Mount, assemble. Is responsible. Assembly Manufacturer (panelbuilder) > Routine verification 100%

Similar documents
IEC & 2 standard. The reference for safe and reliable LV switchboards

P System Cubicles. Certified for more safety

Securing your electrical installations Prisma,

Unified requirements for systems with voltages above 1 kv up to 15 kv

Easily connect your switchboards to facility management solutions

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

SURGE PROTECTIVE DEVICES

know-how Giant in distributing electricity for industry Prisma GK

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

IEC specifications for LV assembly switchboards

FAQs-Main switchboard design criteria

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

An Alternative Approach to Improving SAIDI and SAIFI Indicators

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Comparative study for cables and busbars

INTERNATIONAL STANDARD

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Advantages of Fixed Circuit Breaker Switchgear

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

RM4TG20 three-phase network control relay RM4-T - range V

The power distribution board that sets new standards

Safety technique. Emergency stop module BO 5988 safemaster

CompactLogix Power Supplies Specifications

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

More than just OK. Okken: Low voltage switchboard for electrical distribution and motor control

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Technicaldata General

Guide to the electrical parameter classifications of IEC and IEC safety standards

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

MV vacuum circuit breaker Evolis. When trust guides your steps

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Current distribution Comb busbars for Declic and SFT residential devices

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Choosing for tranquility

Changing industry standards: friend or foe?

Electrical Shore Connections / Cold Ironing

UPS system for emergency lighting and smoke extraction

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Coordination and protection of busbar distribution

DS 600. A contact free flux gate based current measurement sensor 600A rms

Technical Application Papers No.11 Guidelines to the construction of a low-voltage assembly complying with the Standards IEC Part 1 and Part 2

Switchgear and Metal-Enclosed Bus

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

White Paper IK code: Impact protection in line with the IEC standard. By Sven Schnautz

Electrical Safety Tester Verification

Three-phase monitoring relay CM-PFE

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

The complete range of consumer switchboards and switchgear

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Functional system Prisma P

Arc Terminator Active Arc-Resistant Switchgear

NX safety stand-alone

Nothing s BetterThan the Original MODAN Power Distribution Systems

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Video Camera Installation Guide

An assurance of highlevel healthcare thanks to the availability of electric power

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

HIGH VOLTAGE SHORE CONNECTION

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Residual Current Circuit Breaker

Model 1756 Test Lead Kit

Grounding Demystified

SIVACON The Versatile Low-Voltage Switchboard

Low Voltage Products. Switches Automatic Transfer Switches

Installation and safety instructions for AC/DC built-in devices

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Industrial Process Plants. Residential & Commercial Buildings. Roads & Tunnels. Airports & Seaports

CAS 36 Ring Main Unit

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

DEHNshield Application-optimised multipole combined lightning current and surge arrester

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Oil and Coolant Circulating Heating System. Model - OCSM

Secondary Unit Substations

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Type: DILM9 10(24VDC) Article No.:

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

The Intelligent AX1 Switchgear for Medium Voltage

Explosion proof enclosures

Transcription:

End-User Ask for IEC standard and quality All stakeholders are satisfied Standard IEC 61439 clearly defines the type of verifications that must be conducted by both organisations involved in final conformity of the solution: the Original Manufacturer, guaranteeing assembly system design and the Assembly Manufacturer, responsible for the final conformity of the switchboard. Prisma Plus and IEC 61439-1&2 The most reliable switchboard Specifies. Reflects the needs of the user Mount, assemble. Is responsible Guarantee cerfified, tested integrated system combination Specifier Assembly Manufacturer (panelbuilder) > Routine verification Original Manufacturer (Schneider Electric) > Design verification A fully compliant system with guaranteed consistency between electrical devices and equipment. IEC standardization that integrates security, availability and reliability in its recommendations LV functional switchboards that are already fully compliant, for assembly manufacturer s peace of mind Compatible Schneider Electric insurance to be compliant with IEC 61439-1 & 2 standard Make the most of your energy To find out more > Ask for these free materials from your Schneider Electric local representative. > For more information, please visit: www.schneider-electric.com Schneider Electric Industries SAS Head Office 35 rue Joseph Monier CS30323 92506 Rueil-Malmaison Tel.: +33 (0)1 41 29 85 00 http://www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Printed on ecological paper Publishing: Schneider Electric Industries SAS Design - Layout: SEDOC Printing: 2011 Schneider Electric Industries SAS - All rights reserved IEC 61439-1&2 998-4054_GMA 02-2011

A fully compliant system with guaranteed consistency between electrical devices and equipment. IEC standardization that integrates security, availability and reliability in its recommendations LV functional switchboards that are already fully compliant, for assembly manufacturer s peace of mind Make the most of your energy

