Ralls County Emergency Services Request for Proposal & Qualifications Emergency Communications Dispatch Consoles
|
|
|
- Wilfrid Sharp
- 10 years ago
- Views:
Transcription
1 Ralls County Emergency Services Request for Proposal & Qualifications Emergency Communications Dispatch Consoles RFP Response Deadline July 31, 2015
2 INDEX 1. Purpose of RFP Project Description Project Schedule Proposal Requirements 7 5. Proposal Evaluation Console Technical Requirements Additional Terms & Conditions.. 14 Ralls County 911 Emergency Services Dispatch Console RFP 2 P a g e
3 1. Purpose of RFP: The purpose of this Request for Proposal ( RFP ) is to obtain competitive proposals from qualified vendors who can design, furnish, deliver, install and provide service response for Emergency Communication Center console furniture. Parties responding to this RFP shall hereinafter be referred to as Proposer or Proposers. The information submitted by a Proposer in response to this RFP shall be referred to as the Proposal or Proposer s Response. Only those Proposers who are actively engaged in the business of providing Emergency Communication Center Furniture shall be considered as responsible Proposers. For the purpose of this RFP, actively engaged shall mean a recognized leader in the field of Emergency Communication center console design and installation. Documentation, including references showing installations shall be included in Proposer s response. Each Proposer shall be required to respond to the requirements set forth in Section 4, Proposal Requirements. These responses will be evaluated by the evaluation team. The Console RFP Evaluation Team will select the highest ranked Proposer (see Section 5, Proposal Evaluation, for further), who will be required to enter into a Contract with Ralls County Emergency Services. Ralls County 911 Emergency Services Dispatch Console RFP 3 P a g e
4 2. Project Description: Ralls County Emergency Services (9 1 1) is a Public Safety Answering Point that covers an area in excess of 400 square miles. The current population is estimated at 11, operations are currently located in the facility located at Highway 19, New London, Missouri. This Request for Proposal (RFP) is primarily to design, furnish, deliver, install and provide furniture repair/maintenance for the proposed equipment. Public Safety Answering Points (PSAP s)/emergency Communication Centers pose unique c h a l l e n g e s and demands. Unlike an office environment, Emergency Communications Personnel are required to manage multiple LCD/CRT monitors, plus additional ancillary electronics and other resources. Additionally, emergency communications consoles are utilized 24 hours per day/ 7 days per week by many different employees, with many different physical sizes and needs. Because of this, emergency communications consoles can be expected to receive at least five times the use of typical office furniture each year. With this in mind, only console future specifically designed and engineered for Emergency Communication Centers will be accepted. The console design and room layout must positively address employee comfort, efficiency, ergonomics, aesthetics, flexibility, durability, maintainability as well as future expansion. Consoles should meet American National Standards Institute (ANSI) BSR/HFES 100, Human Factors Engineering of Computer Workstations, as well as any applicable Americans with Disabilities Act (ADA) guidelines and requirements. At this time the center is configured with three full dispatch positions. The full dispatch positions will need configured identically as follows: Computer Aided Dispatch (CAD) software on one CPU with one 19 monitor. Motorola radio consoles with one CPU with one 19 monitor. Plant CML with CPU, which will be remotely mounted in the equipment room in the new facility, keypad and one 19 monitors are on the console. This also means two keyboards and two mouse controllers per console. An additional 3 19" monitors will be utilized from the CAD CPU for mapping, state interface system, and call recorder. Ralls County 911 Emergency Services Dispatch Console RFP 4 P a g e
5 The proposer is expected to propose one or more room layouts for the new Communications Center Operations Area to accommodate 3 full dispatch positions initially and layout design to accommodate our 3 existing consoles. Additional design consideration and pricing is being requested for up to 1 more full dispatch position for future expansion. Room dimensions are attached. The Communications Center Operations Area will have an in floor conduit grid system for cabling to the equipment room. Each console will have a dedicated 120VAC outlet for furniture. Ralls County 911 Emergency Services Dispatch Console RFP 5 P a g e
6 3. Schedule: as needed Issue RFP Last Day for Questions Revisions to RFP and answers to questions posted on website RFP Submission Deadline. Original plus four copies of Proposal due from Vendors by 5pm at the Center RFP review and final selection. Ralls County 911 Emergency Services Dispatch Console RFP 6 P a g e
7 4. Proposal Requirements: Any and all questions related to this RFP must be in writing and received by the project manager no later than 5:00 pm local time, September 24, Project Manager: Michael Sheehan Executive Director Ralls County Emergency Services New London, MO questions to clearly identify the e mail Questions for Center Consoles. Phone calls and faxes will not be accepted. Answers to all written questions will be re issued in the form of an addendum and posted to the website under RFP s. ralls911.com It is the responsibility of all interested Proposers to access the web site for this information. One (1) original and four (4) copies of the Proposal are due on??-??-????, by 5:00 pm local time at the Ralls County Emergency Services Center. It is the responsibility of the Proposer to ensure their Proposal is received prior to the listed date/time. Time discrepancies between clocks, watches, cell phones, etc. will not be honored. Delivery Address: Ralls County Emergency Services Attn: Michael Sheehan PO Box 454 New London, MO Ralls County 911 Emergency Services Dispatch Console RFP 7 P a g e
