ADU68140 SERIES AC or DC Distribution Unit for DAC60000 Inverter Systems

Similar documents
Contractors Guide Central Inverter System Installation

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installing Cisco TelePresence MX200 G2 - Wheel Base

Transformers from 25va to 500kva. Standard despatch in days not weeks

Safety technique. Emergency stop module BO 5988 safemaster

instabus KNX / EIB System System E F G H

HERZ-Thermal Actuators

Product and functional description

Inverter / Charger Installation General Operations and AC and DC Connections

How To Test A Power Distribution Unit

E-STOP relays, safety gate monitors

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

The power module is Feature Number 8800-F2-901.

Quick Connect. quick - simple - efficient.

16/32 Channel 1U Rack Mount CCTV Power Supply

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Remote Monitoring and REC 501 Control Unit Product Guide

8146/5 Series Breaker Panelboards

12 Series - Time switches 16 A. Features

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Auxiliary equipment for communication with the EuroProt protective devices

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Switchboard system. NorLine 800

ZC-24DO CANopen I/O Module: 24 Digital Outputs

MPR-Systems. Mini Power Racks 1200 W W

HM-W536 Install Guide

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Application/Connection Examples

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

FIREDEX Conventional Fire Panels

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Instruction Manual for Operating Panel 301 and 302

R.C.C.B. s two-pole LEXIC

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Contact expander modules

PNOZsigma - Base units

GAE953 Electrical Alarm Unit 19" with Indicator

38 Series - Relay interface modules A

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

CO2 Alarm. Operation. Application

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue

MCR1900 Media Converter 19-Slot Chassis

Thyristor power units and Solid state contactors. TC2000 series. Two-phase control of a three-phase load or control of two single-phase loads

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Contact expansion modules

4KVA/5KVA Parallel Installation Guide

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

API Marine. BMS Presentation. Ballast Measurement Systems

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Relay mounting systems

MidNite Solar PV Combiners explained (MNPV)

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Tmax MCCBs. Molded case circuit breakers. Tmax

1.44 kw Programmable DC Power Supplies XLN Series

How To Use A Power Supply On A Powerline 2.2 (Ai)

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

Thyristor-controlled power supplies and battery chargers

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Installation Instructions

KNX R. Rain Sensor. Installation and Adjustment

SolarEdge Installation Guide MAN Cover goes here (right-side [odd] page)

MOTOR PROTECTIVE DEVICES

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Modular I/O System Analog and Digital Interface Modules

TMS TANK MANAGEMENT SYSTEM

Accessories SUNNY REMOTE CONTROL

EuroSynth FracRak Comparisons

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Low Voltage Products. Switches Automatic Transfer Switches

DCS Input/Output Relay Card Series

Emergency lighting units EM powerled

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

CutMaster Major External Replacement Parts

HCE80/HCC80/HCE80R/HCC80R

E-STOP relays, safety gate monitors

Installation manual. Generator Paralleling Controller GPC multi-line C

IEC 309 INTERLOCKS NORTH AMERICAN

3500/93 System Display

CutMaster Major External Replacement Parts

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

Photovoltaic Solar Energy Unit EESFB

E-STOP relays, safety gate monitors

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Transcription:

ADU68140 SERIES AC or DC Distribution Unit for DAC60000 Inverter Systems Cable entry from rear Output terminals of fused ouput line Output terminals of non fused output line PE output terminals MCBs with auxiliary alarm contact 2-pole MCBs Schuko Power outlet Input terminals Input switch 2-pole 125A Output breakers: Max 20pcs 1-pole Output MCBs (Max 10pcs 2-pole MCBs) Optional: 3-phase distibution RCD Residual current device DISTRIBUTION UNITS (WITHOUT MCBs) Type Description Max nom. voltage AC/DC, Dimensions max current ADU68140 1-pole distribution unit, 1-20 MCBs 230VAC/125VDC, 125A 19 3.5U, depth 109mm excluding MCBs ADU68141 2-pole distribution unit, 1-10 MCBs 230VAC/125VDC, 125A 19 3.5U, depth 109mm excluding MCBs ADU68142 Distribution unit with 1-5pcs of Schuko power outlets 230VAC, 80A 19 3.5U, depth 109mm excluding MCBs ADU68143 1-pole distribution unit, 16mm2 connectors, 1-15 MCBs 230VAC/125VDC, 125A 19 3.5U, depth 109mm excluding MCBs 1-POLE MCB ALTERNATIVES FOR ADU68140 DISTRIBUTION Type / Description Type / Description Type / Description Type / Description 54100100 1A C-curve 54100600 6A C-curve 54101600 16A C-curve 54102500 25A C-curve 54100200 2A C-curve 54101001 10A B-curve 54102001 20A B-curve 54103201 32A B-curve 54100400 4A C-curve 54101000 10A C-curve 54102000 20A C-curve 54103200 32A C-curve 54100601 6A B-curve 54101601 16A B-curve 54102501 25A B-curve 54104001 40A B-curve 2-POLE MCB ALTERNATIVES FOR ADU68141 DISTRIBUTION Type / Description Type / Description Type / Description Type / Description 54100401 4A C-curve 54100604 6A C-curve 54101002 10A C-curve 54101602 16A C-curve SCHUKO POWER OUTLETS FOR ADU68142 AC DISTRIBUTION Type: 55990011 16A Schuko power outlet AUXILIARY ALARM CONTACT FOR ADU68140, ADU68141 OR ADU68143 Type Description 54430000 Auxiliary alarm contact for 1-pole or 2-pole MCBs, ½ module width. Alarm activated if MCB manually turned off or tripping in operation. 54430001 Auxiliary alarm contact for 1-pole or 2-pole MCBs, ½ module width. Alarm activated only if MCB tripping in operation. Sales & R&D Martinkyläntie 43, FI-01720 VANTAA, Tel. +358 10 2890 700 E-mail marketing@powernet.fi, service@powernet.fi Internet www.powernet.fi

