LIFT APPLICATION GUIDELINES ACCESSTAIR MODEL VMH-08

Similar documents
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE


P.A.L. S SPECIFICATIONS

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Simplified Steel Stair Design for Commercial and Institutional Buildings

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Roped Hydraulic Residential Elevator Specifications

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

HERNANDO COUNTY FIRE ALARM GUIDELINES

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Automatic Door Selection Guide

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Solar Panel Installations

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

SWAN POINT YACHT & COUNTRY CLUB

BUILDING PERMIT SPECIFICATIONS

Calvert USA, Inc. Attic Stairs

Walking and Working Surface Checklist:

V1504 Vertical Platform Lift OWNER S MANUAL

V1504 Vertical Platform Lift OWNER S MANUAL

Residential Deck Safety, Construction, and Repair

Residential Decks. Planning and Development Services Department

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Troubleshooting Guide for Jacks Down LED Lights

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Number of Sides Required to Have a Handrail

BOROUGH OF OAKLAND COUNTY OF BERGEN STATE OF NEW JERSEY ORDINANCE 13-CODE-685

Fire Pump Plan Review March 2010

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Mobile Home Pre-Inspection Checklist

Fire Alarm System Monitoring - CAN/ULC-S561-03

Fire Alarm System Plans Review Checklist Property location Date of Review

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

EMF/EMR. Holder/Release Devices with Integral Door Closers

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

ACCESS AUDIT OF WESTPORT HOUSE

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

C. Conform to requirements of Americans with Disabilities Act (ADA).

CLEAR-DIVISIONS CENTERFOLD

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

Evolve LED Area Light

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Certification: Building Plans Examiner. Exam ID: B3

Charter Township of Shelby Harry Reese Building Director

Ralls County Emergency Services Request for Proposal & Qualifications Emergency Communications Dispatch Consoles

Planning Information. Passenger and Freight Elevators.

Uncovered Decks & Porches

Architect/Contractor Information Package

CalMod Design-Build Electrification Services

The Pennsylvania State University Physical Security Office. Intrusion Alarm. Performance Specification

301.7D. Mini Hydraulic Excavator

ATS Overhead Table Shelf System INSTRUCTION MANUAL

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

DCF Optimized Rack System

TS93 EMR T/PT/TDE. Surface applied door closer

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

University Design Standard. Fire Alarm Systems

COMMONLY USED RESIDENTIAL BUILDING CODES

OPL BASIC. Dosing System for Professional Laundry machines. Contents

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

One-third of all fatalities in the U.S. construction

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

DC Series Digital Conversion Alarm Operator s Manual

HM-W536 Install Guide

Extracts from BUILDING REGULATIONS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Fire Alarm Systems Certification

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS

SECTION FIRE ALARM AND DETECTION SYSTEM

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

POSITION STATEMENT THE ENGINEER AND THE ENGINEERING TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS. July 28, 2008

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

Cooktop Low-Profile Ventilation Hoods

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

OPERATING INSTRUCTIONS

Transcription:

