CHROMOPHARE Surgical and Examination Light. Pre-Installation Information

Similar documents
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

LIEBERT VNSA Installation Sheet

Contractors Guide Central Inverter System Installation

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

AUTOMOTIVE LED LIGHT CATALOG

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

INSTALLATION AND SERVICE MANUAL

HMI display Installation Guide

Features. High Brightness LED Light source

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Operating Lights. marlux with centrixbeam LIGHT OF THE NEXT GENERATION

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Parallel Redundant Uninterruptible Power Supply

Lighting. Midmark Animal Health Products

Medical Lighting. XL4 Patient Light

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

120W High Bay II Datasheet

Advantium 2 Plus Alarm

On/Off Relay Switch and 3-Way Switch Kit

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

5W LED Energy Saver PIR Bulkhead

Drayton Digistat +2RF/+3RF

GENERAL WIRING RULES FOR HOUSES

DCF Optimized Rack System

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

SAF-T-LINER MVP-EF PARTS MANUAL. Electrical Section. Page 7-1. Electrical 10/96

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Cooktop Low-Profile Ventilation Hoods

Vehicle Restraint Installation Manual

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

swimming pool accessories

16/32 Channel 1U Rack Mount CCTV Power Supply

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

8146/5 Series Breaker Panelboards

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Operation Manual. Trans-Flo

ELECTRIC CONVECTION BUILT-IN OVEN

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

High / Low Bay Datasheet

INSTALLATION INSTRUCTIONS

Installation, operation and maintenance manual TX 35A

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

No Phone Line II-48 System

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Product and Application Description

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Tips for connecting 24-volt power

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Operating Instructions. Room temperature controller

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

IPS HIGH-BAY / LOW-BAY LIGHTING

Radiant Temperature Sensor TY7321

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

FLEX by 3M Light Module System

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

V94 BULK TAPE DEGAUSSER

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

SECTION LOW VOLTAGE LIGHTING CONTROLS

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Your Basement Remodeling Specialist LLC

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Low / High Bay Datasheet

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Dual Technology Ceiling Mount Sensor

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

2013 Wireless Video Intercom INSTALLATION GUIDE

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Industrial infrared heater IR For premises with large volumes and high ceilings

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Transcription:

CHROMOPHARE Surgical and Examination Light Pre-Installation Information

Table of Contents G Introduction...3 G Technical Data...4 G Hospitals Responsibilities...5 G Overall Room Schematic...6 G Wall Mounted Intensity Control Box (CFWP)...7 G SK Box Containing Transformers...8 G Pre-Wiring Instructions...9 G Superstructure Information...10 G Weight and Momentum...11 G Suggested Superstructure...13 G Mounting Rings...14 G Wall Box Installation...16 G CFWP Box Electrical Diagram...19 G SK Box Schematic...20 G SK Box Enclosure...21-2 -

Introduction The Berchtold CHROMOPHARE C-570, C-571, C-572, C-450, and C-452 represent a modern generation of surgical lights, featuring many technological advances. They are characterized by state of the art electronics, a computer designed polygon reflector, and cardanic suspension of the light head. This includes the following benefits: Freedom from shadows in the operating field. High luminous power which generates the brilliance and high color temperature simulating noontime brightness on a cloudless day. Easier hygiene due to smooth styling of the light body the absence of control knobs on the outer surface, the use of metal and safety glass, and the sealed light head. Larger range of height adjustment; greater mobility of the light. Easy replacement of defective halogen or Xenophot bulbs by OR staff. Cool, single bulb technology, with automatic, instant on back-up bulb. The construction of mechanics and control functions will be described in detail on the following pages. Diagrams and electrical specifications accompany the descriptions. Installation and mounting instruction manuals are included to aid in the mounting and electrical installation. - 3 -

