X-Mind. Instinct for perfection

Similar documents
X-Mind. Instinct for perfection

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Digital Dental X-ray. Midmark Animal Health Products

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

WARNING: We recommend that you consult the Safety, Regulatory and Technical Specification User Guide before using the CS 2200.

user's manual _19

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

RVG Full range imaging for diagnostic confidence ROBUST DESIGN SUPERIOR ERGONOMICS NEW IMAGE PROCESSING TOOLS ENHANCED WORKFLOW

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Dental Radiography Core Subject. Digital Radiography

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

JB-70 Dental X-Ray System

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

microscope OP-Dent-5

How To Use A Ds340 (Dsp)

OLI. Oil level indicator

Digital panoramic X-ray for practical diagnostics

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

X-ray Imaging Systems

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

TIG INVERTER INSTRUCTION MANUAL

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

Voltech DC1000. Precision DC Bias Current Source

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

Split units TH with hermetic compressors

Drayton Digistat +2RF/+3RF

ALARMLINE ANALOGUE Linear Heat Detection System

Electro-Pneumatic Bus Door Control Mechanism

X-ray Imaging Systems

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

KS-70. Catheterization Table GENERAL

1.44 kw Programmable DC Power Supplies XLN Series

Worldwide network in over 40 countries.

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Production of X-rays and Interactions of X-rays with Matter

Systematic X-ray diagnostics as flexible and individual as your dental practice.

Technology for ICU and minor surgery

Radiation safety in dental radiography

EPA Protocols: Compliance testing of dental X-ray apparatus used for plain radiography

Motion Activated Camera User Manual

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

5000V Graphical Megohmmeter Model 5070

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multi-Range Programmable DC Power Supplies 9115 Series

CADB and CADT-D / DI / DC Series

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Good EMC Design Principles: cable routing

14. Troubleshooting Guide

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Multi-Range Programmable DC Power Supplies 9115 Series

CYMAQ Marking System AS200 + DS7050 N-14

Laserlyte-Flex Alignment System

Heating oven with mechanical convection

DC Electronic Loads 8500 series

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

Digital Keypad Use s Manual

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Maxi sky 600. with people in mind

helosauna.com STEAM BATH PRODUCTS

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

Rodenstock Photo Optics

FIREDEX Conventional Fire Panels

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

INTREPID Perimeter Intrusion Detection System

HERZ-Thermal Actuators

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SMART SENSOR COLLECTION

Perimeter Security System

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DENTAL Cone beam 3D X-RAY SYSTEM with

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

Phase Modular Finally the benefits of Modular ups are for all

Transmitter Interface Program

New XUY roller sensors

TA3 Dosimetry and Instrumentation. Evaluation of the Field Size in Dental Diagnostic Radiology System ANDRADE PS 1, POTIENS MP 1

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Transcription:

X-Mind Instinct for perfection

Instinct for speed Instinct for reliability X-Mind AC and DC generators are recognised for their reliability and consistent performance. Their double chamber light alloy heads are designed in one piece: the tube is in one chamber and the electronic components in another compartment in an oil bath (operating temperature regulation and high electrical insulation coefficient). The control software automatically compensates for variations in mains voltage, the radiation emitted is always of the best quality to provide pictures with reproducible parameters. Instinct for ergonomics The patented timer uses new technology which enables it to recognise automatically the type of generator and therefore to control an AC or DC X-Mind model, with their specific command options (the X-Mind timer can be connected to two AC and/or DC generators at the same time). The clearly organised commands make programming the X-rays easy thanks to the pictograms. The type of patient, the type of films or even special X-rays are easily managed. Exposure times can be customised and programmed. The electronics programme, which is compatible with both types of generator, enables the exposure time and radiation absorption to be reduced. The control panel manages exposure times that are perfectly suited to digital imaging with X-Mind DC (from 0.02 to 3.2 sec. in 23 stages). Using digital sensors reduces the exposure time by 75% compared with conventional intra-oral X-ray film. The X-Mind AC version has an exposure time optimised for use with the latest generation conventional intra-oral X-ray films (type F ), while being compatible with some digital sensors (from 0.08 to 3.2 sec. in 17 stages). Using F type films reduces radiation by 60% compared with D type films.

31cm (12 ) long cone, head rotates through 395. X-Mind timer : microprocessor-controlled, exposure time can be customised and programmed, one key allows you to switch immediately from conventional intra-oral X-ray to digital X-ray. Pre-programmed keys for special pictures. X-Mind DC exposure times are optimised for use with digital sensors. The generator is compatible with practically all digital imaging systems. Polycarbonate locating cone : 0.7mm focal length for precise pictures, 31cm distance between skin and focal spot for better protection.

X-Mind DC The new X-Mind DC generator is fitted with a Toshiba DG-073B-DC double anode tungsten tube (intensity of 4mA and 8mA), it generates a constant voltage of 60kV or 70kV. It operates at high frequencies and constant potential which enables very high quality radiation to be emitted, whatever the conditions of use. The choice of voltage (60 or 70kV) and intensity (4 or 8mA) enables optimal diagnosis of intraoral X-rays with a 35% reduction in exposure time, compared with monophased units. The timer can control up to two DC generators. The extremely short exposure times (minimum 0.02 sec.) are suitable for digital radiology with CCD, CMOS or phosphor plate sensors (radiation is 50% less that that used with E type films). Three wall-mounting extensions are possible for two installation types. An arm extension for fitting to the chair, on a column or to the ceiling and a mobile version, are available as options.

