Advanced hotel systems



Similar documents
Advanced hotel systems

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

HCR3.2/.. Chipcard reader HOTEL SOLUTION

T5000 T000 LCD Digital Fan Coil Thermostat

IntesisBox KNX Modbus RTU master

HOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW

AC-115 Compact Networked Single Door Controller. Installation and User Manual

IntesisBox KNX Modbus TCP master

Controller board and power supply for vivimat III systems

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Passion for KNX innovation

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Hotel System Management The Hotel Smartest Solution

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Thermostat with display

Inwall Room Temperature Unit

Electronic Control Devices The European Product Catalogue 2007

HERZ-Thermal Actuators

ACR880 GPRS Portable Smart Card Terminal

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

TMS TANK MANAGEMENT SYSTEM

Inwall 4 Input / 4 Output Module

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

USB Plus+ RFID Reader Setup Guide

F454. Web Server. User Manual 05/12-01 PC

MultiViu Flex 7 Data Sheet

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Central Monitoring and Control Software for GRMS & Access Control

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

ELECTRIC CENTRAL HEATING FLOW BOILER

SECTION DETECTION AND ALARM

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Combi switchbox with integrated 3/2 way pilot valve

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

PCS0100en Persy Control Services B.V. Netherlands

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Electronic Control Devices The European Product Catalogue 2007

VOICE RECORDING SYSTEM ISDN PRI / BRI

GV-AS/EV Controller. User s Manual

NC-12 Modbus Application

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

MANUAL PC1000R

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

NGSS Data Consolidator (DC)

The house is a machine for living. Le Corbusier, Toward an Architecture, 1923

Integrated Building Management and Security System. Building Automation & Security.

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB,

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Duct Humidity Transmitter

ACCESS CONTROL SYSTEM

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

IntesisBox KNX - LON

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

Product and Application Description

GSM COMMUNICATORS CATALOGUE

KNX Panasonic Air Conditioners

Business/Home GSM Alarm System. Installation and User Manual

RRV934. Multi-controller. Synco living

IntesisBox Modbus Server SAMSUNG Air Conditioners

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

TX OPEN RS232/485 module

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

VTO6xxx. IP door stations. User manual

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Panel Meters and Controllers Modular Panel Meter Type EDM 35

WIRELESS MAGNETIC CONTACT

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Controls for fan coil units and cassettes

FT-1000/GPS-N. System of remote monitoring and control of physical

PK5500 v1.1 Installation Instructions

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Installation manual. Version

Well-Contact Suite Client Software Guidelines and precautions

Digital input modules

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Unidirectional Transmitter/ Receiver Units Introduction

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

CISA esigno Contactless Lock

Transcription:

Advanced hotel systems

AVE Since 1904, the days of my great grandfather, we have been key players in uncountable technological evolutions. However, 2008 definitely marked a turning point, the beginning of a new era. The object you are holding in your hands right now is the fruit of a journey characterised by research, innovation, investments and passion which bore DOMINA HOTEL. DOMINA HOTEL marks an important development with respect to hotel industry standards. DOMINA HOTEL represents cutting-edge research solutions and advanced design flexibly fully meeting hotel management needs ranging from small hotels to the large multinational hotel chains. An Ave tagged revolution, I am proud to say, entirely made in Italy. Welcome to Ave. Dott. Alessandro Belli President of AVE s.p.a. 2

A totally innovative solution based on invisible modules sensitive to touching the surface of the glass plate, provided with LEDs and tactile sensors. pag 4 Series characterised by design evolution and various technological features, available in a wide range of aesthetic properties. pag 8 Series conceived in the spirit of traditional and functional design, with technological solutions suitable for any environment, currently incorporating all System 44 innovations. Technical catalogue pag 10 pag 14 3

AVE patents n 205 208 209 211 212 AVE TOUCH Just one touch to step into a new era, the past fades away, simply outlived. Ave Touch comes in an awesome range of products adorning the most advanced technology with physical beauty, tactile. Ave touch obeys your orders, turning dreams into desires. Touch, listen and watch the environment you yearned for finally takes shape. AVE TOUCH With sliding cover for sockets AVE TOUCH Sign with graphic step-marker function, interchangeable and customizable with hotel logo. 4

Customizable room access client card. AVE TOUCH 3+3 With room transponder reader customizable with room number and hotel logo 5

AVE patents n 205 208 209 211 212 AVE TOUCH switches With interchangeable and customizable symbols Customizable with hotel logo AVE TOUCH signs With interchangeable and customizable symbols Customizable with hotel logo 6

AVE TOUCH Wall-lined installation A special box allows perfect wall-lined installation, leaving only the magnificent Ave Touch surface exposed. AVE TOUCH switches With regulation of sensitivity to touch Customizable with hotel logo 7

AVE patents n 196 LIFE 44 Choice and appreciation are innate traits of human beings. Ave Life 44 meets this need by combining technology with design and selected materials. An authentic treat for your eyes. LIFE 44 Extractable emergency lamp Glass VERA 44 front plate customizable with hotel logo 8

Switches Fibre optics illuminated frame Glass VERA 44 front plate Ideal combination with AVE TOUCH devices Customizable with hotel logo. The glass plate that ushers a touch of elegance into any room. Metal ZAMA 44 front plate Paintable and customizable with hotel logo. Classy frame for breathtaking environments. LIFE 44 Electronic thermostat 9

AVE patents n 196 Switches PERSONAL 44 front plate customizable with software Programmable thermostat 10

External sign PERSONAL 44 front plate Customizable with software Sockets PERSONAL 44 front plate customizable with software 11

Brevetti AVE n 196 208 209 19145 DOMUS 100 Gratifying simplicity. Combining a wide range of colours and functionalities DOMUS 100 is the perfect key to a lively and blissful system. Step-marker PERSONAL 44 front plate customizable with software Personal 44 with modern design, comes in a wide range of technological colours and with mirror effect, also available in transparent version with customizable graphic and colours. Graphic customization may also be performed by the end client by means of a software available at our website www. ave.it free of charge. Extractable emergency lamp Glass VERA 44 front plate customizable with hotel logo Switch Metal ZAMA 44 front plate Customizable with hotel logo 12

Dimmer 44 MOULDED front plate Customizable with hotel logo 44 Moulded suitable for any environment, it also incorporates all the System 44 innovations. Consumer unit Coordinated with the System 44 front platess Customizable with hotel logo VERA 44 for round box Best for restoration Customizable with hotel logo Shaver socket Glass VERA 44 front plate Customizable with hotel logo 13

14

Elettricità Evoluta dal 1904 Technical catalogue contents Stand-alone system: 125kHz technology... page 20 MIFARE technology... page 26 125kHz and MIFARE technology common products... page 32 Network system: MIFARE technology... page 38 Network and stand-alone systems common products... page 48 Codes summary: Stand-alone system... page 52 Network system... page 53 Compatibility with S45... page 54 Installation examples: Stand-alone systems... page 58 network systems... page 62 Hotel room radio components... page 66 Electrical Schematics... page 70 15

Domina Hotel, one system RELIABILITY AVE hotel system is not just about aesthetic, it is also reliability. Each room can be monitored by a central computer at the reception. However, in case of computer failure, the whole system operates as usual, losing only the remote room monitoring while awaiting repair of the failure. The system is at its best when it operates in its entirety but each device continues operating independently even in case of failure of the other components. Furthermore, the islands system, wherein each room not only operates independently but is also connected to the main network, ensures that no independent failure brings the entire hotel system to a standstill. TECHNOLOGY AVE hotel management products use the contactless Mifare and 125kHz technology. The access cards are entirely safe and clone-proof thus leaving you and your clients entirely sure that no ill-intentioned person will have an easy time in your premises. The possibility to integrate e-money systems (not provided by AVE) allows you to offer your clients an entirely new range of services, accessible through the same card which shall also serve as a payment system. AESTHETIC TOUCH: The plates are entirely customizable and configurable to suit your needs. Furthermore, they can bear, depending on the model, your hotel logo, room number and any other indication adding a personalised and unique classy touch to your hotel. Plates and devices made of various material and finishing are available. 16

Elettricità Evoluta dal 1904 for all hotel needs EFFICIENCY AND ENERGY SAVING Constant monitoring from the reception shall keep you constantly informed, allowing you to intervene promptly to curb poor quality services. Furthermore, Domina Hotel allows optimising management and keeping energy consumption under control allowing considerable saving. This implies greater customer satisfaction, a more efficient hotel and lower running costs. SCALABILITY AVE Domina Hotel systems suits all needs, both in terms of costs and performance. We have a simple and inexpensive system for small hotel operators, extremely suitable for an environment not requiring particularly sophisticated solutions. The bigger the hotel the more our system meets your ever-growing needs up to providing a complete network system for monitoring the rooms and any type of environment, even in big hotels. If you expect to expand with time, no need to worry we have the right solution for you. As a matter fact, the AVE Domina Hotel system requires just a few updates to match the growth of your business without forcing you to start from scratch, helping you preserve your investments over time. COMFORT AVE hotel devices are client-oriented, offering utmost comfort during his stay at your hotel. The thermostat, which is easy to use and intuitive, allows regulating the room temperature. The signalling system allows the client to decide when and whether to be disturbed. The room service personnel cannot ring the doorbell or open the door by mistake while the client is in the room. The remote control allows the client to operate the devices (loads) comfortably from his seat. 17

