ICQ Series - square centrifugal

Similar documents
ICQ Series - square centrifugal

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Multistage high-pressure multistage centrifugal pumps

TFSR & TFSK Roof Fans

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

FAN & BLOWER CENTRIFUGAL FANS

Energy Saving ECM Motors and Fans Ventilation Catalogue

CRK A-W-A-BUBV

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Surface Technology. Centrifugal Fan GMD

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

EC medium pressure axial fans. The effi cient system solution.

TURBOWENT TULIPAN - rotary chimney cowl Ø150

1 Temperature Derating Guide

Butterfly Valves PN 6/10/16 for flanged connection

Chapter 3.5: Fans and Blowers

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

We will discuss common industrial applications with guides for the proper use of electric motors on these.

ECOCIAT. Domestic hot water heat recovery unit

Transformer oil cooler ALFA A02

CADB and CADT-D / DI / DC Series

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Screw Compressors ESM Fixed Speed & VS Variable Speed

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

CRN A-F-G-E-HQQE 3x400D 50 HZ

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

SUNON SPECIFICATION FOR APPROVAL

RPV - RP - RA air handling units

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Operataing Manual. Single stage radial Fan. Model MKV/TKV

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

Horizontal Jet Pumps 1/3-1-1/2 HP

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Centrifugal Fans direct driven with scroll. Issue 1.3 November 2012

Product Brochure. Certified Mining Motors

Commercial Gas Furnace Upflow

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

MODEL HSR-007 Direct Drive Rolling Steel

Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

squrboxbox heat recovery squrboxbox I technical information

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

FAN SYSTEM REPLACEMENTS IN HVAC EQUIPMENT TO IMPROVE ENERGY

SECTION MORTUARY REFRIGERATORS

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Conlift1, Conlift2, Conlift2 ph+

300 Series PA Pump and Cooler Assemblies

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

The conditions below apply to the curves shown on the following pages.

HORIZONTAL PUMPING SYSTEM

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

PM734F - Technical Data Sheet Winding 28

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

A S Y N C H R O N O U S M O T O R S

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.

Borstlösa DC-motorer. Promoco Scandinavia AB

The ventilation of the future.

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Application. Design. Structure. Acoustics

AC Replacement for DC Mill-Duty Motors

BASIS RANGE TMB SERIES

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview

Standard offering (pumps)

Data Center Cooling. The engineer s choice

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

AC axial fans A series

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

Waterjets. propulsors. courtesy of Austal

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Air Comfort. Technical Catalogue > Roof Fan STOF

Installation and maintenance instructions. Danfoss Vent

A X I A L M I X E D F L O W C E N T R I F U G A L

industry revolves around

LUCCI AIRFUSION QUEST II CEILING FAN

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Explosion Proof Dynamic Brushless Servo Motors

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved

Transcription:

product ICQ Series - square centrifugal dimensions mm 28-71 poles & duty 4-8 / up to 4,5 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ series is a range of inline duct mounted fans for use in general ventilation systems. All models are built around high performance centrifugal impellers driven by totally enclosed fan cooled (TEFC) or external rotor motors (ERM). Note that single phase ICQ series fans are only available in ERM models. Construction Cases are fabricated from galvanised sheet steel with standard duct flanges for easy installation. Impellers are high efficiency backward curve centrifugal type. The impeller and motor assembly is supported by a robust galvanised steel frame for long, trouble free service. Motors Motors are of TEFC or ERM design. Motor enclosure feature IP54 protection as standard with higher ratings are available on request. Motor windings incorporate class F insulation as standard although class H is readily available. Motor bearings are sealed for life and maintenance. Suggested Specification Centrifugal Flow duct mounted type fans shall be of the ICQ Series manufactured by Pacific HVAC Engineering. Backward Curved Centrifugal impellers shall be driven by TEFC motors with sealed for life bearings. Cases incorporating standardized flanges to be of galvanised sheet steel with cross breaks in larger sizes for added strength and noise minimisation. All fans shall be fully tested in accordance with the requirements of ISO 581 : 27 for air flow and ISO 13347 : 24 for sound. Features High reliability TEFC or ERM motors with sealed for life bearings. Class H available across all sizes. EXE, EXD, motors available across the range. High performance backward curve centrifugal impellers. Perfectly suited to medium/high volume and pressure applications. Fully speed controllable. Fans can be mounted at any angle. Testing Rated fan performance has been determined by testing to ISO 581 : 27. Fan sound data has been determined by testing to ISO 13347 : 24. Wiring diagrams and latest data Refer to the latest product datasheet for individual model wiring instructions, data and specifications. Datasheets are available from our electronic selection software FansSelect downloadable at www.pacifichvac.com It is a condition of our warranty that all equipment supplied is installed according to the requirements of AS/NZS3:27 Australian/New Zealand wiring rules. Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326