LIFT APPLICATION GUIDELINES ACCESSTAIR MODEL VMH-08

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES TABLE OF CONTENTS GENERAL INFORMATION...3 PURPOSE...3 PRODUCT OVERVIEW...3 SUITABLE LIFT APPLICATIONS...3 APPLICATION GUIDELINES...4 REGULATORY REQUIREMENTS...4 DESIGN PLANNING...5 ACCESSTAIR MODEL VMH SPECIFICATIONS...7 COMPONENTS SUPPLIED BY...7 RESPONSIBILITY OF OTHERS...8 SCOPE OF WORK BY OTHERS...8 REGULATORY COMPLIANCE BY OTHERS...8 COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 2 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES GENERAL INFORMATION PURPOSE has prepared this document for the purpose of providing building owners and owner representatives such as architects, contractors, and installers with information specific to design planning, special provisions, installation considerations, and regulatory compliance responsibility relevant to the AccesStair Model VMH Vertical Platform Lift, hereinafter referred to as the VMH. The information presented in this document is fairly generic for VMH lift applications and not intended to address every detail or special conditions that may be encountered on a project. PRODUCT OVERVIEW By way of introduction, the VMH lift model is not a conventional vertical platform lift, but rather a convertible stairway / wheelchair lift. The design is unique, wherein two level change systems are combined into one unit. First, the VMH serves as a stairway between a lower landing and an upper landing. Secondly, the VMH provides accessibility to mobility-impaired persons by retracting the stairs and revealing a vertical platform lift. The unit is electronically controlled and simple to operate. SUITABLE LIFT APPLICATIONS VMH units are available to accommodate a vertical rise from 17.50 inches to 50.75 inches in height. Facilities such as schools, museums, performing arts centers, churches, and municipal and public buildings are ideal applications for the convertible stairway / wheelchair lift. The space required for the VMH is typically no greater than the space consumed by traditional stairs. For specific lift envelope dimensions, refer to the Lift Configuration drawing created by for each VMH project. For general concept information, generic 2, 3, 4, 5 & 6-step VMH Lift Configuration drawings are included (see drawings 910-0080 through 910-0084 respectively). COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 3 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES APPLICATION GUIDELINES REGULATORY REQUIREMENTS Vertical Platform Lift design, construction, installation, operation, inspection, testing, maintenance, and repair is specified in Standards developed and published by The American Society of Mechanical Engineers (ASME), entitled ASME A18.1 Safety Standard For Platform Lifts And Stairway Chairlifts. The ASME Standard is intended to serve as the basis for state, municipal, and other jurisdictional authorities in drafting regulations governing Vertical Platform Lifts. With respect to A18.1 effectivity in each jurisdiction, the edition date in effect established by the local jurisdiction may vary; therefore, the local regulations from the authority having jurisdiction (AHJ) must be reviewed prior to each lift installation. For ASME A18.1 references sited in this document, the latest 2014 edition is used. Regarding ASME A18.1-2014, Section 2 categories, the AccesStair corresponds most appropriately with Runway Enclosure Not Provided, reference para. 2.1.3. However, should the local jurisdiction recognize an older ASME edition, a variance may be required to permit the VMH installation. Should that be the case, will, on behalf of the building owner, facilitate expediting the variance application. The basis for a variance request is expressly permitted by A18.1 para. 1.2, which states: The purpose of this Standard is to provide for the safety of life and limb, and to promote the public welfare. The provisions of this Standard are not intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durability, and safety to those prescribed by this Standard provided that there is technical documentation to demonstrate the equivalency of the system, method, or device. The specific requirements of this Standard shall be permitted to be modified by the authority having jurisdiction based upon technical documentation or physical performance verification to allow alternative arrangements that will assure safety equivalent to that which would be provided by conformance to the corresponding requirements of this Standard. For A18.1 regulations applicable to the other trades involved with the lift installation, refer to the section entitled, Regulatory Compliance by Others, on page 8 of this document. COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 4 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES DESIGN PLANNING There are several elements to consider when planning an AccesStair (VMH) lift application. The following recommendations and alternatives are offered to facilitate a diversity of site conditions and customer preferences. must be notified of customer-selected options prior to lift manufacturing. 1. VMH upper landing interface options: a. VMH landing may abut the facility landing or stage. b. VMH landing may be cut into the facility landing or stage. 2. The VMH footprint measures 59 inches wide, whereas the footprint length is contingent upon the vertical rise. Refer to included generic lift configuration drawings (910-0080 through 910-0084) for VMH footprint length. 3. Should the intended location of the VMH lift be in a hallway, the hall width must be no less than 60 inches, and the walls adjacent the lift sidewalls must be plumb within ¼ inch. 4. For applications wherein the VMH upper landing is cut into the facility landing or stage, allow for ½ installation clearance on each of the landing s three sides. 5. To be compliant with ADAAG, space at the lower and upper landings must facilitate a wheelchair turning diameter space of 60 inches. Refer to included generic lift configuration drawings (910-0080 through 910-0084). 6. VMH upper landing floor covering options: a. Standard black vinyl. b. Customer may furnish and install preferred wood, laminate, or vinyl floor covering. Allowable floor covering thickness is 5/8 maximum. 7. Operator control panel mounting options at lower and upper landings: a. Lower landing control panel is located on the front of the VMH unit and may be mounted on either the right or left side. b. Upper landing control panel shall be located remote from the VMH unit. The selected location shall enable the operator to have an unobstructed view of lift operation: i) Wall mounted - Flush. This configuration is standard unless requested otherwise see drawing 910-0059 included at the back of this document. The appropriate enclosure will be provided for mounting in-the-wall. ii) Wall mounted - Surface. This alternative is available upon request. The appropriate enclosure for this option will be provided for mounting on-thewall. iii) Independent pedestal / column. This option is for installations where adjacent walls are not available. COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 5 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES 8. Historically, the lift main power disconnect was mounted remote on a nearby wall. That is no longer necessary with the VMH lift. A lockable and fused main power line disconnect is incorporated on the unit itself at the upper landing. The main power disconnect is readily accessible to qualified persons and within sight of the motor controller (NFPA 70, para. 620-51). Refer to drawing 910-0059 included at the back of this document for source power interface / j-box location. 9. The VMH lift includes an audible alarm, which complies with the emergency signaling device requirements specified in ASME A18.1-2014, para. 2.11.1. However, in some jurisdictions the AHJ may prefer the emergency signaling device to be of the two-way communication type (i.e., telephone or intercom) noted as an alternative in para. 2.11.2. As an add-on option, can provide a two-way speaker-phone installed on the VMH unit. Interface with the building intercom or phone system is the responsibility of the building owner or owner s designated representative. 10. The VMH is available in three textured powder coated finish colors: a. Tan b. Brown c. Black To further facilitate the architectural design process, design files such as 2D CAD drawings and 3D images, contact at 209-838-2400 or e-mail at markramos@hoganmfg.com or donbirdsall@hoganmfg.com. COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 6 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES ACCESSTAIR MODEL VMH SPECIFICATIONS 1. The VMH lift complies with ASME A18.1-2014 and ADAAG. 2. Platform dimensions: 36 inches wide by 55 inches long. 3. Lift capacity (maximum operating load): 750 lbs. 4. Speed: 10 ft./min. maximum. 5. Drive: 2 ACME screw jacks. 6. Vertical travel: 18 inches minimum 50 inches maximum. 7. Finish: all surfaces are powder coated with a textured finish. 8. Power source requirements: 208/230 VAC, 20 amp, 3 wire, single-phase service. 9. Battery back-up: Uninterruptible power supply (UPS) is included. 10. Manual lowering device: included. 11. Shipping weight: approximately 4000 lbs. COMPONENTS SUPPLIED BY The VMH lift package as delivered includes the following: 1. Lift Assembly. 2. Operator Control Panel for upper control station. 3. Wall Mounted Enclosure for upper control station. 4. Labels (operating instructions and warnings). 5. Anchor Bolts. 6. Touch-up paint. 7. Maintenance Manual 8. Training 9. Warranty COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 7 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES RESPONSIBILITY OF OTHERS SCOPE OF WORK BY OTHERS The design, materials, construction, and installation of the following items are the responsibility of others. 1. Lift support structure/foundation. Note: this equipment may require reinforcement of the foundation / floor in order to bear the loads associated with the unit. Refer to drawing 910-0058 included at the back of this document for anchor bolt and load data. Evaluation of these loads and their effect on the structure, as well as any reinforcement required, is by others. 2. Site preparations, including main electrical power connection to lift power input, and associated conduit. Refer to drawing 910-0059 included at the back of this document for source power interface / j-box location. 3. Prior to installation, placement of lift must be defined. 4. Building elements adjacent to the lift, including but not limited to structural framing of landings and walls, and wall finishes. 5. Installation of wall mounted enclosure (supplied by ) for upper control station. Refer to drawing 910-0059 included at the back of this document. Associated conduit for control cables is by others, if required. 6. Installation of applicable operation and warning labels (supplied by ). 7. Illumination of lift area. 8. If required, interface of two-way speaker-phone (supplied by ) with the building intercom or phone system. REGULATORY COMPLIANCE BY OTHERS The ASME A18.1 specifies requirements for the design, construction, installation, operation, inspection, testing, maintenance, and repair for Vertical Platform Lifts. With respect to the VMH installation, while is required to certify that the lift complies with the A18.1 Standard and any variance decisions granted by the AHJ, there are certain requirements associated with elements necessary for the installation of a complete lift system that are not provided by, and therefore require the cooperation of other trades contracted by the building owner. Subsequently, these other trades are responsible for compliance with the A18.1 requirements related to their respective work. These elements are outlined in the Scope of Work by Others noted above. hereby advises the building owner, or owner s designated representative, of the owner s responsibility to communicate the applicable A18.1 requirements to the appropriate trades. To facilitate this effort, has summarized below the A18.1 requirements that other trades involved with the lift installation must comply with - refer to the A18.1 Standard for complete text. COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 8 REV E 4/16

