1 Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products Driwall Rainscreen CAV-AIR-ATOR KeeneStone Cut KeedeLath Driwall Mortar Deflection Driwall Weep Screed Driwall Membrane (Flashing) Driwall CDR Vent Driwall Prefabricated Composite Drain Driwall Protection Board Resources & Education Moisture & ventilation are essential to proper construction. Keene Building Products has pioneered the use of entangled net products in walls, roofs & foundations to handle incidental moisture & create drying potential. These products work in walls, masonry buildings, foundation & plaza applications. They work to increase moisture drainage, ventilation & isolation in every facet of commercial & residential construction.
2 Moisture Ventilation & Drainage Commercial & Single Family Residential Driwall products provide you the solutions you need for a better moisture drainage & ventilation system. The Driwall product line includes: Full-wall rainscreen applications Mortar collection devices for masonry cavity walls Weep screeds A fiberglass lath Drainage & ventilation products for several different types of roofing applications Weep vents Commercial & Single Family Residential In recent years commercial & single family residential construction techniques have changed. Today, tightening the structures to prevent thermal leakage is a common practice. This can be attributed to the demand for energy efficiency. This change in the construction process has led to lower drying capacity, which has contributed to moisture problems. Commercial & Single Family Residential page 1
3 Driwall Raincreen Driwall Rainscreen is a drainage mat for exterior wall systems. The product eliminates incidental moisture problems in most exterior veneer applications. The full-wall entangled net product rolls over the weather-resistant barrier to separate it from the exterior veneer. The airspace that it creates increases airflow through the wall cavity, allowing the wall to breathe & stay dry. Depending on the size of the cavity desired, it may be specified from a 0.25 thickness to 0.75 thickness. Applications a a a a astucco a Thin stone or brick a Manufactured stone a Stone & brick masonry Lap siding Siding applications Benefits Prevents callbacks from moisture problems Increases ventilation Helps prevent mold Most effective way to drain & vent One product that can do it all Driwall Rainscreen page 2
4 Driwall Rainscreen Frequently Asked Questions What applications is Driwall Rainscreen used in? Driwall Rainscreen is used behind stucco, manufactured stone, thin natural stone or brick and siding to provide an assured airspace for drainage and ventilation. Why should Driwall Rainscreen be used instead of a dimpled or pleated house wrap product? The house wrap products do not provide an adequate gap between the cladding and the sheathing to break the capillary action of water droplets so that positive drainage can occur. Furthermore, these products do not provide enough open space for air to flow through the walls. Driwall Rainscreen provides a minimum of ¼ inch of airspace to allow moisture to drain down and out of the wall. The ¼ inch of open space allows air to flow through the wall to provide the ventilation that is necessary to dry out the sheathing and the exterior veneer. What is the process for installing Driwall Rainscreen? Driwall Rainscreen is installed over the weather resistant barrier after all flashing details have been completed. The product is cut Driwall Rainscreen FAQ page 3
5 to fit around all windows, doors, and other penetrations just as a weather resistant barrier would be installed. Driwall Rainscreen can be attached using cap nails, screws, or staples. The siding or the lath, scratch coat, and exterior veneer are then installed per the manufacturer s installation guidelines. How does the fabric on one side of the Driwall Rainscreen work? The fabric is a breathable, nonwoven fabric that faces away from the sheathing. It prevents plaster or debris from entering the designed airspace. The three-inch selvage edge of fabric is folded over the adjacent sections of Driwall Rainscreen and can also be folded over the top and bottom openings to serve as a bug screen. Do you have an Installation video for Driwall Rainscreen? Yes. Visit our Driwall Rainscreen product pages online to view or use your phone to scan here. Install Video. Driwall Rainscreen FAQ page 4