Ask for IEC standard and quality All stakeholders are satisfied Standard IEC 61439 clearly defines the type of verifications that must be conducted by both organisations involved in final conformity of the solution: the Original Manufacturer, guaranteeing assembly system design and the Assembly Manufacturer, responsible for the final conformity of the switchboard. End-User Specifies. Reflects the needs of the user Mount, assemble. Is responsible Guarantee cerfified, tested integrated system Specifier Assembly Manufacturer (panelbuilder) > Routine verification Original Manufacturer (Schneider Electric) > Design verification Compatible Schneider Electric insurance to be compliant with IEC 61439-1 & 2 standard To find out more > Ask for these free materials from your Schneider Electric local representative. > For more information, please visit: www.schneider-electric.com Schneider Electric Industries SAS Head Office 35 rue Joseph Monier CS30323 92506 Rueil-Malmaison Tel.: +33 (0)1 41 29 85 00 http://www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Printed on ecological paper Publishing: Schneider Electric Industries SAS Design - Layout: SEDOC Printing: 2011 Schneider Electric Industries SAS - All rights reserved 998-4054_GMA 02-2011

Prisma Plus and IEC 61439-1&2 The most reliable switchboard combination IEC 61439-1&2

The main 10 functions of standard IEC 61439 All the verifications proposed by standard IEC 61439 contribute to the achievement of 3 basic goals: safety, continuity of service and compliance with end-user requirements 1 2 3 4 5 6 7 8 9 10 Safety Voltage stress withstand capability Insulation to withstand long-term voltages, transient and temporary overvoltages guaranteed through clearances, creepage distances and solid insulation. Current-carrying capability Protect against burns by limiting excessive temperatures: when any single circuit is continuously loaded to its rated current when any circuit is continuously loaded to its rated current multiplied by its rated diversity factor. Short-circuit withstand capability Withstand short-circuit thanks to short-circuit protection devices, short-circuit coordination, and capability to withstand the stresses resulting from short-circuit currents in all conductors. Protection against electric shock Hazardous live parts are not accessible (basic insulation protection) and accessible conductive parts are not hazardous for life (fault protection, and continuity of protective equipotential bonding). Protection against fire or explosion hazard Protect persons against fire hazards: resistance to internal glowing faulty elements through selection of materials and various design provisions. Continuity of service Maintenance and modification capability Capability to preserve continuity of supply without impairing safety during assembly maintenance or modification. This is achieved through basic and fault protection and optional removable parts. Electro-Magnetic compatibility Properly function and avoid generation of EMC disturbances through incorporation of electronic devices complying with the relevant EMC standard, and their correct installation. Compliance with end-user requirements Capability to operate the electrical installation Properly function, according to: The electrical diagram and the specifications (voltages, co-ordination, etc.) by selecting, installing and wiring the appropriate switching devices. The specified operating facilities (access to Human-Machine Interfaces, etc.) through accessibility and identification. Capability to be installed on site Withstand handling, transport, storage and installation constraints, and be capable to be constructed and connected through selection or design of the enclosure and the external terminals, and by provisions and documentation. Protection of the assembly against environmental conditions Protect the assembly against mechanical and atmospheric conditions through selection of materials and design provisions. Functional panels for small and tertiary buildings Prisma Plus and more than IEC standard! Protection against electrical shocks IPxxB Prisma Plus offers standard components to achieve the right level of electrical protection. Terminal block covers Terminal shields for devices Partitioning for busbar and connections. Voltage stress withstand capability Creepage distances and clearance distances: all functional units are designed from an early engineering stage taking into account minimum clearance distance for any type of assembly of Schneider Electric devices configuration. For instance the Compact NSX breaker can be installed with a rotary handle or motor control or plug-in base with guaranteed clearance distances. For creeping distances all busbar supports are designed to take into account minimum creepage distances required by the IEC standard. Short circuit withstand capability Conditional short circuit test is passed thanks to full coordination using Schneider Electric s devices associated with Prisma Plus distribution components from incoming to outgoers stages. This panel design characteristic allows a much improved service continuity of the switchboard in case of electrical fault. Schneider Electric Product inside* Maintenance and modification capability Beyond IPxxB for panel accessibility Prisma Plus functional system has been designed to offer a clear and logical electrical organisation. It enables safer and more secure accessibility for maintenance and upgrades. Interventions are made quicker with reduced risks of mistakes therefore decreasing down time and improving service continuity. On site installation Linergy busbar Impulse withstand In addition to being lift-tested, Prisma Plus also features handling plinths in order to cover all possibilities for site installations where lifting space is too limited. * Using only Schneider Electric devices guaranties the complience with IEC as well as the reliability of installations. Linergy busbar can safely be accessed for installation upgrade by removing a single Form 2 front barrier only. All conductors are shifted 25 mm enabling qualified electricians to perform intervention from the front of the cubicle only, no need to dismantle the side partitioning for access. Upgrade or maintenance interventions are made faster and more straight forward. Prisma Plus components are designed to match Schneider Electric s devices with impulse voltage withstand reaching up to 12.8 kv specification. Customers are guaranteed to have the right safety margin in case of network transients, increasing safety and installation service continuity over time. IEC 61439-1&2

