Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet



Similar documents
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

38 Series - Relay interface modules A

Thermistor motor protection

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

MasterINTERFACE 39 Series - Relay interface modules

38 Series - Relay interface modules A

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Pluggable interface relays CR-P Pcb relays

MasterINTERFACE 39 Series - Relay interface modules

Catalog. Modular DIN rail components Installation contactors

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Relés e Contatores de Estado Sólido SIRIUS

RM4TG20 three-phase network control relay RM4-T - range V

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Safety technique. Emergency stop module BO 5988 safemaster

48 SERIES Relay interface modules 10 A

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Signal converters Index

49 Series - Relay interface modules A. Features

80 Series - Modular timers 16 A. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Type: DILM32 10(24V50HZ) Article No.:

Manual motor starter MS116

RY2 miniature industrial relays

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Technical catalogue. Modular DIN rail components Installation contactors

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

mecotron Safety relay ESTOP-2 For emergency stop monitoring

40 Series - Miniature PCB/Plug-in relays A. Features

15 Series - Electronic step relay and dimmer. Features SERIE

Safety automation solutions

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

E-STOP relays, safety gate monitors

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

EMR measuring and monitoring relays

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Type: DILM50(230V50HZ,240V60HZ) Article No.:

80 Series - Modular timers 16 A. Features

STRATO LED Drivers 70W, Single output

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Quick Connect. quick - simple - efficient.

Type: DILM9 10(24VDC) Article No.:

60 Series - General purpose relays 6-10 A. Features

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Three-phase monitoring relays Product group picture

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Manual Motor Starter MS 116 up to 16 A Technical Data

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

R.C.C.B. s two-pole LEXIC

DS 600. A contact free flux gate based current measurement sensor 600A rms

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Technicaldata General

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Trip circuit supervision relay. Type RXTCS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

5SV Residual Current Protective Devices

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Waveguide Access Point WGA631. Product Guide

Signal converters Index

7 - Phaseo power supplies and transformers

Preventa Machine Safety Products

Actuator-Sensor-Interface

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Safety Manual BT50(T) Safety relay / Expansion relay

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Transcription:

Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order data Type Rated control supply voltage Order code CT-VBS.7-7 V DC SVR 43 6 R6 CT-VBS.8-4 V DC SVR 43 6 R5 Order data (Accessories) Type Description Width in mm Order code ADP. Adapter for screw mounting.5 SVR 43 9 R COV. Sealable transparent cover.5 SVR 43 5 R MAR. Marker label.5 SVR 366 7 R Application The CT-S range timers are designed for use in industrial applications. They operate over a universal range of supply voltages and a large time delay range, within compact dimensions. The easy-to-set front-face potentiometers, with direct reading scales, provide accurate time delay adjustment. Operating mode For the CT-VBS version with a -4 V AC supply voltage, the time delay is selected by connecting terminal 3 to 4. When jumpered, the time delay is from to s. If terminals 3-4 are not jumpered, the time delay is from to 4 ms. The exact time delays can be seen in the delay time diagrams.

Function diagrams B OFF-delay without auxiliary voltage (True delay on break) The DC contactor connected to the output is energized when control supply voltage is applied to terminals A-A. If control supply voltage is disconnected, the DC contactor remains energized for a short time delay. This delay time depends on the coil drop out voltage and on the wattage of the contactor coil. A-A +/- 3-4 ) +/- ) t t CDC 5 38 F5 t = OFF-delay (without jumper between terminal 3 and 4) ) t = OFF-delay (with jumper between terminal 3 and 4) ) ) only for version -4 V AC Delay time diagrams Contactor coil drop-out voltage [V] 8 6 4 8 3 W 6 7 W 4 9 W 3 4 t [ms] CDC 5 7 F5 8 6 4 8 3 W 6 7 W 4 9 W t [s] Delay time guideline values Delay time guideline values -4 V AC version without jumper 3/4-4 V AC version with jumper 3/4 Contactor coil drop-out voltage [V] CDC 5 8 F5 Contactor coil drop-out voltage [V] 8 6 4 9 W 7 W 3 W t [s] Delay time guideline values -7 V AC version CDC 5 9 F5

Connection diagrams B CT-VBS.8 A 3 4 + A 3 4 A - CDC 5 8 F5 + - A SVR 43 6 R5 A-A Supply: -4 V DC + - - Contactor coil 3-4 Jumper for setting the time delay B CT-VBS.7 A + A A - CDC 5 7 F5 + - A SVR 43 6 R6 A-A Supply: -7 V DC + - - Contactor coil 3

