APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Similar documents
How To Power A Bladecenter H Servers

Rack Systems Solutions

Rack Power Distribution

Rack Power Distribution. Worldwide

ADC-APC Integrated Cisco Data Center Solutions

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

PX100 MBP with Configurable Distribution

APC APPLICATION NOTE #92

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

APC 3Phase Power Distribution

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

Distributing Power to Blade Servers

Energy Management Solutions

How To Build A Cisco Uniden Computing System

APC APPLICATION NOTE #112

Cabinets 101: Configuring A Network Or Server Cabinet

Installation. Basic Rack Power Distribution Unit for Blade Servers

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Power Distribution Considerations for Data Center Racks

DCF Optimized Rack System Selection Guide

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Cabinet V800 V800 CABINETS

RACK ENCLOSURES & ACCESSORIES

Solutions for Small to Medium Data Centers

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Dell Smart-UPS 1,500 3,000 VA

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

High-Efficiency AC Power Distribution for Data Centers

InstaPATCH ZERO Solution Guide

Application Briefs: Remote Office Environment

Portable Energy Efficient Data Centre Solution

How To Build A T7 Rack For Information Technology

AU-110 racking guide NBXPN: 023

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Essential Rack System Requirements for Next Generation Data Centers

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Strategies for Deploying Blade Servers in Existing Data Centers

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

APC Step-Down Transformer. User s Manual

How To Fit A Dll 2420 And 4220 Rack Enclosure

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Case Study Nottingham Trent University

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Data Center Solutions - The Containerized Evolution

The Next Generation APC by Schneider Electric InfraStruxure

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Rack Power Distribution Unit For Critical IT Equipment

Optimizing Rack Power Distribution

Cheat Sheets to Data Center Infrastructure Management

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment

Cable management for rack-mounted systems

Airflow Simulation Solves Data Centre Cooling Problem

Server Technology, Inc.

Emerson Network Power Rack PDU Systems

DIGITUS Network & Server Cabinets. UNIQUE Series

SUN BLADE 6000 CHASSIS

Access Server Rack Cabinet Compatibility Guide

RACK ENCLOSURES AND OPEN FRAME RACKS FOR SERVER AND NETWORKING APPLICATIONS IN IT ENVIRONMENTS

Dynamic Power Variations in Data Centers and Network Rooms

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

42U/45U 28" Wide Rack Installation & Service Guide

Data Centre Solutions energy efficient by design

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling Guidelines for Deploying IT in Colocation Data Centers

The Pros and Cons of Modular Systems

Network-critical Physical Infrastructure (NCPI) Vulnerability Assessment

Dynamic Power Variations in Data Centers and Network Rooms

InstaPATCH Cu Cabling Solutions for Data Centers

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

Customized Server Cabinets

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Power to the adaptable data center

Power distribution in data centres

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

Unpacking, Installation, and Customization

Cooling Solutions. for the IT environment

Secure your IT equipment with confidence... secure with NetClosure

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Overload Protection in a Dual-Corded Data Center Environment

Case Study University of Aberdeen

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Increase the efficiency of power distribution in your high-density data center

Three-Phase Electric Power Distribution for Computer Data Centers

Cisco Nexus 7000 Series Power Supply Modules

Replacing a Dual Fan Unit on the GQAM Modulator

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Data Center Racks. Vantage S2. Enclosure System. Switch N to Eaton.

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Eaton epdu Data Center Product Catalog

Transcription:

APC by Schneider Electric Solutions for Unified Computing System (UCS) Blade Applications The Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a cohesive system designed to reduce TCO and increase business agility. The system integrates a low-latency, lossless 10GE unified network fabric with enterprise-class, x86-architecture servers. The system is an integrated, scalable, multi-chassis platform in which all resources participate in a unified management domain. Blade server applications present unique challenges in terms of rack level power distribution, cable management and physical access space requirements for hot-swappable blade components. This application guide provides recommendations for enclosures, rack power distribution, and cable management to best address the specific physical infrastructure needs of the Blade Server. The recommended solutions in this guide are based on physical verification and testing of an actual Blade Server mounted in APC enclosures.