18

Elettricità Evoluta dal 1904 Hotel management stand-alone 19

Stand-alone system with 125kHz technology 53GA72-T External reader 441GA01-T 442GA01-T External readers are devices which, by means of a transponder card, allow controlling access to hotel rooms and premises. These readers are capable of independently managing their entries and exits in such a manner to be able to operate even without requiring other devices of the same hotel series. The devices may be configured for access to 4 different types of areas: ROOMS: access allowed for all enabled client cards and for the service personnel cards at given conditions (e.g. the room service personnel card operates only when the room is not occupied). SERVICE ROOMS: access allowed for service personnel cards but not for the client cards. COMMON AREAS: access allowed both for service personnel and client cards. 1 2 3 4 5 6 7 8 9 10 + SCALABLE GND A B 12V ACCESS: access allowed BUS AVE GND ARMBUS for enabled service DISTURB personnel cards. For BATT access, client cards require sufficient credit BUS consisting in a number of accesses. The device updates the card reducing the credit at PROG each access. 53GA72-T Made in Italy BATTERY 3V CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT FEM Clima 11 12 13 14 15 16 17 Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: 2 + 2 + 10 poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Blue LED light for identification in the dark Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Transponder Technology Means: ISO7816 (credit card format) Transponder: RFID 125kHz Opt64 Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with EN 60950-1:2006 harmonised standards Auxiliary relay outputs Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1) Maximum applicable load (CC): 5A @ 30Vdc Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres Maximum switching (mechanical) frequency: 18.000 cycles/hr. OVERALL DIMENSIONS 441GA01-T DISTURB 8 45 mm 7 Made in Italy 6 5 4 3 5(3)A 230V~ Court. 2 Court. 1 + - 12V BUS 6 mm B A 20 67,5 mm 55,5 mm

Stand-alone system with 125kHz technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA01-T Transponder-equipped external reader - 125kHz 3 Domus 100 series 442GA01-T Transponder-equipped external reader - 125kHz 3 Life44 series 441GA01-T 442GA01-T DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green A RS-485 + - B Green B RS-485 - Black - Supply (Common inputs) + Black + Supply 8 7 6 5 4 3 2 1 12V 1 Green Room status Input Made in Italy 5(3)A 230V~ Court. Court. BUS 2 Green Courtesy Light Input 3 e 4 Green Courtesy Light Output 6 mm B A 5 Green Common for Terminals 6, 7 and 8 6 Green Electric Lock Output 7 Green Bell Output 8 Green Guest In Output 21

Stand-alone system with 125kHz technology 53GA72-T 441GA01-T Internal reader (room) 441GA30-T 442GA30-T Internal readers are devices to be positioned inside the premises to be managed to allow 1actuation 2 3 4 of 5 room 6 7loads 8 9 and 10 services + GND A B 12V only in presence of an enabled card. Such BUS AVE GND ARMBUS DISTURB readers are capable of independently managing their inputs and outputs in such a BATT BUS manner to be able to operate even without requiring the other devices of the same hotel PROG series. Furthermore, they BATTERY are 3Vcapable of communicating 53GA72-Twith other devices such as room CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT control Made in Italyunit, transponder card external reader (for access to premises), FEM Clima environment thermostat and 11transponder 12 13 14card 15 16program- mer. 17 The readers are provided with two auxiliary inputs for detecting the state of dry contacts (voltage free contacts) and with four output relays (still for dry contact). Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): DISTURB _ 80mA Maximum absorption (@ +12Vdc): _ 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): _ 200mArms Maximum absorption (@ 12Vac): _ 250mArms OVERALL DIMENSIONS Mechanical features Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: 2 + 2 + 10 poles 12A -250V Programming connector: JFemale stereo jack d=2.5mm Blue LED light for identification in the dark Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Transponder technology Means: ISO7816 (credit card format) Transponder: RFID 125kHz Opt64 Compliance with standards 1999/5/EC Directive Made of Class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with EN 60950 1:2006 harmonised standards Auxiliary relay output Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1) Maximum applicable load (CC): 5A @ 30Vdc Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) 8 7 6 5 4 3 2 1 Maximum switching (electric) frequency: 12V 1200 cycles/hr5(3)a 230V~ Court. Court. Duration of contact (mechanical): Made in Italy 5.000.000 manoeuvres 6 mm Maximum switching (mechanical) B frequency 18.000 cycles/hr. + - BUS A 441GA30-T DISTURB DISTURB A B 45 mm BUS 12V Made in Italy 6 mm Clima FEM DISTURB 5(3)A 230V~ 1 2 3 4 5 6 7 8 - + 22 67,5 mm 55,5 mm

Stand-alone system with 125kHz technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA30-T Transponder-equipped external reader with pocket 3-125kHz Domus 100 series 442GA30-T Transponder-equipped external reader with pocket 3-125kHz Life44 series 441GA30-T + - 8 7 6 5 4 3 2 1 12V 442GA30-T 5(3)A 230V~ Court. Court. BUS Made in Italy 6 mm B A DESCRIPTION OF TERMINAL BOARD A B BUS 12V - + Made in Italy 6 mm Clima FEM DISTURB 5(3)A 230V~ 1 2 3 4 5 6 7 8 Terminal Colour Description A Green A RS-485 B Green B RS-485 - Black - Supply (Common inputs) + Black + Supply 1 Green Room Light Input 2 Green Window Contact Input 3 e 4 Green Room Light Output 5 Green Common for Terminals 6, 7 and 8 6 Green Air Conditioner Enabling Input 7 Green Load Control Output (EMF) 8 Green DISTURB Output 23 A B Made in Italy 6 mm

Stand-alone system with 125kHz technology Card programmer SCR-ALB04 Item SCR-ALB04 is a transponder card programmer (125KHz) capable of communicating with the hotel series devices. SCR-ALB04 is provided with a USB interface (compatible with 1.1 and 2.0 USB specifications), which allows directly interfacing the programmer to a monitoring PC for programming the transponder card and/or programming all 125kHz hotel management devices. In order for item SCR-ALB04 to operate, it is required to be connected to a PC provided with a special card programming software supplied as a kit. There are two types of software: the first basic one intended for the end user and a more technical one meant for installers and/or technical assistance centres. Light signals (LEDs) L1 (Red): NOT EXEC Indicates that the last command sent has not been executed correctly. L2 (Green): EXECUTED Indicates that the last command sent has been executed correctly L3 (Yellow): WAIT Indicates that the programmer is free and ready to receive new commands (blinking) Card 44339CHM-T 44339CHU-T The 125kHz cards used for hotel management are provided with a rewritable memory equivalent to 1kb. 44339CHM-T Card master The system is conceived to use a Master card in order to be able to perform any card preparation and/or programming operation. This Master card has its own unambiguous code called Hotel Code which is transferred to the reader through the same Master in the direct programming step alongside any other required data and a 24 or that it is completing the execution of a previous command (fixed light). L4 (Yellow): TX Indicates that a communication from the SCR-ALB04 programmer to the PC through interface is in progress. L5 (Yellow): RX Indicates that a communication from the PC to the SCR-ALB04 programmer through interface is in progress. Electrical features Supply voltage (DC): +5Vdc ±10% self supplied through USB port Stand-by absorption (@ +5Vdc): 50mA Maximum absorption (@ +5Vdc): 100mA USB interface compatibility: USB1.1/2.0 Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Progressive Room Code automatically increased by the reader after the first configuration. Systems divided into several zones and/or several sub-systems may be built. In this case, the system must be provided with a Master card for each of the predetermined combinations (e.g. 3 zones and 2 subsystems = 6 Master cards). NOTE: The Master card (or Master cards) serves as an identification for the system and it should be preserved with care for possible future configurations. The system code received by the Master card (alongside the sub-system code and zone code), is memorised by the reader and, during the client and/or service per- Mechanical features Container: 123 l x 30 h x 68 d mm Material: ABS (UL 94 HB) Colour: Black (Ral 9005) Degree of protection: IP40 PC interface: USB 1.1/2.0 (Type B connector) ARMBus interface: Stereo Jack 2.5mm Compatible with all 125kHz hotel system elements Operating mode The SCR-ALB04 transponder card reader/programmer may be used both as a simple device for programming transponder cards used for 125kHz hotel management (alongside a user software) and in combination with a further software (meant for technicians and/or installers), as a programmer for all modules made for hotel management. As a matter of fact, it allows updating management firmware and/or modifying configuration parameters of the various devices of the 125kHz hotel series. Furthermore, it allows monitoring traffic both on the room Bus (Sniffer) bearing all the messages and/or commands circulating in the Bus itself. sonnel card programming step, it is transferred on all the programmed cards through the reader itself. In case of failure or lack of the SCR-ALB04 programmer, all the access card programming operations may be performed by using the Master card, following procedures outlined in the reader instructions. 44339CHU-T User card User cards allow access to or use of a service. These cards are of the following types: CLIENT, ROOM SERVICE PER- SONNEL, MAINTENANCE PERSONNEL, PASSEPARTOUT, SUPER-GUEST, SUB-MASTER, MASTER COPY, ERASER.