Division of Hogan Mfg., Inc. VMH-08 LIFT APPLICATION GUIDELINES 2.1.5 Pipes in Runway Vicinity No piping is permitted in the runway [lift footprint]. 2.1.8 Structural Support The structure on which the equipment is installed shall be capable of safely supporting the loads imposed. provides the building owner, or owner s representative, with the appropriate load data. 2.1.9 Headroom Clearance Headroom clearance throughout the range of travel shall be not less than 79 inches as measured vertically from the platform floor. Refer to the Lift Configuration drawing for lift operational envelope dimensions. 2.6.6 Illumination 2.6.6.1 At the threshold of the floor, the minimum illumination shall be not less than 5 ftc (50 lx). 2.6.6.2 During operation, the minimum illumination on the floor and controls shall be not less than 5 ftc (50 lx). 2.6.6.3 An auxiliary illumination source to provide general illumination of not less then 0.2 ftc (2.2 lx) on the floor and controls shall be provided. The auxiliary system shall be automatically activated when normal illumination power fails and shall be capable of maintaining the above illumination intensity for a period of not less than 4 hr and shall use no fewer than two lamps of approximately equal wattage. 2.10.1 Operator Control Stations Controls shall be located between 48 inches maximum and 15 inches minimum above the platform floor or facility floor or ground level. Although the maximum height of 48 inches is specified in ASME A18.1, LIFT- U recommends consulting local codes for preferred control locations. 2.11 Emergency Signals If the platform is installed in an area not visible to personnel at all times, an emergency signaling device such as an alarm, or a means of two-way conversation (telephone or intercom) shall be provided. Further, the signaling device(s) shall automatically transfer to standby or emergency power should the building power supply fail. The VMH lift includes an audible alarm and battery back-up system; however, should the AHJ or customer prefer a speaker-phone for two-way communication, can provide such a device; but the interface with the building intercom or phone system is the responsibility of the building owner or owner s designated representative. COPYRIGHT 2016 DOC 599-0008 ALL RIGHTS RESERVED 9 REV E 4/16