Technical Data Technical Specifications C571 C572 C450 C452 Illuminance at 1 m distance at color temperature 3600 K (1 color temperature 4500 K (1 Field diameter continuously adjustable 120,000 lux 100,000 lux 18-28 cm 7.1 in. -11.0 in. 165,000 lux 135,000 lux 17-24 cm 6.7-9.4 in. 70,000 lux 55,000 lux 16-22 cm 6.5-8.7 in. 105,000 lux 85,000 lux 15-21 cm 5.9-8.3 in. Power Requirements 110/120/130 V AC 250 VA 110/120/130 V AC 140 VA Brightness adjustment Continuous from approx. 50% - 100% Continuous from approx. 50% - 100% (CFWP only) Power consumption main lamp/reserve lamp 150 W / 24 V, Order No. CZ-908-24 110 W / 22.8 V, Order No.CZ-905-2204 Diameter light head 570 mm / 22.4 in. 450 mm / 17.7 in. Polygon reflector 500 mm / 19.7 in. 410 mm / 16.1 in. Maximum working range from 70 cm to 200 cm distance from 60 cm to 200 cm distance Average service life main lamp/reserve lamp approx 1,000 operating hours Swivel radius ceiling light 161/176/198.5 cm / 5.3/5.8/6.5 feet Swivel radius wall light 168 cm / 5.5 feet Height adjustment of the light head 119 cm / 3.9 feet Color rendition index (CRI) 90-94 (2 Absorption of infrared radiation 99% Unchanging light field diameter without refocusing constant up to 500 mm height difference Finish RAL 7035 Light field is adjusted by rotating the sterilizable hand grip (1 + 10% (2 Filter system optional - 4 -

Hospital Responsibilities The hospital, or the hospital s contractor, must complete the following items before Berchtold s installation technicians arrive: 1. CFWP box (wall control unit) installed either by recessing in the wall, or surface mounting it. SEE PAGE 7 2. SK box (contains transformers; used with low ceilings) installed either in the ceiling, or in an area accessible to the technicians. SEE PAGE 8 3. All conduit installed and all necessary wires run. Make all connections in CFWP and SK box. Conduit from SK box needs to have 18 inches of flexible conduit and wire hanging out of ceiling at mounting plate. 4. Superstructure must be complete, and tested to withstand the maximum torque of the light. 5. Light mounting plate must be installed to the superstructure making sure that the plate is flush with the finished ceiling. 6. All painting must be complete with finished flooring installed. * SEE PAGES 7-8 - 5 -

- 6 -

Wall Mounted Intensity Control Box Berchtold s electronic intensity controls consist of two separate entities a wall control box containing electronic circuits to vary the voltage to the transformers which Berchtold Corporation refers to as a CFWP box and a SK box containing one to three step down transformers that power the lights. CFWP CONTROL BOX This control box has space to house electronics necessary for the operation of up to three lights. Since two lights are the norm, this is what will be discussed. This box may be installed on the surface of the wall or it may be recessed. A trim ring is supplied to assist the installer when recessing is desired. The front of the box contains two 4-amp on/off circuit breaker switches, which light up when in the ON position and two knobs for controlling the intensity of the lights. To gain access to wire the electronics, loosen screws in each corner and allow the front door to hinge at the bottom. The only part of the interior that an installer needs to be concerned with are the small wiring blocks located at the top of each circuit board. Even if there are three circuit boards, the factory has wired them together so that only one power connection is necessary to power all of the lights. Close examination of the wiring blocks will show from left to right, two connections marker L1 and L2, two that have the factory installed jumper wires and two with a schematic symbol of a transformer. The installer need only connect the power to L1 and L2 and run two pairs of wires from the terminals with the symbol of a transformer to one of the two ceiling mounted transformers in accordance with the installation instructions. WARNING: ALWAYS RUN A GROUND WIRE. If the transformers are mounted on the flange of the ceiling tube, which also holds the light, the installer need only connect the transformers wires from the CFWP box to the input side of the fused junction block. The rest of the wiring on this particular installation was accomplished at the factory. SEE DRAWINGS FOR CFWP BOX, Pages 17-19 - 7 -

