SSM Floor Heating Manifold

Similar documents
Automatic Bypass Control AVDO

DEVIreg 330 (+5 to +45 C)

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

stainless steel pre-assembled manifolds

Installation Guide. DEVIreg 530. Electronic Thermostat.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

kymanual or Automatic - it s your Choice

Technical catalogue convectors POLAND 2012

Data sheet ECC 12 and 22

HERZ-Thermal Actuators

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Danfoss Link Mobile Phone Butler

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Thermostatic element RAVV for 2-way valves

A/C refrigerant system, overview

Automatic control equipment for HVAC systems

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Conlift1, Conlift2, Conlift2 ph+

Automatic balancing valves ASV

Valve range. To be precise.

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Series TMM Axial Piston Motor. Technical Information

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

HEAT INTERFACE UNITS (Modular)

Single sub-base valve

Joystick PVRES and PVREL. Technical Information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Powers Controls TH 192 S Single Temperature Room Thermostat

3/2-way Mini Solenoid Valve

Data sheet Thermostatic sensors type RA 2000

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Damcos. LPU-D for double-acting actuator. Product Data Sheet November 2014 SD E06

3/2-way Solenoid Valve, direct-acting, NC or NO

Split units TH with hermetic compressors

SERVOMECH Linear Actuators

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SOLENOID VALVES AND PNEUMATIC VALVES

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Thermostatic valve Type AVTA

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

4/2-Way Pneumatic Solenoid Valve

Overview of types. Technical data

REGULATORS 175/153 Series

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Product catalogue, pipe and sewer cleaning systems

Wiring Diagram. Diplomat 400V 3N.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

MANTA Piston Distributor for Oil and Fluid Grease

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Thermostatic Actuators

Electro-Pneumatic Bus Door Control Mechanism

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Electric Rotary Actuator - On/Off or programmable control actuator

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

Proportional pressure regulators VPPE

Guidelines for operation of minimum flow control valves

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Low-H2O valves Y EARS

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Solenoid valves Type EVU

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Unit 24: Applications of Pneumatics and Hydraulics

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

V5001S. Kombi-S Shutoff Valve. Product specification sheet

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

WE-350 Series ¼ Turn Electric Actuator

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

3/2-way pneumatic cartridge solenoid valve

Basic Hydraulics and Pneumatics

COMBIMASS. Technical Data COMBIMASS eco-bio +

Series description: Wilo-Yonos MAXO

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

Adjustable room thermostat for heating only or cooling only systems

ECOplus Solar Cylinder

Hydraulic Control Solutions

Valve systems Base plates, according to standard ISO Brochure

G1/4 Q8. Standard with biased position

Refrigeration Air Dryers. Catalogue

Transcription:

Application The manifold consists of a supply and return manifold. The supply manifold includes possibility for individual shut-off of each circuit on flowmeter or shut-off valve. The return manifold is equipped with integrated Danfoss presetting valves securing optimal hydraulic balance in the system. The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters. The SSM manifold is used for controlling water flow in under floor heating systems. Each tube of the floor heating system is connected to the manifold, thus making it possible to control water flow or heat supply to each room in the building individually. The manifold is supplied in modules of up to 12 outlets. Ball valves are available as an option for positive shut-off between manifold and system. The SSM manifold is supplied with a manual airvent and a purge valve. Ordering Description Type Code no. Manifold set 2+2, with flowmeter SSM-2F 088U0752 Manifold set 3+3, with flowmeter SSM-3F 088U0753 Manifold set 4+4, with flowmeter SSM-4F 088U0754 Manifold set 5+5, with flowmeter SSM-5F 088U0755 Manifold set 6+6, with flowmeter SSM-6F 088U0756 Manifold set 7+7, with flowmeter SSM-7F 088U0757 Manifold set 8+8, with flowmeter SSM-8F 088U0758 Manifold set 9+9, with flowmeter SSM-9F 088U0759 Manifold set 10+10, with flowmeter SSM-10F 088U0760 Manifold set 11+11, with flowmeter SSM-11F 088U0761 Manifold set 12+12, with flowmeter SSM-12F 088U0762 Manifold set 2+2 SSM-2 088U0802 Manifold set 3+3 SSM-3 088U0803 Manifold set 4+4 SSM-4 088U0804 Manifold set 5+5 SSM-5 088U0805 Manifold set 6+6 SSM-6 088U0806 Manifold set 7+7 SSM-7 088U0807 Manifold set 8+8 SSM-8 088U0808 Manifold set 9+9 SSM-9 088U0809 Manifold set 10+10 SSM-10 088U0810 Manifold set 11+11 SSM-11 088U0811 Manifold set 12+12 SSM-12 088U0812 VDUDW202 Danfoss FHH 2016.05 1

Accessories Description Type Code no. Mounting brackets - set FHF-MB 088U0585 2 x ball valve 1 - for connection to manifold and for blocking of floor heating system 1 x thermometer 0-60 C Ø35mm - for flow/return temperature measurement FHF-BV FHD-T 088U0586 088U0029 Union, 1-088U0820 Thermal actuator, 24V, NC, Danfoss RA connection to valve TWA-A 088H3110 Thermal actuator, 230V, NC, Danfoss RA connection to valve TWA-A 088H3112 Thermal actuator, 24V, NC, with end switch, Danfoss RA connection to valve TWA-A 088H3114 Compression fittings Description Type Code no. Compression fittings for PEX tubing in accordance with ISO 15875. Max working pressure: 6 bar Test pressure: 10 bar Max. flow temperature: 95 C G ¾ internal thread Max. flow temperature given by the tube manufacturer must not be exceeded. Compression fittings for ALUPEX tubing. Max working pressure: 6 bar Test pressure: 10 bar Max flow temperature: 95 C G ¾ Internal thread Max flow temperature given by the tube manufacturer must not be exceeded. 12x2 mm 13x2 mm 14x2 mm 013G4152 013G4153 013G4154 15x2.5 mm 013G4155 16x1.5 mm 013G4157 16x2 mm 013G4156 1) 16x2.2 mm 013G4163 17x2 mm 18x2 mm 013G4162 013G4158 18x2.5 mm 013G4159 20x2 mm 013G4160 20x2.25 mm 013G4093 1) 20x2.5 mm 013G4161 12x2 mm 14x2 mm 013G4182 013G4184 15x2.5 mm 013G4185 16x2 mm 013G4186 2) 16x2.25 mm 013G4187 18x2 mm 20x2 mm 1) Compression fittings also suitable for PERT tubing in accordance with ISO 15875. 2) Compression fittings also suitable for PERT/ALU/PERT tubing. 013G4188 013G4190 20x2.25 mm 013G4093 2) 20x2.5 mm 013G4191 2 Danfoss FHH 2016.05 VDUDW202

Capacity/commissioning The pre-setting of the manifold valves determines the flow in the floor heating tubes and is therefore an important factor for obtaining optimal hydraulic balance in the system. A correct hydraulic balance is important if optimal comfort shall be achieved with a minimum of energy consumption and is easily carried out following the example shown below. Example Room 1: 1. Determine longest tube/largest room 25 m 2 2. Desired cooling (ΔT) 5 C (typical) 3. Determine heat requirement for the room 50 W/m 2 4. Conversion factor 1.16 5. Calculation of flow for the room Q (l/h) = 50 W/m2 x 25 m 2 = 216 l/h 5 C x 1.16 Room 2: 6. Determine area for the next room 15 m 2 7. Calculation of flow for the room (ΔT and heat requirement is assumed identical for the rooms in this case) Q (l/h) = 50 W/m2 x 15 m 2 = 129 l/h 5 C x 1.16 Manifold, with flowmeter Pre-setting: Room 1 N Room 2 5 Manifold, without flowmeter Pre-setting: Room 1 N Room 2 6 VDUDW202 Danfoss Danfoss FHH 2016.05 3

Presetting the manifold valves The diagram shows the capacities for each heating circuit at different presettings of the manifold valves. Based on the above calculations and capacity diagram each manifold valve is preset by rotating the red ring until the correct value on the ring is in-line with the sight mark on the valve. Operation conditions Supply manifold with flowmeter Supply manifold without flowmeter Max differential pressure 0.6 bar 0.6 bar Max working pressure 6 bar 10 bar Max test pressure 10 bar 16 bar Max flow temperature 90 C 90 C System layout 4 Danfoss FHH 2016.05 VDUDW202

Dimensions 41 L1 50 213 359 64 Type 2+2 3+3 4+4 5+5 6+6 7+7 8+8 9+9 10+10 11+11 12+12 L1 (mm) 190 240 290 340 390 440 490 540 590 640 690 VDUDW202 Danfoss Danfoss FHH 2016.05 5

Danfoss A/S Floor Heating Hydronics Ulvehavevej 61 DK-7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 heating@danfoss.com www.floorheating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 6 Danfoss Danfoss FHH 2016.05 VDUDW202