Performance of Louver Fin Pattern as Extended Surface Used To Enhance Heat Transfer - A Review

Similar documents
HEAT TRANSFER ENHANCEMENT IN FIN AND TUBE HEAT EXCHANGER - A REVIEW

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert

International journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS

Review of Heat Transfer Parameters of Serrated Plate Fin Heat Exchanger for Different Materials

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

HEAT TRANSFER AUGMENTATION IN A PLATE-FIN HEAT EXCHANGER: A REVIEW

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT

Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli , Tamil Nadu, India

Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

ENHANCEMENT OF HEAT TRANSFER USING WIRE COIL INSERTS WITH CHORD RIBS

THE PSEUDO SINGLE ROW RADIATOR DESIGN

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.6, pp ,

EFFECT OF USE OF SWIRL FLOW DEVICES TO IMPROVE HEAT TRANSFER RATE IN HEAT EXCHANGERS

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Natural Convection. Buoyancy force

Corrugated Tubular Heat Exchangers

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

Heat Transfer Analysis of Cylindrical Perforated Fins in Staggered Arrangement

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

Enhancement of heat transfer of solar air heater roughened with circular transverse RIB

Battery Thermal Management System Design Modeling

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

NUMERICAL SIMULATION OF GAS TURBINE BLADE COOLING FOR ENHANCEMENT OF HEAT TRANSFER OF THE BLADE TIP

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Experiment (13): Flow channel

FLUID FLOW Introduction General Description

Optimum fin spacing for fan-cooled heat sinks

FREE CONVECTION FROM OPTIMUM SINUSOIDAL SURFACE EXPOSED TO VERTICAL VIBRATIONS

Theoretical and Experimental Investigation of Heat Transfer Characteristics through a Rectangular Microchannel Heat Sink

Experimental Investigation on Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Pipe using internal threads of varying depth

Dependency of heat transfer rate on the Brinkman number in microchannels

International Journal of Food Engineering

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

Experimental Evaluation Of The Frost Formation

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

CFD Analysis of a butterfly valve in a compressible fluid

The Effect of Mass Flow Rate on the Enhanced Heat Transfer Charactristics in A Corrugated Plate Type Heat Exchanger

Study on Drag Coefficient for the Flow Past a Cylinder

CFD ANALYSES OF FLUID FLOW AND HEAT TRANSFER IN PATTERNED ROLL-BONDED ALUMINIUM PLATE RADIATORS

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

An Experimenatl Study on Heat Transfer Behaviors of A Welded - Aluminum Minichannel Heat Exchanger

PRESSURE DROP STUDIES IN WAVY CORRUGATED PLATE HEAT EXCHANGERS

EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE COLLAR PRODUCTION ON THE PIERCED FLAT SHEET METAL USING LASER FORMING PROCESS

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

PRESSURE DROP ANALYSIS OF INLET PIPE WITH REDUCER AND WITHOUT REDUCER USING CFD ANALYSIS

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

Open channel flow Basic principle

Averaging Pitot Tubes; Fact and Fiction

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

5.2. Vaporizers - Types and Usage

Including Material Cost and Strength Constraints in Heat Exchanger Design

Using CFD to improve the design of a circulating water channel

University Turbine Systems Research 2012 Fellowship Program Final Report. Prepared for: General Electric Company

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Basic Equations, Boundary Conditions and Dimensionless Parameters

Sizing of triple concentric pipe heat exchanger

Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations

Dr.A.K.Shaik Dawood. N.V.Kamalesh. Department of Mechanical Engineering, Associate Professor, Karpagam University, Coimbatore , India.

EXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT

How To Design A 3D Print In Metal

cmn_lecture.2 CAD OF DOUBLE PIPE HEAT EXCHANGERS

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

EXPERIMENTAL STUDIES ON PRESSURE DROP IN A SINUSOIDAL PLATE HEAT EXCHANGER: EFFECT OF CORRUGATION ANGLE

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

AIR STREAMS IN BUILDING FOR BROILERS

Solid shape molding is not desired in injection molding due to following reasons.

