Elemental analysis of PM2.5 with energy dispersive X-ray fluorescence spectrometer NEX CG

Similar documents
X-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING

EDXRF of Used Automotive Catalytic Converters

Coating Thickness and Composition Analysis by Micro-EDXRF

Introduction to Elemental Analysis by ED-XRF Justin Masone Product Specialist 3 June 2015

Portable X-ray fluorescence Spectroscopy. Michael A. Wilson Research Soil Scientist USDA-NRCS National Soil Survey Center Lincoln, NE

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

OLIVÉR BÁNHIDI 1. Introduction

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

Quantitative Analysis Software for X-Ray Fluorescence. XRF-FP is a full-featured quantitative analysis package for XRF

h e l p s y o u C O N T R O L

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

Lectures about XRF (X-Ray Fluorescence)

ANALYSIS OF LEAD IN CANDLE PARTICULATE EMISSIONS BY XRF USING UNIQUANT 4

Sample preparation for X-ray fluorescence analysis

X Ray Flourescence (XRF)

Gold Refining and Coin Manufacturing at the Royal Canadian Mint

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Field portable XRF analysis of environmental samples

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

Advanced Physics Laboratory. XRF X-Ray Fluorescence: Energy-Dispersive analysis (EDXRF)

Quality Control on Aerospace Components Using Handheld X-ray Fluorescence (XRF)

3. What would you predict for the intensity and binding energy for the 3p orbital for that of sulfur?

RoHS Test Methods. Presented by: Bruce Peterson

Spectral distribution from end window X-ray tubes

XRF MAPPING: NEW TOOLS FOR DISTRIBUTION ANALYSIS

Universal Data Acquisition (UDA)

Standard Operating Procedure for EPA s LBL Energy Dispersive X-Ray Fluorescence Spectrometry

Instrumentation. (Figure 2)

The Limitations of Hand-held XRF Analyzers as a Quantitative Tool for Measuring Heavy Metal Pesticides on Art Objects. By Özge Gençay Üstün

Basic Concepts of X-ray X Fluorescence by Miguel Santiago, Scientific Instrumentation Specialist

Elemental Analyses by ICP-AES

Determination of Ultra Low Chlorine (and Sulfur) in Oil

Metals in Soil Analysis Using Field Portable X-ray Fluorescence

How To Use The Nexion 300

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Atomic Calculations. 2.1 Composition of the Atom. number of protons + number of neutrons = mass number

Concept differences in WD-XRF goniometer systems

Analytical Techniques for Trace Elemental Analyses on Wafer Surfaces for Monitoring and Controlling Contamination

Nanoparticle Deposition on Packaging Materials by the Liquid Flame Spray

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Regional Environmental Protection Agency- Veneto Region LABORATORY REGIONAL DEPARTMENT

M. Bouchard, S. Rivard, and C.O. Arsenault Corporation Scientifique Claisse, Quebec City, Canada S. Ness Intertek Genalysis, Perth, Australia

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

The NEW X-MET7000 Faster, lighter,

MODERN ATOMIC THEORY AND THE PERIODIC TABLE

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Pesticide Analysis by Mass Spectrometry

AUTOMATED MONITORING OF STACK GAS EMISSIONS BY EDXRF

Periodic Table, Valency and Formula

EXPERIMENT 4 The Periodic Table - Atoms and Elements

Standard Operation Procedure. Elemental Analysis of Solution samples with Inductively Coupled Plasma Mass Spectrometry

C-DEBI Research Coordination Network

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Energy Dispersive X-ray Fluorescence Spectrometer EDX-7000 EDX-8000 C142-E037A

Silicon Drift Detector Product Brochure Update 2013

An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry

2014 Spring CHEM101 Ch1-2 Review Worksheet Modified by Dr. Cheng-Yu Lai,

AMD Analysis & Technology AG

Quantification of Non-Fibrous and Fibrous Particulates in Human Lungs: Twenty Year Update on Pneumoconiosis Database

Electrons in Atoms & Periodic Table Chapter 13 & 14 Assignment & Problem Set

be Used to Identify Asphalt Binders?