6 Moisture Ventilation & Drainage Building Envelope Products CAV-AIR-ATOR building products CAV-AIR-ATOR building products CAV-AIR-ATOR building p roducts CAV-AIR-ATOR building products CAV-AIR-ATOR building products Driwall CAV-AIR-ATOR building products C C C CAV-AIR-ATOR CAV-AIR-ATOR is a full wall drainage and ventilation mat for full brick or stone masonry walls. It prevents mortar from entering the cavity, clinging to wall ties, or blocking weep holes. The innovative design allows the 4 x16 panels to be extremely light and flexible so they can easily rest between the brick ties. Thicknesses include: 0.40 (10 mm), 0.75 (19 mm),1.0 (25.4 mm), & 1.75 (44 mm). Applications Brick a a a Stone a Schools, public works and institutional construction Residential applications for long-life construction For applications in which the useful life of the building is in excess of 50 years Benefits Creates a 96.5% void space in a masonry veneer cavity Unobstructed ventilation from top of wall to bottom weeps Lightweight pieces Filter cloth laminated to the front prevents all mortar from entering the cavity Springy design adjusts to varying cavity width CAV-AIR-ATOR page 5
7 KeeneStone Cut KeeneStone Cut products are designed to catch & hold mortar droppings while allowing moisture to pass through & drain out of the wall. The product suspends mortar droppings above the weep holes to prevent the drainage channels from becoming blocked or clogged. It is made from nylon & is designed to be 10.0-inches (25.4 cm) high with 7.0-inch (17.8 cm) KeeneStone cuts. It is 95% open to provide optimal drainage & ventilation to dry out the wall system. Benefits Guaranteed to stop moisture from clogging weep holes when properly installed Simple installation with no mechanical fasteners required Will not grow mold; prevents fungus and mildew Perfect width to suspend mortar droppings above weep holes, but below flashing connection to the interior wall Interior Wallboard Vapor Barrier (if req d) Insulation Exterior Sheathing on LGMF Water Resistant Barrier or Air Barrier Masonry Veneer Anchor on Self-Adhering Membrane Strip KeeneStone Cut Termination Tape (if req d) Masonry Veneer Driwall Weep Vents Metal Drip Edge Counter Flashing Concrete Foundation Through Wall Flashing KeeneStone Cut page 6
8 Moisture Ventilation & Drainage Building Envelope Products KeedeLath KeedeLath is a self-furring synthetic lath that is easier to install & a lighter alternative to self-furred metal lath. The unique patented design replaces old metal lath in a variety of wall applications. This lath is constructed of entangled nylon mono-filaments incorporated into a fiberglass grid. The technology creates an easy to handle, durable & non corroding reinforcement material. Applications a a astucco a Manufactured stone veneers Thin stone veneers Benefits Replaces traditional metal lath Lightweight & easy to handle Self-furring a a Nylon core is resistant to most known corrosive chemicals, including solvents Non-corroding Flexible & lays flat High-strength Creates mechanical bond Installs quicker than metal lath KeedeLath page 7
9 Driwall Mortar Deflection Driwall Mortar Deflection is a cavity wall protection device for masonry. In commercial & residential construction it is used at the base of the wall, where flashing is installed to keep the airspace clear of mortar & debris. Driwall Mortar Deflection will allow the weep holes to stay open & drain properly. It does not absorb water, & helps to prevent mold. Driwall Mortar Deflection is to 1.60 thick (9 to 41 mm), & sold in rolls that are 25 to 50 feet in length. Benefits Prevents callbacks from moisture problems Cavity drainage & protection of flashing in one product Guaranteed to stop moisture from clogging weep holes when properly installed Will not grow mold; prevents fungus & mildew Brick Driwall Weep Vent Driwall Mortar Deflection Flashing Weather-resistive barrier (WRB) Outer sheathing Insulation Gypsum wall board Concrete foundation Base plate Driwall Mortar Deflection page 8
10 Moisture Ventilation & Drainage Building Envelope Products Driwall Weep Screed Driwall Weep Screed is a flashing & weep that is used with a weather-resistant barrier, or building paper & Driwall Rainscreen. It provides a clean termination for stucco, manufactured stone & thin natural stone at the bottom of the wall. The unique V shape allows migration of moisture down the screed & away from the wall. As required by all major building codes & the International Building Code, Weep Screed is necessary at the bottom of all framed walls. Driwall Membrane (Flashing) Driwall Membrane is a self-adhering flashing & waterproofing membrane that provides an air & vapor barrier for full wall or flashing applications in masonry, wood, or gypsum construction. These highly adhesive membrane products insure air & vapor protection. It is impermeable to air, moisture vapor, & water & has excellent adhesion to concrete, galvanized metal, steel, plywood & gypsum. Driwall Membrane is highly resistant to punctures and tears & comes in two thicknesses: 40 mil & 60 mil. Driwall Weep Screed & Driwall Membrane page 9
