Valve range. To be precise.

Size: px
Start display at page:

Download "Valve range. To be precise."

Transcription

1 Valve range To be precise.

2 Thermostatic room temperature control Thermostatic head K with built-in sensor. Graduation cap white RAL 9016, Graduation cap chrome-plated, Graduation cap anthracite grey RAL 7016, Graduation cap light grey RAL 7035 and Graduation cap dusty grey RAL Thermostatic head VD with connection cover for radiators with integrated valves, from the DESIGN LINE range. Thermostatic head WK Angle form for radiators with integrated valves. Thermostatic head VK with clamp, for radiators with integrated valves. standard with zero position with anti-theft protection Thermostatic head DX with built-in sensor. Graduation cap white RAL 9016, Graduation cap chrome-plated, Graduation cap graphite grey RAL 7024, Graduation cap light grey RAL 7035 and Graduation cap dusty grey RAL Thermostatic head B secured public building model. Thermostatic head D Thermostatic head K anti-theft ring anti-theft device with two screws with zero position for indoor swimming-pools model for public buildings Thermostatic head F Remote dial. with built-in sensor with remote sensor for indoor swimming-pools Thermostatic head K with remote sensor. anti-theft ring anti-theft device with two screws with zero position for indoor swimming-pools model for public buildings With direct connection to valves from other manufacturers K for Danfoss RAVL K for Danfoss RAV VK for Danfoss RA standard with zero position with anti-theft protection D for Danfoss RA K for Vaillant D for Herz M 28 x 1.5

3 Standard for two-pipe pumped heating systems. with particularly low resistance for gravity and conventional single-pipe heating systems. Body in angle, straight, axial and double-angle form, made out of gunmetal and nickel-plated. Models in DN 10 DN 32 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN LINE range for angle and straight NW 10 NW 15 with female thread. Duolux Valve for radiators with lateral two-point connection. Models for single and two-pipe systems. E-Z Valve including immersion pipe for radiators with bottom single-point connection. Models for single and two-pipe systems. Body made of gunmetal, nickel-plated. Single pipe valve with immersion pipe for radiators with a lateral single-point connection. V-exakt with exact pre-setting for heating systems with a normal to higher temperature spread. F-exakt with exact pre-setting for heating systems with low mass flows or large-scale temperature spreads, e.g. for remote heating systems. Body in angled, straight, axial and doubleangle form, made out of gunmetal and nickelplated. Models in DN 10 DN 20 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN-LINE range for angle and straight NW 10 NW 15 with female thread. E-Z System Valve for radiators with lateral two-point connection. Can be changed from single-pipe to two-pipe operation. Body made of gunmetal, nickelplated. Multilux for radiators with low-positioned, two-point connection, distance from center to center 50 mm. For pre-setting and draining. Available in angle and straight models for both single and two-pipe systems. Connection R 1 /2 and G 3 /4. Can be fitted with covers from the DESIGN LINE range in white and chrome.

4 Electric/electronic room temperature control Time Adaptor Room temperature controllers Radio system for floor heating system E-Pro Time Adaptor for Thermostatic Valves A time adaptor designed to regulate room temperatures in tune with specific times of the day and night. The device is fitted between the valve and the thermostatic head. HEIMEIER thermostatic heads, which are already available, can continue to be used after fitting of the time adaptor. Room thermostat Two-point room thermostat for thermal actuators EMO T/ EMOtec. Thermostat P Two-point room thermostat with 7-day switch clock for thermal actuators EMO T/EMOtec. Thermostat E 1 Proportional room thermostat for motorized actuators EMO 1. Thermostat E 3 The 3-point room thermostat for motorized actuators EMO 3. Radiocontrol F consisting of room transmitter and central unit. For the individual room temperature control of floor, wall or ceiling heating systems or cooling systems. Thermal actuators Motorized actuators Motorized actuators EMO T Two-point actuator for heating, ventilation and air-conditioning systems. EMOtec Two-point actuator for floor heating systems. With position indicator in NC version. EMO 1 Proportional actuator for heating, ventilation and air-conditioning systems. EMO 3 Three-point actuator for heating, ventilation and air-conditioning systems. EMO 3 / 230 "3-point 230 V" input signal. Ideally suited for the regulating of the supply pipe temperature. EMO EIB Proportional actuator for direct connection to the European Installation Bus EMOLON Proportional actuator for use in LonWorks networks.