THEORY OF XRF. Getting acquainted with the principles. Peter Brouwer

Chapter 2 Atoms, Ions, and the Periodic Table

Chapter 3 Mass Relationships in Chemical Reactions

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

13C NMR Spectroscopy

New Developments and Functional Enhancements in RDE Used Oil Analysis Spectrometers

SUS. Company Profile. Ulrich Nell, Feldstr.23, D Oberhausen, Tel. 0049(0)208/ Fax 0049(0)208/658536

47374_04_p25-32.qxd 2/9/07 7:50 AM Page Atoms and Elements

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

ANALYSIS OF PIGMENTS USED IN SCROLL PAINTINGS OF A NATIONAL TREASURE "TALE OF GENJI" USING A PORTABLE X-RAY FLUORESCENCE SPECTROMETER

SCH 3UI Unit 2 Outline Up to Quiz #1 Atomic Theory and the Periodic Table

Performance Assessment of EAGLE 5000 in Tobacco Smoke Environment. REPORT

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

IDENTIFICATION OF PAINTING MATERIALS USED FOR MURAL PAINTINGS BY IMAGE ANALYSIS AND XRF

SENSORS FOR AIR QUALITY MONITORING MARCEL ZEVENBERGEN SR. RESEARCHER GAS AND ION SENSORS

Analyses on copper samples from Micans

Amount of Substance.

Edited by. C'unter. and David S. Moore. Gauglitz. Handbook of Spectroscopy. Second, Enlarged Edition. Volume 4. WlLEY-VCH. VerlagCmbH & Co.

Adapter Catalog MOBILE METAL ANALYZER. SPECTRO isort and SPECTROTEST

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry

Analyzing Small Molecules by EI and GC-MS. July 2014

Atomic and Nuclear Physics Laboratory (Physics 4780)

Sample Analysis Design Isotope Dilution

Wipe Analysis to Determine Metal Contamination on Critical Surfaces

KEY for Unit 1 Your Chemical Toolbox: Scientific Concepts, Fundamentals of Typical Calculations, the Atom and Much More

Spectral Measurement Solutions for Industry and Research

From Lab to Field: Why Teaching XRF Matters

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Raman Spectroscopy Basics

3 - Atomic Absorption Spectroscopy

Glancing XRD and XRF for the Study of Texture Development in SmCo Based Films Sputtered Onto Silicon Substrates

Transcription:

