Stuc-O-Flex International, Inc. Part 1 General 1.1 SUMMARY: A. Section Includes: WaterWay Rainscreen Drainage Mat for Use in Sidewall Construction B. Related Sections: 1.2 SUBMITTALS: 1. Division 4 Section: Masonry Units (04 20 00), Stone 904 40 00) Masonry Veneer (04 70 00) 2. Division 6 Section: Rough Carpentry (06 10 00) Finish Carpentry (06 20 00) 3. Division 6 Section: Sheathing (06 16 00) 4. Division 7 Section: Wood Base Siding (07 46 23) 5. Division 7 Section: Exterior Insulation and Finish Systems (EIFS) (07 24 00) 6. Division 7 Section: Fiber-Reinforced Cementitious Panels (07 46 46) 7. Division 7 Section: Flexible Flashings (07 56 00) 8. Division 9 Section: Portland Cement Plaster (09 22 00) A. General: Provide submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures. B. Product Data: Submit manufacturer's product data sheets C. Details. Manufacturers detail drawings D. Samples: Submit minimum 6 x 6 samples for selection and/or verification. E. Warranty: Provide manufacturers sample warranty. 1.3 QUALITY ASSURANCE: A. Installer: Installer shall have no less than three years of experience with products similar to those specified. B. Mock-Ups: [Specify requirements for mock-up.] Subject to acceptance by owner / architect, mock-up may be retained as part of finish work. C Mock-up shall be retained at project location, used as basis of acceptance for completed work D. After project completion remove and properly dispose of. E. Pre-Installation Meetings: Conduct pre-installation meetings to verify project requirements, substrate conditions, construction documents, details and manufacturer s warranty requirements 1.4 DELIVERY, STORAGE & HANDLING: A. General: Comply with Division 1 Product Requirement Section B. Delivery: Deliver materials in manufacturer's original, unopened, undamaged rolls / pallets with identification labels intact and clearly visible C. Storage and Protection: Store materials protected from rain, direct sun light and exposure to harmful conditions. Extreme cold temperatures will result in firm material, store at temperatures above 40 degrees (if possible).

1.5 REFERENCES: A. Filter Fabric shall meet minimum performance criteria outlined below: 1.6 WARRANTY: Performance Testing: Boat Test ASTM D-779-03: H2O Vapor Transfer in 12 Minutes 96 Hours No Water Passed Through Membrane Water Vapor Transmission Test: ASTM E-96: Perm Rating Exceeds 247 Hydrostatic Pressure Test - AATCC 127: 10cm / 18 hours Acceptance Criteria AC-38 / Water Resistive Barriers: Passes section 4.2.2 Ponding Water Test A. Project Warranty: Refer to Conditions of the Contract for project warranty provisions. B. Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty document executed by authorized company official. Part 2 Products 2.1 RAINSCREEN DRAINAGE MAT: A. Manufacturer: Stuc-O-Flex International, Inc. 1. Contact: 17639 NE 67th Court, Redmond, WA 98052, phone: 800-305-1045; fax: 425-869-0107; E-mail: techservice@stucoflex.com; website: www.stucoflex.com B. [Rainscreen Drainage Mat with Moisture resistant filter fabric] including the following: [select product / products] C. Filter Fabric shall meet minimum performance criteria outlined below: Performance Testing: 1. Boat Test ASTM D-779-03: H2O Vapor Transfer in 12 Minutes 96 Hours No Water Passed Through Membrane 2. Water Vapor Transmission Test: ASTM E-96: Perm Rating Exceeds 247 3. Hydrostatic Pressure Test - AATCC 127: 10cm / 18 hours 4. Acceptance Criteria AC-38 / Water Resistive Barriers: Passes section 4.2.2 Ponding Water Test

1. WaterWay 3mm WaterWay 3mm is a nominal 1/8 inch / 3mm thick drainage product consisting of a polymer core of fused entangled filaments with a moisture resistant filter fabric bonded to the outer surface. WaterWay 3mm is designed for use with manufactured and natural stone, traditional and one coat stucco, EIFS, fiber-cement and wood based sidings, masonry, metal and other wall cladding materials. This rainscreen product provides an un-interrupted drainage path & ventilation for incidental moisture between exterior finish materials and wall sheathing. a. Core Material: Extruded Polymer Matrix. b. Fabric Material: Non-Woven Polypropylene Fiber c. Width: Core 58 " (140.0) Filter Fabric 62 (147.1cm) d. Length: 37' (12.3m). e. Thickness: 0.125" (3.0mm). f. Weight: 13 lb. / roll. 9.53 kg / roll 2. WaterWay 7mm WaterWay 7mm is a nominal 5/16 inch / 7mm thick drainage product consisting of a polymer core of fused entangled filaments with a moisture resistant filter fabric bonded to the outer surface. WaterWay 7mm is designed for use with manufactured and natural stone, traditional and one coat stucco, EIFS, fiber-cement and wood based sidings, masonry, metal and other wall cladding materials. This rainscreen product provides an un-interrupted drainage path & ventilation for incidental moisture between exterior finish materials and wall sheathing. a. Core Material: Extruded Polymer Matrix. b. Fabric Material: Non-Woven Polypropylene Fiber c. Width: Core 58 " (140.0) Filter Fabric 62 (147.1cm) d. Length: 37' (12.3m). e. Thickness: 0.30" (7.0mm). f. Weight: 16 lb. / roll. 7.2 kg / roll

