Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/2011
|
|
|
- Domenic Stewart Cole
- 9 years ago
- Views:
Transcription
1 Talk-A-Phone Co. Model WEBS-MT/R Emergency Phone Tower Mount Architectural & Engineering Specification rev. 08/29/ General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant free-standing steel emergency phone tower mount, model WEBS-MT/R, no substitutions, with built-in combination LED Blue Light, illuminated faceplate and Wide-Area Emergency Broadcast System (WEBS) capability. The tower shall house an ADA-compliant, communication device manufactured by Talk-A-Phone Co. 2.1 The unit shall be constructed of 0.25" thick steel and shall weigh approximately 435 lbs. 2.2 The unit shall measure 12.75" W x 11" D x 124" H with a 2" radius on each corner. 2.3 High-gloss, multi-layer, corrosion-inhibitive system with resistance to UV-fade and graffiti protection to withstand prolonged exposure to harsh environments. 2.4 An internal base plate shall be fully welded within the tower 2" above the tower base. The base plate shall be fabricated of 0.75" A-36 structural steel. There shall be a 4" diameter center hole for wiring access and four 1" diameter holes for anchor bolt clearance. 2.5 Tower shall have a wiring and anchor bolt access opening measuring 26.0" H x 6.6" W, located 8.0" above the base of the tower. The opening shall have a flush cover plate with a wall thickness of 0.25", held in place by eight countersunk, tamper-resistant spanner screws. 2.6 An opening shall be cut in the face of the column for mounting any flushmounting, 400-Series or 500-Series emergency phone models. The lower edge of the opening shall slope down 30º from rear to front, making the edge difficult to use as a shelf yet convenient as a writing surface. 2.7 Speaker grilles shall be cut out of each side to allow for internally concealed horn speakers. 2.8 A louvered panel shall be installed above or beneath each speaker grille to protect against condensation. 2.9 Tower shall have a hinged door with lock and handle to allow for secure access to a local paging microphone The word "EMERGENCY" shall be emblazoned on all four sides in reflective white letters with wide-angle visibility (custom lettering, sizes and colors available). Each letter shall be 3.25 in height.
2 3 Lighting 4 Electrical 2.11 WEBS Tower shall have a secondary opening with removable perforated aluminum plates for mounting wireless or other devices. 3.1 Atop the tower shall be a Blue Light The Blue Light shall illuminate the area with a luminosity of 209 lumens peak. It would reach 70% of initial lumens after 50,000 hours of operation. It shall be lit at all times The Blue Light shall flash 78 times per minute when the emergency phone is activated and continue flashing until the call has been completed The polycarbonate refractor/housing shall have a prismatic pattern to increase visibility at greater distances Refractor housing shall further be enclosed in a clear polycarbonate security enclosure. 3.2 The tower shall have a concealed ultra-bright LED panel light to illuminate the emergency phone faceplate at all times. LED panel light shall have a lifetime of 100,000 hours. 4.1 Emergency Phone 4.1.1The ETP-400 Series emergency phone communication device shall require no external power. It shall be powered by the phone line, PBX extension, or a wireless communication interface The VOIP-500 Series emergency phone communication device shall operate on Power over Ethernet (PoE, af), a 12VDC power supply, or 24VDC/AC power supply. 4.2 Wide-Area Emergency Broadcast System (WEBS) 4.2.1The WEBS paging amplifier shall operate on standard 120VAC power Analog WEBS wiring should be under 5,700 ft. on communicationsgrade (24AWG or better) twisted and shielded pairs. Only the paging controller end (source side) should be grounded. In order to avoid noise on the line, it is recommended that the WEBS cable not be run in the same conduit as digital or power lines. However, if a location is already running CCTV in the same conduit as our phone line to the emergency phone, and experiencing no problems, the WEBS cable can be run in the same conduit as well. All national, state and local codes must be observed IP-based WEBS shall use Cat 5e or greater wiring.
