Performance Rating of Commercial and Industrial Humidifiers

Similar documents
Performance Rating of Room Fan- Coils

Energy Recovery Ventilation Equipment

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

AHRI Standard 325 (Formerly ARI Standard 325) 1998 Standard for Ground Water-Source Heat Pumps

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

ANSI/AHRI Standard 1350 (I-P) 2014 Standard for Mechanical Performance Rating of Central Station Air-handling Unit Casings

Performance Rating of Commercial Space Heating Boilers

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

Characteristics of Evaporators

AABC Specifications for Testing and Balancing HVAC Systems

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Testing methods applicable to refrigeration components and systems

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

2007 Standard for Performance Rating of Commercial and Industrial Unitary Air- Conditioning and Heat Pump Equipment

Specifications for Refrigerants

Glossary of Heating, Ventilation and Air Conditioning Terms

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

AHRI Standard 1361 (SI) 2016 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

HEAVY DUTY STORAGE GAS

Direct steam injection humidifiers

CO MPa (abs) 20 C

Development and testing of a multi-type air conditioner without using AC inverters

HUMIDIFICATION DESIGN CHECKLIST: GETTING IT RIGHT THE FIRST TIME.

Flow Measurement Options for Pipeline and Open Channel Flow

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Heating Water by Direct Steam Injection

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

GTS PRODUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. Gas-to-Steam Humidification System

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

HUMIDIFICATION SYSTEMS: A COST AND EFFICIENCY COMPARISON

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

HVAC Simplified Approach Option

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Why and How we Use Capacity Control

Recover Heat from Boiler Blowdown Water

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

A basic introduction to steam

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Element D Services Heating, Ventilating, and Air Conditioning

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

The Different Types of Air Conditioning Equipment for IT Environments

HVAC Checklist - Long Form

High Altitude HVAC. Silvertip Integrated Engineering Consultants

HVAC Characteristics. Test Space HVAC Characteristics

THE PSYCHROMETRIC CHART AND ITS USE

HVAC Systems: Overview

Accurate Air Flow Measurement in Electronics Cooling

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

ECO-STAR II. ECO-nomical ECO-logical the ECO-STAR II. Packaged Low NOx Multi-Fuel Burner. Features. Benefits. Combustion Excellence Since 1888 ESII-1

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

NFPA31FuelOilPiping 1 Revised

FLUID FLOW Introduction General Description

Evaluate, Clean, and Tune Guidance

How To Clean Water From An Ammonia Refrigeration System

HAIL EFFECTS ON AIR-CONDITIONER PERFORMANCE

Technical Information

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Soil Suction. Total Suction

Humidification Strategies for Data Centers and Network Rooms

Basic Nameplate Information

GTS Gas-to-Steam Humidification System

THE HUMIDITY/MOISTURE HANDBOOK

Test Code: 8297 / Version 1

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Air Eliminators and Combination Air Eliminators Strainers

KNC Model 3666 Automatic Pressure Calibration System

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

Research on the Air Conditioning Water Heater System

5.2. Vaporizers - Types and Usage

Rusty Walker, Corporate Trainer Hill PHOENIX

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

"EC" Series Electric Humidifier

Cooling kw Heating kw

Energy Efficiency in Industrial HVAC Systems

AIR CONDITIONING TECHNOLOGY

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Nirvana. Cycling Refrigerated Dryers

A P P L I C A T I O N S G U I D E. Duct Application Smoke Detectors

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

2011 Standard for Performance Rating Of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Chapter 3.5: Fans and Blowers

Lesson 36 Selection Of Air Conditioning Systems

Transcription:

ANSI/AHRI Standard 640-2005 (Formerly ARI Standard 640-2005) 2005 Standard for Performance Rating of Commercial and Industrial Humidifiers

IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be nonhazardous or free from risk. Note: This standard supersedes ARI Standard 640-1996. Price $5.00 (M) $10.00 (NM) Printed in U.S.A. Copyright 2002, by Air-Conditioning, Heating, and Refrigeration Institute Registered United States Patent and Trademark Office

TABLE OF CONTENTS SECTION PAGE Section 1. Purpose... 1 Section 2. Scope... 1 Section 3. Definitions... 1 Section 4. Classifications... 3 Section 5. Test Requirements... 3 Section 6. Rating Requirements... 4 Section 7. Minimum Data Requirements for Published Ratings... 5 Section 8. Marking and Nameplate Data... 5 Section 9. Conformance Conditions... 5 TABLES Table 1. Classification of Commercial and Industrial Humidifiers... 3 Table 2. Conditions for Standard Rating Tests... 4 APPENDICES Appendix A. References - Normative... 6 Appendix B. References - Informative... 6 Appendix C. Method of Test for Commercial and Industrial Humidifiers - Normative... 7 TABLES FOR APPENDICES Table C1. Nozzle Discharge Coefficient... 7 Table C2. Temperature Correction Factor... 8

FIGURES FOR APPENDICES Figure C1. Test Apparatus for Direct Steam Injection... 10 Figure C2. Test Apparatus for Heated Tanks... 11