What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)

Comparing naturally cooled horizontal baseplate heat sinks with vertical baseplate heat sinks

Natural Convective Heat Transfer from Inclined Narrow Plates

Comparative Analysis of Gas Turbine Blades with and without Turbulators

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

STUDY ON HEAT TRANSFER AREA OF A PLATE-FIN HEAT EXCHANGER WITH WAVY SURFACES

MAXIMISING THE HEAT TRANSFER THROUGH FINS USING CFD AS A TOOL

Experiment 3 Pipe Friction

Application of CFD Simulation in the Design of a Parabolic Winglet on NACA 2412

Integration of a fin experiment into the undergraduate heat transfer laboratory

NUMERICAL INVESTIGATIONS ON HEAT TRANSFER IN FALLING FILMS AROUND TURBULENCE WIRES

Chapter 8: Flow in Pipes

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

An experimental investigation of heat transfer of free convection on triangular fins in order to optimize the arrangement of fins

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Correlations for Convective Heat Transfer

Exergy Analysis of a Water Heat Storage Tank

EXPERIMENTAL ANALYSIS OF PARTIAL AND FULLY CHARGED THERMAL STRATIFIED HOT WATER STORAGE TANKS

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach

Transcription:

RESEARCH ARTICLE OPEN ACCESS Performance of Louver Fin Pattern as Extended Surface Used To Enhance Heat Transfer - A Review Vinayak S. Powar*, Prof. M. M. Mirza** *(Department of Mechanical Engineering, RIT, Islampur, India) ** (Department of Mechanical Engineering, RIT, Islampur, India) ABSTRACT Enhancing heat transfer surfaces are used in many engineering applications such as heat exchangers, refrigeration and air conditioning systems, chemical reactors and automobile radiators. Hence many enhancing extended fin patterns are developed and used. Louver fin pattern is one of the advanced extended fin surface which used to enhance heat transfer coefficient with decrease in size, weight and cost of heat exchanger. This paper reviews experimental and numerical work brought by researchers on louver fin pattern to augments the overall thermal-hydraulic airside performance of heat exchangers. Numerous works are available for louver fin pattern to visualize flow, optimizing geometrical parameters of louvers, comparison study with different extended surfaces. The available work is in experimental form as well as numerical form performed by computational fluid dynamics. Researchers have given thermal-hydraulic performance of louver fin heat exchangers with different correlation techniques. Keywords Correlation, Louver Fin, Thermal-Hydraulic Performance. I. INTRODUCTION Researches are carried out for improving performance of heat exchangers having high degree of surface compactness and optimum overall thermalhydraulic performance. In a gas to fluid heat exchanger the thermal resistance is dominant on gas side and is up to 80% [5] to that of total thermal resistance in a heat exchanger. The main reason of lower thermal performance on gas side is due to 10 to 50 [5] times smaller heat transfer coefficient of gas than that of fluid. Hence a wide scope is available to enhance gas side heat transfer coefficient by some techniques. 1.1 Enhancement Techniques The heat transfer enhancement techniques can separate into two categories. One is Active Technique which requires external power source to enhance heat transfer like application of electromagnetic field and surface vibration. The other one is Passive Technique which requires no direct application of external power. It employs special surface geometries or fluid additives to enhance heat transfer. Passive technique is economical and widely used heat transfer enhancement technique. The heat transfer rate in heat exchanger is given by equation as Q = h A θ m..(1) Where h is heat transfer coefficient, A is effective heat transfer surface area and θ m is mean value of temperature difference. The use of passive technique to enhance heat transfer with considering the heat transfer equation (1) is in following manners. 1. Increase the effective heat transfer surface area A per unit volume without appreciably changing heat transfer coefficient h e.g. uses of plain fin surface. 2. Increase heat transfer coefficient h without appreciable changing area A by using special shapes like wavy or corrugated fins. That fin provides mixing due to secondary flows and boundary layer separation within channel. 3. Increase both h and A e.g. interrupting fins like louvers. These surfaces increase effective surface area and enhance heat transfer by repeated growth and destruction of boundary layers. 1.2 Louver Fin Pattern Louver fin pattern is one of the most advanced enhanced extended surfaces which are essentially formed by cutting the sheet metal of the fin at intervals and rotating the strips of metal so formed out of the fin. Fig.1 shows geometrical definition of heat exchanger with louver fins. 1409 P a g e