Stand-alone system with 125kHz technology Elettricità Evoluta dal 1904 Cod. Description Modules SCR-ALB04 Transponder card programmer 125kHz - SFW-ALB04 software included SFW-ALB04 Card generation software Generates a 125kHz or MIFARE card depending on - the programmer used SCR-ALB04 SFW-ALBTECSystem configuration software for technicians and installers - EXAMPLES OF SCREENSHOTS ROOM STATUS: AVE stand-alone system software allows a constant update on which rooms are reserved and for how long. Management of the rooms allows monitoring the situation and avoiding unpleasant inefficiency for the clients as well creating client cards with expiry dates.. PERSONNEL MANAGEMENT: Personnel management allows constant monitoring of the situation and generating premises access cards allowing the hotel personnel to perform its duties in an easy manner. The room service personnel may enter the rooms for cleaning and tidying, but only when the room is not occupied by the client hence avoiding unpleasant inconveniences. The maintenance personnel shall have access to all premises without restrictions except for the rooms occupied by the clients. Cod. Description Modules 44339chm-t 125kHz Master Transponder Card - Card format: ISO7816 44339chm-t 44339chU-t 125kHz User Transponder Card - Card format: ISO7816 44339chU-t 25

Stand-alone system with MIFARE technology 53GA72-T External reader (room) 441GA01-M 442GA01-M External readers are devices which, through the use of MIFARE cards, allow controlling access to the hotel rooms and premises, and they are capable of operating even without requiring other devices of the same hotel series. MIFARE technology allows generating cards having higher security level and integrating advanced services (e-money) therein with topmost level reading performance. The devices may be configured for access to 4 different types of areas: ROOMS: access allowed for all enabled client cards and for the service personnel cards at given conditions (e.g. the room service personnel card operates only when the room is not occupied). SERVICE ROOMS: access allowed for service personnel cards but 1 2 3 4 5 6 7 8 9 10 not for the client + cards. GND A B 12V AVE BUS GND ARMBUS COMMON AREAS: access allowed both BATT for service personnel and DISTURB BUS client cards. SCALABLE ACCESS: access allowed PROGfor enabled service personnel cards. For access, CR2032 client cards require BATTERY ONLY 3V sufficient 53GA72-Tcredit consisting in a number UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT Made in Italy of accesses. The device updates the FEM Clima card reducing the credit at each access. 11 12 13 14 15 16 17 Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) for the Domus 100 series and Life44, while the AveTouch 442GA02-M code is beneath the components wire Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: 2 + 2 + 10 poles 12A - 250V Programming connector: Female Stereo Jack d=2.5mm Blue light for identification in the dark MIFARE technology Means: ISO7816 (Credit card format) Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard) Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Auxiliary relay outputs Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ1) Maximum applicable load (CC): 5A @ 30Vdc Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres Maximum switching (mechanical) frequency 18.000 cycles/hr. Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with the EN 60950-1:2006 harmonised standards OVERALL DIMENSIONS OVERALL DIMENSIONS 441GA01-T DISTURB 8 7 45 mm Made in Italy 6 5 4 3 5(3)A 230V~ Court. 2 Court. 1 + - 12V BUS 6 mm B A 26 67,5 mm 55,5 mm

Stand-alone system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA01-M External reader MIFARE 3 Domus 100 series 442GA01-M External reader MIFARE 3 Life44 series 441GA01-M 442GA02-M External reader AVETouch MIFARE 3 AVETouch series 442GA01-M 442GA02-M 442GA02-M application examples Available upon request DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green A RS-485 + - B Green B RS-485 - Black - Supply (Common inputs) 8 7 6 5 4 3 2 1 12V + Black + Supply 1 Green Room Status Input Made in Italy 5(3)A 230V~ Court. Court. BUS 2 Green Courtesy Light Input 3 e 4 Green Courtesy Light Output 6 mm B A 5 Green Common for Terminals 6, 7 and 8 6 Green Electric Light Output 7 Green Bell Enabling Output 8 Green Guest IN Output 27

Stand-alone system with MIFARE technology Internal reader (room) 53GA72-T 441GA01-T 441GA30-M + GND A B 12V AVE BUS ARMBUS 442GA30-M 1 2 3 4 5 6 7 8 9 10 DISTURB Internal BATT readers are devices to be positioned inside BUS the premises to be managed to allow actuation of room loads and services only in presence of an enabled card. Such readers PROG are capable of operating even without requiring other CR2032 BATTERY devices ONLY 3V of the same hotel 53GA72-T series. MIFARE Made in Italy technology allows generating cards FEM Clima having higher security level and integrating advanced services 11 12(e-money) 13 14 therein 15 16 17 with topmost level reading performance. Furthermore, they are capable of communicating with other devices such as room control unit, external reader, environment thermostat and MIFARE card programmer. The readers are provided with two auxiliary inputs for detecting the state of dry contacts (voltage free contacts) and with four output relays (still dry contact). Electrical features DISTURB With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms Mechanical features Container: 3 S44 modules GND UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: 2 + 2 + 10 poles 12A - 250V Programming connector: Female Stereo Jack d=2.5mm Blue light for identification in the dark Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. MIFARE technology Means: ISO7816 (Credit Card format) Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard) Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. According to ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards EMC Directive 2004/108/EC. According to the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. According to EN 60950-1:2006 harmonised standards: Auxiliary relay outputs Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1) Maximum applicable load (CC): 5A @ 30Vdc Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres Maximum switching (mechanical) frequency 18.000 cycles/hr. 8 7 Made in Italy 6 mm 6 5 4 3 5(3)A 230V~ Court. 2 Court. 1 + 12 BU B OVERALL DIMENSIONS 441GA30-T DISTURB DISTURB 45 mm A B BUS 12V Made in Italy 6 mm Clima FEM 5(3)A 230V~ 1 2 3 4 5 6 7 - + 28 67,5 mm 55,5 mm

Stand-alone system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA30-M Internal reader with pocket - MIFARE 3 Domus 100 series 442GA30-M Internal reader with pocket - MIFARE 3 3 Life44 series 441GA30-M + - 8 7 6 5 4 3 2 1 12V 442GA30-M 5(3)A 230V~ Court. Court. BUS Made in Italy 6 mm B A DESCRIPTION OF TERMINAL BOARD A B BUS 12V - + Made in Italy 6 mm Clima FEM DISTURB 5(3)A 230V~ 1 2 3 4 5 6 7 8 Terminal Colour Description A Green A RS-485 B Green B RS-485 - Black - Supply (Common inputs) + Black + Supply 1 Green Room Light Input 2 Green Window Contact Input 3 e 4 Green Room Light Output 5 Green Common for Terminals 6, 7 and 8 6 Green Air Conditioner Enabling Input 7 Green Load Control Output (EMF) 8 Green DISTURB Output 29 A B Made in Italy 6 mm

Stand-alone system with MIFARE technology Card programmer SCR-ALBM1 Item SCR-ALBM1 is a MIFARE card programmer capable of communicating with the hotel series devices. SCR-ALBM1 is provided with a USB interface (compatible with 1.1 and 2.0 USB specifications), which allows directly interfacing the programmer to a monitoring PC for programming cards and/or for monitoring and/or programming all MIFARE hotel management devices. In order for item SCR-ALBM1 to operate, it is required to be connected to a PC provided with a special card programming software supplied as a kit. There are two types of software: the first basic one intended for the end user and a more technical one meant for installers and/or technical assistance centres Light signals (LEDs) L1 (Red): NOT EXEC Indicates that the last command sent has not executed correctly. L2 (Green): EXECUTED Indicates that the last command sent has been executed correctly L3 (Yellow): WAIT Indicates that the programmer is free and ready to receive new commands (blinking) or that it is completing the execution of a Card 44339CHM-M 44339CHU-M MIFARE cards used for hotel management are provided with a rewritable memory equivalent to 1kb. 44339CHM-M Card master The system is conceived to use a Master card in order to be able to perform any card preparation and/or programming operation. This Master card has its own unambiguous code called Hotel Code which is transferred to the reader through the same Master in the direct programming step alongside any other required data and a 30 previous command (fixed light). L4 (Yellow): TX Indicates that a communication from the SCR-ALBM1 programmer to the PC through interface is in progress L5 (Yellow): RX Indicates that a communication from the PC to the SCR-ALBM1 programmer through interface is in progress. Electrical features Supply voltage (DC): +5Vdc ±10% self supplied through USB port Stand-by absorption (@ +5Vdc): 50mA Maximum absorption (@ +5Vdc): 100mA USB interface compatibility: USB1.1/2.0 Climatic conditions Temperatura ed umidità relativa di riferimento: 25 C UR 65% Range operativo di temperatura: 0 C +40 C Umidità Relativa massima: 90% @ +35 C Altitudine massima: 2000m s.l.m. Mechanical features Container: 123 l x 30 h x 68 d mm Progressive Room Code automatically increased by the reader after the first configuration. Systems divided into several zones and/or several sub-systems may be built. In this case, the system must be provided with a Master card for each of the predetermined combinations (e.g. 3 zones and 2 subsystems = 6 Master cards). NOTE: The Master card (or Master cards) serves as an identification for the system and it should be preserved with care for possible future configurations. The system code received by the Master card (alongside the sub-system code and zone code), is memorised by the reader and, during the client and/or service per- Material: ABS (UL 94 HB) Colour: Black (Ral 9005) Degree of protection: IP40 PC interface: USB 1.1/2.0 (Type B connector) ARMBus interface: Stereo Jack 2.5mm Operating mode The SCR-ALBM1 transponder card programmer may be used as a simple device for programming cards used for MIFARE hotel management, both in stand-alone and in network mode or in combination with a further software (meant for technicians and/or installers), as a programmer for all modules made for hotel management. As a matter of fact, it allows updating management firmware and/or modifying configuration parameters (resident in EEPROM) of the various devices of the MIFARE hotel series. Furthermore, it allows monitoring traffic both on the room Bus (Sniffer) bearing all the messages and/or commands circulating in the Bus itself. sonnel card programming step, it is transferred on all the programmed cards through the reader itself. In case of failure or absence of SCR-ALBM1 programmer, all the access card programming operations may be performed by using the Master card, following procedures outlined in the reader instructions. 44339CHU-M User card User cards allow access to or use of a service. These cards are of the following types: CLIENT, ROOM SERVICE PER- SONNEL, MAINTENANCE PERSONNEL, PASSEPARTOUT, SUPER-GUEST, SUB- MASTER, MASTER COPY, ERASER