5 Special fittings Three-way valves Three-way reversing valve for distributing flow rates in heating and cooling systems. Three-way mixing valve with and without pre-setting feature for mixing flow rates in heating and cooling systems. Body made of gunmetal. For all HEIMEIER thermostatic heads and actuators. Thermostatic head K with contact or immersion sensor Use of the sensor in conjunction with heat conducting base as a contact sensor or with an immersion sleeve as an immersion sensor. Thermostatic head with spiral-shaped immersion sensor without immersion sleeve. Sealed to the capillary tube by means of clamping joint. Floor control set for the constant control of the supply temperature in combined floor and radiator heating systems. Return temperature limiter RTL e. g. for the temperature control of smaller floor areas. Body in angle and straight versions, made of gunmetal, nickel-plated. Connection R 1 /2 and G 3 /4. Flush individual room control for floor heating systems Multibox K with thermostatic valve. Multibox RTL with return temperature limiter. Multibox K-RTL with thermostatic valve and return temperature limiter. Models in white or chrome. Multibox F with thermostatic valve. Multibox C/E with thermostatic inserts for actuators or remote dial. Multibox C/RTL with interior return temperature limiter. Models available in white. Double connection fittings for radiators with integrated valves Vekolux Double connection fitting with drain-off facility. Versions for single and two-pipe systems. Can be fitted with covers in white from the DESIGN LINE range. Vekotec Double connection fitting. Models for two-pipe systems. Body in angle and straight form and made of gunmetal, nickel-plated. Connection R 1 /2 and G 3 /4.

6 Manual valves Manual radiator valve Manual valves for floor heating system Mikrotherm with pre-setting. With hand wheel cap made of white plastic. Body in angle and straight form, made of gunmetal and nickel-plated. NW 10 NW 32. Manual valves and also lockshields for heating manifolds, universal connection possibilities on both sides, body made of gunmetal. Radiator lockshield Radiator lockshield Regulux for shutting off, pre-setting, draining and filling. Models in DN 10 DN 20 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN LINE range for angle and straight versions NW 10 NW 15 with female thread. Regutec for shutting off and controlling. Models in DN 10 DN 20 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN LINE range for angle and straight versions NW 10 NW 15.

7 Shut-off valves Ball valve for heating systems Pump ball valve for heating systems Drinking Water Ball Valve Globo H Body and ball made of gunmetal. Models available as DN 10 DN 50 with a female thread, DN 15 DN 40 with a onesided male thread and DN with press connection. Thermometer in red or blue as an accessory, can be upgraded by exchanging the locking cap. Can be fitted with heat insulating shell. Globo P Globo P-S with gravity brake. Body and ball made of gunmetal Models available as 1 x 1, 1 1 /4 x1 1 /4, 1 1 /4 x 1, with 28 mm x 1 and 35 x 1 1 /4 press connections. Thermometer in red or blue as an accessory, can be upgraded by exchanging the locking cap. Can be fitted with heat insulating shell. Globo D Body and ball made of gunmetal. Models DN 15 - DN 32 with female thread and press connection. Thermometer in green as an accessory, can be upgraded by exchanging the locking cap. Can be fitted with heat insulating shell. Filling and draining ball valve Differential pressure overflow valve Globo KFE with locking cap or with threaded hose coupling and locking cap. Body made of brass and brass nickel-plated. Models ranging from NW 10 NW 20. Hydrolux Proportionally-operating differential pressure overflow valve for installation in pumped heating systems. With clearly visible display of setting values. Models with female thread or fitting ranging from NW 20 NW 32.