8 Use the following organization for the proposal: Introduction/Cover letter Organizational capabilities, Staff qualifications References Proposed installation timetable Response to Technical Requirements Proposed Room Layouts Detailed cost summaries Any additional material or brochures Introduction/Cover Letter Provide us an overview of your organization and years serving the emergency services furniture marketplace. Organizational capabilities and staff qualifications Describe the firm s experience and capabilities in providing similar layouts and equipment for emergency communications centers. Be specific and identify project, dates and results. Also provide references from these projects for contact. Staff Qualifications Provide resumes describing the educational and work experiences for each of the key staff who will be assigned to the project. Also designating the Proposers primary contact or Project Manager. References Proposals must include a list of organizations, including points of contact (name, address and telephone number), which can be used as references for work performed in similar projects. Selected organizations maybe contacted to determine the quality of work performed and personnel assigned to the project. Proposed Installation Timetable Provide a timetable of events from the contract, through completion of installation. Please discuss how you intend to manage the project through the various stages and how the equipment will be received and staged for installation. Who will install the consoles? Response to Technical Requirements Provide a point by point response to what you intend to supply and how you intend to meet the requirements. If you can provide other options to meeting these requirements, please provide details and optional pricing where appropriate. Ralls County 911 Emergency Services Dispatch Console RFP 8 P a g e
9 Proposed Room Layouts Provide a Drawing for the layout of 3 consoles on the Operations Floor, leaving adequate space for our 1 expansion console. Detailed Cost Summaries Provide detailed pricing for 3 consoles, with separate pricing for 1 more additional consoles on the dispatch floor. Consoles fully delivered and installed. Proposal Offer It is understood and agreed that this proposal and the response of the selected propose, if accepted, will become part of a legal and binding contract between the undersigned Proposer and the Board. The contract shall be in force upon execution of the Notification of Contract Award by the Board. Such notice will be mailed to the Proposer at the address shown on the Proposer s proposal. The Proposer here by declares and agrees with all the terms, conditions and requirements of this request for proposal. Also the undersigned Proposer, having full authority submitting this proposal, hereby declares and agrees to address all aspects of necessary equipment and components as listed here in accordance with all terms, conditions and requirements of the within and proposal. Additional Material Provide brochures or supplemental material you feel will help the evaluation team make an informed decision on your products and any options that you may want to suggest. Ralls County 911 Emergency Services Dispatch Console RFP 9 P a g e
10 5. Proposal Evaluation: The proposals will first be reviewed to determine if proposal requirements indicated above have been met. The accepted proposals will be reviewed by the 911 Board of Directors and scored against stat ed criteria as well as references. The Board will evaluate all proposals in accordance with criteria set forth in this RFP and applicable law. During the evaluation process the Board may see information for a Proposer to clarify the Proposer s proposal. A Proposer must submit written clarifications and such clarifications shall become part of the Proposer s proposal. The Evaluation Criteria to be used is: General Requirements 30% Proposer capabilities, staff and references Proposed Room layout(s) Proposed installation timeline Proposer Qualifications Prior Experience Technical Requirements 40% Criteria and requirements as stated in this RFP Expansion potential Cost 30% Total 100% Final Selection Results The final selection results will be posted on the Ralls County Emergency Services website on after the Proposer selection has been made. R a l l s C o u n t y E m e r g e n c y S e r v i c e s C o n s o l e R F P Page 10
11 6. Console Technical Requirements: A. Structure The structure should be free standing and not rely on walls for support. Since this is an Essential Needs Facility so furniture should be sufficiently anchored to eliminate any potential movement. Describe how you plan to address this. Knee space/leg room shall have minimal obstructions. Show how your system does this. B. Ergonomics The engineering of the console furniture must offer comfort, safety and adjustability for the operator. Console should meet ANSI/BIFMA, BSR/HFES 100, and ADA guidelines and requirements. C. Electrical outlets The consoles will be fed with AC power with an electrical quad box to be mounted to a part of the console. One outlet for the major computer systems that will operate on the furniture. These are Telephone system, CAD system and Radio system. Each console must be provided with at least a six plus electrical strip that will tie to each outlet (three total). All electronics will then tie into these strips for operating each system. D. Cable Management A cable management system must be provided that allows for independent movement among the monitor and keyboard surfaces. The system must minimize the wear and tear on the traveling cables by keeping them separated as well as enclosed. No operator intervention is to be required. The proposer is to provide all cable management within, under and on the console. Describe your system for data docking that allows fast connection of keyboards and additional equipment. E. Monitor and keyboard surfaces The surfaces should be separate and be adjustable separately with smooth, quiet motorized control. The operator must be able to make all monitor and keyboard adjustments from either a standing or sitting position. Surface movement requires the operator to click and hold the controls. At least one inch safety clearance between all moveable and fixed surface is required. A safety system should be in place to prevent accidental lowering of the unit when it is taken off line for service. Proposers are encouraged to propose the ability for users to quickly adjust monitor and keyboard surfaces to personally present heights. F. Monitor Surface The surface must be able to pull forward/push back for operator comfort. The unit must be able to accommodate up to seven (7) 19 inch monitors without obstructing the view. The monitor surface must rise to 50 inches and lower to approximately 23 inches to accommodate operation while sitting or standing. The monitor surface must be able to hold a minimum of 500 static pounds and lift 50 pounds minus the eights of the surface and components. Additionally we encourage the proposer to address considerations of bracket rack mounted monitors, possible dual stacked. R a l l s C o u n t y E m e r g e n c y S e r v i c e s C o n s o l e R F P Page 11