11 Driwall CDR Vent (Complete Drained Roof) Driwall CDR Vent is a thick drainage & ventilation mat designed to eliminate moisture & moisture vapor in roofing & siding applications. It is produced from an extruded polymer matrix of tangled monofilaments. The mat forms a resilient structure that spaces siding & roofing away from the inner sheathing. It is useful in roofing applications: metal, cedar shingles & shakes. *Not recommended under asphalt or fiberglass shingles Benefits Drainage of excess moisture & ventilation in one product Lightweight & easy to handle Simple installation with mechanical staple hammer Polymer core resistant to most known corrosive chemicals, including solvents Wide rolls for fewer seams Core ABSORBS & RELEASES NO MOISTURE Insulation 5 Gypsum board 6 Vent 7 Gutter Roof Applications* 5 1 Ridge vent 2 Roofing underlayment 3 Driwall CDR Vent Driwall CDR Vent page 10
12 Moisture Ventilation & Drainage Building Envelope Products Driwall Prefabricated Composite Drain (PCD) Driwall Prefabricated Composite Drain products are drainage mats designed to eliminate hydrostatic pressure from behind foundation walls, retaining walls, planters, plaza decks, & balconies. The mat holds soil or concrete away from the wall or deck & keeps the drainage plane clear. When using Driwall Prefabricated Composite Drain, aggregate for drainage can be eliminated from the construction site. Applications Plazas, foundation walls & planters Balconies Bored rock tunnels with moisture flow Will protect soft membranes Green roofs Benefits Fire resistant Class A fire rated product Minimal deflection, & no creep or long-term degradation Provides a thin profile for tight construction assemblies Lightweight & easy to handle Driwall Prefabricated Composite Drain page 11
13 Driwall Protection Board Driwall Protection Board is a thick waterproofing protection & drainage mat. It is used AFTER applying the waterproofing membrane to exterior foundation walls to prevent damage when backfilling. The product provides great drainage around foundations while eliminating the need for expensive clean-free, draining backfill. After protecting our basements waterproofing, it is essential to drain the soil around your foundation. Protection Board does this by eliminating hydrostatic pressure. Its open structure provides room for ample drainage, & a non-woven fabric separates soil from the water, allowing the water to move away for the foundation through the drainage pipe. Benefits Tough & durable core that prevents damage to the waterproofing membrane High flow rate in excess of 10 gallons per minute Provides a thin profile for tight construction assemblies Flexible for easy installation Applications a a Residential foundation walls Driwall Protection Board page 12
14 Keene Building Products Building Envelope Products Product Name Thickness Length Area Driwall Rainscreen in./6.0 mm 65 ft. 260 sq. ft. Driwall Rainscreen 10 mm 0.40 in./10.9 mm 45 ft. 180 sq. ft. Driwall Rainscreen in./19.0 mm 50 ft. 200 sq. ft. CAV-AIR-ATOR in./10.0 mm 4 ft. CAV-AIR-ATOR in./19.0 mm 4 ft. CAV-AIR-ATOR in./25.4 mm 4 ft. CAV-AIR-ATOR in./44.0 mm 4 ft. KeeneStone Cut in./25.0 mm 4 ft. KeeneStone Cut in./50.0 mm 4 ft. KeedeLath 25 ft. 100 sq. ft. Driwall Mortar Deflection in./9.0 mm 50 ft. Driwall Mortar Deflection in./19.0 mm 50 ft. Driwall Mortar Deflection in./41.0 mm 25 ft. Driwall Weep Screed 0.08 in./2.0 mm 5 ft. Driwall Membrane 40 mil (Flashing) in./1.0 mm 75 ft. 300 sq. ft. Driwall Membrane 60 mil (Flashing) in./1.5 mm 67 ft. 268 sq. ft. Driwall CDR Vent 0.30 in./7.6 mm 60 ft. 240 sq. ft. Driwall PCD in./3.175 mm 100 ft. 400 sq. ft. Driwall PCD in./9.0 mm 100 ft. 400 sq. ft. Driwall PCD in./10.0 mm 100 ft. 400 sq. ft. Driwall PCD in./10.0 mm 100 ft. 400 sq. ft. Driwall PCD MEM 0.33 in./8.0 mm 75 ft. 300 sq. ft. Driwall Protection Board in./3.175 mm 50 ft. 200 sq. ft. Driwall Weep Vents in./9.0 mm (size: 2.5 in. x 3.5 in.) Resources & Education page 13