APC Rack Enclosures and Rack Mount Power Distributions Units (PDUs) APC Advanced PDUs Integrates power management capabilities with other APC products including Symmetra PX UPS, row and room PDUs, InRow cooling, NetShelter SX enclosures, and InfraStruXure Central, Capacity and Change Manager Features zero U, low profile design, optimized for high-density rack power solutions to minimize interference between the PDU and hot-swap blade components Superior current monitoring protection including active monitoring of 3 phases for upstream panel breaker and on-board input breakers APC Full Featured Enclosures APC NetShelter SX enclosures offer the most standard, out-of-box features to ease installation and speed deployment Single enclosure design is flexible enough to accommodate various networking and server applications. Sizes Available: 42U & 48U heights, 600mm (24 ) & 750mm (30 ) widths, and 1070mm (42 ) & 10mm (47.2 ) depths. APC is a world leader in data center infrastructure - cooling, UPS, power distribution, racks and management.

Power Requirements for The Blade Server includes four, single phase, hotswappable redundant power supplies with IEC C Inlet connections. In a typical power configuration, two IEC C inlets on the are connected to each power source. Source A (2) C Connectors Source B (2) C Connectors The total power consumption per chassis for typical enterprise applications is 2.0 2.5 kw; while a typical peak power consumption is 2.8 3.0 kw. In order to allow for loss of one power source, each power source should be sized and provisioned for approximately 3.0kW per chassis loading scenario as indicated below. Rack Enclosures with up to two UCS 6100 Series Fabric Internconnects AND "A" Power Source Total Req'd Receptacles (per Source/Rack PDU) "B" Power Source Total Req'd Receptacles (per Source/Rack PDU) Total Power Provision Recommendation* (1) (2) C19, (2) C13 (2) C19, (2) C13 3.5 kw (2) (4) C19, (2) C13 (4) C19, (2) C13 6.5 kw (3) (6) C19, (2) C13 (6) C19, (2) C13 9.5 kw (4) (8) C19, (2) C13 (8) C19, (2) C13 12.5 kw (5) (10) C19, (2) C13 (10) C19, (2) C13 15.5 kw (6) (12) C19, (2) C13 (12) C19, (2) C13 18.5 kw * Each Rack Power Distribution Unit should be provisioned to this Total Power Provision Recommendation in order to account for potential source redundancy loss; Total Power Provision recommendations include power for up to two UCS 6100 Series Fabric Interconnects Note: High performance computing applications with extremely heavy loading conditions have been tested and measured to draw a peak power consumption of 3.2kW per chassis. Under these conditions, users should provision 3.2kW per chassis.

Rack PDU Selection Tables Steps to select the correct rack PDU to match site/application requirements: 1. Select your region; choose North America or International (for any location outside North America) 2. If North America, select 3-phase power system (8V 3-phase or 415V 3-phase) 3. Select the desired number of chassis per rack Table Results Indicate: Recommended total amps (single phase output) required to power the selected number of chassis plus up to two UCS 6100 Series Fabric Interconnects Recommended branch circuit type and size Recommended APC rack PDU (metered rack PDUs are recommended to actively monitor and provide alarm warnings to protect critical power circuits from accidental overloads) Total rack PDU rated output (total max single phase amps output) North America Solutions STEP 2 ----> STEP 3 ----> Max Power Required (kw)* Max Amps Required (1ph output)* Recommended Branch Circuit Rack PDU Model Total Rack PDU Rating (single phase amps) 415V 3-phase 1 to 3 2 to 5 6 1 to 3 9.5 15.5 18.5 9.5 45.7 74.5 88.9 39.6 50A, 3-phase 60A, 3-phase (2x) 50A, 3-ph A, 3-phase (1)AP7898 60A (12.5kW) 8V 3-phase Number of Blade per Enclosure (1)AP7866 or (1)AP7866A 77.9A (16.2kW) (2)AP7567A 138.6A (28.8kW) (1)AP7557NA 48A (11.5kW) * Total power and amps required includes power provision for up to two UCS 6100 Series Fabric Interconnects International Solutions (230/400V 3-phase Power) STEP 2 ----> STEP 3 ----> Max Power Required (kw)* Max Amps Required (1ph output)* Recommended Branch Circuit Rack PDU Model Total Rack PDU Rating (single phase amps) 400V 3-phase Number of Blade per Enclosure 1 to 3 4 to 6 9.5 18.5 41.3 80.4 16A, 3-phase 32A, 3-phase (1)AP7857 48A (11kW) (1)AP7856 or (1)AP7856A 96A (22kW) * Total power and amps required includes power provision for up to two UCS 6100 Series Fabric Interconnects