Stand-alone system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules SCR-ALBM1 MIFARE card programmer - SFW-ALB04 software included SFW-ALB04 Card generation software Generates a 125kHz or MIFARE card depending - on the programmer used SCR-ALBM1 SFW-ALBTEC System configuration software for technicians and installers - Notes : - the encoder and MIFARE cards operate both in stand-alone systems and in network modes -for further details on SFW-ALB04 software see page 25 Cod. Description Moduli 44339chm-M MIFARE Master Card - Card format: ISO7816 44339chU-M MIFARE User Card - Card format: ISO7816 44339chm-M 44339chU-M 31

Thermostat Stand-alone system 125kHz and MIFARE technology common products 441GA52-T 442GA52-T The thermostat is used for detecting environment temperature and management of the thermoregulation of a hotel room or other premises in general. The thermostat is capable of independently managing its inputs and outputs. Furthermore, the thermostat is capable of communicating with the other devices such as the room control centre, external reader, internal reader and card both 125kHz and MIFARE programmer. This device is provided with two live analogic auxiliary inputs (+5Vdc) for detecting resistive values (room/window status and water temperature) and with four dry contact relay outputs. In addition, it is capable of managing both heaters and fan-coils. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 50mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 75mArms Maximum absorption (@ 12Vac): 200mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 6.5 mm (from plate wire) Degree of protection: IP40 Terminal boards: 2+2+10 poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Compatible with all System 44 elements. Temperature detection Measurement range: from 0 C to 40 C Regulation range: 30 C (from 5 C to 35 C) Reproducibility error: 0.2 C (max) Consistency: 0.3 C (max) Thermostat differential: from 0.2 C to 2,5 C to 2.5 C adjustable Display in C or F Compliance with standards IEC/EN 60730-1: automatic electrical controls for household and similar use (Part 1 - general requirements) IEC EN 60730-2-9: automatic electrical controls for household and similar use (Part 2-9 - Particular requirements for control devices sensitive to temperature) Auxiliary relay output Maximum applicable load (resistive): 2A @ 250Vac (cosϕ 1) Maximum applicable load (inductive): 2A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electrical) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres Maximum switching (mechanical) frequency: 18.000 cycles/ hr. DESCRIPTION OF DISPLAY ARMBUS ADDRESS: used only during programming step NIGHT SAVING: thermostat in night saving mode 32 OVERTEMPERATURE: overtemperature control enabled ANTIFREEZE: antifreeze control enabled BUS: system connected to Bus KEY LOCK ENABLED SUMMER: thermostat in summer mode. If blinking it means the window is open INTERMEDIATE : mild season mode. If blinking it means the window is open WINTER: winter mode. If blinking it means the window is open SAVING MODE: foperating time controlled by external clock FAN COIL: air conditioner enabled (fan symbol). The vertical bar indicates the fan-coil speed. OFF REGULATION: thermoregulation disabled manually. Antifreeze and overtemperature functions remain enabled ANTIFREEZE: antifreeze function enabled (valve open and fan speed 1) TEMPERATURE MEASUREMENT UNIT: C = degrees Celsius F = degrees Fahrenheit E = temperature out of range

8 7 6 5 4 3 2 1 12V BUS 5(3)A 230V~ Court. Court. Stand-alone Made in Italy 6 mm system 125kHz and MIFARE technology common products B A Elettricità Evoluta dal 1904 A B BUS 441GA52-T 12V Made in Italy 6 mm 5(3)A 230V~ Clima FEM 1 2 3 4 5 6 7 Cod. Description Modules 441GA52-T Saving thermostat with fan-coil or heaters regulation for stand-alone hotel management system 3 - Domus 100 series 442GA52-T Saving thermostat with fan-coil or heaters regulation for stand-alone hotel management system 3 - Life44 series DISTURB Note: 8 by connecting the 53GA91-T temperature probe to the thermostat, you obtain the automatic summer/winter switching - + 442GA52-T DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green A RS-485 A B Made in Italy 6 mm B Green B RS-485 - Black - Supply (Common inputs) BUS 12V 2(2)A 230V~ 1 2 3 4 5 6 7 8 + Black + Supply 1 Green Window Contact/Room status Input 2 Green Water Probe Input 3 e 4 Green Valve Output - + 5 Green Common for Terminals 6, 7 and 8 6 Green Fan Coil Speed 1 Output 7 Green Fan Coil Speed 2 Output 8 Green Fan Coil Speed 3 Output DESCRIPTION OF THE BUTTON PANEL Enables/disables environment thermoregulation Decreasing the temperature set-point by 0.1 C steps Increasing the temperature set-point by 0.1 C steps Regulates the fan-coil speed 33

Room Control Unit Stand-alone system 125kHz and MIFARE technology common products 53GA72-T Article 53GA72-T is a room control unit to complete the transponder stand-alone hotel range of products. 53GA72-T is capable of independently managing its outputs and inputs as well communicating with various slave devices of the same hotel series (external reader, internal reader and environment thermostat) or with a possible master device (monitoring PC connected to the Bus through the SCR-ALB04 or SCR- ALBM1 programmer. The 53GA72-T room control unit is provided with four auxiliary imputs for detecting the state of dry contacts and of four relay outputs. It is provided with an internal clock (RTC or REAL TIME CLOCK) with lithium buffer battery which allows complete management of a clock/calendar required in case one wants to use the expiry function of the cards and/or the night saving function of the thermostat. The control unit has two LEDs at the front. The LEDs indicate the following: LED green (BATT): supply status of the device. If ON with fixed light it indicates that all is OK. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 75mA Maximum absorption (@ +12Vdc): 200mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 150mArms Maximum absorption (@ 12Vac): 300mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l Mechanical features Container: 4 S44 modules (69.5 l x 89.5 h x 65 d) mm Degree of protection: IP40 Terminal boards: 10 poles + 8 poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Compliance with standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with the EN 60950-1:2006 harmonised standards OVERALL DIMENSIONS 1 2 3 4 5 6 7 8 9 10 + GND A B 12V ARMBUS AVE BUS DISTURB GND BATT BUS PROG 89,5 mm 53GA72-T 53GA72-T Made in Italy BATTERY 3V CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT FEM Clima 11 12 13 14 15 16 17 34 69,5 mm 65 mm

Stand-alone system 125kHz and MIFARE technology common products Elettricità Evoluta dal 1904 Cod. Description Modules 53GA72-T Room control unit for stand-alone systems 4 DIN GA-RTC Portable device for setting date and time - 53GA72-T TERMINAL BOARD Terminal Colour Description 1 2 3 4 5 6 7 8 9 10 + GND A B 12V ARMBUS BATT BUS AVE BUS DISTURB GND 1 Green - Supply 2 Green A RS-485 3 Green B RS-485 4 Green + Supply 5 Green AveBus + 6 Green Electric Lock Input 53GA72-T PROG 53GA72-T Made in Italy BATTERY 3V CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT FEM Clima 11 12 13 14 15 16 17 7 Green Room Light 2 Input 8 Green DISTURB Input 9 Green Air Conditioner 2 Enabling Input 10 Green Common Inputs and AVEBus (GND) 11 e 12 Green Electric Lock command Output 13 Green Room Light 2 command Output 14 Green Loads (EMF) 2 Switch Output 15 Green Air Conditioner 2 Enabling Switch Output NC contact 16 Green Air Conditioner 2 Enabling Switch Output NO contact 17 Green Common for Terminals 13, 14, 15 and 16 441GA01-T DISTURB 8 7 Made in Italy 6 5 4 3 5(3)A 230V~ Court. 2 Court. 1 + - 35 12V BUS 6 mm