R E V I S I O N S LTR ECO APPD DATE DESCRIPTION DFTR DATE CHKR DATE A RELEASED BSA 6/10/2008 B UPDATED J-BOX LOCATION CHART BRB 9/19/2011 C ADDED "SIZE" & "24 MIN" DIMENSIONS BSA 4/18/2012 THRESHOLD UPPER PANEL UPPER PANEL INSTRUCTION LABEL LOWER LANDING VMH LANDING UPPER LANDING / STAGE LOWER PANEL KEY SWITCH & ALARM UPPER LANDING / STAGE VMH LANDING ENCLOSURE AND PANEL (SUPPLIED BY ) ENCLOSURE AND CONDUIT INSTALLED BY CONTRACTOR. OPTIONAL SURFACE MOUNTED ENCLOSURE AVAILABLE 24.00 ELECTRICAL DISCONNECT MIN MOUNTED ON UNIT (FURNISHED BY ) C INSTRUCTION LABEL PANEL LOWER PANEL KEY SWITCH & ALARM ELECTRICAL DISCONNECT MOUNTED ON UNIT (FURNISHED BY ) 14.38 MIN 48.00* MAX TOP OF FINISH FLOOR 11.00 11.00 C J-BOXES & CONDUITS INSTALLED BY CONTRACTOR (BY OTHERS) FOR AC AND DC LINES, ACCESSIBLE TO LIFT CONNECTIONS BELOW LANDING. NOTE: THIS DRAWING IS GENERIC AND PROVIDED FOR INFORMATION ONLY. REFER TO LIFT CONFIGURATION FOR SPECIFIC SITE CONDITIONS. 3/4" CONDUIT (BY OTHERS) 6" MINIMUM RADIUS SWEEP FOR CONDUIT ELBOWS POWER 208/230V 20A FROM DEDICATED CIRCUIT (BY CONTRACTOR) * = CONSULT WITH LOCAL CODES UNLESS OTHERWISE SPECIFIED: - INTERPRET DRAWING PER ANSI Y14.5-1982. - DIMENSIONS ARE IN INCHES. - FINISH ALL PROCESSED SURFACES TO 125 RMS MAX. - DIMENSIONS APPLY TO FINISHED PART, BEFORE PAINTING. - DEBURR ALL SURFACES AND BREAK ALL EDGES.015 x 45. - TOLERANCES (+ OR -): DECIMAL: FRACTION: 1/16.XX =.03.XXX =.010 ANGLE: 1/2 DEGREE.XXXX =.0005 DESC: SPEC: SCALE: SIZE NONE VMH DIM "A" COATING / FINISH NONE FIRST USE REFERENCE: N/A WEIGHT: (LBS.) 6.00 ALLOWABLE ZONE FOR J-BOX LOCATION AT BACK OF LANDING. J-BOXES (BY OTHERS) FOR AC AND DC LINES, ACCESSIBLE TO LIFT CONNECTIONS BELOW LANDING. N/A SIZE DIM "A" 18.00" - 23.99" 6" 24.00" - 29.99" 14" 30.00" - 35.99" 18" 36.00" - 41.99" 24" 42.00" - 47.99" 25" P.O. BOX 398 RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM ESCALON, CA. 95320 OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, 209-838-2400 RECORDING OR OTHERWISE, WITHOUT THE PRIOR A DIVISION OF THIS DOCUMENT IS LOANED FOR THE LIMITED OPERATOR S LAYOUT 910-0059 C 1 OF 1

