Product Brochure. TANK INDUSTRIES WaterStorageSolutions

Similar documents
The minimum reinforcement for the stem wall is the placement of:

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

PANELIZED HOME INSTALLATION GUIDELINE

Preformed Metal Roofing and Siding

STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Installation Instructions

SECTION GROUND WATER STORAGE TANKS

Dock Hardware & Accessory Products Catalog

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

DENVER MODEL 30 X 30 SPECIFICATIONS

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Residential Deck Safety, Construction, and Repair

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

SERVICES OFFERED QUALITY & COMPLIANCE


Since HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas Ph: Fax:

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

COLORADO MODEL. 35 x 65 SPECIFICATIONS

INSTALLATION. General. Important Note. Design. Transport

swimming pool accessories

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

HOPLEYS OPENWEBSTEELJOISTS

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

Fixed Vertical Access Ladders

Instruction Manual 19/9/01. Flat Roof Carport

If stepping is required, step at 180mm as seen in this picture.

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Preface nivtec.com 3

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Fire Collars For Plastic Pipe Penetration

ATLANTA MODEL SPECIFICATIONS

Residential Inspection Guidelines

HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING

Roof Curbs, Extensions and Equipment Supports

HORIZONTAL INSTALLATION

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Leaky Homes Financial Assistance Package (FAP) Repair plan example

PB301 July Lightweight Building Solutions. Bushfire Protection.

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Clad Direct Glaze Window Installation Instructions

Timber Decks. Technical Note. March 2007

Chapter 3 Pre-Installation, Foundations and Piers

Saferand easierinstallation

Mechanical arms, belts and sheets

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Residential Decks. Planning and Development Services Department

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

UBBINK SOLAR IN-ROOF SYSTEM

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

19" Open Rack for Network and Cabling Management

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

SECTION STORM DRAINAGE SYSTEM

Uncovered Decks & Porches

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Mark Cramer Inspection Services, Inc.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

How to build a Pizza Oven in 4 days

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

EDW + FS, VS, VSE, GGL, GGU, GHL. EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS

V80 HEAD DETAIL - SECTION VIEW DRAWING SCALE 1:2. Dwg. No. V mm min. 85mm. 72mm 95mm 65mm. 26mm. 10mm 60mm 75mm. 135mm.

PART 1 GENERAL 1.1 SECTION INCLUDES

INSTALLATION OF A BAY WINDOW

Syphonic Roof Drainage

LAYING BLOCK AND BRICK

Passive Fire Protection

Installation Instructions

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

GreenGuard Housewrap Installation Guide

POST AND FRAME STRUCTURES (Pole Barns)

How To Build A Gambrel Roof And A Gable End Roof

Partitioning & Ceiling Product Information

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

FLAT ROOF BOX SPAN CARPORTS

Superform Products Ltd.

Best Barns USA Assembly Book

Chapter 10 - Scaffolding Systems

March 14, Installation of Bay, Bow and Garden Windows

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Brick Veneer Construction

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Fall Protection Solutions

James M. Pleasants Company

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Embedded Parts Introduction - Anchors


Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

Transcription:

Product Brochure TANK INDUSTRIES WaterStorageSolutions

2 Water tanks for Australia - Built by Australians WATER STORAGE TANKS Tank Industries manufactures high quality, cost-effective modular water tanks for the fire fighting/sprinkler industry and water supply markets. A wholly-owned subsidiary of Hunt Engineers & Staff Pty Ltd, the company is dedicated to high quality and committed to service. Tank Industries manufactures, supplies and installs water tanks for customers across Australia and in many overseas markets. Service and maintenance contracts can be tailored precisely to customer needs and we can provide associated tank work such as foundations, towers and pump houses. A total project package can be undertaken, with complex engineering design and technical support. Tank Industries will continue the pursuit of excellence and the development of successful long-term relationships with a growing network of customers and distributors, while continuing to develop product range to meet the needs of the marketplace.

3 H.S. SERIES CIRCULAR GALVANISED STEEL BOLTED STORAGE TANK Tanks comprise of: Wall and floor sheets in Galvabond G2 Z275 to AS1397, prefabricated panels with all vertical steel framework, hoops, cleats, stitching straps, internal/external ladders and extended hand rail hot dip galvanised. All hoop joining bolts are M10 High Tensile steel, all others will be M10, mechanically galvanised steel. will be colorbond steel, mounted to the side of the tank. All pipe work penetrations are cleaned and sealed with a protective coating, all flanged pipework connections to the tank are fastened with galvanised steel bolts and nuts. A lockable safety cage and intermediate platform is provided on each tank, where the tank height is 6.0m or above, to AS1657. Tank Industries, with the support of Hunt Engineering & Staff P/L and its resources, is able to produce cost effective tanks of standard or custom design, in a choice of materials and finishes. Malthoid damp course membrane is layered between tank floor and foundation. Gasket material between all sheet joints are PVC High Density Foam, with a minimum thickness of 6.00mm and all sealants are high strength PVR elastomer, suitable for potable water. Tank Foundations The tank is erected on a reinforced concrete ring beam to the tank manufacturers design. The internal area of the ring beam, is filled and compacted to a depth as required by the relevant Australian Standards. The roof is low pitch construction with Galvabond open web beams, purlins and brackets, including a 600mm square manhole, cover and safety platform. Roof materials are Dualclad Zincalume sheets, fastened with Tek Screws. Tank level indicator will be a ball float type, black numbers and letters against a white background, E for empty at the top and F for full at the bottom. Indicator frame and brackets

4 Dedication to high quality and service has always been the philosophy and the basis for the success of Tank Industries. L SERIES STEEL BOLTED LINER TANKS Our range of liner type tanks offer an economic alternative to other tanks in this brochure. These tanks are suitable for fire water storage, station or property use, town water supply - potable water, agriculture, aquaculture, process, trade waste or marine waste. All liners used are rated for use with potable water, AS4020. These tanks are designed and manufactured from galvanised sheeting, pre-punched for easy erection. Horizontal circular stiffening is by galvanised angle hoop type rings. The tank is erected with external upright angle supports, or double row bolted lap joints on a concrete ring or slab and, the inner tank floor comprises compacted sand. This ensures smooth finish to the inside walls and floor of the tank. Geotextile underlay is fitted to the underside of the liner for additional protection. Liners can be supplied to offer up to a 10 year warranty. (Based on application). The liner is full height, with overlap and secured on the top edge of each tank with eyelets.

5 GALVANISED RP-GALV SERIES STEEL RECTANGULAR PANEL TANKS As approved by Tank Industries engineers. RP-Galv RP Rectangle Panel Tanks are designed to have construction method which has the flexibility to meet all customer applications. RP Tank final sizing and dimensions can be designed to fit into any difficult application or can be manufactured to replace existing tanks in tight locations that are no longer easily accessable. Tank panels externally bolted with M10 high tensile nuts and bolts. Internally bolted design options are also available. Sealing gaskets are high density PVC 6mm thick and compressible to minimum 50%. Sealant is high grade Polymer sealant approved for use in potable water. sealed at the edges to provide proofing against vermin. Internally the tank will be complete with galvanised bracing rods and cleats to size as directed by our engineer. (to suit dimensions/height of the tank). All walls will be erected in straight lines. All vertical edges will be true to vertical and braced. Horizontal and vertical seams subject to minimum tolerances as approved by Tank Industries Engineers. All ladders and plumbing fittings will comply to all relevant codes, including AS1657 for fixed platforms and ladders, and AS3500 for plumbing items. The roof sheeting is Lysaght/Dualclad Zincalume or similar approved and

6 High quality stainless steel tanks for the fire, plumbing and other industrial markets. RP-SS SERIES STAINLESS STEEL RECTANGULAR PANEL TANKS Tank Industries manufacture high quality stainless steel tanks for the fire, plumbing and other industrial markets. Because the RP-SS series stainless steel rectangular panel tanks have many applications and uses, they are designed to meet the specific requirements of each customer s unique situation. As with all products in the Tank Industries range, Australian Standards are applied throughout the manufacturing and construction process, including the sealant which is a high grade Polymer approved for use in potable water applications. Sealing gaskets are high density PVC 6mm thick and compressible to a minimum of 50%. The versatility of RP-SS tanks allows for tailored size and dimensions that are specifically designed to fit into every problematical application. In addition the RP-SS tanks can be manufactured for hard-to-access sites or to replace existing tanks in constricted locations. Construction of the tank panels feature external bolting with M10 high tensile nuts and bolts, plus internally bolted design options are available when required. Internal construction of the tank will include stainless steel bracing rods and cleats sized to our engineers specifications appropriate to the height to width dimensions of the tank. High density foam or rubber seals, complete with backing plate, are used for corner and floor to wall joints. Minimum tolerances as approved by Tank Industries engineers will be applied to both horizontal and vertical seams. Lysaght/Dualclad Zincalume sheeting (or similar approved product) is used in the roof construction which is sealed at the edges to prevent vermin access. All fixed platforms and ladders are designed to AS1657, and all plumbing will comply with AS3500.

7 ADDITIONAL SERVICES AVAILABLE Tank repairs Liner replacements Foundation works Special applications Powder coating Pump sheds SPECIFIC TANK FEATURES Internal & external ladders Rolled cages & intermediate platforms Ball float level indicators Bottom panel access hatch Harness attachment for safe roof access Roof edge flashing for vermin proof protection Handrail systems Full range of connections available Modular tank options AUSTRALIAN STANDARDS COMPLIANCE AS4100 & AS4600 - Steel Structure Codes AS1397 - Sheet Galvanising AS4680 - Hot Dip Galvanising AS1657 - Fixed Paltforms & Walkways AS1170 - Wind Loadings AS4020 - Potable Products

For further information please contact us as per the numbers listed below. HUNT ENGINEERING & STAFF PTY. LTD. Tank Industries Division Melbourne Office 8 Redwood Drive, Dingley Victoria 3172, Australia Telephone (03) 9551 8188 Facsimile (03) 9551 2120 Sydney Office 7/10 Foundry Road, Seven Hills N.S.W. 2147, Australia Telephone: (02) 9674 1255 Facsimile: (02) 9674 1877 Email Web Site info@tankindustries.com.au www.tankindustries.com.au