Rack Enclosure Recommendation The clearance access space required to access the hot swap blade chassis modules require special consideration in the selection and configuration of a proper rack enclosure to match the space requirements for access, power distribution, and data cabling. The specific selection of a properly sized rack enclosure depends upon your site specific data, cabling and rack power positioning preferences. Steps to select the correct enclosure to match site/application requirements: 1. Choose Region and Density: Select the number of chassis expected per enclosure 2. Choose enclosure width: Wider enclosures offer the best use of cable management space and access to blade modules, however site specific limitations may require standard 600mm width enclosure 3. Choose enclosure depth: Deeper enclosures are an alternative to wider enclosures for increased cable management and PDU space 4. Choose the Configuration: Reference the diagrams in this document for configuration recommendations and planning considerations 5. Choose Enclosure and Cable Management from the reference diagrams Step 1 Step 2 Step 3 Step 4 Choose Region & Density Choose Enclosure Width Choose Enclosure Depth Verify Configuration (as shown in diagrams) North America (1 to 5 chassis) 600mm wide (24 in) 750mm wide (30 in) 1070mm deep (~42 in) 10mm deep (~47 in) 1070mm deep (~42 in) 10mm deep (~47 in) Diagram A (note limited available space) Diagram B1 or B2 Diagram C1 or C2 Diagram C1 or C2 North America (6 chassis) 600mm wide (24 in) 750mm wide (30 in) 10mm deep (~47 in) 1070mm deep (~42 in) 10mm deep (~47 in) Diagram D Diagram E Diagram E International (1 to 6 chassis) 600mm wide (24 in) 750mm wide (30 in) 1070mm deep (~42 in) 10mm deep (~47 in) 1070mm deep (~42 in) 10mm deep (~47 in) Diagram A (note limited available space) Diagram B1 or B2 Diagram C1 or C2 Diagram C1 or C2

Diagram A 600mm wide x 1070mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) In this configuration, data cabling space is very limited; use AR8621 tool-less hook & loop cable managers and fasten to vertical mounting rails (small space cavity between the rack PDU and UCS chassis is shown in yellow) 1070 mm Place rack PDUs on each side of the enclosure with receptacles facing the rear door to allow access to hot swap blade components (outlet direction shown by arrow) 600 mm Use AR7711 bracket (one per side) to orient rack PDUs 90 (receptacles facing enclosure rear door) AP7866 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of blade server chassis 42U (AR3100) or 48U (AR3107) Bracket kit AR7711 (one per rack PDU) Cable management AR8621 (2 each) Power cords (C19 to C type)

Diagram B1 600mm wide x 10mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) In this configuration, data cabling space is abundant; users can select 1 to 3 cable management kits (AR7710) depending on expected volume of data cables. 10 mm Place rack PDUs as shown in this image to allow for hot swap ; note: PDUs cannot be located the opposite side due to interference with fan space 600 mm In this configuration, hot swap is tight, but has been tested to properly work. 42U (AR3300) or 48U (AR3307) Cable Management kit(s) AR7710 (order 1 to 3 units) AP7866 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of blade server chassis Power cords (C19 to C type)