ANSI/AHRI STANDARD 640-2005 PERFORMANCE RATING OF COMMERCIAL AND INDUSTRIAL HUMIDIFIERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Commercial and Industrial Humidifiers: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to factory-made Commercial and Industrial Humidifiers, as defined in Section 3. 2.1.1 Energy Source. This standard applies to electric, gas, or hot water operated Commercial and Industrial Humidifiers including those that depend on steam from a central steam boiler. 2.1.2 Installation. Commercial and Industrial Humidifiers are intended for installation into an enclosed space or air system. 2.2 Exclusions. This standard does not apply to the following: 2.2.1 Central System Humidifiers as defined in the AHRI Standard 610 and to Self-Contained Humidifiers as defined in AHRI Standard 620. 2.2.2 Portable Humidifiers as defined in AHAM HU-1. Section 3. Definitions All terms in this document shall follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Commercial and Industrial Humidifier (Humidifier). A device designed to add moisture to air. 3.1.1 Atomizing Humidifiers. A type of Humidifier intended for duct applications in which water is reduced to minute particles and dispersed to air as a fine mist. 3.1.1.1 Centrifugal Type Atomizer. Utilizes a high-speed disk to sling water to its rim where it is thrown onto plates or a comb to produce a fine mist. 3.1.1.2 Nozzle Type Atomizers. Utilizes a nozzle, compressed-air, water, or air and water, to reduce water to a fine mist. a. Compressed Air. Compressed air is forced through an annular orifice at the nozzle tip creating a vortex at the tip. Water is forced through the center orifice of the nozzle where it is atomized on contact with the compressed air at the nozzle tip. b. Compressed Air and Water. Compressed air and water are combined inside the nozzle and discharged onto a resonator to produce a fine mist at the nozzle tip. c. Compressed Water. High pressure pump is used to force water through the orifice of a nozzle to produce a fine mist at the nozzle tip. 1

ANSI/AHRI STANDARD 640-2005 2 3.1.1.3 Ultrasonic Atomizer. A piezoelectric transducer immersed in a reservoir of mineral free water. The transducer converts a high-frequency electronic signal into a high-frequency mechanical oscillation. The mechanical oscillation is directed at the surface of the water, where at very high frequencies it creates a fine mist. 3.1.2 Direct Injection Steam Humidifiers. A type of Humidifier intended for duct applications in which steam, water vapor under pressure and at high temperature, is dispersed directly into the air. a. Steam Cup Type. Utilizes a cup and drain mounted beneath the duct. Steam is injected into the sides of a cup allowing most of the moisture of the steam to enter into the air while permitting the condensate to fall into the cup by gravity and into the steam trap. b. Steam Separator Type. Utilizes an enclosed distribution pipe, a separating chamber, an integral control valve, and a drain to distribute steam into the air. Steam is injected directly into the enclosed distribution pipe providing reheat to the outgoing steam passing through the distributor pipe before being released into the air. The steam then enters the separating chamber which allows dry steam to pass through the control valve and into the distributor pipe while allowing condensate to fall by gravity into the drain. The moisture of the steam is reheated while in the distributor pipe before being dispersed into the air. c. Steam Panel Type. Utilizes an integral control valve, a header with multiple distributor pipes, and a drain. The control valve regulates the amount of steam that is injected into the header, which allows dry steam to pass into the distributor pipe(s) while allowing condensate to escape through the drain. The moisture of the steam in the distributor pipe(s) is dispersed into the air. 3.1.3 Heated Tank Humidifiers. A type of Humidifier which converts tank water to steam using electricity, gas, or steam. The steam is dispersed into a duct system through dispersion manifolds. If the Humidifier is a free standing unit, the steam is dispersed directly into the air space through a fan unit. a. Electrode Type. Utilizes an electric current passing through the water to create heat energy to produce steam. b. Gas Heated Type. Utilizes natural gas or propane as the heating method to convert water to atmospheric steam. c. Infrared Type. Utilizes one or more radiant heat bulbs to create heat energy to produce steam. d. Resistance Type. Utilizes one or more electrical elements to heat the water directly to produce steam. e. Steam-to-Steam Type. Utilizes steam from a central boiler passing through a heat exchanger submersed in water to create heat energy to produce steam. f. Hot Water Type. Utilizes hot water from a central boiler passing through a heat exchanger submersed in water to create heat energy to produce steam. 3.2 Humidification Capacity. The capacity associated with a Humidifiers ability to add moisture to air expressed in lb/h [kg/h] of continuous operation. 3.3 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.3.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.3.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.4 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.4.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.5 "Shall" or "Should". "Shall" or "should" shall be interpreted as follows: 3.5.1 Shall. Where "shall" or "shall not" is used for a provision specified, the provision is mandatory if compliance with the standard is claimed. 3.5.2. Should. "Should" is used to indicate provisions which are not mandatory but which are desirable as good practice.