36

Elettricità Evoluta dal 1904 Network hotel management 37

Network system with MIFARE technology 53GA72-T External reader 441AR01-M 442AR01-M The external readers in network are devices which, by means of MIFARE card, allow controlling access to rooms and hotel premises. External readers are capable of communicating with the room control unit, and they are driven by the latter through a monitoring central station. Such readers are provided with two auxiliary inputs for detecting the status of the dry contacts (voltage free) and four relay inputs (still dry contact). External readers are provided with a non-volatile memory for personalising some operating parameters (e.g. duration of the electric locking command). 1 2 3 4 5 6 7 8 9 10 + GND A B 12V AVE BUS ARMBUS DISTURB Electrical features With DC BATTpower supply Supply BUS voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA PROG With AC power supply CR2032 Supply voltage: BATTERY ONLY 12Vac 3V ±30% 53GA72-T Allowed supply frequency: 50 60Hz UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT Made in Italy Stand-by absorption (@ 12Vac): 200mArms FEM Clima Maximum absorption (@ 12Vac): 250mArms GND 11 12 13 14 15 16 17 Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) for the Domus 100 and Life44 series, while the AveTouch 442GA02-M code is beneath the components wire. Active area lighting: by means of high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: 2 + 2 + 10 poles 12A - 250V Programming connector: Female Stereo Jack d=2.5mm Compatible with all System 44 elements Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. MIFARE technology Means: ISO7816 (Credit card format) Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard) Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with the EN 60950-1:2006 harmonised standards. Auxiliary relay outputs Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1) Maximum applicable load (CC): 5A @ 30Vdc Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres Maximum switching (mechanical) frequency 18.000 cycles/hr. OVERALL DIMENSIONS 441GA01-T DISTURB 8 7 45 mm Made in Italy 6 5 4 3 5(3)A 230V~ Court. 2 Court. 1 + - 12V BUS 6 mm B A 38 67,5 mm 55,5 mm

Network system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA01-M External reader MIFARE 3 Domus 100 series 442GA01-M External reader MIFARE 3 Life44 series 441GA01-M 442GA02-M External reader AVETouch MIFARE 3 AVETouch series 442GA01-M 442GA02-M 442GA02-M Application examples Available upon request DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green Pole A Line RS-485 + - B Green Pole B Line RS-485 - Black Negative Supply (Common Inputs) 8 7 6 5 4 3 2 1 12V + Black Positive Supply 1 Green Input (e.g. Room status detection) 5(3)A 230V~ BUS 2 Green Input (e.g. Courtesy Light) Made in Italy 3 e 4 Green Output (e.g. Courtesy Light) 6 mm B A 5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Electric lock) 7 Green Output (e.g. Bell) 8 Green Output (e.g. Guest In ) 39

Network system with MIFARE technology Internal reader (room) 53GA72-T 441GA01-T 441AR30-M + GND A B 12V AVE BUS ARMBUS 442AR30-M 1 2 3 4 5 6 7 8 9 10 DISTURB Internal BATT readers in network are devices to be positioned BUS inside the premises to be managed to allow actuation of room loads and services only in presence of an PROG enabled card. External readers are capable of communicating BATTERY 3V with the room 53GA72-T control unit, and they are driven by CR2032 ONLY the latter through a monitoring central Made in Italy station. FEM Clima Such readers 11are 12 provided 13 14 15 with 16 two 17 auxiliary inputs for detecting the status of dry contacts (voltage free) and four relay outputs (still dry contact). Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply DISTURB Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms GND UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: 2 + 2 + 10 poles 12A - 250V Programming connector: Female Jack Stereo d=2.5mm Compatible with all System 44 elements Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. MIFARE technology Means: ISO7816 (Credit card format) Transponder: 13.56MHz MIFARE RFID (ISO 14443 type A standard) Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN 300330-2 Ver.1.3.1 (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN 301 489-1 Ver.1.6.1 (2005-09) - ETSI EN 301 489-3 Ver.1.4.1 (2002-08) - EN 50090-2-2:1996 + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with EN 60950-1:2006 harmonised standards Auxiliary relay outputs Maximum applicable load (resistive A.C.): 5A @ 250Vac (cosϕ 1) Maximum applicable load (CC): 5A @ 30Vdc Maximum applicable load (inductive A.C.): 3A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres 8 7 6 5 4 Maximum switching (mechanical) frequency 5(3)A 230V~ 18.000 cycles/hr. Made in Italy 6 mm Court. 3 2 Court. 1 + 12 BU B OVERALL DIMENSIONS 441GA30-T DISTURB DISTURB 45 mm A B BUS 12V Made in Italy 6 mm Clima FEM 5(3)A 230V~ 1 2 3 4 5 6 7 - + 40 67,5 mm 55,5 mm

Network system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA30-M Internal reader with pocket - MIFARE 3 Domus 100 series 442GA30-M Internal reader with pocket MIFARE 3 Life44 series 44GA30-M + - 8 7 6 5 4 3 2 1 12V 442GA30-M Made in Italy 5(3)A 230V~ BUS 6 mm B A CONTACT BOARD DESCRIPTION Terminal Colour Description A Green Pole A Line RS-485 A B Made in Italy 6 mm B Green Pole B Line RS-485 - Black Negative Supply (Common Inputs) BUS 5(3)A 230V~ + Black Positive Supply 1 Green Input (e.g. Room status detection) 12V 1 2 3 4 5 6 7 8 2 Green Input (e.g. Courtesy Light) 3 e 4 Green Output (e.g. Courtesy Light) - + 5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Electric lock) 7 Green Output (e.g. Bell) 8 Green Output (e.g. Guest In ) 41 A B Made in Italy 6 mm

Network system with MIFARE technology 42 Termostat 441AR52-M 442AR52-M The thermostat is used for detecting environment temperature and management of the thermoregulation of a hotel room or other premises in general. The thermostat is capable of communicating with the room control unit, and it is driven by the latter through the monitoring central station, hence allowing remote control of the temperature. This device is provided with two live analogue auxiliary inputs (+5Vdc) for detecting resistive values (room/window status and water temperature) and with four dry contact relay outputs. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 50mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 75mArms DESCRIPTION OF DISPLAY OVERTEMPERATURE: overtemperature control enabled ANTIFREEZE: antifreeze control enabled BUS: system connected to Bus KEY LOCK ENABLED Maximum absorption (@ 12Vac): 200mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 6.5 mm (from plate wire) Degree of protection: IP40 Terminal boards: 2+2+10 poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Compatible with all System 44 elements Temperature detection Measurement range: from 0 C to 40 C Regulation range: 30 C (from 5 C to 35 C) Reproducibility error: 0.2 C (max) Consistency: 0.3 C (max) Thermostat differential: from 0.2 C to 0.2 C to 2.5 C adjustable Display in C or F Compliance with standards ARMBUS ADDRESS: used only during programming step SUMMER: thermostat in summer mode. If blinking it means the window is open INTERMEDIATE : mild season mode. If blinking it means the window is open WINTER: winter mode. If blinking it means the window is open SAVING MODE: operating time controllerd by external clock IEC/EN 60730-1: automatic electrical controls for household and similar use (Part 1 - general requirements) IEC EN 60730-2-9: automatic electrical controls for household and similar use (Part 2-9 Particular requirements for control devices sensitive to temperature) Auxiliary relay output Maximum applicable load (resistive): 2A @ 250Vac (cosϕ 1) Maximum applicable load (inductive): 2A @ 250Vac (cosϕ 0.4) Duration of contact (electric): 50.000 manoeuvres maximum load) Maximum switching (electrical) frequency: 1200 cycles/hr Duration of contact (mechanical): 5.000.000 manoeuvres Maximum switching (mechanical) frequency: 18.000 cycles/hr. NIGHT SAVING: thermostat in night saving mode FAN COIL: air conditioner enabled (fan symbol). The vertical bar indicates the fancoil speed. OFF REGULATION: thermoregulation disabled manually. Antifreeze and overtemperature functions remain enabled ANTIFREEZE: antifreeze function enabled (valve open and fan speed 1) TEMPERATURE MEASURE- MENT UNIT: C = degrees Celsius F = degrees Fahrenheit E = temperature out of range