3. WaterWay 11mm WaterWay 11mm is a revolutionary Vertical Wall Rainscreen consisting of a nominal 7/16 inch / 11mm thick extruded polymer matrix of tangled monofilaments. The monofilaments are heat laminated to a moisture resistant filter fabric with high perm rating on the outer side. WaterWay 11mm is designed for use with manufactured and natural stone, traditional and one coat stucco, EIFS, fiber-cement and wood based sidings, masonry, metal and other wall cladding materials. This rainscreen product provides an un-interrupted drainage path & ventilation space for incidental moisture between the sheathing and exterior wall claddings. * Meets Canadian Code Requirements * a. Core Material: Extruded Polymer Matrix b. Fabric Material: Non-Woven Polypropylene Fiber c. Width: Core 58 " (140.0) Filter Fabric 62 (147.1cm) d. Length: 37' (12.3m). e. Thickness: 0.43" (11.0mm). f. Weight: 25 lb. / roll. 11.36 kg / roll 4. WaterWay 19mm Description: WaterWay Rainscreen19mm is a 3/4 inch / 19 mm randomly oriented geometrically patterned drainage and ventilation mat. It is designed to eliminate moisture and moisture vapor in masonry applications and other siding applications. It is produced from an extruded polymer matrix of tangled monofilaments. The monofilaments are heat welded at the junctions to form a resilient structure that spaces siding away from the inner sheathing. The product is especially useful in masonry where a clear cavity is desired. Uses include manufactured and natural stone, traditional and one coat stucco, EIFS, fiber-cement and wood based sidings, masonry, metal and other wall cladding materials. a. Core Material: Extruded Polymer Matrix. b. Fabric Material: Non-Woven Geo-composite Fabric c. Width: 48 " (122 cm) d. Length: 50' (15.2m). e. Thickness: 0.75" (19.0mm). f. Weight: 32 lb/roll. 14.5 kgs/roll

2.2 PRODUCT SUBSTITUTIONS A. Substitutions: No substitutions permitted. 2.3 ACCESSORIES A. Provide the following accessories: 1. [Housewrap / Air barrier] [Building paper]: a. Material: [Specify material.]. b. Material Standard: [Specify material standard.]. c. Manufacturer: [Specify manufacturer.]. Part 3 Execution 2. Self adhering flashing a. Material: Therm-Flash / Butyl with reinforced foil film b. Manufacturer: Stuc-O-Flex International, Inc. c. Size: Nominal 20 mils by 4, 6, 9, & 12 inch by 100 foot rolls 3. Fasteners: a. Type: [Galvanized Roofing Nails] [Plastic Cap Nails] [Staples] b. Material: Corrosion protected steel c. Material Standard: [Specify material standard] d. Manufacturer: [Specify manufacturer] e. Size: Suitable for project application 3.1 MANUFACTURER'S INSTRUCTIONS A. Comply with the instructions and recommendations of the manufacturer. 3.2 EXAMINATION A. Site Verification of Conditions B. Verify that site conditions are acceptable and do not begin installation until substrates have been properly prepared. 1. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding 2. Do not proceed with installation until unacceptable conditions are corrected. 3.3 INSTALLATION A. Install sidewall sheathing material [Gypsum sheathing] [Oriented strand board] [Plywood] [Foam board] [Insert sheathing description.] over framing. B. Apply [Building paper] [Housewrap] [Fluid Applied Membrane}in compliance with manufacturer's instructions if required.

C. Install Rainscreen Drainage mat. 1. For horizontal application, work from bottom to top (For vertical applications work from a corner Wrap the building completely, butting tightly to all door and window casings, stopping at all wall ends. Install Drainage mat so that it lies flat against the wall /substrate. 2. If wall is designed as a venting wall, ends should be terminated at a furring strip of matching thickness to prevent air movement to adjoining wall. 3. At all window and door openings, cut tight to vertical part of window, door casings. Take care not to cut or damage waterproofing and weather barrier. 4. If finish cladding is Stucco, EIFS or Cultured Stone Veneer, at the bottom of the mat, place a foundation weep screed, a J weep hole termination bar or flashing with weeps. Weather barrier and mat should be placed over top of the back piece of the weep screed, termination bar or flashing to create the proper shingle and water management. 5. For other finish cladding, attach a 6" wide piece of insect screen material continuously along the bottom edge of the Drainage mat, 3" above bottom edge of the Drainage mat. Fold over outward facing surface of installed Drainage mat. Attach with a large head nail to hold screen in place until cladding is applied. For top vented walls follow a similar procedure at the top of the Drainage mat. 6. If wall is designed as a venting wall, at wall terminations, place a wood termination strip along the outside edge of each wall to create a wind dam for negative wind load. 7. Refer to manufacturers Installation Guide for Flashing Windows / Doors for additional detailing recommendations and instruction. YouTube rainscreen stucco assembly for general overview D. Install specified siding or cladding directly over WaterWay Rainscreen Mat in compliance with manufacturer's installation instructions. NOTE: Maximum exposure of WaterWay Rainscreen shall not exceed 30 days, prior to cladding installation. 3.4 PROTECTION A. Protect installed work from damage due to subsequent construction activity on the site.