.50 MIN. INSTALLATION CLEARANCE LOWER LANDING 60" MIN. WHEELCHAIR TURNING SPACE AT LOWER & UPPER LANDINGS 60.00 MIN 59.00 INSTALLATION CLEARANCE BETWEEN BUILDING SURFACES 36.00 (i.e., WALLS) CONTRASTING STRIPE AT STEP NOSE AND STAIR TREADS ARE COVERED WITH BLACK NON-SKID VINYL 2 MOVABLE STEPS (3 RISERS) B B LOCKABLE AND FUSED DISCONNECT SWITCH CONTRASTING STRIPE AT LANDING NOSE R E V I S I O N S LTR ECO APPD DATE DESCRIPTION DFTR DATE CHKR DATE A RELEASED CAL 3/13/2009 B ADDED 60" TURN SPACE, NOTES & SHEET 2 BSA 10/18/2011 UPPER LANDING NOTES: 1. THIS DRAWING IS SUBJECT TO CHANGE PENDING APPLICABLE STATE AND LOCAL CODES, AND CUSTOMER APPROVAL. 2. CUSTOMER MUST PROVIDE APPLICABLE STATE AND LOCAL CODES TO PRIOR TO DESIGN. 3. DRAWING MUST BE SIGNED BY CUSTOMER AND RETURNED TO PRIOR TO PRODUCTION RELEASE. CUSTOMER APPROVAL SIGNIFIES THAT ALL DIMENSIONS ARE CORRECT TO THEIR SPECIFICATIONS. 4. SEE SHEET 2 OF 3 FOR LIFT SPECIFICATIONS. LANDING ABUTS FINISHED FLOOR OF BUILDING LOWER STATION LOCATED ON EITHER SIDE DEPENDING OF BUILDING CONFIGURATION 71.00 27.00 FLOOR COVERING AT LANDING IS BLACK NON-SKID VINYL OR FURNISHED BY CUSTOMER TO MATCH ADJACENT FLOORING. --- PLEASE ADVISE --- 98.00 36.00 STAIR HANDRAIL FINISHED FLOOR HEIGHT STATION (LH SIDE) GRAB RAIL (RH SIDE) 51.00-56.03 A 38.00 35.63 11.00 TREAD 35.63 38.00 53.63 55.06 LENGTH EQUAL RISERS 17.50-22.75 LIFT BASE ANCHORS TO FLOOR. ANCHOR BOLTS FURNISHED BY. 1.75 CUSTOMER FLOOR MUST BE LEVEL (BY OTHERS) PRIOR TO INSTALLATION. ELEVATION VIEW STEPS CONFIGURATION APPROVAL NOTE: CONTRACTOR MUST VERIFY LANDING HEIGHT PRIOR TO RELEASE FOR FABRICATION. MEASUREMENT TO BE TAKEN FROM BASE FLOOR AT THE LOWER LANDING TO THE FINISH FLOOR AT THE UPPER LANDING. ELEVATION VIEW LIFT AT UPPER LANDING P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF STEPS RETRACTED RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 2-STEP 910-0080 1 OF 2 B

BATTERY BACK-UP SYSTEM LOCATED INSIDE OUTER SIDEWALL AUTOMATIC BARRIER GATE (TELESCOPING) STAIR HANDRAIL STATION AUTOMATIC BARRIER ARM LOWER STATION BARRIER ARM IN STOWED POSITION AUTOMATIC RETRACTABLE BARRIER (8" HEIGHT) KEY AND ALARM STEPS CONFIGURATION THRESHOLD STEPS RETRACTED READY FOR PASSENGER INGRESS OR EGRESS TELESCOPING UNDERCARRIAGE GUARD LIFT AT UPPER LANDING READY FOR PASSENGER INGRESS OR EGRESS LOWER DISCONNECT SWITCH LOCATED AT UPPER LANDING. SEE DRAWING 910-0059 FOR J-BOX LOCATION AND PROVISIONS FOR SOURCE POWER. SEE DRAWING 910-0059 FOR MOUNTING INFORMATION KEY SWITCH DETAIL A ALARM SECTION B-B VIEW ROTATED FOR CLARITY UPPER S STATION REFERENCE ONLY P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 2-STEP 910-0080 2 OF 2 B

.50 MIN. INSTALLATION CLEARANCE LOWER LANDING 60" MIN. WHEELCHAIR TURNING SPACE AT LOWER & UPPER LANDINGS CONTRASTING STRIPE AT STEP NOSE 60.00 MIN 59.00 INSTALLATION CLEARANCE BETWEEN BUILDING SURFACES 36.00 (i.e., WALLS) AND STAIR TREADS ARE COVERED WITH BLACK NON-SKID VINYL 3 MOVABLE STEPS (4 RISERS) B B LOCKABLE AND FUSED DISCONNECT SWITCH CONTRASTING STRIPE AT LANDING NOSE R E V I S I O N S LTR ECO APPD DATE DESCRIPTION DFTR DATE CHKR DATE A RELEASED CAL 3/13/2009 B ADDED 60" TURN SPACE, NOTES & SHEET 2 BSA 10/18/2011 UPPER LANDING NOTES: 1. THIS DRAWING IS SUBJECT TO CHANGE PENDING APPLICABLE STATE AND LOCAL CODES, AND CUSTOMER APPROVAL. 2. CUSTOMER MUST PROVIDE APPLICABLE STATE AND LOCAL CODES TO PRIOR TO DESIGN. 3. DRAWING MUST BE SIGNED BY CUSTOMER AND RETURNED TO PRIOR TO PRODUCTION RELEASE. CUSTOMER APPROVAL SIGNIFIES THAT ALL DIMENSIONS ARE CORRECT TO THEIR SPECIFICATIONS. 4. SEE SHEET 2 OF 3 FOR LIFT SPECIFICATIONS. LANDING ABUTS FINISHED FLOOR OF BUILDING LOWER STATION LOCATED ON EITHER SIDE DEPENDING OF BUILDING CONFIGURATION 71.00 27.00 98.00 FLOOR COVERING AT LANDING IS BLACK NON-SKID VINYL OR FURNISHED BY CUSTOMER TO MATCH ADJACENT FLOORING. --- PLEASE ADVISE --- STATION (LH SIDE) 36.00 GRAB RAIL (RH SIDE) STAIR HANDRAIL 56.49-63.03 A FINISHED FLOOR HEIGHT 35.63 38.00 59.63 55.06 LENGTH 38.00 35.63 11.00 TREAD EQUAL RISERS 23.00-29.75 LIFT BASE ANCHORS TO FLOOR. ANCHOR BOLTS FURNISHED BY. 1.75 CUSTOMER FLOOR MUST BE LEVEL (BY CUSTOMER) PRIOR TO INSTALLAITION ELEVATION VIEW STEPS CONFIGURATION APPROVAL NOTE: CONTRACTOR MUST VERIFY LANDING HEIGHT PRIOR TO RELEASE FOR FABRICATION. MEASUREMENT TO BE TAKEN FROM BASE FLOOR AT THE LOWER LANDING TO THE FINISH FLOOR AT THE UPPER LANDING. ELEVATION VIEW LIFT AT UPPER LANDING P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF STEPS RETRACTED RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 3-STEP 910-0081 1 OF 2 B