8 7 6 5 4 3 2 1 12V 5(3)A 230V~ BUS Network Made in Italy 6 mm system with MIFARE technology B A Elettricità Evoluta dal 1904 Cod. Description Modules A B 441GA52-T BUS 12V - + Made in Italy 6 mm 5(3)A 230V~ 1 2 3 4 5 6 7 441GA52-T Saving thermostat with fan-coil or heaters 3 regulation for network hotel management system - Domus 100 series 442GA52-T Saving thermostat with fan-coil or heaters 3 regulation for network hotel management system - Life44 series 8 Nota: by connecting the 53GA91-T temperature probe to the thermostat, you obtain the automatic summer/winter switching 442GA52-T DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green Pole A Line RS-485 A B Made in Italy B Green Pole B Line RS-485 6 mm - Black Negative Supply (Common Inputs) BUS 12V 2(2)A 230V~ 1 2 3 4 5 6 7 8 + Black Positive Supply 1 Green Input (e.g. Window/Room Status) 2 Green Input (e.g. Water Probe) - + 3 e 4 Green Output 1 (e.g. Valve) 5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Fan Coil Speed 1) 7 Green Output (e.g. Fan Coil Speed 2) 8 Green Output (e.g. Fan Coil Speed 3) DESCRIPTION OF THE BUTTON PANEL Enables/disables environment thermoregulation Decreasing the temperature set-point by 0.1 C steps Increasing the temperature set-point by 0.1 C steps Regulates the fan-coil speed 43

Network system with MIFARE technology Hotel Control Unit 53AR01-485 53AR02-485 Item 53AR01-485 is the room control unit for managing access (reservation/check-in/ check-out), all functions regarding thermoregulation, alarm management, flow management alongside all functions aimed at energy saving. Besides managing all room functionalities, 53AR01-485 is capable of communicating with the room devices (readers, thermostats, transmitters and receivers for actuating loads) and interfacing the room with the monitoring system server. Item 53AR02-485 is the control unit meant for managing common areas (e.g. corridors) including the functions regarding thermoregulation, alarm management and all functions aimed at saving energy. Furthermore, this control unit also manages access to zones, by means of readers to be used as common access points. In addition it allows interfacing the zones with the monitoring system server. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 150mA Maximum absorption (@ +12Vdc): 400mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 300mArms Maximum absorption (@ 12Vac): 600mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: 90% @ +35 C Maximum altitude: 2000m a.s.l. Mechanical features Container: DIN Bar 6 modules (106 l x 91h x 58,5 d) mm Degree of protection: IP40 Terminal boards: 4x 8 poles 12A - 250V Compliance with standards EMC Directive 2004/108/EC. In compliance with EN 50090-2-2:1996 harmonised standards + A1:2002 + A2:2007 LVD 2006/95/EEC. In compliance with EN 60950-1:2006 harmonised standards OVERALL DIMENSION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 POWER RUN NETBUS ARMBUS AVEBUS 91 mm 53AR01-485 Made in Italy CENTRALINA DI CONTROLLO / CENTRAL UNIT 17 18 19 20 21 22 23 24 25 26 27 28 29 30 44 106 mm 58,5 mm

Network system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 53AR01-485 Hotel control unit - room management version 53AR02-485 Hotel control unit - common area version 6 DIN 6 DIN 53AR01-485 53AR02-485 Programmatore di card Cod. Description Modules SCR-ALBM1 MIFARE Card programmer SFW-ALB04 software included SFW-ALB04 Card generation software Generates a 125kHz or MIFARE card depending on the programmer used SFW-ALBTEC system configuration software for technicians and installers SCR-ALBM1 Note: - MIFARE reader and cards operate both on stand-alone and network modes - for further details on SFW-ALB04 software see page 25 - for further information on the programmer and cards see page 30 Card Cod. Description Modules 44339chm-M MIFARE Master Card - Card format: ISO7816 44339chU-M MIFARE User Card - Card format: ISO7816 44339chm-M 44339chU-M 45

Network system with MIFARE technology Software SFW-ALB05 SFW-ALB05-CLI SFW-ALB05-FID The AVE hotel management software was conceived to guarantee instant control of the hotels where the Domina Hotel network system is installed. The number of screens to be monitored were reduced to the minimum to make the use of the software easier and quicker. In this manner, also the newly recruited personnel shall require less training and shall be capable of operating within an extremely short period of time. Domina Hotel AVE software helps you keep everything under control. GLOBAL VIEW Monitoring the rooms is extremely easy and intuitive. Each room is represented by a card and different colours instantly indicate the status of the room (occupied, vacant, not reserved), while a symbol-based system inside the card provides further detailed information. All the information needed regarding the status of the rooms is found herein without requiring visualising different screens. In case of several floors, it is possible to move from one floor to another by means of a simple menu bar on the right while the big screen displays a variety of scenes allowing to choose a view having fewer rooms with larger cards and more information or more rooms with smaller cards. Key word: Instantaneous simplicity. 46

Network system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules SFW-ALB05 Hotel management software: base module SFW-ALB05-CLI Hotel management software: 5 client licence SFW-ALB05-FID Hotel management software: hotel management systems interface module ROOM DETAIL Every room can be monitored independently down to the last detail. The screen dedicated to each room allows controlling each and every component connected to the hotel network and verifying the operating status thereof. Each operating parameter may be modified by the authorised personnel, ranging from the heating/cooling system temperature to the status of the light and rolling shutters up to controlling the opening of the door from the PC. Furthermore, each and every room may have a customized picture. Are all your hotel rooms different from each other? No need to worry! Each room may have, in its screen, the picture/drawing accurately outlining it as it is. Due to the AVE software, customization is pushed to the maximum and the facilites are entirely under control. 47

Network systems and stand-alone common components Accessories Cod. Description Modules 5349 12V transformer 4DIN 53ga91-t NTC probe for thermostats - GADS01 Silencer device for AC electric locks - 5349 uce ra 1 A clima max 2A n.b.: morsetto 5 in comune al 7 C FEM linea luce di cortesia max 3A suoneria n.b.: morsetto 5 in comune al 6 WIRING schematics 1 230V 2 3 4 5 6 24V 40VA 441GA30-T 441GA30-M 4 3 5 6 DISTURB - A B + 1 P1 2 7 DISTURB M 442GA01-M 441GA01-M 1 230V 2 442GA01-T 441GA01-T 1 230V 2 3 43 4 5 5 6 12V 40VA DISTURB 6 3 - A B + 12V 2 20VA 5 4 6 12V 20VA PC 7 GADS01 Rosso/Nero +/- Electric lock IE Red/Black Marroni o Bianchi Brown or white 48 5349 GADS01

Elettricità Evoluta dal 1904 Cod. Description Modules 442076 Casting signaling light (external) with red diffuser for lamps with E10 10x28 mm coupling 230V~ 2 3W max 441070/1 Step-marker lamp - 12-24 VDC/AC or 230Vac power 1 Supply - high efficiency white LED - Domus 100 series 442076 442070B/2 Step-marker lamp - 12-24 Vdc/ac or 230V power 2 supply - high efficiency blue LED - Life 44 series 442070W/2 Step-marker lamp - 12-24 Vdc/ac or 230V power 2 supply - high efficiency white LED - Life44 series 441070/1 442070B/2 442070W/2 441086 442086 441086 Portable extractable anti black-out lamp - Complete with 2 recharge base - Complete with rechargeable and replaceable batteries - Lamp: high efficiency white LED - Front switch for switching OFF in case of main power failure - Recharge time: 12 hours - 2 hours on battery power - 230 Vac power supply - Domus 100 series 442086 Portable extractable anti black-out lamp - Complete with 2 recharge base - Complete with rechargeable and replaceable batteries - Lamp: high efficiency white LED - Front switch for switching OFF in case of mains power failure - Recharge time: 12 hours - 2 hours on battery power- 230 Vac power supply - Life44 series Nota: in the Life44 and Domus100 wiring accessories series (in the respective catalogues) there are more than 200 functions and different standard sockets, entirely matching at technical and aesthetic level with the proposals illustrated in this catalogue. 49

50 DEVICES ARRAY External reader Internal reader Thermostat Control unit Encoder Card 125kHz stand-alone 441GA01-T (Domus100) 442GA01-T (Life44) 441GA30-T (Domus100) 442GA30-T (Life44) 441GA52-T (Domus100) 442GA52-T (Life44) 53GA72-T SCR-ALB04 44339CHM-T (MASTER) 44339CHU-T ((USER) MIFARE stand-alone 441GA01-M (Domus100) 442GA01-M (Life44) 442GA02-M (AveTouch) 441GA30-M (Domus100) 442GA30-M (Life44) SCR-ALBM1 44339CHM-M (MASTER) 44339CHU-M ((USER) MIFARE In network 441GA01-M (Domus100) 442GA01-M (Life44) 442GA02-M (AveTouch) 441GA30-M (Domus100) 442GA30-M (Life44) 441GA52-T (Domus100) 442GA52-T (Life44) 53AR01-M (Room) 53AR02-M (Common areas)