15 Keene can Help You Achieve LEED Credits LEED, or Leadership in Energy & Environmental Design, is a green building certification program that provides a national rating system for developing sustainable building designs and construction. LEED v4 BD+C (Building Design + Construction) MR Credit 3: 1-2 points (Material & Resources) Building Product Disclosure & Optimization - Sourcing of Raw Materials Locally sourced materials and recycled content are now combined in 2 options: 1. Raw Material Source and Extraction Reporting (1 point) 2. Leadership Extraction Practices (1 point) Recycled Pre-Consumer Post-Consumer Product Thickness Content Content Content Driwall 0.25 in. / 6.0 mm up to 40% 40% 0.40 in. / 10.9 mm up to 40% 40% 0.75 in. / 19.0 mm up to 40% 40% Resources & Education page 14
16 Receive AIA Continuing Education Credits from Keene Building Products Healthy Roofs = Drainage & Ventilation Healthy roofs stand the test of time because of two important attributes; drainage and ventilation. Moisture related issues in roof, and wall assemblies have contributed to a historic amount of damage and failures. This presentation focuses on the need, and benefits of a continuous drainage, and ventilation underlayment in several different types of roofing applications. It will also emphasize how each component of the roof work in conjunction with one another to alleviate any potential problems regarding moisture. Healthy Walls = Rainscreen & Ventilation The construction industry has seen a substantial increase in moisturerelated issues in exterior walls. This presentation will discuss how a rainscreen wall system prevents moisture build-up within walls by providing a means for drainage and ventilation. The presentation provides an overview of rainscreen principles and explains how to incorporate a rainscreen system in a variety of applications including stucco, manufactured stone, siding, and masonry cavity walls. Resources & Education page 15
17 Masonry Cavity Walls, the Original Rainscreen System This presentation discusses moisture management in a masonry cavity wall. It will emphasize the importance of maintaining an open airspace within the cavity for proper drainage and ventilation in the wall system. It will provide the means and methods of designing and constructing a clean, unobstructed cavity, which will provide energy efficiency and a better living environment. Solidifying your Foundation Below Grade Drainage & its Importance Building structures endure largely because of soundly constructed foundations, and the key to a healthy foundation is proper drainage. Historically, moisture has eroded foundations and caused structural failures. This presentation focuses on historical, current and future drainage systems, and their importance in building a sound structure. Call or TODAY to set up a lunch presentation [email protected] Keene Building Products is a registered provider with The American Institute of Architects Continuing Education Systems. Credit earned upon completion of this program will be reported to CES Records for AIA members. Credit includes Health, Safety, and Welfare (HSW) (1 Credit Hour). Certificates of Completion for non-aia members are available upon request. This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific material, methods and services will be addressed at the conclusion of this presentation. Resources & Education page 16
18 Project Profile Driwall Rainscreen Hotel Akron, OH This brand new contemporary four-story hotel is the first of its kind to open in the up and coming downtown Akron, Ohio area where many museums, restaurants and retail establishments reside. Guests can enjoy great amenities including an indoor pool and high-quality fitness center, all while feeling comfortable and relaxed during their stay. In order to make this hotel ideal for guests, appearance is a factor. Guests want to stay in new and modern hotels and that requires exterior buildings to look their best. The exterior veneer for this hotel was finished with manufactured stone. To prevent any exterior moisture issues, sustain the longevity of this hotel and to create a profitable asset, the wall design incorporated Keene Building Products Driwall Rainscreen drainage mat. Driwall Rainscreen provides an airspace between the sheathing and exterior veneer to allow for drainage and ventilation of the wall system. Resources & Education page 17