Technical articles Elemental analysis of PM2.5 with energy dispersive X-ray fluorescence spectrometer NEX CG Atsushi Morikawa* 1. Introduction 1.1. Elemental analysis of PM2.5 Concerns about the effect of atmospheric aerosol particles have been increasing in recent years and its impact on global climate, air pollution and human health have been studied extensively. Recent reports of extremely high concentration levels of PM2.5 in China have drawn worldwide attention to this issue as well. PM2.5 are small particles suspended in the atmosphere with diameter less than 2.5 μm. The size is sufficiently small such that breathing can cause the particles to enter deep regions in the lungs where the air and blood are in intimate contact. This has raised concern not only about its effect on the respiratory but also on the cardiovascular system (1). Elemental analysis of atmospheric aerosols including PM2.5 is an important means that can provide information about its source and environmental impact. In Japan, for the analysis of inorganic elements of PM2.5, acid decomposition of the collected sample followed by inductively coupled plasma-mass spectrometry (ICP-MS) method has been recommended. However, the sample preparation of this analysis method is complicated and analysis error can vary depending on the operator. Furthermore, the sample can not be recovered after measurement since ICP-MS requires that the sample be dissolved in an acid solution. To overcome these issues, the Japanese ministry of environment established a Guideline for Component Analysis of PM2.5 in 2007 which is a simple and nondestructive analysis method of inorganic elements by X-ray fluorescence (XRF) analysis. The guideline was partially revised in 2013 which describes the analysis process of PM2.5 by XRF more concretely (2). 1.2. Elemental analysis of PM2.5 with XRF Inorganic components in atmospheric aerosols such as PM2.5 collected on filter can be analyzed easily and non-destructively by XRF. It is also effective when many samples have to be analyzed rapidly. In addition, it has the advantage of being able to easily measure the major component of soil silicon (Si), which is difficult to analyze by the acid decomposition and ICP-MS method. There are two types of X-ray fluorescence spectrometry methods energy dispersive and wavelength dispersive XRF (EDXRF and WDXRF). Both types have been demonstrated to be suitable for aerosol analysis (3),(4), but * SBU WDX, X-ray Instrument Division, Rigaku Corporation. EDXRF systems are often times preferred over WDXRF due to fewer installation requirements (5). Especially when using the Rigaku EDXRF instrument NEX CG which is equipped with secondary targets for polarized irradiation, superior measurement results can be obtained due to lower background levels and LLD. The characteristics of polarized EDXRF, quantitative calculation process with thin film FP method and analysis results of real samples are introduced. 2. Experimental setup 2.1. System The Rigaku EDXRF spectrometer NEX CG is shown in Fig.1 and its specifications are shown in Table 1. It does not require any special utilities such as liquid nitrogen or cooling water since it is equipped with a thermoelectrically cooled semiconductor detector and air cooled X-ray tube. Secondary targets and polarized optics are illustrated in the left panel of Fig. 2. The right panel compares the spectrum of an oil sample for direct excitation to the spectrum obtained with NEX CG. It can be seen that NEX CG has superior peak to background (P/B) ratio resulting in higher sensitivity. The PM2.5 component analysis guideline mentions the use of secondary targets and polarized optics as well (2). Since the aerosol filter sample is not irradiated directly, damage to the sample due to X-ray irradiation is reduced. NEX CG has a wide measurement range from sodium (Na) to uranium (U) with high sensitivity. The monochromatic excitation by the Pd-Lα line allows ppm level analysis of the halogen chlorine (Cl) which is difficult to analyze with ICP. The measurement diameter is 20 mm and the measurements are performed under vacuum environment. It is also possible to measure in helium (He) atmosphere to prevent evaporation of volatile components such as Cl. The instrument can be equipped with up to five secondary targets which allows for measurements with high P/B ratio over a wide element range (6). 2.2. Quantitative analysis method For quantification, two methods are described in the established XRF guideline empirical and fundamental parameter (FP) methods, both of which can be performed with NEX CG. In case of the empirical method which uses standard samples for calibration, it is possible to obtain results with high precision. However, this requires the need to Rigaku Journal, 30(2), 2014 13