BATTERY BASK-UP SYSTEM LOCATED INSIDE OUTER SIDEWALL AUTOMATIC BARRIER GATE (TELESCOPING) STAIR HANDRAIL STATION AUTOMATIC BARRIER ARM STEPS CONFIGURATION LOWER STATION SECURITY KEY AND ALARM BARRIER ARM IN STOWED POSITION THRESHOLD STEPS RETRACTED READY FOR PASSENGER INGRESS OR EGRESS AUTOMATIC RETRACTABLE BARRIER (8" HEIGHT) TELESCOPING UNDERCARRIAGE GUARD LIFT AT UPPER LANDING READY FOR PASSENGER INGRESS OR EGRESS LOWER SEE DRAWING 910-0059 FOR MOUNTING INFORMATION DETAIL A SECURITY KEY SWITCH ALARM SECTION B-B VIEW ROTATED FOR CLARITY DISCONNECT SWITCH LOCATED AT UPPER LANDING. SEE DRAWING 910-0059 FOR J-BOX LOCATION AND PROVISIONS FOR SOURCE POWER. UPPER S STATION REFERENCE ONLY P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 3-STEP 910-0081 2 OF 2 B

.50 MIN. INSTALLATION CLEARANCE LOWER LANDING 59.00 60" MIN. WHEELCHAIR TURNING SPACE AT LOWER & UPPER LANDINGS CONTRASTING STRIPE AT STEP NOSE 60.00 MIN INSTALLATION CLEARANCE BETWEEN BUILDING SURFACES (i.e., WALLS) 36.00 AND STAIR TREADS ARE COVERED WITH BLACK NON-SKID VINYL 4 MOVABLE STEPS (5 RISERS) B B LOCKABLE AND FUSED DISCONNECT SWITCH CONTRASTING STRIPE AT LANDING NOSE R E V I S I O N S LTR ECO APPD DATE DESCRIPTION DFTR DATE CHKR DATE A RELEASED CAL 3/13/2009 B ADDED 60" TURNING SPACE, NOTES & SHEET 2 BSA 10/18/2011 UPPER LANDING LANDING ABUTS FINISHED FLOOR OF BUILDING NOTES: 1. THIS DRAWING IS SUBJECT TO CHANGE PENDING APPLICABLE STATE AND LOCAL CODES, AND CUSTOMER APPROVAL. 2. CUSTOMER MUST PROVIDE APPLICABLE STATE AND LOCAL CODES TO PRIOR TO DESIGN. 3. DRAWING MUST BE SIGNED BY CUSTOMER AND RETURNED TO PRIOR TO PRODUCTION RELEASE. CUSTOMER APPROVAL SIGNIFIES THAT ALL DIMENSIONS ARE CORRECT TO THEIR SPECIFICATIONS. 4. SEE SHEET 2 OF 3 FOR LIFT SPECIFICATIONS. FLOOR COVERING AT LANDING IS BLACK NON-SKID VINYL OR FURNISHED BY CUSTOMER TO MATCH ADJACENT FLOORING. --- PLEASE ADVISE --- 36.00 LOWER STATION LOCATED ON EITHER SIDE DEPENDING OF BUILDING CONFIGURATION 71.00 27.00 98.00 STATION (LH SIDE) GRAB RAIL (RH SIDE) STAIR HANDRAIL 63.45-70.03 11.00 TREAD FINISHED FLOOR HEIGHT 35.63 38.00 55.06 LENGTH 71.63 A 38.00 35.63 EQUAL RISERS 30.00-36.75 LIFT BASE ANCHORS TO FLOOR. ANCHOR BOLTS FURNISHED BY. 1.75 CUSTOMER FLOOR MUST BE LEVEL (BY CUSTOMER) PRIOR TO INSTALLAITION ELEVATION VIEW STEPS CONFIGURATION APPROVAL NOTE: CONTRACTOR MUST VERIFY LANDING HEIGHT PRIOR TO RELEASE FOR FABRICATION. MEASUREMENT TO BE TAKEN FROM BASE FLOOR AT THE LOWER LANDING TO THE FINISH FLOOR AT THE UPPER LANDING. ELEVATION VIEW LIFT AT UPPER LANDING P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF STEPS RETRACTED RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 4-STEP 910-0082 1 OF 2 B