based on outer tube diameter, also larger f and j factors are found for the louver fin heat exchangers than others. For plate fin heat exchangers, the f and j factors increase with the decrease in the fin pitch. But for louver fin heat exchangers, the effects of fin pitch on the f and j factors do not show a trend. A larger pressure drop has found for a heat exchanger with a greater tube row number, also pressure drop decreases with the increase in the fin pitch. But for heat transfer coefficient h, the effects of the tube row number on h shows an insignificant influence. At a fixed fan power, a better heat transfer coefficient h is found for a heat exchanger with a lower tube row number. In addition, the louver fin surface shows the largest h among various fin surfaces. This means the louver fin is relatively most advantageous when used at the same operating condition. Figure 1: Typical louver fin pattern [7] 2.2 Jin-Sheng Leu et al. [2] have numerically investigated the air side performance of fin and tube heat exchangers having circular and oval tube configuration. The geometrical parameters of louver angle, louver pitch and louver length have tested. Fig. 2 shows a tested louver fin pattern having circular tubes. Louver fin has geometrical parameters like louver pitch, louver height, louver depth, louver angle, number of louvers, number of louver regions. By customizing that parameters different combinations of louver patterns can be developed such as symmetric, asymmetric, multi region, inclined, convex shaped and so many. The enhancing heat transfer is depends on geometrical parameters of louver fins hence researches are going on optimizing thermo-hydraulic performance of heat exchanger with respect geometrical parameters of louver. II. RELATED WORK The work available to examine performance of louver pattern is in experimental as well as numerical form performed by computational fluid dynamics. Due to involvement of large geometrical parameters experimental studies are time consuming and costly for testing and optimize performance of louver fin at various combinations of its geometrical and flow parameters so the trend is to use numerical studies for the same. Here both experimental and numerical studies are explained with result evaluation techniques. 2.1 Wei-Mon Yan et al. [1] have performed an experimental study to investigate the heat transfer and pressure drop characteristics of Fin and tube exchangers with plate, wavy and louvered fin surfaces. He has tested 12 plate fins, 12 wavy fin and 12 louvered fin geometries and results are presented as plots of friction factor f and Colburn factor j against Reynolds number in the range 300-2000. Both f and j factors decrease with increasing Reynolds number Figure 2: Circular tube louver fin pattern The validation of numerical results has done with experimental results obtained from literature of louver tube geometry having circular tube. It is found that the average Nusselt number and heat transfer coefficient overestimated by 20% than experimental results. The numerical results have compared between circular tube and oval tube with both have same perimeter. It is found that the heat transfer coefficient for oval tube is less than its circular tube counterpart by approximately by 10 % and the pressure drop for circular tube exceeds by 41% than oval tube configuration. It is seen that pressure drop increase with louver angle for all three louver pitches (L p =3.75, 2.68, 2.08 mm) at Reynolds number 149.4 and smaller louver pitch results in better heat transfer. It is seen that both average nusselt number and pressure drop for three different louver length (6.25, 7.34, 8.37mm), louver angle 14º and Reynolds number 149.9 increases with increase of louver length. 1410 P a g e