8 About us With its thermostatic valve, HEIMEIER has attained a leading position worldwide. The K head is the best-selling thermostatic head in the world. In Germany, the largest thermostatic valve market of all, almost every second thermostatic valve installed in recent years came from HEIMEIER. A great success story which began when Theodor Heimeier founded the company in the Westphalian town of Lippstadt in In the 1950s the company started specializing in valves for heating systems. The tandem valve Mikrotherm developed during this phase was the first great classic from HEIMEIER. The final breakthrough came with the thermostatic valve with an incompressible sensor, corrosion-resistant gunmetal body and the HEIMEIER adaptor M 30 x 1.5 presented in These three typical features have been retained till this day a decisive reason for the triumphal march of the HEIMEIER thermostatic valve, which has also always been ranked first in product tests for the past 20 years. At the German testing institution, Stiftung Warentest, it was given the mark Very good four times in a row. Apart from the thermostatic valves for almost all conceivable requirements the current range includes more than 120 different thermostatic valve bodies on which the over 40 different thermostatic heads can be mounted HEIMEIER offers an extensive assortment of actuators, room thermostats, special valves, manual valves and shut-off valves. HEIMEIER has belonged to the British group IMI plc since the middle of the 1990s. In this constellation HEIMEIER has become a major global player on international markets as well. Today, more than 30 per cent of the product range for heating and airconditioning systems for our export business are manufactured at the production site in the Westphalian town of Erwitte. To be precise. Valve range Printed on paper bleached without the use of chlorine / Subject to technical alterations. Theodor Heimeier Metallwerk GmbH Postfach 1124, Erwitte, Germany Telephone Fax

Mikrotherm. Manual radiator valves. To be precise.

Mikrotherm. Manual radiator valves. To be precise. Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.

More information

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN

More information

Data sheet Thermostatic sensors type RA 2000

Data sheet Thermostatic sensors type RA 2000 Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating

More information

Thermostats. Technical information

Thermostats. Technical information Technical information Function: Oventrop thermostats and thermostatic valves are proportional regulators working without auxiliary energy. They regulate the room temperature by varying the flow volume

More information

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

EMO T. Thermal actuator for heating, ventilation and air conditioning systems EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE EMO T Description The EMO T thermal

More information

Low-H2O valves Y EARS

Low-H2O valves Y EARS Low-O valves 0 Y EARS Pre-settable valves Why a balancing thermostatic radiator valve? Due to the application of the specially designed Jaga and Jaga Danfoss pre-settable Trv s, the flowing water amount

More information

Radiator valve accessories 1-25-5

Radiator valve accessories 1-25-5 TOUR & ANDERSSON HYDRONICS AB Certification of Registration Number 2125 and 2125 M Certified by SP QUALITY AND ENVIRONMENT SYSTEM Radiator valve accessories 1-25-5 2001.04 1 Contents Accessories Presetting

More information

Globo P. Ball valves Pump ball valve made of gunmetal

Globo P. Ball valves Pump ball valve made of gunmetal Globo Ball valves ump ball valve made of gunmetal IMI EIMEIER / Shut-off valves / Globo Globo Globo and Globo -S are used in pump warm water heating systems for direct connection to circulating pumps with

More information

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4 Henco Snelselectie kaart EN IMPORTANT! Before starting work the fitter must carefully read this installation and operation manual, understand and observe its conditions. The water floor heating control

More information

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Application Integrated valves, type RA-N (013G0372) and RA- U (013G0373), with built-in presetting are designed for incorporation

More information

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application Integrated valves, type RA-N (013G1382) and RA- U (013G1383), with built-in presetting are designed for

More information

Thermostatic Actuators

Thermostatic Actuators 2 111 EN 215-1 RTN51 with remote sensor RTN81 with remote adjuster Thermostatic Actuators for radiator valves VDN, VEN, VUN, VPD and VPE RTN51 RTN81 Self-acting, without auxiliary power High-quality fluid-filled

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

stainless steel pre-assembled manifolds

stainless steel pre-assembled manifolds TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss. DOMESTIC HEATING CONTROLS ARE EASY PART 5 - RADIATOR THERMOSTATS Fig.1. RAS-C 2 and RAS-D 2 radiator thermostats with RLV-D lockshield valve Radiator Thermostats (TRVs), the original and straight forward

More information

1. Geo Vertical 2. Geo Horizontal

1. Geo Vertical 2. Geo Horizontal 1 2 1. Geo Vertical 2. Geo Horizontal 1 2 3 1. Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate Geo Vertical 47 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex The information in this price list is correct at the time of printing. Jaga reserves the right to change

More information

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Data Sheet Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Application RAS-C² thermostatic sensor RA-FN angle valve The RAS-C² thermostatic sensor is a selfactuating proportional

More information

Technical catalogue convectors POLAND 2012

Technical catalogue convectors POLAND 2012 Technical catalogue convectors POLAND 2012 index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Please refer to the chapters below for detailed information about all aspects of the products usage.

Please refer to the chapters below for detailed information about all aspects of the products usage. EUR_STELLAZ Wall Radiator Thermostat Valve Control Firmware Version : 0.4 Quick Start S This device is a wireless sensor. All operation is performed using the little button behind the round hole in the

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Brochure 2012-2013.EX

Brochure 2012-2013.EX CLIMA CANAL Brochure 2012-2013.EX CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

Radio controlled, programmable radiator thermostat RA PLUS-w

Radio controlled, programmable radiator thermostat RA PLUS-w Data Sheet Radio controlled, programmable radiator thermostat RA PLUS-w Application RA-PLUS-w is a radio controlled radiator thermostat that enables users to lower the individual room temperature by approx.

More information

AFE424 SERVICE PARTS

AFE424 SERVICE PARTS This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured

More information

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data V1810 Alwa-Kombi-4 Circulation throttle valve Product data Alwa-Kombi-4 with internal threads Design The Alwa-Kombi-4 valve consists of: Valve housing in straight pattern with internal threads to ISO 7

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

1. Taboe Sani 2. Taboe 3. Taboe Freestanding 1 2 3 1. Taboe Sani 2. Taboe 3. Taboe Freestanding 72 1 2 1. Taboe Sani Single 2. Taboe Sani Double 74 Taboe Sani 75 Taboe Sani Dimensions TSSW_Taboe Sani Single Wall Connections Code: 1 number = flow

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

www.the Floor Heating Warehouse.co.uk

www.the Floor Heating Warehouse.co.uk www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating

More information

Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.

Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts. Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1

More information

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVI is self-acting thermostatic actuator primarily for use for temperature control

More information

Frequently Asked Questions

Frequently Asked Questions What is a Thermostatic Radiator Valve? TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.they should

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

» WEH HVAC-R CONNECTORS

» WEH HVAC-R CONNECTORS » WEH HVAC-R CONNECTORS Filling, evacuating and testing of refrigeration and air conditioning components BRIEF OVERVIEW 2015 WEH - We Engineer Hightech OVERVIEW» WEH HVAC-R Connectors simplify workflows

More information

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good. TA-FUS1ON Fully adjustable Kvs control and balancing valves. That s just two good. Supported by the Reece hvac-r network. Through our 36 stores around Australia, Reece hvac-r is committed to supporting

More information

Thermostatic element RAVV for 2-way valves

Thermostatic element RAVV for 2-way valves Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

E v e r i n c r e a s i n g i n n o v a t i o n. R A 2 0 0 0 R a n g e. C o m m e r c i a l T R V s

E v e r i n c r e a s i n g i n n o v a t i o n. R A 2 0 0 0 R a n g e. C o m m e r c i a l T R V s E v e r i n c r e a s i n g i n n o v a t i o n R A 2 0 0 0 R a n g e C o m m e r c i a l T R V s Contact Details Telephone & Fax Numbers Reception T 0845-1217 400 F 0845-1217 515 UK Sales T 0845-1217

More information

STABITHERM INSTALLATION & SERVICE BOOKLET

STABITHERM INSTALLATION & SERVICE BOOKLET STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow

More information

V5001S. Kombi-S Shutoff Valve. Product specification sheet

V5001S. Kombi-S Shutoff Valve. Product specification sheet V5001S Kombi-S Shutoff Valve Product specification sheet Application The V5001S Kombi-S shutoff valve is used to shutoff pipelines in residential or commercial hydronic heating and cooling systems. It

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / [email protected] / +31 183 639193

SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / info@superyachtspares.com / +31 183 639193 Nozzles and portable monitors Rosenbauer - Nozzles and portable monitors EN Maximum extinguishing effect. Minimal water consumption. The Rosenbauer nozzle enables the manual adjustment of the water flow

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Product catalogue, pipe and sewer cleaning systems

Product catalogue, pipe and sewer cleaning systems Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013 ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Zenith Solar thermal 4.5m pump station Installation manual

Zenith Solar thermal 4.5m pump station Installation manual Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.

More information

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K The Die competent Kompetenzmarke brand for für energy Energiesparsysteme saving systems Conventional gas fired boilers open vented / sealed unvented CGU-2 / CGU-2K CGG-2 / CGG-2K NEW The next generation

More information

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions RVR Hybrid System Controller Installation Instructions 1 Introduction to Hybrid Systems The RVR Hybrid system uses a combination of the Immergas Audax range of heat pumps with gas or oil boilers to create

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

HAZUBA. HAZUBA AG Rainstrasse 17 4528 Zuchwil T 032 685 88 88 F 032 685 88 89 [email protected] 06/14

HAZUBA. HAZUBA AG Rainstrasse 17 4528 Zuchwil T 032 685 88 88 F 032 685 88 89 info@hazuba.ch 06/14 06/14 NEW BNC 002 BK 29.- CHF This Braun travel alarm clock measures 56mm x 56mm x 31mm and is available in two colours. It has an easy to read dial layout, crescendo alarm and a quiet German precision

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

112039.00 224500 EMERGENCY PLUMBING FIXTURES

112039.00 224500 EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following emergency plumbing fixtures: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Hand-held drench hoses. 5. Combination

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50 11 COOLING SYSTEM SERVICE INFORMATION------------------------------------------------ 11-1 TROUBLESHOOTING----------------------------------------------------- 11-1 RADIATOR ------------------------------------------------------------------

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

swimming pool accessories

swimming pool accessories 76 swimming pool accessories 77 Dolphin pool cleaners Dolphin Plus Battery Cordless pool cleaner with lithium ion battery Cleans the pool in 1.5 hours Special programs Clogged filter bag indicator Incl.

More information

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities. SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19) 19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios

More information

RADIATOR VALVE. type m72. Page 1

RADIATOR VALVE. type m72. Page 1 RADIATOR VALVE type m72 The m72 AHA radiator valve is intended for use with pump-type hot water systems. It is constructed of AMETAL, brass and heat resistant plastic. The handwheel is manufactured from

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Operating instructions

Operating instructions Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Cooling system components, servicing

Cooling system components, servicing 19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap

More information

RF 1. Contents: Connecting diagram. Detailed information:

RF 1. Contents: Connecting diagram. Detailed information: Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)

More information

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING 0A-GB THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING SERIES SD - CD - GA MAIN CHARACTERISTICS - Available in the versions: Standard With Remote Sensor With Remote

More information

Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.

Buy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts. Karcher Model:K 520M /CDN ( 59559150 ) - Parts Section:1.0 PIECE PARTS Page 1 of 16 1 50690940 1 COVER 2 50319770 1 COVER / 1.069-937.0 2 50312410 1 COVER 4 40503340 1 CHASSIS 5 51052230 1 AXLE 6 53215050

More information

2003 ACCORD - Automatic Transmission Removal

2003 ACCORD - Automatic Transmission Removal 2003 ACCORD - Automatic Transmission Removal Special Tools Required Engine support hanger, A and Reds AAR-T-12566 Engine hanger balancer bar VSB02C000019 Front subframe adapter VSB02C000016 These special

More information

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS.  Construction Automotive Industry DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification

More information

Industrial infrared heater IR For premises with large volumes and high ceilings

Industrial infrared heater IR For premises with large volumes and high ceilings 3 3000 6000 W Electrical heat 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information