X-Mind AC The new X-Mind AC generator is fitted with a Toshiba DG-073B monophased auto rectifier tube. It generates a high 70kV voltage with an ideal intensity of 8mA. Concentrated, high density radiation in a very small diameter focal spot (0.7mm) for greater accuracy. Supplied with a long cone as standard, the generator is perfectly suited to the parallel technique (a short cone* and a rectangular cone are available as options). The rays emitted have a large wavelength and provide pictures characterised by a widespread grey scale for better distinction of anatomical detail. The new timer is programmed for use with D, E or F type films. It can be installed remotely and can control one or two units whatever the technology: AC + AC or AC + DC. Which makes the X-Mind concept unique, probably giving it the best flexibility of use in intra-oral radiography. X-Mind generators are fitted with long cones recommended for the parallel technique. A short cone* for the bisector technique or a rectangular cone that reduces the rays applied to the patient s skin by 50%, are available as options. Rectangular cone (44 x 35mm). Short cone* 20cm (8").

Instinct for protection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in traditional configurations. The way leakage radiation is filtered (equivalent to 2mm A1 at 70kV) and controlled (less than 0.25mGy/h at 1m from focal spot) also gives maximum protection to the practitioner and personnel. The control button fitted with a safety system and exposure time control pre-defined by microprocessor ensure that a constant dose is administered to the patient. This technology avoids having to retake X-rays in the case of underor over-exposure. Instinct for movement The X-Mind range pantograph arms provide great flexibility of use and accurate positioning. The new, light alloy mechanism has smooth contours and protective casing at the joints. It is easy to keep clean and can be decontaminated in compliance with the strictest demands of asepsis in dental practice. Three extension arms are available (wall mounting): 41cm (16.2"), 82.5cm (32.5") and 110cm (43.5"), giving reaches respectively of 143cm, 184cm and 212cm (with a long cone). The numerous control systems make X-Mind AC and DC very safe to use: self-diagnosis of control panel elements each time it is started up, check of the electric installation parameters by the timer and automatic compensation of the exposure time depending on variations in mains voltage ensure very high quality performance. Although the equipment has been preprogrammed at the factory all exposure times can be customised or programmed; furthermore, one button allows you to switch instantly from conventional intra-oral X-ray film to digital sensors, in order to meet the dental practitioner s needs in the most flexible manner possible (the default settings can easily be reinstalled at any time). intelligence too

X-Mind AC Classification: Electromedical equipment, Class 1 type B Supply voltage: 220/230/240V~ - monophase 50/60Hz Power absorption at 220V: 0.8kVA Resistance of the line: 0.5ž X-ray tube: New Toshiba DG 073B tube High voltage: 70kV Anode current: 8mA Focal spot: 0.7mm Total filtration: Equivalent to 2mm Al at 70kV Tube inherent filtration: Equivalent to 0.8mm Al at 70kV Leakage radiation: Less than 0.25mGy/hour maximum at a distance of 1m from focal spot Long cone: Focus to cylinder tip distance = 31cm (12 ) Timer: Exposure time can be set from 0.08 to 3.2 seconds X-ray emission control: Dead man switch with 3m spiral cable Total weight: 28kg (weight of the head: 9kg) Manufactured in compliance with currently applicable regulations and standards (EC Directive 93/42/EEC) X-Mind DC Classification: Electromedical equipment, Class 1 type B Supply voltage: 230V~ - monophase 50/60Hz Power absorption at 230V: 1.4kVA Resistance of the line: 0.5ž X-ray tube: New Toshiba DG 073B DC tube High voltage: 60-70kV Anode current: 4-8mA Focal spot: 0.7mm Total filtration: Equivalent to 2mm Al at 70kV Tube inherent filtration: Equivalent to 0.8mm Al at 70kV Leakage radiation: Less than 0.25mGy/hour maximum at a distance of 1m from focal spot Long cone: Focus to cylinder tip distance = 31cm (12 ) Timer: Exposure time can be set from 0.02 to 3.2 seconds X-ray emission control: Dead man switch with 3m spiral cable Total weight: 25kg (weight of the head: 5.5kg) Manufactured in compliance with currently applicable regulations and standards (EC Directive 93/42/EEC) OPTIONAL EQUIPMENT Short cone*: Focus to cylinder tip distance = 20cm (8 ) Rectangular cone: Cross section 44x35mm; Length = 31cm (12") Wall-mounting arm: 0.40m or 1.10m Ceiling arm Unit arm Mobile Inverted wall mounting: 0.40m or 0.80m or 1.10m Second control button with extension cord RX indicator light for external use *short cone not available in UK 17 av. Gustave Eiffel BP 216 33708 MERIGNAC cedex FRANCE Tel +33 (0) 556 34 06 07 Fax +33 (0) 556 34 92 92 E-mail: satelec@acteongroup.com www.acteongroup.com