BtmGlobal System. Controller. User Manual

Similar documents
Temperature & Humidity SMS Alert Controller

SNMP Web Management. User s Manual For SNMP Web Card/Box

NC-12 Modbus Application

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Float Current Monitor FS3. User Manual

Executive Summary. Technical Description

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Job Aid Pre-Installation Information S8500 Media Server

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

IP DSLAM IDL Quick Installation Guide

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Adit 3000 Series Part Guide

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Uninterruptible Power Supply

User Manual. EtherUSB

TrueAlarm Fire Alarm Systems

MCR1900 Media Converter 19-Slot Chassis

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

QUICK INSTALLATION GUIDE

Remote Serial over IP Introduction on serial connections via IP/Ethernet

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Application/Connection Examples

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

IP POWER 9258 USER MANUAL IP POWER 9258 USER MANUAL

Emerson Smart Firewall

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Connecting the DG-102S VoIP Gateway to your network

PN5212/PN5320/PN7212/PN7320

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Square D Model 6 Motor Control Centers

NETWORK ENABLED EQUIPMENT MONITOR

InnoMedia ESBC B. Quick Install Guide. 1

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

HWg-STE HWg-STE PoE MANUAL

NGSS Data Consolidator (DC)

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

PT Mbps Powerline Adapter. User Guide

Wireless Router Setup Manual

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

PCS0100en Persy Control Services B.V. Netherlands

TD-8610/TD-8610B External ADSL2+ MODEM

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

Quick Start Guide. RV0xx Series Routers

EMBEDDED ACCESS CONTROL Hardware Installation Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Modbus and ION Technology

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Energy Communication Unit (ECU)

F2400 FOM II Series Fiber Optic Modem Technical Manual

TX2123 RS485 TO ETHERNET ADAPTOR

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

Internet Telephony PBX system IPX-1980

200 Range Dialer Installation Manual. Version 1.0

Power Commander Power Distribution Units from Wiremold/Legrand offer

User Manual. EtherUSB

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

User Manual Revision English

Introduction Media converters

PowerCommand iwatch 100

JT Fibre is here What to expect as a new JT Fibre customer

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

Quick Design & Install Guide. Computerised Emergency Evacuation System LONWORKS TM Powerline Technology

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

Temperature Alert. LAN-based Temperature and Humidity Data Logger

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Modular I/O System Analog and Digital Interface Modules

Provides one channel for Ethernet over existing

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

HC Products ILF-100WD User Manual

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Table of Contents. TransformerIQ FAQs 1

FT-1000/GPS-N. System of remote monitoring and control of physical

PE6108/PE6208/PE8108/PE8208

Energy Communication Unit (ECU)

IP SENSOR 9216 USER MANUAL IP SENSOR 9216 USER MANUAL

DCS Data and communication server

Duct Humidity Transmitter

InnoMedia ESBC B. Quick Install Guide. 1

FAQ s on Siemens Magmeters

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Using installed Fieldbus Wiring to carry Ethernet Communications

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

NetScanner System. Toronto: , Montreal: , Toll Free: ,

2-Pair HDSL1 Adtran Fiber Optic Link System

Transcription:

BtmGlobal System Controller User Manual Version 4.0.3 Polytronics Engineering Ltd. 2010 All Rights Reserved 1

Table of Contents Introduction... 3 Site Requirements... 3 Hardware Overview... 4 Hardware Installation... 5 Installation... 6 Communication Path Installation... 6 Terminating Fiber Optic Cables... 6 Hardware Verification and Configuration... 7 System Setup and Operation... 8 Accessing Battery Data... 8 Summary Page... 9 Appendix A: Local Data Access... 10 Connecting Using a Router (Dynamic Addressed Controller)... 10 Appendix B: Controller Alarms and String Status... 11 Appendix C: Sample Controller System... 13 Appendix D: Mechanical System Layouts... 14 2