2.3 Man-Hoe Kim et al. [3] have performed experimental study on the air-side heat transfer and pressure drop characteristics for multi-louvered fin and flat tube heat exchangers. He has tested 45 heat exchangers with different louver angles (15º to 29º), fin pitches (1.0, 1.2, 1.4 mm) and flow depths (16, 20, 24 mm), for the air-side Reynolds numbers of 100 600. The air-side thermal performance data has analyzed using effectiveness- NTU method for crossflow heat exchanger. The heat transfer coefficient and pressure drop data for heat exchangers with different geometrical configurations has reported in terms of Colburn j-factor and Fanning friction factor f, as functions of Reynolds number based on louver pitch. Pressure drops increase with flow depth and air velocity, while the heat transfer coefficients decrease with flow depth and increase with face velocity. Pressure drops for all flow depths increase with louver angle, while the effect of louver angle on the heat transfer coefficients depends on flow depth. For 16 mm flow depth, heat transfer coefficients do not change much with louver angle. On the other hand, for 24 mm flow depth, heat transfer coefficients increase with louver angle and maximum at 27º, and again decrease with louver angle. Friction factors increase with louver angle, the j factor increases with louver angle, but its effect on the j factor varies with flow depth. It is found that at Reynolds number 1075, the temperature gradient is more pronounced for larger louver angle that is the higher heat transfer performance for large louver angle. However, a larger louver angle would also contribute to the increase in the pressure drop. It is also found that the temperature gradient is higher for successively variable louver angles than uniform angle. It is also seen that both Nusselt number Nu and pressure drop coefficient Cp for successively variable louver angles (cases A D) are higher than those for the uniform louver angle (case E). It is seen that boundary layers exist on both the upper and lower surfaces of the louvers at Reynolds number 1075. The relevant heat transfer enhancement is due to thinner boundary layers that form at the leading edge of each louver. The present results indicated the successively variable louver angle patterns applied in heat exchangers could effectively enhance the heat transfer performance. 2.5 V. P. Malapure et al. [5] has performed numerical simulation of single and double row tubes with louvered fins. The air side performance of heat exchanger is evaluated by calculating Stanton number and friction factor for different geometries with varying louver pitch, louver angle, fin pitch and tube pitch with different Reynolds number. Fig. 4 shows computational domain used in numerical study. 2.4 Ching-Tsun Hsieh et al. [4] have performed 3-D thermal-hydraulic analysis of louver fin heat exchangers with variable louver angle. He has tested five models (A-E) having successively increased or decreased louver angle patterns. Fig. 3 shows case models of tested heat exchangers. The heat transfer and pressure drop characteristics for different models interpreted by Colburn factor j and friction factor f. Figure 4: Computational domain louver fins Figure 3: Different case models of heat exchanger He has found that at low Reynolds number most of air flows through gap between the fins rather than through the louvers. The reason is that at low Reynolds number air has low kinetic energy so air finds path of least resistance so flow becomes duct directed rather louver directed and the heat transfer performance of fin is poor at low Reynolds number. At higher Reynolds numbers, the boundary layers around the louvers are thinner and the flow is nearly aligned with the louvers. Hence the heat transfer rate is increased with Reynolds number. By observing temperature variation across the middle of the upstream and downstream of the fin it is found that the temperature of the fin decreases with the distance from the tube surface, increasing tube pitch and increasing Reynolds number. Heat transfer and pressure drop 1411 P a g e

characteristics are presented in terms of nondimensional parameters, Stanton number (St) and friction factor (f ) as functions of Reynolds number. There is Close agreement is found between the computational results and experimental data at intermediate and high Reynolds number. However, at low Reynolds number there is a large deviation. The local Nusselt number on the top surface of each louver in the flow direction along the length of fin for Reynolds number Red = 1000 is obtained, high Nusselt number is obtained at the tip of the fin, leading edge and trailing edge of each louver. He has found that heat transfer coefficient increases with louver angle and reaches maximum value at 28 29 and then again decreases with the increase in louver angle for fin pitch 2.17 mm also higher heat transfer coefficient is obtained at smaller louver pitch, i.e., L p = 0.81 mm at optimum louver angle. By decreasing the fin pitch from 3.33 mm to 2.11 mm, heat transfer rate increases. However further reduction in fin pitch does not result in any additional improvement in heat transfer 2.6 Wei Li et al. [6] have performed an experimental study on air-side heat transfer and pressure drop characteristics of heat exchangers with multi-region louver fins and flat tubes with Reynolds numbers of 400 1600 based on the louver pitch. Fig. 5 shows seven kinds of samples of heat exchangers with different number of louver regions (0 to 6) and fin louver heights were tested. The performance data were analyzed by using the effectiveness-ntu method also thermal-hydraulic characteristics of heat exchanger presented in terms of the Colburn j factor and Fanning friction f factor as function of the Reynolds number. The j factor and f factor tend to decrease with an increasing Reynolds number and tend to increase with the increased number of louver regions. The cause is that with the increased number of louver regions, the louver area of the fin increases. The results show that the 4-region louver fin and the 6-region louver fin are better than the traditional fin in overall thermal hydraulic performance and that the 6- region louver fin is even better than the 4-region louver fin 2.7 A. Vaisi et al. [7] have performed experimental study on automobile radiator to investigate air side heat transfer and pressure drop characteristics of flow over louvered fins. He performed tests for asymmetrical and symmetrical arrangements of louvers which shown in Fig. 6 and 7 respectively. A thermalhydraulic performance of radiator has examined for various geometrical and flow parameters and experimental results compared with effectiveness-ntu results. Figure 6: Asymmetrical arrangement of louvers Figure 7: Symmetrical arrangement of louvers Figure 5: Multi region louver fin patterns He has used seven different inlet air velocities on both louver arrangements. He found that heat transfer rate tends to increase with an increasing inlet air velocity but at same velocity the symmetrical pattern has the higher heat transfer rate than asymmetrical. The reason is that symmetrical pattern has more louvers per tube and more the number of louvers with short pitch are the more the common areas between the fluid flows. By increasing air velocity the pressure drop in air side will be increased but the symmetrical pattern louvered fin behaves better in pressure drop performance. In the same conditions of temperature and mass flow rates for inlet air and 1412 P a g e