Elettricità Evoluta dal 1904 Codes summary 51

Codes summary Stand-alone system 125kHz technology Cod. Description Modules 441GA01-T Transponder-equipped external reader - 125kHz 3 Domus 100 series 442GA01-T Transponder-equipped external reader - 125kHz 3 Life44 series 441GA30-T Transponder-equipped internal reader with pocket - 125kHz 3 Domus100 series 442GA30-T Transponder-equipped internal reader with pocket - 125kHz 3 Life44 series SCR-ALB04 Transponder card programmer 125kHz - SFW-ALB04 Card generation software - Generates a 125kHz or MIFARE card depending on the programmer used SFW-ALBTEC System configuration software for technicians and installers - Stand-alone system MIFARE technology Cod. Description Modules 441GA01-M External reader - MIFARE 3 Domus100 series 442GA01-M External reader - MIFARE 3 Life44 series 442GA02-M AveTouch external reader - MIFARE 3 AveTouch series 441GA30-M Internal reader with pocket - MIFARE 3 Domus100 series 442GA30-M Internal reader with pocket - MIFARE 3 Life44 series SCR-ALBM1 MIFARE card programmer - SFW-ALB04 Card generation software - Generates a 125kHz or MIFARE card depending on the programmer used SFW-ALBTEC System configuration software for technicians and installers - Stand-alone system 125kHz technology e MIFARE Cod. Description Modules 52 441GA52-T Saving thermostat with fan-coil or heaters 3 regulation for stand-alone hotel management system - Domus 100 series 442GA52-T Saving thermostat with fan-coil or heaters 3 regulation for stand-alone hotel management system - Life44 series 53GA72-T Room control unit for stand-alone systems 4 DIN GA-RTC Portable device for setting date and time

Codes summary Elettricità Evoluta dal 1904 Network system MIFARE technology Cod. Description Modules 441ga01-M On line external MIFARE reader 3 Domus100 series 442ga01-M On line external MIFARE reader 3 Life44 series 442ga02-M On line external MIFARE reader 3 AVETouch series 441ga30-M On line internal MIFARE reader 3 Domus100 series 442ga30-M On line internal MIFARE reader in network 3 Life44 series 441ga52-t Saving thermostat with fan-coil or heaters 3 regulation for network hotel management system - Domus 100 series 442ga52-t Saving thermostat with fan-coil or heaters 3 regulation for network hotel management system - Life44 series 53AR01-485 Hotel control unit for network system - room management version 53AR02-485 Hotel control unit for network system - common area version 6 DIN 6 DIN SFW-ALB05 Hotel management software: base module - SFW-ALB05-CLI Hotel management software: 5 clients license - SFW-ALB05-FID Hotel management software: hotel management - systems interface module Network systems and stand-alone systems common codes Cod. Description Modules 5349 12V transformer - 53ga91-t NTC probe for thermostats - GADS01 Silencer device for AC electric locks 53

Compatibility with System 45 wiring accessories Due to the dual support, System 44 appliances may be installed together with System 45 plates. In case of partial restructuring or expansion, an optimal aesthetic uniformity with the already existing AVE system on which System 45 devices are mounted may be maintained, or a new hotel may be built with systems, sockets and other appliances of the Noir or Banquise (System 45) series exploiting the advanced technology of the System 44 hotel management components System44/45 System45 System44 (with Banquise aesthetic properties) System44/45 Zama plate 44a/45... Banquise plate YES plate 54

Compatibility with System 45 wiring accessories Elettricità Evoluta dal 1904 The new System 44 Domina Hotel devices are the most advanced technology-wise. Today, you may fully experience the advantages of these updated technologies, maintaining the existing electrical system and using the same System 45 plates already mounted in the entire hotel. System44/45 System45 System44/45 System44 (with Noir aesthetic properties) Zama plate 44a/45... Banquise plate YES plate 55

56

Elettricità Evoluta dal 1904 Installation examples 57

Stand-alone system Reception Card programmer Software The system is conceived to use a card encoder connected to a PC at the reception. The PC can be used to programme client check-in and check-out dates as well as actuate optional functions such as access to chargeable hotel services (swimming pool, gym, etc), through a prepaid scalable access system (for example the client pays 10 swimming pool accesses). Required functions: check-in and check-out and actuation of chargeable services. Required AVE components: FUNCTION MIFARE 125kHz Card programmer SCR-ALBM1 SCR-ALB04 Programming Software SFW-ALB04 58

Stand-alone system Elettricità Evoluta dal 1904 Suite Room Thermostat Internal reader Thermostat Room control unit Card External reader The system is conceived to use the external reader, internal reader and several thermostats for air-conditioning the rooms making up the suite. The devices are connected to each other by means of an RS485 network and a room control unit. The control unit has a clock and allows managing the cards with expiry dates. Management may be carried out in stand-alone mode both 125 khz transponder technology and MIFARE technology. Required functions: room access and actuation of air-conditioning services. Management of several thermal zones. Management of window contact and do not disturb function. Client access only during the reserved period: the card is automatically disabled at the last date of stay. Required AVE components: FUNCTION MIFARE 125kHz Room control unit 53GA72-T Data and time programmer for control unit GA-RTC (useable for all installed control units) External reader 442GA01-M (Life44) 442GA01-T (Life44) Internal reader 442GA30-M (Life44) 442GA30-T (Life44) Card 44339CHU-M / 44339CHM-M 44339CHU-T / 44339CHM-T Thermostat 442GA52-M (Life44) 442GA52-T (Life44) NTC probe 53GA91-T 230V-12V Transformer 5349 Silencer device for electric locks GADS01 Nota: all Life44 series codes may be replaced with the equivalent Domus100 codes by changing the third figure of the codes from 442... to 441... 59

Stand-alone system Complete room Thermostat Internal reader Room control unit The system is conceived to use the external reader, internal reader and thermostat for air-conditioning the room. The devices are connected to each other by means of an RS485 network and a room control unit. The control unit has a clock and allows managing the cards with expiry dates. Management may be carried out in stand-alone mode both 125 khz transponder technology and MIFARE technology. Required functions: room access and actuation of air-conditioning services. Management of window contact and do not disturb function. Client access only during the reserved period: the card is automatically disabled at the last date of stay. Required AVE components: FUNCTION MIFARE 125kHz Room control unit 53GA72-T External reader 442GA01-M (Life44) 442GA01-T (Life44) Internal reader 442GA30-M (Life44) 442GA30-T (Life44) Card 44339CHU-M / 44339CHM-M 44339CHU-T / 44339CHM-T Thermostat 442GA52-M (Life44) 442GA52-T (Life44) NTC probe 53GA91-T 230V-12V Transformer 5349 Electric lock silencer device GADS01 Card External reader 60 Nota: all Life44 series codes may be replaced with the equivalent Domus100 codes by changing the third figure of the codes from 442... to 441...

Stand-alone system Elettricità Evoluta dal 1904 Management of room access Internal reader Room control unit Card External reader The system is conceived for the sole use of external and internal readers as well as the room control unit should management of cards with expiry dates be required. The interconnection of the two readers with the RS485 network allows managing Guest in / Do not disturb signs. Required functions: room access and do not disturb sign. Possible presence of the room control unit allows managing the card with expiry dates. Required AVE components: FUNCTION MIFARE 125kHz Room control unit 53GA72-T External reader 442GA01-M (Life44) 442GA01-T (Life44) Internal reader 442GA30-M (Life44) 442GA30-T (Life44) Card 44339CHU-M / 44339CHM-M 44339CHU-T / 44339CHM-T 230V-12V Transformer 5349 Electric lock silencer device GADS01 Nota: all Life44 series codes may be replaced with the equivalent Domus100 codes by changing the third figure of the codes from 442... to 441... 61

Network system Reception Card programmer Common areas control unit Software The system is conceived for the use of one or more card encoders connected to PCs installed at the reception desk. Installed on the PCs is the hotel management software which allows, besides encoding the cards, also monitoring the status of the rooms (e.g. client or room service personnel in the room) and the common areas in real time. Use of the card with MIFARE technology allows high security conditions. Required functions: check-in and check-out from one or more stations, monitoring rooms and common areas (information regarding client/room service personnel/maintenance personnel in the room, measured temperature, window status, room to be tidied or tidied, etc), possibility of integrating e-money service (not provided by AVE) in the card. Required AVE components: FUNCTION Card programmer Hotel management software Common areas control unit (optional) MIFARE SCR-ALBM1 SFW-ALB05 53AR02-485 62

Network system Elettricità Evoluta dal 1904 Suite room Thermostat Internal reader Thermostat Room control unit Card External reader The system is conceived to use the external reader, internal reader, several thermostats for air-conditioning the rooms making up the suite and dedicated control unit. The devices are connected to each other by means of an RS485 network. The control unit gathers information regarding the premises and transmits it to the PC of the reception desk, which constantly displays the status of the environments. Required functions: room access and actuation of air-conditioning services. Management of several thermal zones. Management of window contact and do not disturb function. Client access only during the reserved period: the card is automatically disabled at the last date of stay Required AVE components: FUNCTION MIFARE Room control unit 53AR01-485 External reader 442AR01-M (Life44) Internal reader 442AR30-M (Life44) Card 44339CHU-M / 44339CHM-M Thermostat 442AR52-M (Life44) NTC probe 53GA91-T 230V-12V Transformer 5349 Electric lock silencer device GADS01 Nota: all Life44 series codes may be replaced with the equivalent Domus100 codes by changing the third figure of the codes from 442... to 441... 63

Network system Complete room Thermostat Internal reader Room control unit Card External reader The system is conceived to use the external reader, internal reader, thermostat for air-conditioning the room and dedicated room control unit. The devices are connected to each other by means of an RS485 network. The control unit gathers information regarding the premises and transmits it to the PC of the reception desk, which constantly displays the status of the environments. Required functions: room access and actuation of air-conditioning services. Management of window contact and do not disturb function. Required AVE components: FUNCTION MIFARE Room control unit 53AR01-485 External reader 442AR01-M (Life44) Internal reader 442AR30-M (Life44) Card 44339CHU-M / 44339CHM-M Thermostat 442AR52-M (Life44) NTC probe 53GA91-T 230V-12V Transformer 5349 Electric lock silencer device GADS01 64 Nota: all Life44 series codes may be replaced with the equivalent Domus100 codes by changing the third figure figures of the codes from 442... to 441...

Network system Elettricità Evoluta dal 1904 Management of common areas Thermostat Internal reader Common areas control unit Card External reader The system is conceived to use external readers placed at the entry of each common area (e.g. congress rooms, gym, swimming pool etc), and the use of a dedicated common areas control unit. The devices are connected to each other by means of an RS485 network. The control unit gathers information regarding the premises and transmits it to the PC of the reception desk, which constantly displays the status of the environments. Required functions: access to the authorised client cards and room service personnel cards. Thermoregulation is actuated from the central station and it can either be controlled according to a timetable (for example it is enabled in the morning and disabled in the evening in a swimming pool) or temporarily scheduled (for example for a congress room rented for an afternoon). Required AVE components: FUNCTION MIFARE Common areas control unit 53AR02-485 External reader (1 for each room) 442AR01-M (Life44) Internal reader (1 for each room) 442AR30-M (Life44) Card 44339CHU-M / 44339CHM-M Thermostat (1 for each room) 442AR52-M (Life44) NTC probe 53GA91-T 230V-12V Transformer (1 for each room) 5349 Electric lock silencer device GADS01 Nota: all Life44 series codes may be replaced with the equivalent Domus100 codes by changing the third figure of the codes from 442... to 441... 65

The room in a remote control R1R RT1R R1R R1R Multichannel remote control A good hotel is an environment where one can find the right blend of comfort and relax. To meet this need, AVE proposes multichannel remote controls dedicated to the room user. Such remote controls allow the user to comfortably control - from any position - all the services of the room itself (e.g. entrance light, central room light, ascent/descent of roller shutter or curtain etc). The remote controls dialogue with the following array of radio receivers: RT1R receiver for controlling roller shutters or curtains motors; R1R receiver for controlling electrical loads and allows set actuations, advantageously allowing adding new functions at any time without requiring carrying out new masonry operations. 66

Elettricità Evoluta dal 1904 Besides the hotel logo, the remote control may be customized using simple and intuitive symbols indicating the user all the controllable services in an instantaneous and practical manner. Customization example Cod. Description T9R T9R 9-button remote control for radio system. The operation depends on the set programming as indicated hereinafter. Programming possibilities - Controlling RT1R or R1R radio receivers - Connecting/disconnecting the radioed anti-burglary control unit and controlling radio receivers. Size: 41x41x10 TRS1 Desk support for T9R remote control. TRS2 Desk and wall support for T9R remote control. It can be wallmounted by means of the T9RS2M magnetic coupling. TRS2M Magnetic support for wall installation of item T9RS2 TRS1 T4R 4-channel transmitter. Allows transmitting 4 radio commands towards R1R and RT01R receivers. 230Vac power supply. Installable on DR7225 Domus44 series, VL7204 Life44 series blind plug or in a branching box. Size: 40x18x33 R1R 1-channel radio receiver. 230Vac power supply. Installable on DR7225 Domus44 series, VL7204 Life44 series blind plug or in a branching box. Contact range: 1000W/500VA to 230Vac. Size: 40x18x33 TRS2 TRS2M RT1R 1-channel radio receiver for controlling roller shutter or curtain motors. 230Vac power supply. Installable on DR7225 Domus44 series, VL7204 Life44 series blind plug or in a branching box. Output with interlocked contacts. Range: 1000W/500VA to 230Vac. Size: 40x18x33 T4R R1R RT1R 67

68

Elettricità Evoluta dal 1904 Electrical diagrams 69

Stand-alone system with 125kHz or MIFARE technology Complete room Electrical diagram From Da 230 alimentazione Vac main power supply generale 230 Vac F N DISTURB DP PSP2PN M 1 2 3 4 5 6 7 8 9 10 230V~ - A B + AVE bus I4 I3 I2 I1 - L1 5349 53GA72-T Cn1 FEM Clima 12V~ 12V~ 11 12 13 14 15 16 17 L2 FEM C clima2 -/~ +/~ +/~ -/~ 70

Stand-alone system with 125kHz or MIFARE technology Elettricità Evoluta dal 1904 M v1 v2 v3 valvola air conditioner linea room luce 1 clima valve camera light 1 line max 2A max max 3A 3A clima air max conditioner 2A max 2A n.b.: morsetto n.b.: 5 terminal comune 5 in al common 7 with 7 C FEM linea Courtesy luce di light cortesia line max 3A suoneria warning bell n.b.: morsetto 5 in n.b.: comune al 6 terminal 5 in common with 6 441GA52-T 442GA52-T 5 6 7 8 3 4 - A B + 1 2 442GA30-M 441GA30-M 442GA30-T 441GA30-T 4 3 5 6 DISTURB - A B + 1 2 7 DISTURB 442GA01-M 441GA01-M 442GA01-T 441GA01-T 3 4 - A B + 2 DISTURB 5 6 7 Rosso/Nero Red/Black +/- IE M T P1 M PC GADS01 Marroni o Bianchi Brown or white 71

Stand-alone system with 125kHz or MIFARE technology Management of room access Electrical diagram From 230 Da Vac alimentazione main power supply generale 230 Vac F N DISTURB DP PSP2PN M 1 2 3 4 5 6 7 8 9 10 230V~ - A B + AVE bus I4 I3 I2 I1 - L1 5349 53GA72-T Cn1 FEM Clima 12V~ 12V~ 11 12 13 14 15 16 17 L2 FEM C clima2 -/~ +/~ +/~ -/~ 72

Stand-alone system with 125kHz or MIFARE technology Elettricità Evoluta dal 1904 linea room luce 1 camera light line 1 max max 3A 3A air clima conditioner max max 2A 2A n.b.: morsetto n.b.: 5 terminal comune 5 in al common 7 with 7 C FEM linea Courtesy luce di light cortesia line max 3A 3A suoneria warning bell n.b.: morsetto 5 in n.b.: comune al 6 terminal 5 in common with 6 442GA30-M 441GA30-M 442GA30-T 441GA30-T 4 3 5 6 DISTURB - A B + 1 2 7 DISTURB 442GA01-M 441GA01-M 442GA01-T 441GA01-T 3 4 - A B + 2 DISTURB 5 6 7 Rosso/Nero Red/Black +/- IE P1 M PC GADS01 Marroni o Bianchi Brown or white 73

Stand-alone system with technology 125kHz or MIFARE Management of room access Electrical diagram From 230 Da Vac alimentazione main power supply generale 230 Vac F N DISTURB DP 1 2 3 4 5 PSP2PN M 6 7 8 9 10 M v1 v2 v3 valvola air clima conditioner max valve 2A max 2A 230V~ - A B + AVE bus I4 I3 I2 I1 - L1 5349 53GA72-T Cn1 5 6 7 8 3 4 12V~ 12V~ FEM Clima 441GA52-T 442GA52-T 11 12 13 14 15 16 17 - A B + 1 2 L2 FEM C clima2 M T -/~ +/~ +/~ -/~ 74

Stand-alone system with technology 125kHz or MIFARE Elettricità Evoluta dal 1904 M v1 v2 v3 valvola air linea room luce1 clima conditioner camera light line 1 max valve2a max max 3A 3A max 2A air clima conditioner max 2A max 2A n.b.: n.b.: morsetto terminal 5 comune 5 in common al 7 with 7 C FEM linea Courtesy luce di light cortesia line max 3A suoneria warning bell n.b.: morsetto 5 in comune al 6 n.b.: terminal 5 in common with 6 441GA52-T 442GA52-T 5 6 7 8 3 4 - A B + 1 2 442GA30-M 441GA30-M 442GA30-T 441GA30-T 4 3 5 6 DISTURB - A B + 1 2 7 DISTURB 442GA01-M 441GA01-M 442GA01-T 441GA01-T 3 4 - A B + 2 DISTURB 5 6 7 Rosso/Nero Red/Black +/- IE M T P1 M PC GADS01 Marroni o Bianchi Brown or white 75

AVE hotel solutions Furnishing control units matching with front plates DIN modular devices Flush-mounted boxes to be mounted on concrete or hollow walls Wiring Accessories Home automation 76 Fire extinguishing and anti-burglary systems

www.ave.it +39 030 24981