Manual. Appendix. Autotransformer ATR-32A ATR-100A. Apendix

Similar documents
Manual. Solar Fountain Mobile Phone Charger

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Manual. VE.Bus to NMEA 2000 interface

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Phoenix MultiPlus. Multi-functional inverter / battery charger with intelligent shore and generator power management

Stroom voor elke toepassing

Achieving the impossible

Thyristor-controlled power supplies and battery chargers

USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG

victron energy USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG Phoenix 12/220 Phoenix 24/220 Phoenix 48/220

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

BB800 Off-Grid Solar System

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

E Manual N Phoenix

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Using the Phoenix MultiPlus

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

TMS TANK MANAGEMENT SYSTEM

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

User s Manual Before using the inverter, you need to read and save the safety instructions.

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

ICON Server box installation manual Rev. 1.1

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

FW-X240 AUTO TRANSFORMER Installation Manual

TIG INVERTER INSTRUCTION MANUAL

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Definition AC Power Distribution

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

4KVA/5KVA Parallel Installation Guide

ENERGY. ANYTIME. ANYWHERE. MARINE

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

ACS-30-EU-EMDR-10-MOD

IEC 309 INTERLOCKS NORTH AMERICAN

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

user guide Meridian 558 Multi Channel Power Amplifier

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Connecting your Victron product to a computer with VE Configure

Automatic management of two different energy sources

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Current transformers (CT) & Shunts

OFF-GRID BACK-UP & ISLAND SYSTEMS

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Solid State Timers Type F

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

BITMAIN. APW PSU Series User Guide

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

6 Buck Boost Transformers

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Pluggable interface relays CR-P Pcb relays

4.0 UPS dedicated to ICT for unmatched energy savings

SURGE PROTECTIVE DEVICES

Emergency lighting units EM powerled

MidNite Solar E-Panels Explained

Operating Instructions

8146/5 Series Breaker Panelboards

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Charge Controller CC611/CC612 Preliminary datasheet

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

ASSEMBLED SOCKET-COMBINATIONS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Freedom SW Sine Wave Inverter/Chargers

10000HXL31/15000HXL31/20000HXL31

Electronic, Digital and Mechanical Vibration Switches

Technical data UNIBLOCK UBSF

Transcription:

Manual EN Appendix Apendix Autotransformer ATR-32A ATR-100A

The autotransformer: for step-up, step down and split phase balancing An autotransformer can be used for step-up, step-down and split phase output balancing purposes. While the step-up and step-down functions are fairly straightforward, split phase output balancing may require some more attention. EN Appendix Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V clothes washer could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity. Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum. The solution is an autotransformer. By leaving the neutral of the split phase supply unused, and connecting an autotransformer to create a new neutral, as shown in figure 1, any load unbalance is absorbed by the autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the autotransformer. The current through both 120V wires of the split phase supply will be 30A. 2

Ground relay for use with Multi or Quattro inverter/chargers included When operating in inverter mode, the neutral output of the inverter/charger must be connected to ground to guarantee proper functioning of a GFCI. In case of a split phase supply the neutral must be grounded. For this purpose a grounding relay is built in the autotransformer enclosure. The relay is controlled by the 230/240V Multi or Quattro. (The internal grounding relay in the 230/240V Multi or Quattro must be disabled) Temperature protected In case of overheating, the autotransformer is disconnected from the supply. Reset is manual. An alternative to stacked inverters The alternative to stacking two 120V inverters to provide a 120/240V split phase supply is a 240V inverter with an additional autotransformer. Two stacked 120V 3kVA inverters will supply up to 25A to each 120V leg. If the load on one leg is less than 25A, the maximum load on the other leg is still limited to 25A. One 240V 5kVA inverter with a 32A autotransformer will supply up to 21A of balanced load to each 120V leg. Less load on one leg will however result in more power being available on the other leg, with a maximum unbalance of 32A. Therefore the load can be up to 38,5A on one leg if the load is not more than 3,5A on the other leg. (maximum unbalance: 38,5 3,5 = 35A). If load unbalance is to be expected, a lower power 240V inverter with autotransformer will therefore be preferable to the stacked inverter solution. 3

4. Specifications Autotransformer 32A 100A Input/output voltage 120 / 240V Input circuit breaker 32A, two pole 100A, two pole Frequency 50/60Hz 240V to L1,L2 current 32A 100A Neutral current, 30 min 32A (3800VA) Neutral current, continuous 28A @ 40ºC/100ºF Transformer type Toroidal Enclosure Aluminium Input circuit breaker yes Protection category IP21 Safety EN 60076 Weight 12,5 Kg 13,5Kg Dimensions (h x w x d) 375 x 214 x 110 mm 425 x 214 x 110 mm EN Appendix 4

5. Operation 1.1 On/Off switch The MCB for over current and temperature protection and ON/OFF switch The Autotransformer is ON Push little blue switch Switch the MCB ON The green LED is on 5

1.2 Temperature protection In case of overheating, the autotransformer is disconnected from the supply. Reset is manual. When the transformer is warm the fan will blow and the RED led is on. EN Appendix Disconnect some of the 120V load. When the transformer is overheated the MCB will switch off. The little blue switch will be out of the MCB. Push little blue switch Switch the MCB to ON The Autotransformer is on. The green LED is on. 6

1.3. Over current protection In case of over current the MCB will switch off. The little blue switch remains inside the MCB Disconnect some of the load. Switch the MCB to ON The Autotransformer is on. The green LED is on. 7

APPENDIX A: EN Appendix Figure 1 - Split phase supply for unbalanced load (Ground relay of autotransformer should be used) Figure 2 - Autotransformer: schematic 2

EN Appendix Figure 3 - Step-Up: 120VAC to 240VAC (Internal ground relay of inverter/charger may be Figure 4 - Split phase: 120VAC to 120/240VAC (Internal ground relay of inverter/charger may be used) 3

EN Appendix Figure 5 - Stacked inverter balancing (Ground relay of autotransformer should be used) Figure 6 - Generator Balancing (neutral of generator should be connected to ground) 4

APPENDIX B: wiring diagram EN Appendix Wiring diagram: MTR-32 Wiring diagram: MTR-100 5

Victron Energy Blue Power Distributor: Serial number: Version : 02 Date : 10 july 2013 Victron Energy B.V. De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone : +31 (0)36 535 97 00 Customer support desk : +31 (0)36 535 97 03 Fax : +31 (0)36 535 97 40 E-mail : sales@victronenergy.com www.victronenergy.com