The main 10 functions of standard IEC 61439 All the verifications proposed by standard IEC 61439 contribute to the achievement of 3 basic goals: safety, continuity of service and compliance with end-user requirements 1 2 3 4 5 6 7 8 9 10 Safety Voltage stress withstand capability Insulation to withstand long-term voltages, transient and temporary overvoltages guaranteed through clearances, creepage distances and solid insulation. Current-carrying capability Protect against burns by limiting excessive temperatures: when any single circuit is continuously loaded to its rated current when any circuit is continuously loaded to its rated current multiplied by its rated diversity factor. Short-circuit withstand capability Withstand short-circuit thanks to short-circuit protection devices, short-circuit coordination, and capability to withstand the stresses resulting from short-circuit currents in all conductors. Protection against electric shock Hazardous live parts are not accessible (basic insulation protection) and accessible conductive parts are not hazardous for life (fault protection, and continuity of protective equipotential bonding). Protection against fire or explosion hazard Protect persons against fire hazards: resistance to internal glowing faulty elements through selection of materials and various design provisions. Continuity of service Maintenance and modification capability Capability to preserve continuity of supply without impairing safety during assembly maintenance or modification. This is achieved through basic and fault protection and optional removable parts. Electro-Magnetic compatibility Properly function and avoid generation of EMC disturbances through incorporation of electronic devices complying with the relevant EMC standard, and their correct installation. Compliance with end-user requirements Capability to operate the electrical installation Properly function, according to: The electrical diagram and the specifications (voltages, co-ordination, etc.) by selecting, installing and wiring the appropriate switching devices. The specified operating facilities (access to Human-Machine Interfaces, etc.) through accessibility and identification. Capability to be installed on site Withstand handling, transport, storage and installation constraints, and be capable to be constructed and connected through selection or design of the enclosure and the external terminals, and by provisions and documentation. Protection of the assembly against environmental conditions Protect the assembly against mechanical and atmospheric conditions through selection of materials and design provisions.

Functional panels for small and tertiary buildings Prisma Plus and mor Short circuit withstand capability Conditional short circuit test is passed thanks to full coordination using Schneider Electric s devices associated with Prisma Plus distribution components from incoming to outgoers stages. This panel design characteristic allows a much improved service continuity of the switchboard in case of electrical fault. Protection against electrical shocks IPxxB Prisma Plus offers standard components to achieve the right level of electrical protection. Terminal block covers Terminal shields for devices Partitioning for busbar and connections. Voltage stress withstand capability Creepage distances and clearance distances: all functional units are designed from an early engineering stage taking into account minimum clearance distance for any type of assembly of Schneider Electric devices configuration. For instance the Compact NSX breaker can be installed with a rotary handle or motor control or plug-in base with guaranteed clearance distances. For creeping distances all busbar supports are designed to take into account minimum creepage distances required by the IEC standard.

e than IEC standard! IEC 61439-1&2 Maintenance and modification capability Beyond IPxxB for panel accessibility Prisma Plus functional system has been designed to offer a clear and logical electrical organisation. It enables safer and more secure accessibility for maintenance and upgrades. Interventions are made quicker with reduced risks of mistakes therefore decreasing down time and improving service continuity. Schneider Electric Product inside* Linergy busbar Linergy busbar can safely be accessed for installation upgrade by removing a single Form 2 front barrier only. All conductors are shifted 25 mm enabling qualified electricians to perform intervention from the front of the cubicle only, no need to dismantle the side partitioning for access. Upgrade or maintenance interventions are made faster and more straight forward. Impulse withstand Prisma Plus components are designed to match Schneider Electric s devices with impulse voltage withstand reaching up to 12.8 kv specification. Customers are guaranteed to have the right safety margin in case of network transients, increasing safety and installation service continuity over time. On site installation In addition to being lift-tested, Prisma Plus also features handling plinths in order to cover all possibilities for site installations where lifting space is too limited. * Using only Schneider Electric devices guaranties the complience with IEC as well as the reliability of installations.