Fan Data - TEFC Motor (All Three Phase) Fan Model Full Load Current Motor kw Shaft Revs /sec db(a)@ 3m SPL db referred to 1-12 W Type D: ducted inlet/outlet (LW) 63 125 25 5 1K 2K 4K 8K ICQ-4DD 1.26.55 24 46 77 75 69 66 59 55 54 51 ICQ-6DD.99.37 16 4 67 69 6 6 54 51 46 42 ICQ-4DD 1.26.55 24 51 75 78 72 71 61 63 59 52 ICQ-6DD.99.37 16 43 65 69 64 63 58 51 46 44 ICQ-4DD 1.26.55 24 54 79 81 75 73 66 66 65 58 ICQ-6DD.99.37 16 44 7 72 67 63 58 55 52 47 ICQ-8DD 1.23.37 12 37 63 65 6 56 51 48 45 4 ICQ45-4DD 1.7.75 24 56 78 81 77 75 69 69 67 63 ICQ45-6DD.99.37 16 44 74 75 68 65 59 58 55 5 ICQ45-8DD 1.23.37 12 39 67 68 61 58 52 51 48 43 ICQ5-4DD 2.37 1.1 24 6 81 85 81 76 74 74 69 71 ICQ5-6DD.99.37 16 5 74 8 72 66 63 61 58 55 ICQ5-8DD 1.23.37 12 43 67 73 65 59 56 54 51 48 ICQ56-4DD 4.38 2.2 24 65 86 93 88 8 78 78 73 72 ICQ56-6DD 1.66.55 16 53 78 82 75 7 66 66 62 61 ICQ56-8DD 1.23.37 12 44 7 72 66 6 58 56 55 5 ICQ63-4DD 7.68 4 24 68 83 97 9 81 84 81 78 75 ICQ63-6DD 2.62 1.1 16 57 74 87 81 71 74 71 68 66 ICQ63-8DD 1.71.55 12 51 68 81 75 65 68 65 62 6 ICQ71-6DD 4.83 2.2 16 61 85 9 86 75 73 71 7 68 ICQ71-8DD 2.91 1.1 12 47 72 75 72 61 61 57 56 53 ICQ71-1DD 2.91.917 1 42 67 7 67 56 56 52 51 48 Ancillaries Fan Performance - TEFC Motor - Three Phase 5 45 35 3 25 2 15 1 5 ICQ - 4 Pole (Three Phase TEFC).2.4.6.8 1 1.2 1 9 8 7 6 5 3 2 1 ICQ - 4 Pole (Three Phase TEFC) 56 5 45.5 1 1.5 2 2.5 3 3.5 Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326

Fan Performance - TEFC Motor - Three Phase ICQ - 4 Pole (Three Phase TEFC) ICQ - 6 Pole (Three Phase TEFC) 12 25 1 2 8 6 2 63 15 1 5 1 2 3 4 5.2.4.6.8 ICQ - 6 Pole (Three Phase TEFC) ICQ - 6 Pole (Three Phase TEFC) 45 7 35 3 25 2 15 1 5 45 5 56 6 5 3 2 1 63 71.5 1 1.5 2 2.5 1 2 3 4 5 ICQ - 8 Pole (Three Phase TEFC) ICQ - 8 Pole (Three Phase TEFC) 2 18 16 14 12 1 8 6 4 2 45 5 35 3 25 2 15 1 5 56 63 71.2.4.6.8 1 1.2.5 1 1.5 2 2.5 3 3.5 3 ICQ - 1 Pole (Three Phase TEFC) 25 2 15 1 5 71.5 1 1.5 2 2.5 3 Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326