12 G. Keyboard Surface The keyboard surface must rise to 46 inches and lower to approximately 23 inches to accommodate operation while sitting or standing. The monitor surface must be able to hold a minimum of 500 static pounds and lift 50 pounds minus the weight of the surface and components. The keyboard surface must accommodate two standard size keyboards and one keypad for telephone functions. We desire the ability to tilt the keyboard up to 45 degrees, if used how this would this be accomplished. H. Monitor and Keyboard Surfaces These surfaces must be non porous, non glare and of high pressure laminate or solid surface materials of standard color (meaning items readily available or no special order materials). Surfaces should be mark, stain and scuff resistance and easy to maintain and clean. All corners and edges will be rounded and properly finished in similar solid surface materials. I. Task Lighting Each station will have individually dimmable task lighting, mounted on an adjustable arm. For power and heat saving, we would like cool operating, long life LED lights. Please specify the lighting you will supply. Provide its expected life and rated lumen output. J. Equipment Enclosures Each console will have an equipment cabinet that will accommodate all remote mounting equipment, plus equipment needed by the phone provided (Plant Vesta Pallas ACU). The enclosure must allow for easy access and provide interior task lighting (if needed due to location). Enclosures will include quiet blowing ventilation for equipment. The enclosure must be finished in a color matching or complimentary to the Monitor and keyboard surfaces. Exposed edges should be covered with high impact PVC material or equivalent. K. Storage Cabinets Each console will be equipped with additional drawer units for storage of personal items and work items at the various positions. The cabinet would be able to be housed under the keyboard and monitor surfaces while they are in the fullest downward position, or to the side. The drawers should match the color and design of the console. Describe your offering. L. Resource Storage Describe the option to provide an easily accessible cabinet to store resource materials. These could be books of procedures or maps of campus areas. Multiple consoles would share these resources, depending upon room layout. M. Warranty We require a five year warranty on parts and labor for the consoles, with a lifetime warranty on the frame. R a l l s C o u n t y E m e r g e n c y S e r v i c e s C o n s o l e R F P Page 12
13 N. Service All service and warranty work must be initiated within a minimum of 48 hours after notification. Described who would be performing the service work, their location and their connection to your company. O. Training Each proposer is to include training on the new consoles during installation if applicable. This will be a train the trainers class during the installation period at the new Center. R a l l s C o u n t y E m e r g e n c y S e r v i c e s C o n s o l e R F P Page 13
14 7. Additional Terms and Conditions: All drawings, specifications, data, photos and other work products prepared by the Contractor in the performance of its obligations under this Contract shall be exclusive property and shall be remitted to upon the cancellation or expiration of the Contract unless otherwise extended. The Contractor may retain one copy for the Contractor s files. The Contractor shall not use, willingly allow or cause to have such materials used for any purpose other than for meeting performance obligations under this Contract without the prior written consent of Ralls County Emergency Services. Ralls County Emergency Services reserves the right to investigate Proposers background, references, and any other claims made as a result of the Proposers participation of this process. Ralls County Emergency Services is not responsible for costs of proposing if we decide to cancel or re solicit, any costs incurred are at the proposer s own risk. Ralls County Emergency Services reserves the right to accept or reject any or all proposals and to waive any informality in proposals. Exceptions and/or conditions may result in the proposals rejection as non-responsive. Protests and requests for clarification must be in writing. Any changes by the agency will only be reliable if made by formal written addenda and posted to the agency website prior to submission deadline. R a l l s C o u n t y E m e r g e n c y S e r v i c e s C o n s o l e R F P Page 14
15
Consoles. 2014 Product Guide. www.greatamericandesk.com. Great American Desk Company. 2014 Great American Desk Company
Consoles 2014 Product Guide www.greatamericandesk.com consoles- 2014 Great American Desk Company 1600 W Mishawaka Rd Elkhart, IN 46517 574-293- 3591 / 800-387- 7568 2014 Great American Desk Company 1 Consistently
COUNTY OF TANEY, MISSOURI
COUNTY OF TANEY, MISSOURI REQUEST FOR BID For WORKERS COMPENSATION INSURANCE Taney County, Missouri RFB# 201202-168 Workers Compensation Insurance Release Date: February 25, 2012 Submittal Deadline: March
REQUEST FOR PROPOSALS FOR. VoIP RADIO CONSOLES
REQUEST FOR PROPOSALS FOR VoIP RADIO CONSOLES Date: May 11, 2014 Direct Inquiries to: Christopher H. Jett, Technology Director 101 Court Circle, P.O. Box 1000 Warsaw, Virginia 22572 Phone number: (804)
REQUEST FOR PROPOSALS (NO. #RFP-05-003H)
ARKANSAS STATE HIGHWAY AND TRANSPORTATION DEPARTMENT Public Transportation Programs Section REQUEST FOR PROPOSALS (NO. #RFP-05-003H) For The Design and Installation Of A Paratransit Software Scheduling,
MANDATORY PRE-PROPOSAL MEETING WILL BE HELD ON September 22, 2011 @ 1:00 P.M.
