ALPHATRAN Inverter System

Similar documents
Phase Modular Finally the benefits of Modular ups are for all

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

PowerGem Pro Uninterruptible Power Supply

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

MAJORSINE Power Inverter

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Thyristor-controlled power supplies and battery chargers

Uninterruptible Power Supply

LAP ENERGIA PARA DATACENTERS

Specification Requirements DBL 700MX and 1000MX Series UPS

Galaxy VM. Three-phase power protection. schneider-electric.com

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

4.0 UPS dedicated to ICT for unmatched energy savings

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

RIELLO ELETTRONICA. Master HP

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Model #: SMART2200CRMXL

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

TOSHIBA G /100/160/225 kva

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Uninterruptible power supplies Meissner. Efficient and reliable backup where electricity is critical to you

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Chassis, Power Supply, and Element Management

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

User Manual 1K/2K/3K Online UPS

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

1.44 kw Programmable DC Power Supplies XLN Series

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Back-UPS Pro 1300/1500 Installation and Operation

BC Pro UPS System Standby UPS System

Power Quality. Uninterruptible Power Supply

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Assembled in Florida, USA.

TMS TANK MANAGEMENT SYSTEM

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

The UPS for the highest security in industry and data centres

Eaton 93PM UPS Where aesthetics meet intelligence.

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

10000HXL31/15000HXL31/20000HXL31

User s Manual Before using the inverter, you need to read and save the safety instructions.

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

USER MANUAL Online UPS 1K/2K/3K

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USER MANUAL Online UPS 1K/2K/3K Rack

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

328 Innovation Blvd. 1 Wheaton Road, Witham

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Dell Smart-UPS 1,500 3,000 VA

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Photovoltaic Solar Energy Unit EESFB

Transcription:

ALPHATRAN System 3.5 kva - 21 kva Scalable N+1 The Next Generation in AC Telecom Power Tyco s Alphatran N+1 scalable DC to AC inverter is the latest state of the art inverter line designed to become the industry standard for critical AC power for the world s leading telecom companies. The Alphatran scalable 3.5 kva inverter power modules can be stacked in an N+1 redundant configuration for optimum reliability up to 17.5kVA. This modular scalability makes the Alphatran ideal for most applications where future power growth is anticipated. All modules are packaged into a hot swap receiver cabinet allowing rapid and safe exchange of any component without interruption to the critical load. Advanced Specifications Compliant to NEBS/Telecom industry standards. True Modular Scalability: 3.5 kva - 21 kva (3.5 kva modules). Add modules as your system grows. Parallel for N+1 redundancy or capacity. Safe hot-swap technology. Unparalleled reliability. No single points of failure. Full front accessibility. Ultra low profile: 21 kva in 24 U with static switch. Clean DC input < 30 dbrnc Precision output voltage regulation: <1% line and load Integrated static bypass for added reliability LCD status display module SNMP / Web-based monitoring (future offering) Universal voltage and frequency (User selectable via laptop computer. Computer not supplied.) International agency certifications (UL, CE, TUV)

ALPHATRAN System 3.5 kva - 21 kva Scalable N+1 System Overview and Components System Operation The plant receives 48 VDC from a DC power plant of battery bank and converts the output to precision regulated AC power (user selectable voltage and frequency). In the event that the DC is not available or out of tolerance due to a discharged battery, or the inverters are not AC Distribution Panel Maintenance Bypass Cabinet Redundant Microcontrollers Static Bypass Switch able to maintain the critical load, the system will automatically transfer to the static transfer switch and disconnect from the DC source. The static transfer switch (standard) will make a seamlessly, uninterrupted transfer from the critical load to an alternate AC power source where the inverter power was synchronized to (utility power or another protected AC source). The availability of the Alphatran N+1 on-line mode with a backup source present is greater than 99.9999%. AC Distribution Panel The AC distribution panel accommodates 20 (7 KVA system) or 24 (14 and 21 KVA systems) single pole circuit breaker positions and is available in 120 and 240 Vac versions. Note: all recommended breakers include distribution alarm monitoring contacts that take up an additional pole position. This limits the maximum number of circuit breakers if distribution alarm monitoring is to be used. The maximum number of circuit breakers that can be installed, with and without the additional alarm monitoring contact, is shown below. Maintenance Bypass Cabinet Safely and seamless transfers the output to an alternate AC source (utility power or protected AC power from another inverter or UPS system) allowing the inverter to be shut down or removed without interrupting power to the critical loads. The maintenance bypass assembly is factory wired to the inverter module when ordered as a system. Dual Independent Microcontroller Modules If the primary microcontroller module is ever compromised the secondary module continues to provide uninterrupted performance. Redundant 3.5 kva Hot Swappable Modules Permits power modules to go off line and be quickly replaced while keeping the load on inverter power. Integrated Electronic Static Transfer Switch Provides six sigma reliability by rapidly transferring the load to an alternate AC power source if DC power to the inverters is not available. Rack Mount Receiver Cabinet with Rapid Change Connector System Swap components on-line safely and rapidly with no wiring connections and without risking system performance. Telecom Grade Filtering The Alphatran is equipped with a high grade noise filter system limiting ripple current on the battery to well under required levels, as well as ensuring that radiated and conducted EMI are kept to safe levels. With Alarm Contacts System Single-Pole Double-Pole Single-Pole Double-Pole 7 KVA 20 10 10 6 14 / 21 KVA 24 12 12 8 Maximum Number of Circuit Breakers per AC Panel 2 Tyco Electronics Power Systems, Inc.