Fan Data - ERM - Single Phase Fan Model RPM Voltage Amps kw SPL db referred to 1-12 W Type C: ducted inlet, free out. 63 125 25 5 1K 2K 4K 8K db(a)@3m ICQ28-4EE 142 24.35.78 75 7 67 62 55 52 51 48 43 ICQ28-6EE 96 24.35.38 67 62 6 54 47 44 43 4 35 ICQ-4EE 143 24.5.115 71 7 65 66 58 53 49 47 45 ICQ-6EE 96 24.5.6 67 65 59 6 53 47 43 41 39 ICQ-4EE 142 24 1.12.245 76 74 71 62 54 52 5 43 45 ICQ-6EE 87 24.31.7 67 64 64 58 51 46 44 4 39 ICQ-4EE 137 24 2.4.48 71 76 73 67 63 57 57 53 49 ICQ-6EE 895 24.68.155 63 68 65 59 55 49 49 45 41 ICQ45-4EE 125 24 3.68 71 72 74 71 66 61 6 49 51 ICQ45-6EE 93 24 1.42.3 71 7 63 63 55 54 5 4 43 ICQ5-4EE 1375 24 5.2 1.43 73 77 77 74 71 67 64 59 55 ICQ5-6EE 95 24 2.2.5 65 69 69 66 63 59 56 51 47 ICQ56-6EE 885 24 4.35.78 64 69 66 66 63 56 55 52 47 Fan Performance - ERM - Single Phase 35 ICQ - 4 Pole (Single Phase ERM) 3 25 2 15 1 5 28.1.2.3.4.5 ICQ - 4 Pole (Single Phase ERM) 45 35 3 25 2 15 1 5.2.4.6.8 1 1.2 7 ICQ - 4 Pole (Single Phase ERM) 6 5 3 2 1 45 5.5 1 1.5 2 2.5 Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326

Fan Performance - ERM - Single Phase 16 ICQ - 6 Pole (Single Phase ERM) 14 12 1 8 6 4 2 28.5.1.15.2.25.3.35 ICQ - 6 Pole (Single Phase ERM) 2 18 16 14 12 1 8 6 4 2.1.2.3.4.5.6.7.8 ICQ - 6 Pole (Single Phase ERM) 35 3 25 2 15 1 5 45 5 56.5 1 1.5 2 2.5 ICQ Size A B C kg 28 35 41 445 22 5 41 445 28.8 55 45 485 34.1 55 5 535 38.8 45 6 55 585 45.9 5 65 65 685 57.7 56 75 7 735 71.7 63 8 8 835 95.7 71 85 9 935 112.4 Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326

Fan Data - ERM - Three Phase Fan Model RPM Voltage Amps kw SPL db referred to 1-12 W Type C: ducted inlet, free out. 63 125 25 5 1K 2K 4K 8K ICQ-4DE 142 415.35.125 71 7 65 66 58 53 49 47 ICQ-6DE 125 415.15.85 67 65 59 6 53 47 43 41 ICQ-4DE 1 415.52.17 76 74 71 62 54 52 5 43 ICQ-6DE 12 415.22.13 68 65 65 59 52 47 45 41 ICQ-4DE 1415 415 1.41.515 71 76 73 67 63 57 57 53 ICQ-6DE 1235 415.7.385 63 68 65 59 55 49 49 45 ICQ45-4DE 135 415 1.48.73 71 72 74 71 66 61 6 49 ICQ45-6DE 93 415.75.29 71 7 63 63 55 54 5 4 ICQ5-4DE 138 415 2.8 1.45 73 77 77 74 71 67 64 59 ICQ5-6DE 915 415 1.2.52 65 69 69 66 63 59 56 51 ICQ56-4DE 135 415 4.7 2.41 76 81 78 78 75 68 67 64 ICQ56-6DE 89 415 1.68.78 64 69 66 66 63 56 55 52 ICQ63-4DE 117 415 1.74 3.31 88 86 87 83 81 76 73 69 ICQ63-6DE 88 415 2.8 1.31 73 72 73 69 64 62 59 55 Fan Performance - ERM - Three Phase db(a) @3m 45 39 45 4 49 41 51 43 55 47 59 47 65 5 ICQ - 4 Pole (Three Phase ERM) ICQ - 6 Pole (Three Phase ERM) 5 45 45 35 3 25 2 15 1 5 35 3 25 2 15 1 5.2.4.6.8 1 1.2.2.4.6.8 1 1.2 ICQ - 4 Pole (Three Phase ERM) ICQ - 6 Pole (Three Phase ERM) 9 8 35 7 6 5 3 2 1 45 5 56 3 25 2 15 1 5 45 5 56.5 1 1.5 2 2.5 3 3.5.5 1 1.5 2 2.5 ICQ - 4 Pole (Three Phase ERM) ICQ - 6 Pole (Three Phase ERM) 12 6 1 5 8 6 2 63 3 2 1 63.5 1 1.5 2 2.5 3 3.5 4.5 1 1.5 2 2.5 3 3.5 Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326