REQUEST FOR PROPOSAL (RFP) 13812A FOR DENVER WATER'S Computer Room Cleaning September 15, 2011 Submit Proposal by September 29, 2011 by 11:00 A.M. Mountain Time to: Denver Water Purchasing 1600 West 12th
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
REQUEST FOR PROPOSAL NO. RFP09503 MIDDLE SCHOOL AND HIGH SCHOOL YEARBOOKS. Submittal Deadline: October 29, 2015. Time: 10:00 a.m.
Seattle Public Schools Contracting Services 2445 Third Avenue South Seattle, WA 98134 Telephone: (206) 252-0566 Fax: (206) 743-3018 [email protected] REQUEST FOR PROPOSAL NO. RFP09503
Loss Prevention Reference Note. Adjusting the Computer Workstation. Glare Viewing Distance. Line of Sight Neck Posture Arm Posture Back Posture
Loss Prevention Reference Note Adjusting the Computer Workstation Line of Sight Neck Posture Arm Posture Back Posture Adjustability Glare Viewing Distance Work Surfaces Mouse Position Leg Space Leg Support
125900 FURNITURE and MODULAR OFFICE SYSTEMS
125900 FURNITURE and MODULAR OFFICE SYSTEMS PART 1: GENERAL 1.01 RELATED SECTIONS / POLICIES A. Section 013010 Accessibility for People with Disabilities B. Section 018110 Green Building Guidelines C.
Base Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements
RESOURCES Telehealth Provincial Health Services Authority Telehealth & General Meeting Room Design Requirements Prepared by IMITS, LMC Telehealth and C&W Media Services December, 2013 Revised, August 2014
Organizing and Managing Equipment Rooms
Organizing and Managing Equipment Rooms How you organize and maintain your equipment room can be just as important as maintaining the operating systems on the boxes themselves. Although many companies
REQUEST FOR PROPOSAL Procurement of Landscaping Services
City of Montrose Purchasing Division 433 South First Street PO Box 790 Montrose, CO 81402 REQUEST FOR PROPOSAL Procurement of Landscaping Services Issue Date: Thursday February 27, 2014 Bid Number: 14-012
WELLINGTON E. WEBB MUNICIPAL OFFICE BUILDING DIVISIONS OF FACILITIES MANAGEMENT AND REAL ESTATE. Space Allocation and Furniture Standards
WELLINGTON E. WEBB MUNICIPAL OFFICE BUILDING DIVISIONS OF FACILITIES MANAGEMENT AND REAL ESTATE Space Allocation and Furniture Standards WELLINGTON E. WEBB MUNICIPAL OFFICE BUILDING Space Allocation and
REQUEST FOR PROPOSAL CONSTRUCTION MANAGEMENT SERVICES PIERSON ELEMENTARY REPLACEMENT SCHOOL PROJECT NO. 164519
REQUEST FOR PROPOSAL CONSTRUCTION MANAGEMENT SERVICES FOR PIERSON ELEMENTARY REPLACEMENT SCHOOL PROJECT NO. 164519 School Board of Volusia County Florida Facilities Services 3750 Olson Drive, Daytona Beach
City Of Hammond Purchasing Department REQUEST FOR PROPOSALS RFP 15-07. Servers, Shared Storage & Backup Software
1 City Of Hammond Purchasing Department REQUEST FOR PROPOSALS Servers, Shared Storage & Backup Software Bids Shall Be Received by the Purchasing Department, 310 East Charles Street P.O. Box 2788 Hammond,
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS 1.0 GENERAL INFORMATION Structural Interior Design includes all building related elements and components generally part of the building itself,
ADVERTISEMENT FOR BIDS DUCKETT CREEK SANITARY DISTRICT TP1 CLARIFIERS #1 AND #2 REHABILITATION
ADVERTISEMENT FOR BIDS DUCKETT CREEK SANITARY DISTRICT TP1 CLARIFIERS #1 AND #2 REHABILITATION Notice is hereby given that the Duckett Creek Sanitary District will receive sealed proposals at the Duckett
Trading Desks. 2014 Product Guide. www.greatamericandesk.com. Great American Desk Company. 2014 Great American Desk Company
Trading Desks 2014 Product Guide www.greatamericandesk.com tradingdesks- 2014 Great American Desk Company 1600 W Mishawaka Rd Elkhart, IN 46517 574-293- 3591 / 800-387- 7568 2014 Great American Desk Company
Request for Quotation (RFQ) for Adjustable Sit to Stand Desk Reference No.: UNWHQRFQ31. [Insert Title of Goods]
Request for Quotation (RFQ) for Adjustable Sit to Stand Desk Reference No.: UNWHQRFQ31 [Insert Title of Goods] 01 September, 2015 Dear Sir/Madam, Subject: Request for Quotation (RFQ) for the provision
REQUEST FOR PROPOSAL RFP #12-004. For the Provision of After Hours Answering Services. Proposal Due Date/Time: October 19, 2012 @ 4:00 p.m.
REQUEST FOR PROPOSAL RFP #12-004 For the Provision of After Hours Answering Services Proposal Due Date/Time: October 19, 2012 @ 4:00 p.m. Children s Aid Society of London and Middlesex 1680 Oxford Street
HACC Central Pennsylvania s Community College Harrisburg, PA. Request for Proposal RFP14-04. For Website Content Development HACC
HACC Central Pennsylvania s Community College Harrisburg, PA Request for Proposal RFP14-04 For Website Content Development HACC Issued: Feb. 24, 2014 Deadline for Questions: Response to Questions: PROPOSAL
HEATING VENTING AND AIR CONDITIONING (HVAC) SUBCONTRACTING SERVICES FOR THE MACON COUNTY HOUSING DEPARTMENT
REQUEST FOR PROPOSALS RFP#03 4004p HEATING VENTING AND AIR CONDITIONING (HVAC) SUBCONTRACTING SERVICES FOR THE MACON COUNTY HOUSING DEPARTMENT ISSUE DATE: MAY 31, 2013 ISSUING DEPARTMENT: MACON COUNTY
Request for Proposals
Request for Proposals Title: RFP #: 2010-HR-001 Issue Date: January 4, 2010 Due Date/Time: January 28, 2010 2 p.m. Issuing Agency: Harnett County Human Resources Department 102 E. Front Street P.O. Box
BID SPECIFICATION PACKAGE
REQUEST FOR PROPOSALS: E-RATE TELEPHONE SYSTEM & COMPLETE INTERNAL CONNECTIONS BID SPECIFICATION PACKAGE FOR: HOUSTON GATEWAY ACADEMY, INC. REQUEST FOR PROPOSAL Telephone System for Houston Gateway Academy,
REQUEST FOR PROPOSALS BOND COUNSEL SERVICES FOR AFFORDABLE HOUSING RFP # 16-018. Santa Ana Housing Authority
REQUEST FOR PROPOSALS BOND COUNSEL SERVICES FOR AFFORDABLE HOUSING RFP # 16-018 20 Civic Center Plaza Santa Ana, CA 92701 Judson Brown Housing Division Manager (714) 667-2241 Office [email protected]
Instructions to Bidders Publication of Yearbook Bid
Instructions to Bidders Publication of Yearbook Bid Sealed bids will be accepted in the Administration Building, Scooba Campus, 1512 Kemper Street, P.O. Box 158, Scooba, MS 39358 until 2:00 p.m., Tuesday,
INVITATION TO BID. Web and Application Development Services. Monday, February 23, 2015 at 10:00 AM
200 GRAND RIVER, SUITE 203 Pg 1 of 11 BID: RFP-IT-0215-292 INVITATION TO BID ITEM: PreBid Conference: DEADLINE: BID OPENING: Web and Application Development Services Monday, February 9, 2015 at 11:00 AM
City of Fulton, Missouri REQUEST FOR PROPOSAL
City of Fulton, Missouri REQUEST FOR PROPOSAL RETURN ALL RFPS TO: CITY OF FULTON C/O Carolyn Laswell City Clerk P.O. BOX 130 18 EAST 4 TH STREET FULTON, MO 65251-0130 RFP. NO. P-201231 DATE 05/22/12 REQ.
Request for Proposal East Tower Nursing Unit and Infrastructure Upgrade Grossmont Hospital
Request for Proposal East Tower Nursing Unit and Infrastructure Upgrade Grossmont Hospital June 21, 2007 The Grossmont Healthcare District (GHD) will accept proposals for Architectural and Engineering
COLLEGE OF WESTERN IDAHO. Request for Proposal WEBSITE REDESIGN SERVICES. Due: November 8, 2010 At 5:00 p.m. Deliver to:
COLLEGE OF WESTERN IDAHO Request for Proposal WEBSITE REDESIGN SERVICES Due: November 8, 2010 At 5:00 p.m. Deliver to: College of Western Idaho Attn: Jennifer Couch RFP-Website Redesign Services 6056 Birch
PINE-STRAWBERRY WATER IMPROVEMENT DISTRICT P.O. BOX 134 PINE, ARIZONA 85544-0134 REQUEST FOR PROPOSALS
PINE-STRAWBERRY WATER IMPROVEMENT DISTRICT P.O. BOX 134 PINE, ARIZONA 85544-0134 REQUEST FOR PROPOSALS Point to Point Leak Detection Survey RFP # 2014-02 PROPOSAL OPENING DATE July 26, 2013 3:00 PM REQUEST
REQUEST FOR PROPOSAL FOR BUILDING MANAGEMENT SYSTEMS SERVICES. San Carlos School District
REQUEST FOR PROPOSAL FOR BUILDING MANAGEMENT SYSTEMS SERVICES San Carlos School District June 12, 2015 The San Carlos School District, hereinafter referred to as the Owner invites proposals for the installation
Request for Proposal (RFP) Occupational and Physical Therapy. Deadline for Submission: August 25, 2014
Department of Exceptional Learning Request for Proposal (RFP) Occupational and Physical Therapy Deadline for Submission: August 25, 2014 Notices to Companies/Firms Copies of RFP can be printed from our
Request for Proposal Architectural/Engineering Services. Adapt/SouthRiver CHC. P a g e 1
P a g e 1 Request for Proposal Architectural/Engineering Services Adapt/SouthRiver CHC RFP for Architectural/Engineering Services P a g e 2 Introduction (SRCHC), a Federally Qualified Health Center, is
Purchasing a Business in Utah - RFP Approval Bid Process
REQUEST FOR PROPOSAL To Provide Services for RELEASE DATE: November 11, 2010 DUE DATE: December 10, 2010 2 p.m. Mark Hoss Purchasing Coordinator I. GENERAL TABLE OF CONTENTS PAGE A. Intent of Request for
INTERIOR CONCEPTS Contact Center
INTERIOR CONCEPTS Contact Center For once, less really is more. Our innovative panel system takes up less room and allows you to move fluidly within your space. By working around the existing architecture,
MANCHESTER WATER WORKS REQUEST FOR PROPOSALS FOR WATER ASSET MANAGEMENT SOFTWARE AND SERVICES RFP #FY15-804-64
FY15-804-64 MANCHESTER WATER WORKS REQUEST FOR PROPOSALS FOR WATER ASSET MANAGEMENT SOFTWARE AND SERVICES RFP #FY15-804-64 FY15-804-64 Invitation to Propose 2 Part 1 - Instructions to Proposers 1.1. Receipt
Video Conferencing Solutions
Video Conferencing Solutions Innovative Products To Make Your Video Conferencing More Effective Just like the internet, video conferencing is evolving rapidly. New efficiencies, benefits, and audiences
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS
CITY OF BEAUFORT SOLICITING SEALED PROPOSALS FOR MOBILE REFUSE CARTS The City of Beaufort is requesting sealed, competitive, proposals for interested Vendors to provide the City of Beaufort fifty-five
MailroomFurniture C A T A L O G U E
MailroomFurniture C A T A L O G U E Mailroom and Additional Components CONTENTS 3 Introduction 5 Modular Tables 7 Standard Tables 9 Height Adjustable Mailroom Tables 11 Risers & Sorters 13 Mailroom Accessories
Request for Qualifications 2015-162
Kitsap County Human Services Department Request for Qualifications 2015-162 Architectural and Project Management Services - Kitsap County Work Release Facility Remodel Response Deadline: November 17, 2015
GORDON COUNTY BOARD OF COMMISSIONERS REQUEST FOR QUALIFICATIONS FOR AN ARCHITECT FAMILIAR WITH COMMUNITY DEVELOPMENT BLOCK GRANT APPLICATIONS
GORDON COUNTY BOARD OF COMMISSIONERS REQUEST FOR QUALIFICATIONS FOR AN ARCHITECT FAMILIAR WITH COMMUNITY DEVELOPMENT BLOCK GRANT APPLICATIONS DATE RFQ RELEASED July 13, 2013 1 PURPOSE OF THIS REQUEST FOR
REQUEST FOR QUOTES (RFQ)
REQUEST FOR QUOTES (RFQ) Lincoln County Public Works is requesting quotes (RFQ) through its Small Works Roster Process. Quotes are being requested for a project to replace the roof on the Crew Headquarters/Truck
KANSAS CITY AREA TRANSPORTATION AUTHORITY ADDENDUM #1 TO RFP #13-7028-30
KANSAS CITY AREA TRANSPORTATION AUTHORITY ADDENDUM #1 TO RFP #13-7028-30 FOR A CONSULTANT TO PROVIDE TRIP SCHEDULING AND QUALITY ASSURANCES FOR KCATA S PARATRANSIT OPERATIONS NOVEMBER 5, 2013 The information
COUNTY OF YUBA REQUEST FOR PROPOSAL SOUTH ANNEX BUILDING ASBESTOS ABATEMENT. Due Date: November 13, 2009 Time: 2:00 PM, PST.
COUNTY OF YUBA REQUEST FOR PROPOSAL SOUTH ANNEX BUILDING ASBESTOS ABATEMENT Due Date: November 13, 2009 Time: 2:00 PM, PST. October 19, 2009 To: All Interested Vendors Re: Request for Proposals, County
APPALCART REQUEST FOR PROPOSAL
APPALCART REQUEST FOR PROPOSAL COMPUTER, NETWORK, AND SERVER CONSULTING INTRODUCTION AppalCART (the Authority) is issuing this Request for Proposal (RFP) to solicit contractor proposals to provide oversight
Designed for comfort and built to last.
Designed for comfort and built to last. Inter IKEA Systems B.V. 2015 Whether we work in an office or at home, many of us spend the majority of the day at a desk. A comfortable workspace is therefore essential
SEALED BID SOLICITATION QUOTATION BLANKET ORDER
Page 1 SEALED BID PROPOSAL FORM L. BROOKS PATTERSON - OAKLAND COUNTY EXECUTIVE OAKLAND COUNTY PURCHASING DIVISION SOLICITATION QUOTATION BLANKET ORDER Contact Information: Buyer: Joan Daniels Oakland County
Request for Proposal - Business Telephone System
Request for Proposal - Business Telephone System Return Bid No Later Than: August 1 at 10:00 am Return Bid To: Town of Weaverville PO Box 338 Weaverville, NC 28787 Attn: Michael Boaz Description: Purchase,
REQUEST FOR PROPOSAL FOR SECURITY CAMERA SYSTEM AT CONWAY LAW ENFORCEMENT CENTER CONWAY, SC 29526
REQUEST FOR PROPOSAL FOR SECURITY CAMERA SYSTEM AT CONWAY LAW ENFORCEMENT CENTER CONWAY, SC 29526 Stephanie Carroll, Technology Coordinator [email protected] 843 248 1760 LEC Security Camera System
Invitation to Bid and Instructions to Bidders (This is Phase I of the project please note on any Bid that it Applies to Phase I only) May 1, 2015
Invitation to Bid and Instructions to Bidders (This is Phase I of the project please note on any Bid that it Applies to Phase I only) May 1, 2015 For PROJECT : Renovation and Repair of Atlanta Jewish Academy
COWLITZ-WAHKIAKUM COUNCIL OF GOVERNMENTS REQUEST FOR PROPOSALS
COWLITZ-WAHKIAKUM COUNCIL OF GOVERNMENTS REQUEST FOR PROPOSALS Disaster Resiliency Program Cowlitz-Lewis Economic Development District (CLEDD) INVITATION Cowlitz-Wahkiakum Council of Governments, hereby
SECTION 273226 (16630) RESCUE ASSISTANCE TELEPHONE SYSTEM (Rev Jun 2011)
SECTION 273226 (16630) RESCUE ASSISTANCE TELEPHONE SYSTEM (Rev Jun 2011) PART 1 - GENERAL 1.00 DESCRIPTION A. Furnish and install hands free communication devices at all areas of Rescue Assistance as indicated
Part 2 Definitions for this Policy 2.1. ADA / TAS the Americans with Disabilities Act / Texas Accessibility Standards.
Office of Space Management Page 1 of 6 Part 1 Purpose 1.1. This policy establishes space allocation and space use guidelines for UTSA entities occupying space in UTSA-owned and UTSA-leased facilities.
FIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
Laboratory Construction Guidelines Vicon MX Systems
Laboratory Construction Guidelines Vicon MX Systems These Vicon MX Laboratory Construction Guidelines illustrate how to prepare a life sciences laboratory for installation of your new Vicon MX motion measurement
N O T I C E REQUEST FOR STATEMENT OF QUALIFICATIONS RFQ#1610-007 POLICE DEPARTMENT PARKING GARAGE
N O T I C E REQUEST FOR STATEMENT OF QUALIFICATIONS RFQ#1610-007 POLICE DEPARTMENT PARKING GARAGE The City of Frisco is seeking qualification statements from experienced engineering, architecture, and
1. Proposals must be received by mail or email by Jan 11th 2015 at 12PM.
TIME AND ATTENDANCE SYSTEM REQUEST FOR PROPOSAL Joplin Schools Technology Department P.O. Box 128 Joplin MO 64802-0128 Phone (417) 625-5200 General Information 1. Joplin Schools ( District ) seeks proposals
This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents and Prior Addenda if any, as identified above.
To: All Vendors Bidding on The College of New Jersey Security Cameras Phase III From: Roselle Horodeski Finance and Business Services Date: April 10, 2015 ADDENDUM NO. 1 ISSUE DATE: April 10, 2015 REFERENCE:
Washington County School District Request for Proposal School Bus Fleet Tracking System RFP #TD 1011
Request for Proposal I. GENERAL A. Intent of Request for Proposal (RFP) The purpose of this Request for Proposal is to solicit sealed, competitive proposals from vendors qualified and experienced to provide
Technical Bulletin: Understanding the ADA and Implications for Office Design
Technical Bulletin: Understanding the ADA and Implications for Office Design What is the ADA? The Americans with Disabilities Act (ADA) is a federal law enacted in 1990. It prohibits discrimination on
REQUEST FOR PROPOSAL (RFP)
REQUEST FOR PROPOSAL (RFP) Subject: Due Date/Time: Submit To: Financial Management & Utility Billing Software March 28, 201412:00 pm Eastern Standard Time Chris Wilson Village of Beverly Hills 18500 W
Request for Proposal Posted: March 4, 2015 After Hours Answering Service RFP No. 06.15
S PRINGFIELD UTILITY BOARD Electric Service Center Request for Proposal Posted: March 4, 2015 After Hours Answering Service RFP No. 06.15 Proposals Due: March 12, 2015 @ 2:00 pm Technical Questions RFP
BOROUGH OF HADDONFIELD CAMDEN COUNTY NEW JERSEY ARCHITECTURAL SERVICES RELATED TO THE HADDONFIELD LIBRARY REQUEST FOR PROPOSAL
BOROUGH OF HADDONFIELD CAMDEN COUNTY NEW JERSEY ARCHITECTURAL SERVICES RELATED TO THE HADDONFIELD PUBLIC LIBRARY REQUEST FOR PROPOSAL Project Name: ARCHITECTURAL SERVICES RELATED TO THE HADDONFIELD PUBLIC
PROPOSALS REQUESTED THE TOWN OF OLD ORCHARD BEACH POLICE DEPARTMENT FOR IP-BASED VOICE COMMUNICATION SYSTEM
PROPOSALS REQUESTED BY THE TOWN OF OLD ORCHARD BEACH POLICE DEPARTMENT FOR IP-BASED VOICE COMMUNICATION SYSTEM The Town of Old Orchard Beach will receive sealed bids for an IP based phone system. The project
NOLENSVILLE POLICE DEPARTMENT REQUEST FOR PROPOSAL AND BID RECORDS MANAGEMENT SYSTEM SOFTWARE
NOLENSVILLE POLICE DEPARTMENT REQUEST FOR PROPOSAL AND BID RECORDS MANAGEMENT SYSTEM SOFTWARE THIS PROJECT IS FUNDED UNDER AN AGREEMENT WITH THE STATE OF TENNESSEE Proposal Due Date/Time October 31, 2014
HOUSTON COUNTY BOARD OF COMMISSIONERS PURCHASING DEPARTMENT
August 5, 2015 Dear Vendor: The Houston County Board of Commissioners is soliciting sealed bids for the provision of one (1) new 2015 or 2016 year model Ford Explorer SUV for use by the Houston County
Request for Proposals. For a. Fire Station Alerting System
Request for Proposals For a Fire Station Alerting System SouthCom Combined Dispatch Center 21113 Dettmering Dr., Matteson, IL. 60443 Ph: (708) 283-6631 Fax: (708) 283-6641 REQUEST FOR PROPOSALS 911 EMERGENCY
REQUEST FOR INFORMATION FOR #2015-12 POINT OF SALE SYSTEM. November 18, 2015
REQUEST FOR INFORMATION FOR #2015-12 POINT OF SALE SYSTEM November 18, 2015 Questions Due: December 9, 2015 at 12:00 p.m. SUBMISSIONS DUE: December 18, 2015 at 11:00 a.m. 2425 NE 65th Avenue ~ PO Box 2529
MIDDLESEX COUNTY JOINT HEALTH INSURANCE FUND
MEDICAL INSURANCE CARRIER CLAIM AUDIT All proposals must be submitted in accordance with the following Standardized Submission Requirements and Selection Criteria established by the Middlesex County Joint
Request for Proposal. Branding for the Reference and User Services Association (RUSA)
Reference and User Services Association A division of the American Library Association 50 E. Huron St. Chicago, IL 60611 (312) 280-4398 (800) 545-2433 x4398 Fax (312) 280-5273 http://www.ala.org/rusa Request
LOCUM TENENS SERVICES
Issue Date: March 19, 2014 COUNTY OF MERCED REQUEST FOR QUALIFICATIONS NUMBER 7042 LOCUM TENENS SERVICES Mark A. Cowart Administrative Services, Chief Information Officer 2222 M Street Merced, CA 95340
REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations
Chapter Five: REQUIREMENT 5 Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations 5...covered multifamily dwellings with a building entrance on an accessible
AUTOMATED AIRCRAFT IDENTIFICATION AND BILLING SERVICES
COUNTY OF SONOMA AUTOMATED AIRCRAFT IDENTIFICATION AND BILLING SERVICES FOR THE CHARLES M. SCHULZ SONOMA COUNTY AIRPORT Request for Proposals (RFP) The County of Sonoma, Charles M. Schulz Sonoma County
APPENDIX K. Design/Layout Considerations for Ceiling/Overhead Lift Tracks. Ceiling Lift Motor Charging Options
ArjoHuntleigh APPENDIX K Design/Layout Considerations for Ceiling/Overhead Lift Tracks At present, not all clinical units or areas require 100 percent ceiling lift coverage (Table I-1), but with expansion
Mechanical Contractor Pre-Qualification Packet. SPSC N180 Computer Data Room Phase II. Project No. CP 159313. Notice No. Notice 13-11.
Mechanical Contractor Pre-Qualification Packet SPSC N180 Computer Data Room Phase II Project No. CP 159313 Notice No. Notice 13-11 Issued by Department of Facilities Management Delivery address: Research
ATLANTA PUBLIC SCHOOLS
Procurement Services 130 Trinity Avenue, S.W. 5 th Floor Atlanta, Georgia 30303 Request for Qualifications For October 31, 2007 Solicitation Number: 112607-01 Due Date: November 26, 2007 ADVERTISEMENT
City of Sacramento Community Wireless Broadband Network
Request for Information (RFI) (I15071011001) City of Sacramento Community Wireless Broadband Network RFI Submittals Due: August 22, 2014 by 3:00 p.m. (PST) (Submit electronically, in PDF format) via the
REQUEST FOR PROPOSAL: STRUCTURED CABLING, LAN SWITCHES, LONG DISTANCE SERVICE, ELECTRONIC FAXING, AND HOSTED VOIP SPECIFICATIONS
SECOND ADDENDUM TO RFP DOCUMENTS REQUEST FOR PROPOSAL: STRUCTURED CABLING, LAN SWITCHES, LONG DISTANCE SERVICE, ELECTRONIC FAXING, AND HOSTED VOIP SPECIFICATIONS 11/9/2015 To All Potential Bidders: This
5. Preparation of the State and Federal Single Audit Reports.
THE CITY OF GROTON REQUEST FOR PROPOSAL FOR AUDITING SERVICES RFP 15-01 (Revised 5/28/15) 1. Introduction The City of Groton, Connecticut (the City) is soliciting proposals for purpose of obtaining the
Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery
Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service