ALPHATRAN System 3.5 kva - 21 kva Scalable N+1 System Features Digital Calibration and Self Diagnostics Any drift in settings is immediately self corrected, eliminating maintenance and calibration requirements. Field Replaceable Fan Assemblies Fans can be swapped easily without system downtime. Open Frame Relay Rack All components are mounted on an industry standard 26-inch width open frame relay rack with the entire inverter plant certified for zone 4 seismic installations. Web Based Monitoring (future offering) The Alphatran monitoring system provides inverter, maintenance bypass and AC distribution status and alarms over a closed network or via the Internet serving up web pages that can be viewed with a standard browser or via SNMP or dial-up access. Accessories include environmental monitoring modules and auxiliary inputs to monitor other devices such as leak detection system, room security or any other dry contact status points. Built to Meet Industry Standards The Alphatran inverter is designed to meet the stringent regulatory qualifications demanded by telecommunications facilities. As well as meeting all major safety standards (including CE and UL), it is one of the only inverters designed to meet Network Equipment Building System (NEBS) standards - the industry benchmark for product quality and reliability. UL is a registered trademark of Underwriters Laboratories, Inc. System Block Diagram AC Bypass Input Maintenance Bypass DC Input AC Distribution Panel Modules (1-6 Modules) 3.5 kva 3.5 kva 3.5 kva 3.5 kva 3.5 kva Static Transfer Switch EMI Filter Static Transfer Switch Assembly Dry Contact Alarms RS-232 Comm. Port SNMP / WEB Monitor (optional) Tri-Layer Redundancy DC Input AC Input Controllers Static Switch AC Output 1 Dual Redundant Microcontrollers 2 N+1 Redundant Assemblies 3 Redundant AC Bypass Source (Static Switch) 1 2 3 3.5 kva Tyco Electronics Power Systems, Inc. 3

ALPHATRAN System 3.5 kva - 21 kva Scalable N+1 Alphatran Technical Specifications Input Voltage Parameter -48 Vdc (40-60 Vdc operational range) Description Output Voltage 100, 110, 115, 120, 200, 220, 230, 240 Vac (selectable via external PC configuration software) Output Frequency 50 or 60 Hz +/- 0.02% (selectable via external PC configuration software) Output Waveform High resolution PWM sine wave Technology IGBT PWM Load/Line Voltage Regulation Less than +/- 1% Static Switch Transfer Time Less than 3 ms Efficiency 88% typical (on-line mode) to 97% typical (off-line eco mode) Transient Response 5% deviation with 1 ms recovery from zero to full load Overload Capability 120% of continuous rated VA/watts at 20 C Short Circuit Current (SCC) 300% for more than 4 cycles Audible Noise Less than 50 dba EMI Emission Less than 30 dbrnc Total Harmonic Distortion Less than 1% for linear loads, less than 3% for crest factor loads up to 3:1 Monitoring Calibration Operating Temperature Operating Humidity Operating Altitude Agency Approvals Installation Finish LCD with true RMS metering, LED status display, dry contacts, RS-232, optional SNMP / Web server Digitally controlled / automatic 0 to +55 C (-40 to +75 C shipping) 0 to 90% relative, without condensation Less than 10,000 feet without derating UL/CSA 60950 (listed) and European Standard EN60950, CE, TUV, FCC class A certified 26-inch rack, floor mounted RAL 902 off white Receiver System Height 1 (inches) Receiver Cabinet Capacity (kva) Capacity (kva/kw) Number of s (min/max) 1. System width and depth = 17.0 x 18.5 inches. Power (kva/kw) DC Input (A max) Output (A at 115 Output (A at 240 Approx. System Weight (lb) Max BTU Sugg. DC Breaker (A) AC Input Breaker (A at 115 AC Input Breaker (A at 240 21.0 7.0 3.5/3.0 1 (1/2) 3.5/3.0 88 29 14.5 114 1807 200 80 40 21.0 7.0 7.0/6.0 2 (1/2) 7.0/6.0 176 58 29 182 3614 200 80 40 31.5 14.0 7.0/6.0 2 (2/4) 7.0/6.0 176 58 29 182 3614 400 150 80 31.5 14.0 10.5/9.0 3 (2/4) 10.5/9.0 265 87 43.5 241 5421 400 150 80 31.5 14.0 14.0/12.0 4 (2/4) 14.0/12.0 353 116 58 299 7227 400 150 80 42.0 21.0 10.5/9.0 3 (3/6) 10.5/12.0 265 87 43.5 241 5421 600 225 125 42.0 21.0 14.0/12.0 4 (3/6) 14.0/12.0 353 116 58 299 7227 600 225 125 42.0 21.0 17.5/15.0 5 (3/6) 17.5/15.0 441 145 72.5 357 9034 600 225 125 42.0 21.0 21.0/18.0 6 (3/6) 21.0/18.0 529 174 87 418 10,841 600 225 125 4 Tyco Electronics Power Systems, Inc.