AUTOMATIC BARRIER GATE (TELESCOPING) STAIR HANDRAIL BATTERY BASK-UP SYSTEM LOCATED INSIDE OUTER SIDEWALL AUTOMATIC BARRIER ARM STATION LOWER STATION BARRIER ARM IN STOWED POSITION AUTOMATIC RETRACTABLE BARRIER (8" HEIGHT) SECURITY KEY AND ALARM STEPS CONFIGURATION THRESHOLD STEPS RETRACTED READY FOR PASSENGER INGRESS OR EGRESS TELESCOPING UNDERCARRIAGE GUARD LIFT AT UPPER LANDING READY FOR PASSENGER INGRESS OR EGRESS LOWER SEE DRAWING 910-0059 FOR MOUNTING INFORMATION DETAIL A SECURITY KEY SWITCH ALARM SECTION B-B VIEW ROTATED FOR CLARITY DISCONNECT SWITCH LOCATED AT UPPER LANDING. SEE DRAWING 910-0059 FOR J-BOX LOCATION AND PROVISIONS FOR SOURCE POWER. UPPER S STATION REFERENCE ONLY P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 4-STEP 910-0082 2 OF 2 B

.50 MIN. INSTALLATION CLEARANCE LOWER LANDING 59.00 60" MIN. WHEELCHAIR TURNING SPACE AT LOWER & UPPER LANDINGS 60.00 MIN INSTALLATION CLEARANCE BETWEEN BUILDING SURFACES (i.e., WALLS) CONTRASTING STRIPE AT STEP NOSE 36.00 AND STAIR TREADS ARE COVERED WITH BLACK NON-SKID VINYL 5 MOVABLE STEPS (6 RISERS) B B LOCKABLE AND FUSED DISCONNECT SWITCH CONTRASTING STRIPE AT LANDING NOSE R E V I S I O N S LTR ECO APPD DATE DESCRIPTION DFTR DATE CHKR DATE A RELEASED CAL 3/13/2009 B ADDED 60" TURNING SPACE, NOTES & SHEET 2 BSA 10/18/2011 UPPER LANDING LANDING ABUTS FINISHED FLOOR OF BUILDING NOTES: 1. THIS DRAWING IS SUBJECT TO CHANGE PENDING APPLICABLE STATE AND LOCAL CODES, AND CUSTOMER APPROVAL. 2. CUSTOMER MUST PROVIDE APPLICABLE STATE AND LOCAL CODES TO PRIOR TO DESIGN. 3. DRAWING MUST BE SIGNED BY CUSTOMER AND RETURNED TO PRIOR TO PRODUCTION RELEASE. CUSTOMER APPROVAL SIGNIFIES THAT ALL DIMENSIONS ARE CORRECT TO THEIR SPECIFICATIONS. 4. SEE SHEET 2 OF 3 FOR LIFT SPECIFICATIONS. FLOOR COVERING AT LANDING IS BLACK NON-SKID VINYL OR FURNISHED BY CUSTOMER TO MATCH ADJACENT FLOORING. --- PLEASE ADVISE --- 36.00 LOWER STATION LOCATED ON EITHER SIDE DEPENDING OF BUILDING CONFIGURATION 82.00 27.00 109.00 STATION (LH SIDE) GRAB RAIL (RH SIDE) 5.28 70.42-77.03 STAIR HANDRAIL FINISHED FLOOR HEIGHT 35.63 38.00 55.06 LENGTH 11.00 TREAD 77.51 A 38.00 35.63 EQUAL RISERS 37.00-43.75 LIFT BASE ANCHORS TO FLOOR. ANCHOR BOLTS FURNISHED BY. 1.75 CUSTOMER FLOOR MUST BE LEVEL (BY CUSTOMER) PRIOR TO INSTALLAITION ELEVATION VIEW STEPS CONFIGURATION APPROVAL NOTE: CONTRACTOR MUST VERIFY LANDING HEIGHT PRIOR TO RELEASE FOR FABRICATION. MEASUREMENT TO BE TAKEN FROM BASE FLOOR AT THE LOWER LANDING TO THE FINISH FLOOR AT THE UPPER LANDING. ELEVATION VIEW LIFT AT UPPER LANDING P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 5-STEP 910-0083 STEPS RETRACTED 1 OF 2 B

AUTOMATIC BARRIER GATE (TELESCOPING) STAIR HANDRAIL BATTERY BASK-UP SYSTEM LOCATED INSIDE OUTER SIDEWALL AUTOMATIC BARRIER ARM STATION SECURITY KEY AND ALARM STEPS CONFIGURATION LOWER STATION BARRIER ARM IN STOWED POSITION THRESHOLD STEPS RETRACTED READY FOR PASSENGER INGRESS OR EGRESS AUTOMATIC RETRACTABLE BARRIER (8" HEIGHT) TELESCOPING UNDERCARRIAGE GUARD LIFT AT UPPER LANDING READY FOR PASSENGER INGRESS OR EGRESS DETAIL A LOWER SECURITY KEY SWITCH ALARM SECTION B-B VIEW ROTATED FOR CLARITY DISCONNECT SWITCH LOCATED AT UPPER LANDING. SEE DRAWING 910-0059 FOR J-BOX LOCATION AND PROVISIONS FOR SOURCE POWER. UPPER S STATION REFERENCE ONLY SEE DRAWING 910-0059 FOR MOUNTING INFORMATION P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 5-STEP 910-0083 2 OF 2 B