Table 1. NEX CG specification. X-ray tube Tube Power Secondary targets Detector Pd target, air cooled 50 W: 50 kv 2 ma (max) 5 targets (max) High performance Silicon Drift Detector (SDD) Fig. 1. Rigaku EDXRF spectrometer NEX CG. Fig. 2. Polarized optics and comparison to direct excitation optics of an oil sample (Spectra are normalized at Mo-Kα Compton scattered X-ray intensity). prepare many standard samples especially when there are many elements of interest (2). In addition, when peaks of elements of interest are overlapped by peaks from other elements, or if the amount of collected sample varies in weight, additional corrections need to be applied and reliability of analysis result decreases. Actual aerosol samples consist of many components resulting in complex spectra with many overlapping peaks. On the other hand, if FP method is used to perform semi-quantitative analysis, there is no need for standard samples since quantification is carried out based on the sensitivities that are pre-registered in the instrument. FP method is therefore also referred to as standardless analysis. When performing quantitative analysis with FP method, absorption and excitation effects due to co-existing elements are taken into account when calculating concentrations (or amount deposited on filter). Therefore, accurate analysis results can be obtained without the need to apply complex corrections even for samples which contain many elements. NEX CG is equipped with a FP calculation program that allows accurate quantitative calculation for thin film samples as described below (7). 2.3. Outline for semi-quantitative analysis software RPF-SQX The RPF-SQX (Rigaku Profile Fitting-Spectra Quant X) software (8) for standardless analysis combines FP method with full profile fitting. The sensitivities are precalibrated using pure materials to cover the analysis of elements Na to U. The computational scheme of RPF-SQX is summarized in Fig. 3. First (1), a sample is measured to obtain its spectrum. Next (2), the initial values of Fig. 3. Computational scheme of RPF-SQX (8). the thickness and contents of the sample is set. Then (3), a profile is constructed for each individual set element using the intensity obtained by the FP method and response function. The total spectrum is then calculated by summing up each individual profile. (4) The calculated total spectrum is then compared with the actual measured spectrum. The sample content and thickness are adjusted until both calculated and measured spectra match. The final result is obtained by fitting the entire spectrum, not just the peak intensity. The profile of each individual element is calculated using the FP method and the response function of the detector to match the measured spectrum. Since this method utilizes the theoretically calculated Rigaku Journal, 30(2), 2014 14

peak profile for each element in the fitting process, accurate quantitative results can be obtained even when complex overlaps exist. s can be further improved by calibrating the sensitivities using the matching library function (5). 2.4. RPF-SQX analysis for thin film sample For filter samples, it is necessary to use the thin film FP analysis method. RPF-SQX is also applicable to thin film samples by calculating theoretical XRF intensities with an additional term for sample thickness (9). The XRF intensity ratio of different line types varies with sample thickness. Figure 4 shows the Pb-Lβ and Pb-Lα intensity ratio for varying sample thickness. Due to self-absorption of Pb the intensity ratio of Lβ to Lα decreases as the sample becomes thinner. Therefore, in order to obtain accurate full profile fitting, it is necessary to perform profile fitting using the thin film FP method to reflect the effect of self-absorption. Figure 5 shows the measured and fitted spectra by the RPF-SQX method for polyethylene standard samples with different thicknesses. This sample contains not only Pb but also As, which Pb-Lα and As-Kα lines overlap with each other. It can be seen in Fig. 5(b) that the profiles of both analytical lines are constructed separately. Since the combined profiles to form the spectrum matches the Fig. 4. Relationship between Pb-Lβ to Pb-Lα intensity ratio and sample thickness. measured spectrum, accurate quantification results can be obtained even if sample thickness varies. This result demonstrates that RPF-SQX is able to calculate accurate results even when complicated overlaps exist or sample thickness varies (7). 3. Aerosol filter sample analysis 3.1. Analytical procedure for aerosol filter sample The analysis procedure of an actual aerosol filter sample is shown in Fig. 6. The aerosol filter is placed in a sample cup with the collected sample side facing down and an aluminum cup is placed on top to hold the filter. The sample cup is then placed in the turret. Information regarding the sample is set in the software. If EZ analysis mode is selected, measurement can be carried out with only a minimum amount of settings such as sample position or application type. Measurement time is typically several minutes to 1 hour. After measurement, the software automatically carries out spectral identification and RPF-SQX calculation to display the standardless analysis result. By using XRF method, analysis result can be obtained easily without any tedious sample preparation. 3.2. for aerosol filter samples The spectra of an aerosol filter standard sample (NIST SRM2783) measured with NEX CG are shown in Fig. 7. The energy ranges where the sensitivity is optimum for each secondary target are shown. Spectra with good P/B ratio are obtained over a wide energy range from light to heavy elements. The Na-Kα line can be clearly seen although the Zn-Lα and Zn-Lβ lines overlap. This shows that it is important to correct for line overlaps in order to obtain accurate analysis results. Table 2 shows the RPF-SQX result based on the spectra shown in Fig. 7. The result demonstrates that accurate analysis values can be obtained even without the use of standard samples. Since the effect of the immeasurable elements is not taken into consideration, Fig. 5. Spectra of polymer samples (BCR680: As 30.6 ppm Pb 107.6 ppm) with different thickness. (a) Measured spectra (b) Individual fitted spectra and quantified values obtained by RPF-SQX (7). Rigaku Journal, 30(2), 2014 15