ALPHATRAN System 3.5 kva - 21 kva Scalable N+1 Ordering Information Line to Neutral Power Systems Receiver Equipped Total Capacity 1 Comcode Capacity (kva) Output (kva) 7.0 / 3.5 kva System 408518884 7 3.5 2 1 7.0 / 7.0 kva System 408518892 7 7.0 2 2 14.0 / 7.0 kva System 408518900 14 7.0 4 2 14.0 / 10.5 kva System 408518918 14 10.5 4 3 14.0 / 14.0 kva System 408518926 14 14.0 4 4 21.0 / 10.5 kva System 408518934 21 10.5 6 3 21.0 / 14.0 kva System 408518942 21 14.0 6 4 21.0 / 17.5 kva System 408518959 21 17.5 6 5 21.0 / 21.0 kva System 408518967 21 21.0 6 6 1. Rack-mounted system with Maintenance Bypass Switch, AC Distribution and 2nd System Controller Card Line to Neutral Power Systems Spare Parts Line to Line Power Systems Line to Line Power Systems Spare Parts Max. Number of s (x3.5 kva) Spare Parts and Spare Parts Kits Comcode Description 3.5 kva Module 408518975 Module - 3.5 kva Level 1 Spare Parts Kit 408518983 fan, static transfer switch fan and AC fuses Level 2 Spare Parts Kit 408518991 s Included Spare inverter module, inverter fan, static transfer switch fan and AC fuses Level 3 Spare Parts Kit 408519007 module, inverter fan, static transfer switch fan, controller, LCD display, AC fuses and static transfer switch PCBA LCD Display 408519015 LCD display/control panel (spare) Static Switch Fan Assembly 408519023 Static switch fan assembly (includes front panel plate Module Fan Assembly 408519031 module fan assembly, (includes front panel plate) Maintenance Bypass Switch 408519049 Maintenance bypass switch Max. Number of s (x3.5 kva) Receiver Equipped Total Capacity 1 Comcode Capacity (kva) Output (kva) 7.0 / 3.5 kva System 408533888 7 3.5 2 1 7.0 / 7.0 kva System 408533896 7 7.0 2 2 14.0 / 7.0 kva System 408533905 14 7.0 4 2 14.0 / 10.5 kva System 408533913 14 10.5 4 3 14.0 / 14.0 kva System 408533921 14 14.0 4 4 21.0 / 10.5 kva System 408533938 21 10.5 6 3 21.0 / 14.0 kva System 408533946 21 14.0 6 4 21.0 / 17.5 kva System 408533954 21 17.5 6 5 21.0 / 21.0 kva System 408533962 21 21.0 6 6 1. Rack-mounted system with Maintenance Bypass Switch, AC Distribution and 2nd System Controller Card s Included Spare Parts and Spare Parts Kits Comcode Description Level 3 Spare Parts Kit 408533970 Includes: Level 2 spares, alarm relay card, LCD display panel, system controller, L-L static switch PCB Tyco Electronics Power Systems, Inc. 5

ALPHATRAN System 3.5 kva - 21 kva Scalable N+1 Ordering Information (continued) Circuit Breakers All circuit breakers listed here are equipped with alarm contacts. Circuit Breakers (10,000 AIR) Comcode 15A Single Pole 406938688 20A Single Pole 406938696 25A Single Pole 406938704 30A Single Pole 406938712 40A Single Pole 406938738 50A Single Pole 406938753 20A Double Pole 406938779 Circuit Breakers (22,000 AIR) Comcode 15A Single Pole 407247337 25A Single Pole 407247386 30A Single Pole 407247394 15A Double Pole 407250034 20A Double Pole 407250042 25A Double Pole 407250059 30A Double Pole 407250067 40A Double Pole 407250083 50A Double Pole 407250109 70A Double Pole 408519631 100A Double Pole 408519601 125A Double Pole 408519627 Europe, Middle-East and Africa Headquarters Tyco Electronics (UK) Ltd Tel: +44 1344 469 300, Fax: +44 1344 469 301 World Wide Headquarters Tyco Electronics Power Systems, Inc. 3000 Skyline Drive, Mesquite, TX 75149, USA +1-800-843-1797 (Outside U.S.A.: +1-972-284-2626) power.tycoelectronics.com e-mail: techsupport1@tycoelectronics.com Caribbean-Latin America-Brazil Headquarters Tyco Electronics Power Systems Tel: +56 2 209 8211, Fax: +56 2 223 1477 Asia-Pacific Headquarters Tyco Electronics Singapore Pte Ltd Tel: +65 6416 4283, Fax: +65 6416 4299 India Tyco Electronics Systems India Pte Ltd Tel: +91 80 841 1633 x3001 Tyco Electronics Corporation reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 2005 Tyco Electronics Power Systems, Inc., (Mesquite, Texas) All International Rights Reserved. Printed in U.S.A. DS03-004 Rev 5 6 Tyco Electronics Power Systems, Inc.