Technical Data Input circuits Supply voltage A-A -4 V DC A-A -7 V DC Power consumption -7 V DC max. ma -4 V DC max. 7 ma Supply voltage tolerance -5...+ % Supply voltage frequency AC/DC Version DC or 5/6 Hz AC Version 5/6 Hz Duty time % Timing circuit Time range see delay time diagrams Recovery time < 5 ms Repeat accuracy (constant parameters) ± 5 % Timing error within the supply voltage tolerance range ± % Timing error within operating temperature range. % / C Output circuits + - - Contact material AgCdO Related voltage acc. to VDE, IEC 6947- see delay time diagrams Maximum switching voltage 5 V AC, 5 V DC Rated switching current acc. to IEC 6947-5- AC- (resistive) 3 V 4 A AC-5 (inductive) 3 V 3 A DC- (resistive) 4 V 4 A DC-5 (inductive) 4 V A Maximum lifetime mechanical 3 x 6 switching cycles electrical (AC-, 3 V, 4 A). x 6 switching cycles Short circuit proof, max. fuse rating n/c A fast, operating class gl n/o A fast, operating class gl General data Enclosure width.5 mm length 78. mm depth. mm Wire size fine-strand with wire end ferrule x.75 -.5 mm (8-4 AWG) fine-strand without wire end ferrule rigid x.5-4 mm (- AWG) Weight approx. 5 g (5.3 oz) Mounting position any Degree of protection enclosure / terminals IP5 / IP Temperature range operating -...+6 C storage -4...+85 C Mounting DIN rail (IEC/EN 675) Standards Product standard IEC 68-, EN 68- EMC Directive 4/8/EC Electromagnetic compatibility IEC 6-6-, EN 6-6-4 electrostatic discharge IEC/EN 6-4- level 3 6 kv / 8 kv radiated, radio-frequency, electromagnetic field IEC/EN 6-4-3 level 3 V/m electrical fast transient / burst IEC/EN 6-4-4 level 3 kv / 5 khz Surge IEC/EN 6-4-5 level 4 kv L-L conducted disturbances, induced by radio-frequency fields IEC/EN 6-4-6 level 3 V Low Voltage Directive 6/95/EG Operational reliability acc. to IEC 68--6 4 g Mechanical resistance acc. to IEC 68--6 6 g Isolation data Rated insulation voltage between supply circuit, acc. to VDE, IEC 6947- supply up to 4 V: 3 V control circuit and output circuit supply up to 44 V: 5 V Rated impulse withstand voltage between all isolated circuits acc. to VDE, IEC 664 4 kv /.-5 µs Test voltage between all isolated circuits.5 kv, 5 Hz, min. Pollution category acc. to VDE, IEC 664, IEC 55-5 III/C Overvoltage category acc. to VDE, IEC 664, IEC 55-5 III/C Environmental testing acc. to IEC 68--3 4 h cycle time, 55 C, 93 % rel., 96 h 4

Load limit curves AC load (resistive) AC voltage [V] resistive load CDC 5 49 F6 AC current [A] DC load (resistive) DC voltage [V] resistive load CDC 5 5 F6 DC current [A] Derating factor F for inductive AC load Derating factor F..9.8.7 CDC 5 4 F6.6.5...3.4.5.6.7.8.9. cos ϕ Contact lifetime /switching cycles N Switching cycles 5 V resistive load CDC 5 48 F6 Switching current [A] V 5 Hz AC 36 cycles/h 5

Dimensional drawings Dimensions in mm 9,5 4.3,5.886 4. 78 3.7 CDC 5 88 F5 3.94 Dimensional drawings (Accessories) 6.5.56 6.5.46.5.394.453.787 6.36 7.756 ADP. - Adapter for screw mounting on panel.7,5.886 7.75 3,5.38 CDC 5 85 F5 68,5 front-to-back size 7 COV. - Sealable transparent cover 3A.787 8.35 CDC 5 86 F5 MAR. - Marker label Further documentation Document titel Document type Document number Electronic Products and Relays Technical catalogue CDC 4 Cx You can find the documentation on the internet at www.abb.com/lowvoltage R Control Products R Electronic Relays and Controls 6

Contact us STOTZ-KONTAKT GmbH P. O. Box 6 8 696 Heidelberg, Germany Phone: +49 () 6 7 - Fax: +49 () 6 7-3 5 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number CDC D4 (6/) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of AG. Copyright All rights reserved