the results for light elements are low. Reliability of analysis results of inorganic elements such as Al, K, Ca, V, Fe, Zn by the FP method has previously been confirmed by finding that the results correlate with ICP-MS analysis results (5),(10). 3.3. Lower Limit of Detection Figure 8 shows the LLDs for various elements for NEX CG. These values were determined by measuring MICROMATTER thin film standard samples. Measurement time is 300 sec for each secondary target. The LLDs are lower than 10 ng/cm 2, which corresponds to 5.2 ng/m 3 when converted to concentration in air assuming that the aerosol particles are collected on the Table 2. s of aerosol filter standard sample (NIST SRM 2783) using RPF-SQX analysis. Unit: ng/cm 2 Na Mg Al Si P S 187 95 865 610 2330 2220 (5880) 6400 100 (105) 206 Cl K Ca Ti Cr Mn 46 530 540 1325 1490 150 180 13.5 16.6 32.1 31 Fe Ni Cu Zn Pb Fig. 6. Flow chart of aerosol filter sample analysis with NEX CG. 2660 2760 6.83 8.3 40.7 48.4 180 208 31.8 38.9 ( ): not certified Fig. 7. Spectra of aerosol filter standard sample (NIST SRM 2783). Fig. 8. LLDs for each element. Rigaku Journal, 30(2), 2014 16

filter paper (diameter 47 mm, effective diameter 40 mm) at a flow rate of 16.7 L/min for 24 hours. 4. Summary Using NEX CG, analysis of atmospheric aerosol such as PM2.5 collected on filters can be easily and non-destructively carried out for a wide element range. RPF-SQX allows accurate analysis even if complicated line overlaps exist. In addition, analysis can be performed without the need to prepare standard samples since FP method assures sufficiently accurate results. NEX CG is therefore an effective tool for the analysis of PM2.5 and is expected to contribute to the advancement in this field. References ( 1 ) Japanese Ministry of the Environment, website; http://www.env. go.jp/air/osen/pm/info.html ( 2 ) Japanese Ministry of the Environment: the Guideline for Component Analysis of PM2.5 (2013). ( 3 ) M. Matsumoto, Y. Yamada, H. Yin and H. Quan: Journal of Environmental Chemistry, 8 (1998), 267 274, (in Japanese). ( 4 ) U.S. Environmental Protection Agency: Compendium Method IO-3.3 Determination of metals in ambient particulate matter using X-ray fluorescence (XRF) spectroscopy, (1999). ( 5 ) T. Okuda and K. Hatoya: Earozoru Kenkyu, 28 (2013), 214 221, (in Japanese). ( 6 ) T. Moriyama, S. Ikeda, M. Doi and S. Fess: Advances in X-ray Analysis, 54 (2011), 289 298. ( 7 ) T. Moriyama, A. Morikawa, M. Doi and S. Fess: Advances in X-ray Analysis, (in press). ( 8 ) S. Hara, N. Kawahara, T. Matsuo and M. Doi: DXC2010, Denver, (2010). ( 9 ) Y. Kataoka and T. Arai: Advances in X-ray Analysis, 33 (1990), 213 223. (10) T. Okuda, E. Fujimori, K. Hatoya, H. Takada, H. Kumata, F. Nakajima, S. Hatakeyama, M. Uchida, S. Tanaka, K. He, Y. Ma and H. Haraguchi: Aerosol and Air Quality Research, 13 (2013), 1864 1876. Rigaku Journal, 30(2), 2014 17