SK Box Containing Transformers If the transformers are NOT installed on the ceiling tube, a SK box containing the transformers must be installed by the installer. This type of installation is always used if the ceiling height does not meet Berchtold Corporation s specifications. Your sales consultant will tell you in advance which installation your hospital requires. If the lights are being installed in a new construction atmosphere, the SK box may be installed above the ceiling near an access hatch, or in an electrical closet if the closet is reasonably near the surgical suite. If the installation is in a suite where only the light is to be replaced, the hospital engineering department must decide what location would be good for them. Either of the locations mentioned above may be used or in a case where space and access is limited, this box may be surface mounted in the surgery suite itself. The transformers in the SK box are factory wired and are attached to a removable plate. This allows the installer to remove the transformers to make installation of the box easier. Inside the box, the installer will find two electrical connection blocks one large block which is fused and one smaller block which is not fused. The wires coming from the CFWP box will hook to the large fused connections. This is the input side of the transformers. The output side of the transformers must be connected to the light heads by connecting two pairs of wires from the smaller junction block (not fused) and running them to the factory mounted wiring block positioned on the flange of the ceiling tube. The factory has pre-wired the light heads. The basic theory of the intensity control consists of controlling the line voltage input to the step down transformers, which in turn varies the voltage to the bulbs, used in the light heads. It is the installer s option as to where he/she mounts the CFWP box or the SK box if used. The only requirement that the manufacturer has is that a minimum of 14 AWG wire be used and if the SK box is mounted an unusual distance from the light, the installer must refer to the wire size tables of the electrical code book to see if 12 AWG wire should be used to carry the necessary 26-28 VAC at 7.2 amps from the SK box to the light junction block. SEE DRAWINGS FOR SK BOX, Pages 20-22 - 8 -

Pre-Wiring Instructions I. PRE-WIRING BERCHTOLD CHROMOPHARE LIGHTS All Chromophare C series lights (regardless of the quantity of light heads) require a single 120-volt supply. This supply should be a 3-wire supply consisting of one HOT, one NEUTRAL, and one GROUND wire. This wire size should be at least 14 AWG, 600 V to meet UL standards. These wires are provided by the hospital, and should be hanging at least 12 inches through the Berchtold mounting ring prior to the Berchtold Service Representative arriving for installation. II. PRE-WIRING BERCHTOLD CFWP BOXES (See Pages 6 & 16-19) A. The CFWP box must be mounted in or on the wall in a manner that will provide accessibility to the light controls by the operating room staff. B. A single 120-volt supply as mentioned above should be provided to the CFWP box. C. A 3-wire supply of the same specifications mentioned above should be run from the CFWP box to the mounting ring for the first light head, and an additional two wires run for each additional light head. These wires again should be hanging through the Berchtold mounting ring prior to installation. III. PRE-WIRING BERCHTOLD CFWP WITH SK BOX (See Pages 6 & 20-22) A. The CFWP box must be mounted in or on the wall in a manner that will provide accessibility to the light controls by the operating room staff. B. A single 120-volt supply as mentioned above should be provided to the CFWP box. C. A 3-wire supply of the same specifications mentioned above should be run from the CFWP box to the SK Box and from the SK Box to the mounting ring for the first light head, and an additional two wires run for each additional light head. These wires again should be hanging through the Berchtold mounting ring prior to installation. - 9 -

Superstructure Information IMPORTANT! **C **CHECK WITH YOUR LOCAL CONSTRUCTION ENGINEERING AGENCY TO MEET LOCAL OR STATE CODES.. HOSPITAL H. H (AND / OR) ) CONTRACTOR C HAS RESPONSIBILITY SIBILITY FOR ) C SUPERSTRUCTURE STRENGTH AND STABILITY.. **. ** - 10 -