Introduction The controller is a real-time, stand-alone battery monitor with full networking support. It is used for storing individual cells/jars and full string data, detecting abnormalities coming from the battery measurements, warning about the changes in the battery condition and alarming when critical conditions occur on an individual Jar(s) or the entire string. Based on the collected data, the controller generates various comprehensive reports for assessing the operational conditions and the health of the battery. The generated reports are presented in Hyper Text Markup Language (HTML) and in Portable Network Graphics formats (various graphs and plots) to utilize the Internet based World Wide Web browsers. Currently, only Mozilla Firefox fully supports all the user interface features. The controller s network support facilitates TCP/IP protocol over Ethernet. The system is easily accessible (locally or remotely) over Modem for report viewing, data downloading, configuration and system upgrading. The system can also be configured to automatically upload the report-pages to a predefined Web Site and use Email for the remote enunciation of alarms (local ISP access point or local network Gateway access is required). The System Controller supports the following services over TCP/IP network: HTTP: serves battery report pages for WEB-browser FTP: file transfer service SSH: secure shell for remote system configuration/upgrade Mail: electronic mail agent (configured to send alarm messages) Site Requirements Ethernet access (optional) Direct telephone line (optional if remote access/support is required) Uninterruptible power supply 500VA or UPS protected AC outlet 3

Hardware Overview The concentrators are configured either as low voltage or high voltage devices. The high voltage concentrators can serve up to 20 Jars, and the low voltage concentrator can serve up to 30 Jars. There are a few small differences in the equipment depending on whether the system is monitoring 2V or 12V Jars. Although concentrators may look the same, it is important to check the nameplate to tell whether the concentrator has the proper voltage for your application. All concentrators are powered from the battery monitored. However, the controller uses a 120/220 VAC outlet for power. Note: In order to maintain data acquisition during a power failure, the AC outlet must be UPS protected or have an emergency generator as a backup. 4

Hardware Installation Alarm contacts, may be connected to light/bell if desired) AL WD IN OUT Fiber Optical Cable Float Current Montior Concentrator Charger Negative Jar #32 Jar #17 Concentrator Jar #16 Jar #1 Charger Positive Battery String #1 Float Current Montior Concentrator Charger Negative Jar #32 Jar #17 Concentrator Jar #16 Jar #1 Charger Positive Battery String #4 Figure 1: System Connectivity 5

Installation Communication Path Installation Layout the devices and measure the distances between the connection points for the communication loop. The devices are connected in a daisy chain format - from the fiber optics output (blue) of one device and then connected to the fiber optics input (black) of the next. Plan your connections of fiber optical cable to minimize the length of the longest fiber optical cable run. If multiple strings are connected to the single optical loop, then fiberoptical cable must connect across strings (sometimes in another battery room). Take care to keep the radius on all bends at least 2 inches or 40 mm. Care should be taken to run all lengths prior to cutting. Warning: The fiber optical loop must be planned very carefully before cutting the fiber optic cable because there is no way to join cut pieces of fiber optic cable together without any extra equipment. Also, neither the sequence nor the total length of the cable is important. The only important aspect is the length of the longest piece of the cable is. The longest fiber optic cable must not exceed 60 meters. Terminating Fiber Optic Cables The fiber optic cable from the concentrators should be terminated in the appropriate socket in the controller. Prepare the end of the fiber optic cable by cutting it at a right angle with a sharp utility knife. Do not strip the fiber-optic wire. With limited force, a stripped wire can damage the internal receiver and transmitter. Position the prepared end of the fiber optic cable in the input (or output) of the special fiber optic s connector, be sure the connector is loosened. Push the end of fiber optics cable into the housing; tighten the connector with finger force as much as would be used to close a toothpaste container. 6

Hardware Verification and Configuration Workstations on IP network PSTN line Remote Workstation Windows Hyperterminal SW Dial-in / Remote data access / remote configuration Internet Explorer HTML Report Pages Data access system configuration BTM-Global Stand-alone system 120/220 Vac (1 A Max) protected power source LAN / WAN PWR COM1 KM LAN1 CRT Modem Ethernet access-point Ethernet Cable Internet explorer - HTML Report Pages On Site Mobile PC / Laptop Data access system configuration Figure 2: Connecting PC to the Controller 7

System Setup and Operation The controller you have received has been pre-configured for your installation. Reconfiguration of the controller box can be performed remotely over the telephone-line (dial in), Ethernet or locally. Further instructions on configuring and use of the system are incorporated into the monitoring controller web page. Accessing Battery Data The controller system facilitates several means to access data. All necessary battery data is stored in the controller and is also presented in an HTML formatted report file. Any graphics are produced in the PNG (Portable Network graphics) format. Complete access to all data (including raw data) can be achieved by establishing a dial-in network connection, or by connecting the System Controller to a local Ethernet network. The System Controller has a built-in web-server capability and, all HTML report pages can be browsed using a local network connection or over a dial-in network. Raw data, ASCII text tables and other relevant files, can be retrieved using an FTP site. Note: The System Controller is configured for dynamic IP address and should work with any existing network. 8