3 4.3 Lighting 5 Communications 4.3.1The Blue Light shall operate on standard 120VAC power The LED panel light shall operate on universal voltage: 12-24VDC/ VAC 4.4 All lamps and fixtures shall be UL/C.S.A listed. All electrical components shall be hard wired and concealed within the tower. All wiring and electrical fixtures comply with the standards of the National Electrical Code, UL and C.S.A. 5.1 Emergency Phone 5.1.1Tower shall accept any ETP-400 Series or VOIP-500 Series flush mounting emergency phone. 5.2 Wide-Area Emergency Broadcast System (WEBS) 5.2.1WEBS Tower shall accommodate either a connection to an analog paging controller (Model WEBS-ZPS) or a communications module (Model WEBS-CM-2 or VOIP-500 -Series emergency phones) WEBS Tower shall include one 130-Watt RMS amplifier to accommodate an analog connection to model WEBS- ZPS Zone Paging System WEBS Tower shall include one 130-Watt RMS amplifier to accommodate audio line-level connection to Model WEBS-CM-2 Communications Module that allows for IP-based paging in WEBS-enabled mounts (Models WEBS-MT/R, WEBS- PM, WEBS-WM). The WEBS-CM-2 shall be housed inside of the WEBS Tower WEBS paging stations shall have a dedicated headend paging controller. Analog-based WEBS systems shall have a maximum of 99 units. IP-based WEBS systems shall have a virtually unlimited number of units (i.e. maximum number is dependent on network topology) WEBS Tower shall include four 40-Watt, 8 ohms, concealed speakers for use with the Wide-Area Emergency Broadcast System (WEBS). One speaker shall be mounted behind a grille on each side of the tower. There shall be separate volume controls for each individual speaker WEBS Tower shall include a local paging microphone for local tower broadcast and mustering All units can be paged individually, in user defined groups, and as an all-call WEBS Tower audio output shall be 123dB at one meter.
4 6 Mounting 7 Options 6.1 The tower shall include 24-inch J-bolts for mounting into a 24" x 24" concrete foundation, depth to vary according to local regulations and other site-specific considerations. J-bolts shall protrude approximately 5 inches from surface of foundation. 6.2 An optional mounting kit shall be available for mounting into above ground locations such as parking decks, where access to concrete base is available from both above and below. 7.1 Communications 7.1.1Emergency Phone 7.2 Integrated CCTV Emergency Phone communication device shall accept fiber optic line instead of standard copper wire. ETP-400 Series or VOIP-500 Series flush mounting emergency phone and their respective fiber interface shall be required Cellular Interface shall be available when phone line is not available for the 400-Series emergency phone Transmission shall be CDMA 800 or PCS 1900, model ETP-CI/CDMA Transmission shall be 850/1900Mhz GSM, model ETP-CI/GSM Transmission shall be CDMA for Verizon Wireless, model ETP-CI/CDMA-V 7.2.1Model WEBS-MT/R OP2 shall include an integrated fixed camera, supplied by others, mounted above the faceplate Model WEBS-MT/R OP3 shall include an integrated Honeywell Day/ Night camera with varifocal lens mounted above the faceplate. For full specifications of camera, contact Talk-A-Phone Co Model WEBS-MT/R OP4 shall include a metal arm mounted to the rear side of the tower extending over the top of the tower. Blue Light shall mount to the top of the arm and shall not be enclosed in secondary polycarbonate enclosure. Dome camera, supplied by others, shall mount underneath the arm Model WEBS-MT/R OP5 shall include a metal arm mounted to the rear side of the tower extending over the top of the tower. Blue Light shall mount to the top of the arm and shall not be enclosed in secondary
5 polycarbonate enclosure. American Dynamics SpeedDome Ultra V camera shall mount underneath the arm. For full specifications of camera, contact Talk-A-Phone Co. 8 Warranty 9 Manufacturer 8.1 WEBS Tower shall be warrantied against any defects in material and workmanship, under normal use, for a period of five years from date of installation. In the event system is found by manufacturer to be defective within the warranty period, manufacturer shall repair and/or replace any defective parts, provided the equipment is returned to manufacturer. 9.1 The Manufacturer shall be Talk-A-Phone Co. (773) , 7530 N. Natchez Ave, Niles, Illinois , THERE ARE NO EQUIVALENTS.
Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011
Talk-A-Phone Co. Model WEBS-MT/R OP5 Emergency Phone Tower Mount Architectural & Engineering Specification rev. 10/28/2011 1 General Description 2 Construction 1.1 The unit shall be a highly vandal-resistant
TALKAPHONEPROUDLYPARTNERSWI
I l l us t r at edpr i cegui de2013 TALKAPHONEPROUDLYPARTNERSWI TH: Rev.01/ 01/ 2013 Table of Contents Emergency Phone Towers... 3 ETP-MT/R Radius Emergency Phone Tower... 3 ETP-MT Emergency Phone Tower...
VOIP-500 Series Phone Quick Installation Guide
I. Introduction This provides instructions for installation of the VOIP-500 Series Phone. It is recommended to read this instruction set completely before starting any installation. II. Contents Please
INTRUSION DETECTION SYSTEM Section 281600
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
One Room One Cable Architectural Specification
One Room One Cable Architectural Specification ORC-1: One Room One Cable Kit: The ORC-1 One Room One Cable Kit shall consist of one (1) DXW-2 Wall Plate switcher, one (1) DXE-CAT-RX3-A HDBaseT Receiver
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
2 Ohm Nominal Coaxial Speaker OWNER S MANUAL
2 Ohm Nominal Coaxial Speaker OWNER S MANUAL 1 page 1 SPL 65 Coaxial Speaker Congratulations on your purchase of the Soundstream SPL 65 Coaxial Speaker. When used with a high quality 2 ohm rated power
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide
NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series en Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager Table of Contents en 3 Table of Contents 1 Planning 4 1.1 Hardware Requirements 4 1.2 Pre-installation
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 Copyright Notice Copyright 1997 by Asanté Technologies, Inc. All rights reserved. No
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
Canopy Surge. User Manual
Canopy Surge Suppressor User Manual SS00-UM-en Issue 2 May 2003 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Notices Safety Precautions: Before beginning your installation, please read
Emergency Communications Stanchion Applications (Solar/Wireless/Surveillance)
GAI-Tronics A Hubbell Company Emergency Communications Stanchion Applications (Solar/Wireless/Surveillance) Providing Communication Solutions for 65+ Years What is your scenario? - No Power or Telephone
VALCOM ONE-WAY PAGING SYSTEM DESIGN/INFORMATION
Issue 15 VALCOM ONEWAY PAGING SYSTEM DESIGN/INFORMATION GENERAL These instructions provide the basic information required to properly install a OneWay paging system manufactured by Valcom, Inc. Valcom
FLEX by 3M Light Module System
FLEX by M Light Module System Application FLEX by M (the Product ) is a modular lighting system for dry, interior use (the Application ). The Product allows easy creation of long, D lighting paths along
SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE
SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.
CLASSROOM SOUNDFIELD DISTRIBUTION SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification
-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX
-1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.
1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com
1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
pr2969v2-19859.eps FEATURES pr2961v2-19835.eps
./Telephones;Emergency, Assistance/3161 Emergency/Information Phone pr2969v2-19859.eps Used with towers, wall-mounts and surface-mount boxes 232142 ETP-400DV With voice-location identifier Telephones;Emergency/3147
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
PagePac PAGEPAL V-5335700
PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX
LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX The Lantana Luminaire linear light fixture is designed to seamlessly integrate with compatible Lutron control systems. It can be easily
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
V25 Series ArmorDome CCTV Camera User Guide
V25 Series ArmorDome CCTV Camera User Guide Contents Overview................................................... 1 Before You Begin.............................................. 1 Unpacking and Inspection.....................................
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines
PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Lighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
ALARI LED PARKING, ROADWAY & AREA LIGHTING
Project: Fixture Type: Location: H7..A LED UP TO 7W Contact/Phone: PRODUCT DESCRIPTION The ultimate in stylish lighting design, the Alari LED luminaire provides a graceful transition from ground to sky.