water, the cooling rate of outlet water and heating rate of outlet air temperature of symmetrical pattern is greater than asymmetrical one. The overall conclusion obtained from above work is that symmetrical louver fin arrangement found best in thermal-hydraulic performance than asymmetrical arrangement hence it is essential to consider geometrical parameters and physical structure of heat exchanger in order optimize performance. 2.8 Hui Han et al. [8] have numerically investigated fluid flow and heat transfer characteristics of finned tube heat exchanger. He has tested six models of heat exchanger containing oval tube having major axis 11.01 mm and minor axis 4.94 mm, big circular tube having same perimeter that of oval tube and diameter of 8.8 mm, and small circular tube having same hydraulic diameter that of oval tube and diameter of 6.18 mm. the fin patterns used are louver and wavy. Fig. 8 shows tested models. Figure 8: Test models The results shows that oval tube fins shows better heat transfer and lower pressure drop compared to big and small circular tube fins. The heat transfer coefficient of louver fin and oval tube increased by 3.2-6.6% and 26.0-28.4% also pressure drop decreased by 22.0% to 31.8% and 1.8% to 3.5% compared to big and small circular tubes. It is seen that Oval tubes can significantly improve the fin surface temperature distribution along the flow direction, making the temperature distribution more uniform, thereby improving the fin efficiency. III. CONCLUSION Different kinds of louver patterns have tested by researchers through its experimental and numerical studies. The heat transfer coefficient and pressure drop are two important characteristics used to optimize thermal-hydraulic performance of louver fin heat exchanger. Optimum heat exchanger bears maximum heat transfer coefficient and minimum pressure drop characteristics. The effects of various geometrical parameters such as louver pitch, louver regions, louver angle, louver numbers, louver height and flow parameters like air velocities are studied on performance of louver fin heat exchanger. Although To find an optimum louver fin heat exchanger for suitable application considering various parameters is cumbersome. REFERENCES [1] Wei-Mon Yan and Pay-Jen Sheen, Heat transfer and friction characteristics of fin and tube heat exchangers, International Journal of Heat and Mass Transfer, 43, 2000, 1651-1659. [2] Jin-Sheng Leu, Min-Sheng Liu, Jane-Sunn Lia and Chi-Chuan Wang, A numerical investigation of louvered fin and tube heat exchangers having circular and oval tube configurations, International Journal of Heat and Mass Transfer, 44, 2001, 4235-4243. [3] Man-Hoe Kim and Clark W Bullard, Air-side thermal hydraulic performance of multi louvered fin aluminum heat exchangers, International Journal of Refrigeration, 25, 2002, 390-400. [4] Ching-Tsun Hsieh and Jiin-Yuh Jang, 3-D thermal- hydraulic analysis for louver fin heat exchangers with variable louver angle, Applied Thermal Engineering, 26, 2006, 1629-1639. [5] V P Malapure, Sushanta K Mitra, A Bhattacharya, Numerical investigation of fluid flow and heat transfer over louvered fins in compact heat exchanger, International Journal of Thermal Sciences, 46, 2007, 199 211. [6] Wei Li and Xialing Wang, Heat transfer and pressure drop correlations for compact heat exchangers with multi-region louver fins, International Journal of Heat and Mass Transfer, 53, 2010, 2955-2962. [7] A Vaisi, M Esmaeilpour and H. Taheria, Experimental investigation of geometry effects on the performance of a compact louvered heat exchanger, Applied Thermal Engineering 31, 2011, 3337-3346. [8] Hui Han, Ya-Ling He, Yin-Shin Li, Yu Wang and Ming Wu, A numerical study on compact enhanced fin and tube heat exchangers with oval and circular tube configurations, International Journal of Heat and Mass Transfer, 65, 2013, 686-695. 1413 P a g e