Summary Page Figure 3: Controller Summary Page The Summary page summarizes data and provides links to all the other areas of the system. It displays information about the batteries themselves: the status, alarms, charge level, voltages, current, ripple current, ambient and pilot temperatures of the string are displayed. Clicking on the logo in the top right side opens up a FAQ for the controller. 9

Appendix A: Local Data Access Connecting Using a Router (Dynamic Addressed Controller) 1. Connect the PC, router and Controller(s) as shown in Figure 4. To Other Equipment Local PC Ethernet Cable Ethernet Cable Ethernet Cable Ethernet Cable Figure 4: Connection of Controller, Router and PC 2. Start your web browser (Mozilla Firefox and in the address bar type btmglobalxx, where XX is digits 01 99. The Controller name is recorded on the front label. 10

Appendix B: Controller Alarms and String Status Alarm Bit Position Description String Exhausted 1 Battery total voltage is below discharge end voltage (during discharge) String Open 2 String is at open potential, charger not connected or malfunctioning Pending Jar Reversal 3 A jar terminal voltage is near its end voltage during discharge. This jar does not support the load any longer. Low Capacity 5 String capacity near exhaustion, a few minutes reserve time remaining Jar Internal resistance High 6 The internal resistance of a jar has increased drastically. Jar Voltage Below set limit 7 During float operation, the jar terminal voltage is below preset limit. Jar voltage Above set limit 8 During float operation, the jar terminal voltage is above preset limit. Jar High Float Mobility 10 Jar terminal voltage drifts significantly during battery floating Jar High Noise during Float 9 High ripple voltage during float operation Temperature Abnormalities 12 Ambient/Pilot temperature outside limits Discharge Warning 13 String is discharging Charge Warning 15 String is charging Equalization Warning 14 String is at Equalization potential Jar Parameters Degraded 16 Jar calculated parameters during discharge, charge or Float have been degrading. Ground Fault 17 When using a ground fault detector, the limit at which it alarms has been passed and ground fault condition is present. Note: Each alarm can be individually enabled or disabled. The controller can send an e-mail when an alarm is detected if it is connected to the LAN or has a dial-out to the ISP capabilities enabled. String Status NA OPEN FLOATING FLOAT-CHARGING Description String status unknown. During a system start-up or communication failure String is at open potential String is fully charged and floating at its nominal voltage Battery capacity is not fully restored. 11

CHARGING EQUALIZING DISCHARGING Charging current to the battery detected. Battery at equalizing potential (prolonged application will be harmful to the battery). Load is on the battery. 12

Appendix C: Sample Controller System Remote Workstation Windows Hyperterminal SW Local Workstations Internet Explorer HTML Report Pages PSTN line Dial-in / Remote data access / remote configuration 120/220 Vac (1 A Max) protected power source PSTN Interface: external modem (optional) COM1 KM LAN1 CRT PWR Ethernet interface (RJ-45 for 10/100Mbs): TCP/IP protocol: - HTML server - FTP server LAN Rs232 cable Ethernet access-point Cross-over network cable Internet explorer - HTML Report Pages On Site Workstation Out BTM4000I Concentrator ID #3 In T Sensor Charger Negative Jar #32 Jar #17 BTM4000I Concentrator ID #1 Jar #16 Battery String #4 Figure 5: Sample System Setup Jar #1 Charger Positive Current Shunt (not required if current is less than 400A and Factstar option is selected) 13

Appendix D: Mechanical System Layouts WALL MOUNTED CONCENTRATOR 7.52 (191) 1.65 (42) 0.39 (10) 0.63 (16) TOP VIEW 11.65 (296) 0.24 (6) BTM CONCENTRATOR 0.39 (10) 0.24 (6) 4.88 (124) FACTSTAR CURRENT TRANDUCER 2.17 (55) TOP VIEW 7.4 (188) 3.94 (100) 1.77 (45) BTM GLOBAL CONSOLE 2.32 (59) PLASTIC FIBRE OPTICS ALARM CONTACTS TOP VIEW 4.61 (117.1) 0.24 (6) 0.197 (5) 0.31 (8) 1.34 (34) 3.58 (91) 18 CONNECTOR TERMINAL BLOCK 3.19 (81) 16 CONNECTOR TERMINAL BLOCK 2.48 (63) 0.39 (10) TEMPERATURE SENSOR 3.35 (85) 3.54 (90) 0.24 (6) 9.84 (250) 2.05 (52) 0.197 (5) CT ALL DIMENSIONS ARE IMPERIAL (MILLIMETERS ARE IN BRACKETS) Figure 6: Mechanical Layout BTM GLOBAL COMPONENTS MECHANICAL LAYOUT NOV 20,2006 Rev. A SCALE 1:4 1 OF 2 14