Diagram B2 600mm wide x 10mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) In this configuration, data cabling space is abundant; users can select 1 or 2 cable management kits (AR7710) depending on expected volume of data cables. 10 mm Place rack PDUs on each side of the enclosure with receptacles facing the rear door to allow access to hot swap blade components (outlet direction shown by arrow) AP7866 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of blade server chassis 600 mm Use AR7711 bracket (one per side) to orient rack PDUs 90 (receptacles facing enclosure rear door) 42U (AR3300) or 48U (AR3307) Bracket kit AR771 (one per rack PDU) Cable Management kit(s) AR7710 (order 1 to 3 units) Power cords (C19 to C type)

Diagram C1 750mm wide x 1070mm and 10mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) Data cabling can be managed by use of either (1) AR7710 or (2)AR8442 (for more capacity) 1070 mm Rack PDUs can be placed on either side of rack enclosure 750 mm 10mm enclosure has additional space for access and cable management (can use additional AR8442 kits or AR7710 kits) 10 mm 1070mm: 42U (AR3150) or 48U (AR3157) 10mm: 42U (AR3350) or 48U (AR3357) Cable Management kit(s) 1070mm: either (1 or 2) AR8442 or (1) AR7710 10mm: either (1 to 3) AR7710 or (1 to 6) AR8442 AP7866 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of blade server chassis Power cords (C19 to C type)

Diagram C2 750mm wide x 1070mm and 10mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) Data cabling can be managed by use of AR8442 (1 or 2 units) 1070 mm Rack PDUs placed on both sides of the rack enclosure 750 mm 10mm enclosure has additional space for access and cable management (can use additional AR8442 kits or AR7710 kits) 10 mm AP7866 rack PDU shown in illustration; however, configuration would be common for any PDU selection and number of blade server chassis 1070mm: 42U (AR3150) or 48U (AR3157) 10mm: 42U (AR3350) or 48U (AR3357) Cable Management kit(s) 1070mm: either (1 or 2) AR8442 10mm: either (1 or 2) AR7710 or (1 to 6) AR8442 Power cords (C19 to C type)

Diagram D 600mm wide x 10mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) In this configuration, data cabling space is abundant; users can select 1 to 3 cable management kits (AR7710) depending on expected volume of data cables. 10 mm Place rack PDUs as shown in this image to allow for hot swap Note: PDUs cannot be located on the opposite side due to interference with fan component access space 600 mm 42U (AR3300) or 48U (AR3307) Cable Management kit(s) AR7710 (order 1 to 3 units) Power cords (C19 to C type) Space is extremely limited in this configuration; hot swap modules must be removed at an angle to avoid interference with PDU

Diagram E 750mm wide x 1070mm and 10mm deep Optional UCS 6100 Series Fabric Interconnects (can be positioned to customer preference) Data cabling can be managed by use of either (1) AR7710 or (2)AR8442 (for more capacity) 1070 mm Rack PDUs can be placed on either side of rack enclosure 10mm enclosure has additional space for access and cable management (can use additional AR8442 kits or AR7710 kits) 750 mm 10 mm PDUs are ½ enclosure height; place 4 units on the same rack side to reduce interference from incoming power cords 1070mm: 42U (AR3150) or 48U (AR3157) 10mm: 42U (AR3350) or 48U (AR3357) Cable Management kit(s) 1070mm: either (1 or 2) AR8442 10mm: either (1 to 3) AR7710 or (1 to 6) AR8442 Power cords (C19 to C type)

Cable Management Accessories AR8442 Toolless Vertical Cable Organizer AR7710 Toolless, Low-Profile Vertical Cable Organizer AR7711 Zero U Accessory Bracket AR8443A & AR8444 Fiber Spool Kits AR8621 Toolless Hook and Loop Cable Managers For more information visit: www.apc.com or www.thedcofthefuture.com Call APC at: 800-272-2722 AR7580 High Density Cable Manager (for wide racks) 09 American Power Conversion Corporation. All rights reserved. Other trademarks are property of their respective owners. Specifications are subject to change without notice. 132 Fairgrounds Rd. West Kingston, RI 02892 USA Call: 800-800-4APC Fax: 401-789-3710 e-mail: esupport@apc.com