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
Fire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
SECTION 16853 ZONED (DC LOOP) FIREALARM SYSTEM
SECTION 16853 ZONED (DC LOOP) FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
A1.5 Classroom Standards
A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional
Bi-Directional Amplifier Systems
Bi-Directional Amplifier Systems Installation and Operation Manual Model Series 850622 EMR CORPORATION 17431 N. 25th Ave. Phoenix, AZ 85023 Emails: [email protected] Phone: (623) 581-2875 Toll-Free: (800)
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com
ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec, Inc. Such proprietary information and materials
E Series. E Series. Category 6 and 5e. Features
E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation
Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.
Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment
IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.
MediaLink IP Intercom System Two-way voice communications over an IP network Integrated microphone, speaker, and call buttons Flexible paging capabilities Classroom intercom system for two-way voice communications,
For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.
For Dealers / Integrators / Architects IS Series Video Intercom Building Communication. Controlling Security. IS Series helps save money Control multiple functions from any location to help reduce overall
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual. www.gefentv.com
Extender for HDMI 1.3 over CAT6 GTV-HDMI1.3-CAT6 User Manual www.gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
IP Intercom System www.extron.com
MediaLink IP Intercom System Two-way voice communications over an IP network Integrated microphone, speaker, and call buttons Flexible paging capabilities Classroom intercom system for two-way voice communications,
GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work
GE Lighting Solutions Albeo LED Luminaire Modular High & Low Bay Lighting (ABHX - Series) imagination at work Product Features The award winning Albeo ABHX-series LED Luminaire utilizes innovative heat-sinking
Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs
Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs Part #: GAU-LB-400 Page: 1 Made in USA Compliant The GAU-LB-400 LED Low Bay Light offers high light output from a compact
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
T-Extender E-Extender
T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8
Using installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
Power over Ethernet (PoE)
Power over Ethernet (PoE) Power over Ethernet (PoE) sends direct current (DC) voltage and computer data over the same Ethernet cable, enabling a device to receive DC power and computer data simultaneously.
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC
Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC Please do not return this item to the store. If you have any questions, please contact
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
Requirements for Electrical Installations
ARTICLE 110 Requirements for Electrical Installations INTRODUCTION TO ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Article 110 sets the stage for how you ll implement the rest of the NEC. This
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev C IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
BACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION
Issue 15 VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION. INTRODUCTION These instructions provide the basic information required to properly install a Valcom Handsfree Talkback Intercom or Paging
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
Long Reach PoE over Coaxial Extender Kit
Long Reach over Coaxial Extender Kit Power over Ethernet Eliminates power cabling with over coaxial Supports Power over Ethernet PSE ( Injector) Power and Ethernet data transmission of 1,000m over coaxial
Protection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply
LED Sign Module LED Super Tiny Strip LED Accessories LED Power Supply April 2016 LED WATERPROOF MODULE LED WATERPROOF MODULE POLAR SERIES LED Type: 5050 SMD Consumption: 0.50 W / module Luminous Flux:
Solar Mounting System
Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,
High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual
High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451. www.lorextechnology.com
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451 www.lorextechnology.com Contents 1x Camera and mounting stand 1x Power adapter 1x Mounting kit 1x Allen key 1x Screw cap 1x 60 ft. (18m)
WIRELESS READER INTERFACE - INDOOR
INSTALLATION INSTRUCTIONS WIRELESS READER INTERFACE - INDOOR (WRI-IN-12VDC or AUWRI-IN-12VDC) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-014-C
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
Ethernet Cat 5e & Cat 6 Patch Panels
Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Ceramic Glass Electric Galley Ranges
Ceramic Glass Electric Galley Ranges OWNER S MANUAL Models # 65335, 65336, 75331, 75332 Read all instructions and warnings before operating. Force 10 Manufacturing Corporation Unit A 19169 21 st Ave Surrey,
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting