Storage of Idle Combustible Pallets

Similar documents
Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

NFPA FAQs. 3. Can plastic pipe be used on a sprinkler system complying with NFPA 13?

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Stored Palletized, Solid Piled, Bin Boxes, or Shelf Storage (12.2)

Technical Article. Sprinkler Protection for High Bay and Automated Storage in Warehouse-Type Storage Facilities

Flammable and Combustible Liquid

Warehouse Checklist. Warehouse Construction

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Extended Coverage Sprinklers

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Fire-Rated Glass and Glazing START

Working Towards Protection Guidance for Warehouse Storage Li-ion Batteries

Building Code Clarifications - 7. Fire Resistance

Wood use in Type I and II (noncombustible) construction

Insight. Storage Fires. Balanced Risk Engineering Solutions. Understanding the Risk. Commodity Classification. Storage Configuration

Fire Protection Requirements of Empty Intermediate Bulk Containers (IBCs)

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

GYPSUM AREA SEPARATION FIREWALLS GA

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Electrical Classification

A TEST TO DETERMINE THE VIABILITY OF SELF-HEATING BEVERAGE CONTAINERS AS IGNITION SOURCES

Risk Guidance Note 03. Management of In-Rack Automatic Sprinklers (IRAS)

Excerpts from the Canadian National Building Code (NBC)

BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.

Sample Slip, Trip and Fall Prevention Program

Fire Life Safety ORC Review Guidelines for PPD Experimental Installations

Sample Return-to-Work Program

EcoTouch Insulation with PureFiber Technology

Flammable Liquids Storage

Flammable Liquids Storage

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Name Of Occupancy Date. Yes No Describe

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Approval Standard for Plastic Suspended Ceiling Panels

Flammable Liquids 29 CFR

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

HOT WORK PERMIT PROCEDURES

WHITE PAPER Fire & safety performance standards

Tire Safety for Passenger Vehicles and Light Trucks

FireLock LP-46 Storage Sprinkler V4601 Pendent FM Approved, culus Listed See Submittal Publication 40.95

Fiberglas, Exterior Wall Thermal Insulation

ATTACHMENT 12 CONTAINERS

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Inert Gas Extinguishing System Two Minute Discharge Study. Gene Hill, P.E. Brad Stilwell

Cargo Theft Prevention and Risk Mitigation for the Holiday Season

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Composite Panel Firewall Systems

EFSN Training i Module Minutes

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

FIRE SPRINKLER SYSTEM DESIGN, ENGINEERING EXEMPTION POLICY FOR (Effective April 1, 2006)

Guide Specifications for Maple Flooring Systems

DUPONT PERFORMANCE POLYMERS Joint Design: A Critical Factor in Strong Bonds GENERAL GUIDELINES FOR ULTRASONIC, VIBRATION AND SPIN WELDING

Development of Seismic-induced Fire Risk Assessment Method for a Building

Herringbone Pattern Flooring

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Construction Warehouse. Culminating Experience in Fire Protection Engineering FPE 596 Prepared by Ben Johnson

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Fire-Retardant-Treated (FRT) Plywood

SUPERIOR FIRE RESISTANCE

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

Budget Basins Modular Spill Platform Spill Containment Pallets Spill Containment Platforms

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

HOT WORK PERMIT PROGRAM TRAINING. John Braun

INNOVATIVE PLASTICS ULTRASONIC WELDING

MOTOR FUEL DISPENSING SAFETY

Requirements for Hydrogen Storage and Use

HEAVY DUTY STORAGE GAS

Certification: Building Plans Examiner. Exam ID: B3

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Errata NFPA 1. Fire Code Edition

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

GigaCrete Specification PlasterMax

High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications

Charter Township of Shelby Harry Reese Building Director

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

I.CHEM.E. SYMPOSIUM SERIES NO. 97

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

Understanding BS EN 771-3: Aggregate concrete masonry units

ADMINISTRATIVE SERVICES MANUAL

Property Policyholder Risk Improvement Report and Hurricane Survey

Landscaping with Ornamental Trees and Exterior Structure Features Using EcoSmart Fire Model

version 1.0 Made by NARVI Oy Finland Kota Kuru 14 and 20 sauna heaters Installation, user and maintenance instructions

Safe Operating Procedure

GreenGuard Housewrap Installation Guide

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Flame Spread Performance of Wood Products

IBC Tote Containment Sumps

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Transcription:

Hanover Risk Solutions Storage of Idle Combustible Pallets The storage of idle combustible pallets presents a significant fire hazard, both in indoor and outdoor storage. A fire involving even a modest number of idle pallets inside a building can rapidly overtax a fire sprinkler system. This report outlines the fire hazards and control measures associated with the storage of idle pallets, with a primary focus on wood pallets. Although most often associated with warehouses, pallets can be found in nearly every industrial and commercial facility. Wherever pallets are used, the potential exists for the accumulation of excess or idle pallets that are awaiting use. While, initially, these accumulations may be thought to be temporary, the number of idle pallets can increase over time. To better utilize space, idle pallets are typically stacked in piles. A pallet pile is generally cube-shaped and about 4 ft. (1.2 m) high. A fire involving even a modest number of idle pallets inside a building can rapidly overtax a fire sprinkler system. Careful control and management of idle pallets is required to prevent accumulations from becoming a significant fire exposure. This report outlines the fire hazards and control measures associated with the storage of idle pallets, with a primary focus on wood pallets. Pallet Types Pallet design is not universal. Various countries and industries have their own design standards for pallets. In North America the most common pallet size is 48 in. x 40 in. (1.2 m x 1.0 m). For fire protection purposes, NFPA 13, Standard for the Installation of Sprinkler Systems, published by the National Fire Protection Association (NFPA), differentiates between wood and plastic pallets. Wood pallets are probably the most common type encountered, but the use of plastic pallets is increasing. Pallets may also be made from metal, cardboard, or recycled paper; however, it is rare to find these types. Metal pallets (i.e., skids) are not considered a fire hazard due to their non-combustible makeup. Wood Pallets Wood pallets are typically constructed from various types of hardwoods (e.g., oak, yellow poplar, and alder) and softwoods (e.g., pine). Pallets may have slatted or solid tops and bottoms or a combination. While wood pallet designs vary from manufacturer to manufacturer, the basic structure remains consistent. A wood pallet will have three primary supports that are parallel to each other (i.e., two sides and a mid support). The actual dimensions of these supports will vary, but are roughly 2 in. (5 cm) wide and 4-in. (10.1 cm) high. Thin wood slats are then nailed or stapled, at right angles, to the tops and bottoms of these supports. continued

HANOVER RISK SOLUTIONS The slats will be run from one side support across the center support and terminate at the other side support. A space is maintained between each slat to reduce overall weight. In some cases, plywood may be placed across the tops of the supports when a solid-surface pallet is required. Plastic Pallets Pallets may be manufactured from various types of plastic. One of the more common types of plastic pallet is the non-expanded, high-density polyethylene (HDPE) solid-deck pallet. Plastic pallets are typically injectionmolded, one-piece designs. Similar in overall appearance to wood pallets, plastic pallets are more resistant to weather, oil, and chemical attack, and damage from rough handing. Cardboard Pallets Wood fiber, cardboard, and recycled paper pallets are manufactured using a molding process. Typically, these pallets are used in environments that are not subject to dampness or temperature changes. For fire protection purposes, these pallets are treated in the same manner as wood pallets. Fire Hazard The fire hazard of idle pallet storage is a function of the type of pallet material, pallet geometry, and the storage arrangement. The intense heat generated from a pallet fire can cause the structural steel of a building to quickly fail. Further, the fire and smoke generated, and water usage for firefighting, will be significant, which can create an exposure for neighboring occupancies. Pallet Material The conventional pallet is typically made from wood. As wood loses its moisture content, it becomes easier to ignite. In addition, as wood pallets dry out, their edges tend to become frayed and splintered. In this condition, a small ignition source can easily ignite them. Plastic pallets burn as hot as wood and for a longer time. When burning, plastic pallets may melt, drip, and form pools of liquid plastic on floors. Burning pools of plastic can flow and spread fire to other areas of a facility. The combustion of plastic may produce large quantities of smoke. Pallet Geometry The geometry of a pallet also contributes to burning conditions. When pallets are stood on edge, they create a vertical flue space that allows for rapid burning. A vertical configuration provides the greatest amount of surface area for combustion. A fire occurring at the base of a pallet will spread upward as the rising gases preheat the thin slats above it. This preheating and high airflow leads to a rapid fire spread throughout the pallet pile. Flat stacking of pallets provides less surface area for combustion. When one pallet is placed on the next, the thin slats typically cover each other, limiting the available surface area. However, the open area between slats provides a large vertical flue space for fire spread. Arranging flat-stacked pallets at right angles to each other will limit the flue space in the pallet pile, but does not afford easy handing of the pallets. Of the two configurations, flat stacking is the most effective approach to idle pallet storage from both a fire protection and materials handling standpoint. Storage Arrangement Floor stacking of idle pallets in pile groups of four stacks will provide easy access to material handling equipment and limit the amount of airflow through the pile. Many facilities opt to store idle pallets in racks to reduce clutter. While this storage arrangement may provide for better materials handling, it does present a significant fire risk. Pallets stored in racks have unrestricted airflow that will rapidly accelerate a fire. While the likelihood of a fire igniting in rack-stored pallets is less than that of floor storage, the flame propagation will be much faster. Further, the high heat produced by 2

HANOVER RISK SOLUTIONS burning pallets may lead to a failure of the rack assembly as the metal becomes fatigued. Outside storage of idle pallets is the preferred method from a fire protection standpoint. By locating pallets outside, away from buildings and other exposures, property loss from a pallet fire will be restricted to the pallets. Outside storage of idle pallets does present several concerns, including premature aging of the pallet material and environmental damage if pallets have been exposed to hazardous materials. Additionally, the outside storage of wood pallets makes them susceptible to theft and arson-related fires. Hazard Control Since accumulation of idle pallets can occur in any occupancy, it is important to monitor the number of pallets and storage arrangement on an ongoing basis. Generally, it is advisable to store pallets outdoors, in a separate building(s) intended for such storage. Outside Storage Section 34.10 of NFPA 1, Uniform Fire Code, provides general requirements for the outside storage of idle pallets. These requirements include: Pallet piles should be separated from other storage by at least 20 ft. (6 m) for piles of less than 50 pallets; 30 ft. (9 m) for piles of 50 200 pallets; and 50 ft. (15 m) for piles of greater than 200 pallets. Pallet piles should not exceed 15 ft. (4.6 m) in height and should not exceed 400 ft. 2 (37 m 2 ) in area. At least 8-ft. (2.4-m) clearance should be maintained between pallet piles and adjacent property lines. Additionally, a pallet pile should be separated from buildings by clear spaces to prevent the spread of fire from the pile to a structure. Section 34.10 of NFPA 1 also provides minimum separations of pallet piles from buildings, as follows: Piles of 200 or less pallets may be stored with no minimum separation from buildings with masonry walls having no openings. However, experts recommend a minimum separation of at least 10 ft. (3.1 m). Piles of 200 or more pallets may be stored with a 15-ft. (4.6-m) separation from buildings with masonry walls having no openings. Piles of 50 or less pallets should have at least a 20-ft. (6.1-m) separation from buildings with wood frame or similar walls (e.g., iron-clad metal). This clearance should be increased to 30 ft. (9.1 m) for 50 to 200 pallets and 50 ft. (15.2 m) for storage of more than 200 pallets. These distances may be reduced when outside sprinklers are provided. Table 34.10.3(b) of NFPA 1 provides a number of other separation requirements based on wall construction and the types of wall openings present. Additionally, Factory Mutual (FM) Property Loss Prevention Data Sheet 8-24 Idle Pallet Storage provide slightly different separation distances, often more restrictive, than NFPA 1. For example, pallet piles exceeding 200 pallets could have a separation distance that varies from 3 feet to 90 feet (1 m to 27 m), depending on building construction. Inside Storage The intense heat generated by a fire in an idle pallet storage area could quickly weaken structural steel and lead to the collapse of a building. Steel columns that are surrounded by storage may be vulnerable depending on the amount of storage and fire protection available. Likewise, overhead steel framework will be exposed to the heat in a fire plume. Section 12.12 of NFPA 13 provides requirements for the sprinkler protection of idle pallets based on the pallet material (i.e., wood or plastic) and the storage arrangement. Wood Pallets NFPA 13 currently requires the indoor storage of idle wood pallets be protected by automatic sprinkler systems. This represents a change from earlier revisions (e.g., 2002 and earlier) of the standard. The current standard 3

SEGMENT HANOVER BAND RISK SOLUTIONS requires that the indoor storage of wood pallets be protected using one of the following: Control mode density/area sprinkler protection as specified in Table 12.12.1.2(a), which limits storage to 20 ft. (6.1 m) in height. Control Mode Specific Application (CMSA) Sprinkler protection in accordance with Table 12.12.1.2(b), which limits storage to 20 ft. (6.1 m) in height. Early Suppression Fast-Response (ESFR) Sprinkler protection in accordance with Table 12.12.1.2(c), which limits storage for a pendent head orientation to 35 ft. (10.7 m) in height and 20 ft. (6.1 m) for upright head orientation. The section also provides protection requirements for pallets that are stored no higher than 6 ft. (1.8 m) in height, with stacks (of four pallet groups) separated by at least 8 ft. (1.4 m) and having a clear space of 25 ft. (7.6 m). This arrangement previously (prior to the 2007 edition) did not require sprinkler protection. The 2007 and later revisions of NFPA 13 require that such an arrangement be protected in accordance with the OH2 density curve of Figure 13.2.1, Miscellaneous Storage 12 ft. (3.7 m) or Less in Height Design Curves. Plastic Pallets Section 12.12.2 of NFPA 13 limits the indoor storage of idle plastic pallets to floor storage not exceeding 10 ft. (3 m) in height when the pallets are protected by an automatic sprinkler system with a sprinkler density of at least 0.6 gpm/ft. 2 (24.5 mm/min) over 2,000 ft.2 (186 m 2 ), and a K factor of at least 16.8. Additional allowances include: Storage of plastic pallets outside of cutoff rooms is limited to 4 ft. (1.2 m) in height and stacks (of two pallet groups) separated by at least 8 ft. (1.4 m) and protected by sprinklers using an OH2 design and having a high temperature rating. The in-rack storage of plastic pallets is allowed when the racks are protected by an ESFR sprinkler system meeting the design requirements of Table 12.12.2.2.3. Summary An accumulation of idle pallets presents such a significant fire risk to a facility that it should be closely monitored. Idle pallet storage should be limited to the minimum needed to meet production demands and without exceeding the storage requirements outlined by NFPA. Storage of idle pallets in an outside, secured location, where sufficient clearances from exposures are maintained, is the most effective method of loss control. Additionally, outside pallet storage should be located away from any air intakes, ducts, or building openings that could allow smoke from burning pallets to enter the building. Pallets should not be stored next to walkways, driveways, or similar locations that may expose people or property in the event of a fire. The National Wooden Pallet & Container Association provides a number of useful references for pallet users on their website at http://www.nwpca.com. Plastic pallets can be stored up to 12 ft. (3.7 m) high in cutoff rooms when the room is protected by three-hour fire-rated walls and a sprinkler system with a density of at least 0.6 gpm/ft. 2 (24.5 mm/min) or a ESFR system with a K factor of 14. In addition, all steel columns are required to be protected by a one-hour fire rated covering or protected by a sidewall sprinkler. 4

SEGMENT HANOVER BAND RISK SOLUTIONS References 1. Factory Mutual Engineering Corp. Idle Pallet Storage. Property Loss Prevention Data Sheet 8-24. Norwood, MA: FM Global, 2015. 2. National Fire Protection Association (NFPA). Fire Protection Handbook. 20th ed. Quincy, MA: NFPA, 2008. 3.. Standard for the Installation of Sprinkler Systems. NFPA 13. Quincy, MA: NFPA, 2013. 4.. Uniform Fire Code. NFPA 1. Quincy, MA: NFPA, 2015. s c To learn more about Hanover Risk Solutions, visit hanoverrisksolutions.com The Hanover Insurance Company 440 Lincoln Street, Worcester, MA 01653 hanover.com The Agency Place (TAP) https://tap.hanover.com Copyright 2015, ISO Services, Inc. The recommendation(s), advice and contents of this material are provided for informational purposes only and do not purport to address every possible legal obligation, hazard, code violation, loss potential or exception to good practice. The Hanover Insurance Company and its affiliates and subsidiaries ( The Hanover ) specifically disclaim any warranty or representation that acceptance of any recommendations or advice contained herein will make any premises, property or operation safe or in compliance with any law or regulation. Under no circumstances should this material or your acceptance of any recommendations or advice contained herein be construed as establishing the existence or availability of any insurance coverage with The Hanover. By providing this information to you, The Hanover does not assume (and specifically disclaims) any duty, undertaking or responsibility to you. The decision to accept or implement any recommendation(s) or advice contained in this material must be made by you. 171-1740 (1/16) LC 2015-352