Operating and connecting the AC-distribution unit 1. General ADU68140 series is designed for AC-distribution of Powernet DAC60000 inverter systems. Units can be used also for DC-distribution systems. Distribution unit may have up to 20pcs of 1-pole MCBs, up to 10pcs or 2-pole MCBs or up to 5pcs of schuko power outlets. Auxiliary alarm contact can be included to 1-pole or 2-pole MCBs. Optionally the distribution unit may include also residual current devices (RCD) or 3-phase distribution. In large systems several distribution units can be used to reach required number of MCB outputs. MCBS are operated from front panel and cable entry from rear or left or right side of the 19 sub-rack. 2. Mounting the distribution unit to 19 The frame unit is mounted to the 19 rack cabinet by 4pcs of M6 (M5) screws from the front panel. ADU68140 units do not require additional space between other 19 sub-racks. 3. ADU unit front panel Remove the front panel by releasing M3 screws (4pcs) before connecting cables. After cable connection fasten it back to original position. Coverplates for MCBs are mounted in factory based on MCB quantity in order. These can be modified later in field if more MCBs are installed. 4. Connecting the cables See figures 1-8: 4.1 Cable Entry Cable entry for input and output cables can be done either from rear side of ADU unit or from right or left side of the 19 cabinet. There is plastic cable channel (refer figure 1) with several openings to make the optimal wiring based on application. There is separate screw terminal for input and output wires. Make sure of necessary strain relief of all cables in 19 cabinet. 4.2 Input connection Make sure that power is OFF before connecting input cables. Mains input L and N or DC + and - is connected to input switch S1 screw terminals. Separate PE rail is located inside the unit, which has galvanic connection to PE bolt in the rear side of the unit. S1 is 2-pole 125A switch to manually turn the unit ON or OFF. Choose correct input cable size based on based on maximum summary load of distribution unit. In maximum configuration (125A) 35mm 2 cable should be used. 4.3 Load connection 1-pole system (ADU68140, ADU68143) Make sure that power is OFF from ADU or from that MCB, which load is connected. Connect load 1 Live wire to free screw terminal in MCB 1 (U 1 F1 OUT 1 in diagram). Load 1 Neutral or non fused DC-line screw terminal (U 2 OUT 1) is located in U 2 rail and PE terminal (PE OUT 1) in PE rail above of MCBs. Repeat same procedure for all 1 20 load outputs. 4.4 Load connection 2-pole system (ADU68141) Make sure that power is OFF from ADU or from that MCB, which load is connected. Both U 1 and U 2 load wires are connected to MCB screw terminals. There is free screw terminals for U 1 and U 2 in MCB, PE outputs are in PE rail. Repeat same procedure for all 1 10 load outputs. 4.5 Grounding Make sure that power is OFF before connecting cables. Connect the grounding cable to the PE bolt X1 or to free terminal in right side of PE rail. Choose correct cable size based on based on max summary load of distribution unit.

Grounding terminal Plastic cable channel: Entry from rear or left or right side of 19 cabinet Grounding bolt Figure 1: ADU68140 1-pole distribution mechanical layout Figure 2: ADU68140 1-pole distribution internal wiring diagram

Figure 3: ADU68141 2-pole distribution mechanical layout Figure 4: ADU68141 2-pole distribution internal wiring diagram

Figure 5: ADU68142 Schuko power outlet distribution mechanical layout Figure 6: ADU68142 Schuko power outlet distribution internal wiring diagram

Figure 7: ADU68143 1-pole distribution mechanical layout Figure 8: ADU68143 1-pole distribution internal wiring diagram