19 Driwall Rainscreen provides an airspace for any incidental moisture penetration that gets behind the stone, which occurs due to wind driven rain. Driwall Rainscreen allows for moisture to drain to the exterior. Driwall Rainscreen also provides ventilation. When the stone gets wet, it will have the capacity to properly dry. Draining and drying are two extremely important aspects for the proper life span of manufactured stone. Driwall Rainscreen provides that in one product. By including Driwall Rainscreen into this brand new hotel, the mason ensured that the manufactured stone can properly drain and ventilate. Now it is ready for guest to enjoy and stay comfortably. For more project profiles visit: Resources & Education page 18
20 Product info. SCAN Keene Building Products, all rights reserved. Printed in U.S.A. All logos/images are trademarks of Keene Building Products. Mayfield Hts., OH USA. P.O. Box Mayfield Heights, OH P F
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
Ver. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
Residential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group Since water intrusion is among the most damaging problems
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Comment Form on Proposed Gut Rehabilitation Alternatives
Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
Natural Thin Stone Veneer
Natural Thin Stone Veneer Until recently, if a project called for the natural look of stone but could not support its weight or thickness, the options were limited to manufactured imitation stone. More
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses
Chapter 9: INSTALLING ROOFING
9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines
DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines HELPING YOU GET THE JOB DONE RIGHT FOR BUILDINGS LESS THAN 5
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
Measure Guideline: Water Management at Tub and Shower Assemblies
Measure Guideline: Water Management at Tub and Shower Assemblies Bruce Dickson IBACOS, Inc. December 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States
Avoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
16 2 10.3 Materials and Colors
16 2 10.3 Materials and Colors To create a harmonious and coherent image for each development, building designs shall pay close attention to choice of materials and colors. Building construction shall
DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING
TECH TALK DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING DuPont offers six different DuPont Tyvek building wraps intended for use on a wide range of buildings from single family homes to high
STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope
FOUNDATIONS STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION Build a Better Home Details are critical when constructing a sound building foundation that will withstand water and control dampness.
EcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
K2 STONE NATURAL VENEER
INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In
Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort
bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls
A bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls CE 28 h Exterior finish materials are expected to protect the house from the elements while providing an attractive appearance.
Managing Moisture in Low-Rise Building Enclosures A Prescriptive Guide for Building Professionals on Proper Moisture Management Solutions.
Managing Moisture in Low-Rise Building Enclosures A Prescriptive Guide for Building Professionals on Proper Moisture Management Solutions. www.benjaminobdyke.com INTRODUCTION Increasingly, builders, contractors
Most of my work is in exterior remediation, both as a builder. Adhered Concrete Masonry Veneer To avoid water damage, treat faux stone like stucco
Best Practices Stone Veneer Adhered Concrete Masonry Veneer To avoid water damage, treat faux stone like stucco by mark parlee Photos: Mark Parlee Most of my work is in exterior remediation, both as a
Please read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
WATER MANAGEMENT PRODUCTS
WATER MANAGEMENT PRODUCTS ALSO AVAILABLE IN G D E A I B H F C A #15 Solid Leg* F #9 Transition Control Joint* B M-Slide Expansion Joint * G #6 Drip Head C J-Series Casing Bead H #17 Base Flashing* D #3
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
Peel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
application instructions
application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
The Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
Detached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.
Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.
Shingle Roofing: What s below the surface is important
What s below the surface is important The roof is leaking, the shingles look old, and the downspouts are dripping. It must be time to replace the roof or is it? Shingle roofs may seem simple, but a roof
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Housewrap Errors. By Steve Easley
Housewrap Errors By Steve Easley There Are Seven Common Mistakes Contractors Make When Installing Housewraps Green building and remodeling programs, the U.S. Environmental Protection Agency s IAQ Plus
Foundation. Foundation
Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
Epdm Flat Roofing Systems
Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and
LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council RETAINED ON U.S.
ICC-ES Legacy Report ER-5043* Reissued March 2004 www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code DIVISION: 09
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
Schluter -Shower System Installation Handbook 2014. Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds
Schluter -Shower System Installation Handbook 0 Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds Schluter -Shower System Bonded Waterproofing System for
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
State of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
INSTALLATION GUIDE. americanwick.com 800.242.WICK (9425)
INSTALLATION GUIDE americanwick.com 800.242.WICK (9425) American Wick Drain SITEDRAIN prefabricated drainage products may be installed in a variety of civil construction applications including: retaining
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
CHAPTER 8- REDUCING THE MOISTURE
CHAPTER 8- REDUCING THE MOISTURE I ve learned many different ways to cut down on moisture and dampness over my many years of being a homeowner. All those tips I ve included right here for you so that you
ROOFS - Guidance for Repair, Maintenance and Replacement
ROOFS - Guidance for Repair, Maintenance and Replacement Guilford Association Architectural Committee ROOFING Slate and tile roofs are a critical design feature of Guilford homes. The homes were designed
GYPSUM BOARD AND PLASTER
CHAPTER 25 GYPSUM BOARD AND PLASTER SECTION 2501 GENERAL 2501.1 Scope. 2501.1.1 General. Provisions of this chapter shall govern the materials, design, construction and quality of gypsum board, lath, gypsum
CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs
CertainTeed Self-Adhering Roof Systems for Low Slope Residential Roofs Goes down fast. Stays on strong. Flintlastic SA performs in all the right ways. What s more important to you? Speed of installation,
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing
Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Self-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
How to repair your existing low slope flat roof.
How to repair your existing low slope flat roof. Recycled Rubber Roofing is not a "Roof Coating." It is a liquid emulsion used as the underlayment of a new or retrofit, built-up roofing system. One of
Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick
Photo courtesy of Delta Stone, Heber City, UT Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick THIN VENEER INSTALLATION SYSTEMS PREMIUM BONDING MORTARS Premium PCL Stone
Manufactured Stone Veneer Installation Instructions
Manufactured Stone Veneer Installation Instructions Published: 8/14/2008 Revised: 6/25/2010 Table of Contents PART 1 -- INTRODUCTION PART 2 -- MATERIAL REQUIREMENTS PART 3 EXECUTION REQUIREMENTS PART 4
Built to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
ISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
Issue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
Atlas Roofing Corporation insulating sheathing
insulating sheathing Sales Offices Camp Hill, PA (800) 688-1476 Fax: (717) 975-6957 East Moline, IL (800) 677-1476 Fax: (309) 752-7127 Northglenn, CO (800) 288-1476 Fax: (303) 252-4417 LaGrange, GA (800)
Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open
Add Strength and Water Resistance When Repairing Your Walls Any home repair or remodeling work you do presents an opportunity to make your home fare better in the next storm. Whether you are just replacing
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed