Patient-specific kerma-area product as an exposure estimator in computed tomography: the concept and typical values.

Similar documents
Assessing Radiation Dose: How to Do It Right

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Diagnostic Exposure Tracking in the Medical Record

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as implying such endorsement.

Purchasing a cardiac CT scanner: What the radiologist needs to know

Practical exercise: Effective dose estimate in CT

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

GE Healthcare. DoseWatch. Gathering Radiation Dose Data

Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University

DETERMINATION OF THE EFFECTIVE VOLUME OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

ACCELERATORS AND MEDICAL PHYSICS 2

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

Fundamentals of Cone-Beam CT Imaging

Production of X-rays and Interactions of X-rays with Matter

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Proton tracking for medical imaging and dosimetry

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

90 degrees Bremsstrahlung Source Term Produced in Thick Targets by 50 MeV to 10 GeV Electrons

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Atomic and Nuclear Physics Laboratory (Physics 4780)

Laue lens for Nuclear Medicine

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Qualitätsmanagement-Handbuch

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Conversion coefficients from air kerma to personal dose equivalent H p (3) for eye-lens dosimetry

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS

where h = J s

AAPM REPORT NO. 39 SPECIFICATION AND ACCEPTANCE TESTING OF COMPUTED TOMOGRAPHY SCANNERS

Theremino System Theremino Spectrometer Technology

Introduction to the Monte Carlo method

Page: 1 of 6 Page: 1 of 6

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY

INTRODUCTION. A. Purpose

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Multi-slice Helical CT Scanning of the Chest

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

PCXMC 2.0. User s Guide. Markku Tapiovaara, Teemu Siiskonen STUK-TR 7 / NOVEMBER 2008

Manual for simulation of EB processing. Software ModeRTL

Radiation Strip Thickness Measurement Systems

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

DICOM Correction Item

C A M P E P. Standards for Accreditation of Graduate Educational Programs in Medical Physics

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.

Physics 25 Exam 3 November 3, 2009

Design and Implementation of an Institution-Wide Patient-Specific Radiation Dose

CT Traceability - Prof. Wim Dewulf, Group T - KU Leuven

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

A dosimetry technique for measuring kilovoltage cone-beam CT dose on a linear accelerator using radiotherapy equipment

Synthetic Sensing: Proximity / Distance Sensors

Clinical Photon Beams

Archimedes Palimpsest Metadata Standard XRF Extensions DRAFT

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Ionizing Radiation, Czech Republic, CMI (Czech Metrology Institute)

APMP/TCRI Key Comparison Report of Measurement of Air Kerma for Medium-energy X-Rays (APMP.RI(I)-K3)

MEDICAL IMAGING 2nd Part Computed Tomography

Information about the T9 beam line and experimental facilities

AAPM protocol for kv x-ray beam dosimetry in radiotherapy and radiobiology

Prepublication Requirements

Cargo Container X-ray Inspection Systems

Stationary digital breast tomosynthesis system with a multi-beam field emission x-ray source array

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Quality control of CT systems by automated monitoring of key performance indicators: a two-year study

The Exposure Index and Its Standardization

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

Principles of dosimetry The ionization chamber

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Diagnostic x-ray imaging relies on the attenuation of

EPA Protocols: Compliance testing of dental X-ray apparatus used for plain radiography

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

Transcription:

Patient-specific kerma-area product as an exposure estimator in computed tomography: the concept and typical values. Alexandr Malusek, Ebba Helmrot, Gudrun Alm Carlsson Department of Medical and Health Sciences Division of Radiological Sciences / Radiation Physics Faculty of Health Sciences Linköping University 21-11-11 A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 1 / 13

Introduction The concept of the patient-specific kerma-area product (PSKAP) as an exposure estimator in computed tomography (CT) was suggested by Huda 1, but no detailed information on how to evaluate this quantity in practice was given. Our aim: 1 Provide a rigorous definition of PSKAP. 2 Suggest a method for its evaluation by a CT scanner 3 Obtain typical values. 1 W. Huda, (28) Time for unification of CT dosimetry with radiography and fluoroscopy, Radiation Protection Dosimetry, Vol.128, No.2, 129 132. A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 2 / 13

Theory: Kerma-area product as a risk estimator reference plane x ray tube Kerma-area product, P KA : P KA = K air da beam axis A i,j K air,i,j A, K air,i,j where K air is air kerma A x ray tube P KA does not depend on the position of the reference plane if photons in the beam are neither scattered nor absorbed. K air 1/r 2 A r 2, where r is the distance from the focus A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 3 / 13

Theory: Integration region is patient specific beam axis reference plane iso center position 1 patient x ray tube trajectory position 2 Only the part of the beam incident on the patient contributes to P KA. Reference plane: is perpendicular to the beam axis crosses iso-center Integration region: depends on the viewing angle may contain disconnected parts A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 4 / 13

Theory: Patient-specific kerma-area product, P PSKA PKA (mgycm 2 ) 3. 2.5 2. 1.5 1..5 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 projection index The patient-specific kerma-area product is a sum of projection-specific kerma-area products P PSKA = i P KA,i A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 5 / 13

Theory: Implementation via a KAP meter front view x ray tube bowtie filter KAP meter side view couch detector array A KAP meter is a plane-parallel ionization chamber calibrated to measure P KA for the transmitted radiation. The KAP meter measures all radiation passing downstream the collimator rotates with the x-ray tube The integration region can be determined from the reconstructed image. A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 6 / 13

Theory: Projection-specific kerma-area product x a x reference plane P KA,i = t i PKL x b t i is the acquisition time for projection i x A K air da xb = t i Ṗ KL (x) dx x a = t i Ṗ KA (I ) P KL() P KA xb x a P KL(x) P KL () dx Ṗ KA (I ) is the kerma-area product rate measured by the KAP meter as a function of tube current I P KL (x) and P KL () are the kerma-length products taken at positions x and, respectively. P KL () and P KL(x) are determined during a calibration of the CT scanner. The P KA P KL () integral is evaluated separately for each projection. A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 7 / 13

Method standard CT dosimetry head phantom (R = 8 cm, H = 1 cm) Siemens SOMATOM Open CT scanner simplified formula P KA,i = t i Ṗ KL (I, x = ) 2 xc P KL (x) P KL () dx where Ṗ KA (I, x = ) is the kerma-length product rate measured at the iso-center. iso center bowtie filter x 15 mm A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 8 / 13

Method: Calibration coefficient of a WD CT 1 chamber 57 mm side view top view carbonated epoxy resin air metallic electrode Measurement at SSL for beam quality Q : N KL,Q = 24.2 mgy cm nc 1 Correction for a different beam quality Q was determined from calculated N KL N KL P KL Q = wk air ɛ/(w e /e) 9 mm w 1 mm P KL calculated analytically Q calculated via the PENELOPE Monte Carlo code from energy imparted to the air cavity, ɛ x-ray spectra were analytically filtered by an aluminum filter with a thickness from to 45 mm. A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 9 / 13

Results: Calibration coefficient of a WD CT 1 chamber count NKL / (mgy cm / nc).6.5.4.3.2.1 32 3 28 26 24 22 2 Energy spectra, 12 kv mm Al 1 mm Al 2 mm Al 3 mm Al 2 4 6 8 1 12 14 E / kev 1 2 3 4 thickness of Al / mm Energy spectra of the CT scanner filtered with, 1, 2 and 3 mm of Al for the tube voltage of 12 kv. 8 kv 1 kv 12 kv 14 kv Calibration coefficient as a function of filter thickness. Linear regression was used. Fitted lines were used to calculate correction factors for measured P KL A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 1 / 13

Results: P KL measurement iso center bowtie filter x 15 mm PKL(x) PKL() 1..8.6.4.2 8 kv 1 kv 12 kv 14 kv 5 1 15 x / mm Figure: The corrected and normalized kerma-length product as a function of distance from the iso-center. x 1 c xc xc 8 kv 1 kv 12 kv 14 kv P KL(x) P KL() dx 63.6 mm 65.6 mm 67.8 mm 68.1 mm P KL(x) P KL() dx.79.81.84.84 A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 11 / 13

Results: the patient-specific kerma-area product, P PSKA 1 1 rotation: P PSKA =.25 Gy cm 2 P PSKA = 2P KL xc beam width at the iso-center 1.2 cm x-ray tube voltage......... 12 kv tube current.............. 1 ma scanning time............. 1 s projected range x c......... 8.8 cm P KL...................... 18.8 mgy cm 2 8 rotations: P PSKA = 2. Gy cm 2 P KL (x) dx = 18.8 mgy cm 2 6.78 cm =.25 Gy cm2 P KL () pitch..................... 1 beam width at the iso-center 8 1.2 cm = 9.6 cm scanning time............. 8 1 s = 8 s P PSKA = 8.25 Gy cm 2 = 2. Gy cm 2 A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 12 / 13

Discussion To implement the method: the CT scanner must be equipped with a KAP meter the calculation procedure must be implemented in the scanner s software a calibration to determine the ratio P KL ()/P KA and the function P KL (x)/p KL () must be performed. A. Malusek, E. Helmrot, G. Alm Carlsson (LiU) Patient-specific kerma-area product... 21-11-11 13 / 13