SIDE VIEW SIDE VIEW 1.42 (36) SIDE VIEW 1.25 (31.75) 0.25 (6.35) FRONT VIEW FLOAT CURRENT TRANSDUCER FRONT VIEW B- 28 26 24 22 20 18 16 14 12 10 8 6 4 2 B1+ B+ 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 BC HC CONCENTRATOR FRONT VIEW SYSTEM CONTROLLER UNDER BATTERY RACK MOUNTED COMPONENTS ALL DIMENSIONS ARE IMPERIAL (MILLIMETERS) BTM GLOBAL COMPONENTS MECHANICAL LAYOUT NOV 20,2006 Rev. A SCALE 1:4 2 OF 2 Figure 7: Mechanical Layout 15

FIBER OPTICS OUT TO BTM CONCENTRATOR FIBER OPTICS IN FROM BTMGLOBAL CONSOLE FLOAT CURRENT TRANSDUCER TEMPERATURE SENSOR LEAD TEMPERATURE SENSOR 12V DC, 2A MAX POWER SUPPLY (SWITCHING) DC-DC POWER CONVERTER OPTION, OUTPUT: 12V DC, 2A MIN TEMPERATURE SENSOR LEAD BtmGlobal CURRENT TRANSFORMER BLACK LEAD CURRENT TRANSFORMER RED LEAD SYSTEM CONTROLLER +12V FROM SYSTEM CONTROLLER SECOND COM PORT TO MODBUS INTERFACE POWER GND FROM SYSTEM CONTROLLER CT VGA INTERFACE (OPTIONAL MONITOR) ALL HOOK-UP WIRES: TINNED COPPER, PVC INSULATED, STRANDED, AWG 18, 600V,105C (BELDEN STYLE 1015 OR EQUIVALENT) OR TINNED COPPER, POLYOLEFIN (XLPE) INSULATED, STRANDED, AWG 18, UL AWM STYLE 3265 105 C, 600V. SUPPLIED BY INSTALLER. WIRE LENGTH BETWEEN CONCENTRATOR TERMINAL AND BATTERY POST SHOULD NOT EXCEED 100FT (30M). ETHERNET INTERFACE KBD/MOUSE INTERFACE PLASTIC FIBER OPTICAL CABLE (SMF) SUPPLIED WITH THE SYSTEM. LONGEST FIBER OPTICAL SEGMENT MUST NOT EXCEED 100FT (30M). TO MODBUS INTERFACE 2 OR 4 WIRE RS485 RS485 CONVERTER NOT SUPPLIED WITH THE SYSTEM RECOMMENDED MODEL: 485OT9L B&B ELECTRONICS +12V FROM SYSTEM CONTROLLER POWER GND FROM SYSTEM CONTROLLER BATTERY: 24VDC 48VDC 96VDC 120VDC 240VDC TO AC OUTLET: 100-240 VAC 50/60 HZ FIBER OPTICS OUT TO FLOAT CURRENT TRANSDUCER FIBER OPTICS IN FROM BTM CONCENTRATOR INTERNAL COM FAILED ALARM CONTACT BATTERY ALARM CONTACT +12V TO FLOAT CURRENT TRANSDUCER (OPTIONALLY TO RS485 CONVERTER) POWER GND TO FLOAT CURRENT TRANSDUCER (OPTIONALLY TO RS485 CONVERTER) Figure 8: Mechanical Layout ALARM RELAY CONTACT RATING: SWITCHING POWER: 10W SWITCHING VOLTAGE: 100VDC SWITCHING CURRENT: 500 ma BTMGLOBAL COMPONENT CONNECTIONS: SYSTEM CONTROLLER AND FLOAT CURRENT TRANSDUCER NOT TO SCALE JAN 10,2007 Rev. B 1 OF 1 16