.50 MIN. INSTALLATION CLEARANCE LOWER LANDING 59.00 60" MIN. WHEELCHAIR TURNING SPACE AT LOWER & UPPER LANDINGS 60.00 MIN INSTALLATION CLEARANCE BETWEEN BUILDING SURFACES (i.e., WALLS) 36.00 CONTRASTING STRIPE AT STEP NOSE AND STAIR TREADS ARE COVERED WITH BLACK NON-SKID VINYL 6 MOVABLE STEPS (7 RISERS) B B LOCKABLE AND FUSED DISCONNECT SWITCH CONTRASTING STRIPE AT LANDING NOSE R E V I S I O N S LTR ECO APPD DATE DESCRIPTION DFTR DATE CHKR DATE A RELEASED CAL 3/13/2009 B ADDED 60" TURNING SPACE, NIOTES & SHEET 2 BSA 10/18/2011 UPPER LANDING LANDING ABUTS FINISHED FLOOR OF BUILDING FLOOR COVERING AT LANDING IS BLACK NON-SKID VINYL OR FURNISHED BY CUSTOMER TO MATCH ADJACENT FLOORING. --- PLEASE ADVISE --- NOTES: 1. THIS DRAWING IS SUBJECT TO CHANGE PENDING APPLICABLE STATE AND LOCAL CODES, AND CUSTOMER APPROVAL. 2. CUSTOMER MUST PROVIDE APPLICABLE STATE AND LOCAL CODES TO PRIOR TO DESIGN. 3. DRAWING MUST BE SIGNED BY CUSTOMER AND RETURNED TO PRIOR TO PRODUCTION RELEASE. CUSTOMER APPROVAL SIGNIFIES THAT ALL DIMENSIONS ARE CORRECT TO THEIR SPECIFICATIONS. 4. SEE SHEET 2 OF 3 FOR LIFT SPECIFICATIONS. LOWER STATION LOCATED ON EITHER SIDE DEPENDING OF BUILDING CONFIGURATION 93.00 27.00 120.00 STATION (LH SIDE) GRAB RAIL (RH SIDE) 11.81 77.40-84.03 36.00 STAIR HANDRAIL FINISHED FLOOR HEIGHT 35.63 38.00 55.06 LENGTH 11.00 TREAD 83.51 A 38.00 35.63 EQUAL RISERS 44.00-50.75 LIFT BASE ANCHORS TO FLOOR. ANCHOR BOLTS FURNISHED BY. 1.75 CUSTOMER FLOOR MUST BE LEVEL (BY CUSTOMER) PRIOR TO INSTALLAITION ELEVATION VIEW STEPS CONFIGURATION APPROVAL NOTE: CONTRACTOR MUST VERIFY LANDING HEIGHT PRIOR TO RELEASE FOR FABRICATION. MEASUREMENT TO BE TAKEN FROM BASE FLOOR AT THE LOWER LANDING TO THE FINISH FLOOR AT THE UPPER LANDING. ELEVATION VIEW LIFT AT UPPER LANDING P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF STEPS RETRACTED RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED LIFT CONFIGURATION, 6-STEP 910-0084 1 OF 2 B

AUTOMATIC BARRIER GATE (TELESCOPING) BATTERY BASK-UP SYSTEM LOCATED INSIDE OUTER SIDEWALL AUTOMATIC BARRIER ARM STAIR HANDRAIL STATION LOWER STATION SECURITY KEY AND ALARM STEPS CONFIGURATION BARRIER ARM IN STOWED POSITION THRESHOLD AUTOMATIC RETRACTABLE BARRIER (8" HEIGHT) STEPS RETRACTED READY FOR PASSENGER INGRESS OR EGRESS TELESCOPING UNDERCARRIAGE GUARD LIFT AT UPPER LANDING READY FOR PASSENGER INGRESS OR EGRESS LOWER SECURITY KEY SWITCH ALARM DISCONNECT SWITCH LOCATED AT UPPER LANDING. SEE DRAWING 910-0059 FOR J-BOX LOCATION AND PROVISIONS FOR SOURCE POWER. SEE DRAWING 910-0059 FOR MOUNTING INFORMATION P.O. BOX 398 ESCALON, CA. 95320 209-838-2400 A DIVISION OF RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS ELECTRONICALLY, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE PRIOR THIS DOCUMENT IS LOANED FOR THE LIMITED DETAIL A SECTION B-B VIEW ROTATED FOR CLARITY UPPER S STATION REFERENCE ONLY LIFT CONFIGURATION, 6-STEP 910-0084 2 OF 2 B