Weight and Momentum Model Number Total Weight for Design (lbs) Moment (ft. lbs) C572/224 273 1208 C572/C572/224 341 1475 C572/C452/224 332 1418 C571/224 273 1208 C571/C571/224 341 1475 C571/C450/224 332 1418 C452/224 264 1151 C452/C452/224 322 1363 C450/224 264 1151 C450/C450/224 322 1363 C572 98 439 C572/C572 168 610 C572/C452 159 546 C572/C572/C572 235 877 C572/C572/C452 226 814 C572/C452/C452 217 757 C571 98 439 C571/C571 168 610 C571/C450 159 546 C571/C571/C571 235 877 C571/C571/C450 226 814 C571/C450/C450 217 757-11 -

Weight and Momentum (Continued) Model Number Total Weight for Design (lbs) Moment (ft. lbs) C452 88 261 C452/C452 149 490 C452/C452/C452 208 702 C450 88 261 C450/C450 149 490 C450/C450/C450 208 702-12 -

Suggested Superstructure Pipe Spool Superstructure for Chromophare Installation Check with your local construction engineering agency to meet local or state codes. - 13 -

Mounting Ring CB-510-3304 - 14 -

Mounting Ring CB-509-4504 - 15 -

Wallbox Installation A Wallbox is required for the CFWP Version of the Chromophare C-450, C-452, C-570 and C-571 Surgical Light System. In the CFWP version, controls reduce the supply line voltage by providing intensity settings within the range of 20-24 volts. The 4-amp on/off circuit breaker switches illuminate in the ON position. Berchtold furnishes all components to obtain a complete working unit, ready for installation and connection. Units can be used: A. For surface mounting on finished wall. B. For recessing into a finished wall; one Trim ring supplied. Mounting Procedure: NOTE: A. For surface mounting: Use four anchor pegs to mount the wallbox on the concrete wall, 53 inches above the floor. B. Recessed Mounting: Build frame 53 inches above the floor. 1. THE ELECTRICAL CONNECTION BETWEEN THE WALLBOX AND THE LIGHT FIXTURE IS WIRED BY HOSPITAL OR CONTRACTOR PERSONNEL. 2. THE DISPLAYED DIMENSIONS FOR THE TRIPLE VARIABLE INTENSITY CONTROL ARE IDENTICAL FOR A SINGLE OR DUAL CONTROL BOX. 3. YOU NEED TO PROVIDE 115/120 VOLTS, 50/60 HZ SINGLE-PHASE, 3-WIRE SERVICE. THE WALLBOX MUST BE GROUNDED. 4. YOU NEED TO PROVIDE TWO WIRES AND A GROUNDING WIRE FOR EACH LIGHT HEAD. FOR A DUAL LIGHT, YOU NEED FOUR WIRES AND A GROUND. FOR A TRIPLE LIGHT, YOU NEED SIX WIRES AND A GROUND. - 16 -

Triple Control Wallbox With Intensity Control - 17 -

Triple Control Wallbox (Continued) With Trim Ring - 18 -

Electrical Diagram for Berchtold CHROMOPHARE OR- Light Model C570 & 571 CFWP Single, Double, and Triple Combination Electrical diagram for Berchtold CHROMOPHARE OR Light Model C-450, C-452, C570, and C-571 CFWP single, double, and triple combination. Transformers mounted at the ceiling tube of the OR Light. Light controlled from the wall-box. - 19 -

SK Box Schematic This type 1 enclosure is 34 lbs. with transformers. It is 12 x 12 x 6 in size with removable panel. This enclosure should be securely mounted above ceiling near light fixture. The location of enclosure must have some means of accessibility. - 20 -

SK Box Enclosure Enclosure Size AxBxC 12.00 x12.00x6.00 (305x305x152) Panel Size DxE 10.25x10.25 (260x260) - 21 -

NOTES - 22 -

Safe Innovative Berchtold Berchtold Corporation 1950 Hanahan Road P.O. Box 60399 Charleston, SC 29419-0399 800-243-5135 / 803-569-6100 Fax: 803-569-6133-23 -