ANSI/AHRI STANDARD 640-2005 3.6 Supplementary Heat. Heat used to enhance evaporation when used in the recirculating system or to heat water for direct evaporation. Section 4. Classifications 4.1 Commercial and Industrial Humidifiers within the scope of this standard may be classified as shown in Table 1. Table 1. Classification of Commercial and Industrial Humidifiers Model Group Model Designation AHRI Type Centrifugal Type Atomizer ACA Group I Nozzle Type Atomizer ANA Group II Ultrasonic Atomizer Direct Steam Injection (Cup Type) Direct Steam Injection (Separator Type) Direct Steam Injection (Panel Type) Heated Tank (Electrode Type) Heated Tank (Gas Heated Type) Heated Tank (Infrared Type) Heated Tank (Resistance Type) Heated Tank (Steam-to- Steam Type) Heated Pan (Hot Water Type) AUA IDS-C IDS-S IDS-P IHT-E IHT-G IHT-I IHT-R IHT-SS IHP-HW Section 5. Test Requirements 5.1 Test Requirements. Published Ratings shall be verified by tests conducted in accordance with the test procedure described in Appendix C. 5.1.1 Equipment. Humidifiers shall be tested using all components as recommended by the manufacturer. 5.1.2 Electrical Conditions. Nameplate voltages are shown in AHRI Standard 110, Table 1. Nameplate voltages for 50 Hz systems shall include one or more of the utilization voltages shown in IEC Standard 60038. Tests shall be performed at the nameplate rated voltage and frequency unless otherwise specified in this standard. For all dual nameplate voltage equipment covered by this standard, tests shall be performed at both voltages or at the lower voltage if only a single rating is to be published. 3

ANSI/AHRI STANDARD 640-2005 Section 6. Rating Requirements 6.1 Published Ratings. Published Ratings shall include Humidification Capacity, power input, and energy input of Supplementary Heat. Humidification Capacity 1 shall be expressed in lb/h [kg/h] and stated to the nearest 0.1 lb/h [0.05 kg/h]. Power input shall be expressed in kw and stated to the nearest 0.1 kw. Where Supplementary Heat other than electric heat is used, the energy input shall be expressed in multiples of 300 Btu/h [87.9 W]. 6.2 Standard Ratings. Ratings based on data determined by the test requirements prescribed in Section 5 shall be published as Standard Ratings when conducted at the Standard Rating Conditions specified in Table 2. 6.3 Application Ratings. Ratings based on data determined by test requirements prescribed in Section 5 and conducted using Rating Conditions other than those specified in 6.2 shall be published as Application Ratings. 6.4 Tolerances. To comply with this standard, measured test results shall not be less than 95% of Published Ratings for Humidification Capacity and shall not exceed 110% of Published Ratings for power input or energy input of Supplementary Heat. Where Supplementary Heat (water) is used, the energy input from this source shall not be more than the rated power input. Table 2. Conditions for Standard Rating Tests Humidifier Type Room Conditions RH 30% Temp. 75.0 F [23.9 C] Duct Air Conditions 1 RH 30% Temp. 75.0 F [23.9 C] Supply Water Temperature 60.0 F [15.6 C] Supply Water Pressure 60.0 psi [414 kpa] Water Temp. Entering 200 F [93.3 C] Leaving 190 F [87.8 C] Steam Pressure Entering: 10 psi [69 kpa] Condensate Return Pressure: 0 psi [0 kpa] Group I Atomizing X X X X X Group II Direct Steam Injection X X Heated Tank X X X X 3 X 2 Notes: 1. Where applicable, duct airflow velocity is 500 fpm [2.5 m/s] ±2%. 2. Where applicable. 3. Applicable to hot water type only. 1 When converting Humidification Capacity from gal/day to lb/h, one gallon shall be assumed to weigh 8.34 lb. [When converting Humidification Capacity from kg/h to L/day, one liter of water shall be assumed to weigh 1 kg.] 4

ANSI/AHRI STANDARD 640-2005 Section 7. Minimum Data Requirements for Published Ratings 7.1 Minimum Data Required for Published Ratings. As a minimum, Published Ratings shall consist of the following information: a. Humidification Capacity, lb/h [kg/h] b. Power input, W [kw] c. Energy input of Supplementary Heat, Btu/h [W], where Supplementary Heat other than electric heat is used. As a minimum, Published Ratings shall include all Standard Ratings. All claims to ratings within the scope of this standard shall include the statement Rated in accordance with AHRI Standard 640. All claims to ratings outside the scope of this standard shall include the statement Outside the scope of AHRI Standard 640. Wherever Application Ratings are published or printed, they shall include a statement of the conditions at which the ratings apply. Section 8. Marking and Nameplate Data 8.1 Marking and Nameplate Data. As a minimum, the nameplate shall display the manufacturers name, model designation, and electrical characteristics. Nameplate voltages for 60 Hz systems shall include one or more of the equipment nameplate voltage ratings shown in AHRI Standard 110, Table 1. Nameplate voltages for 50 Hz systems shall include one or more of the utilization voltages shown in IEC Standard 60038. Section 9. Conformance Conditions 9.1 Conformance. While conformance with this standard is voluntary, conformance shall not be claimed or implied for products or equipment within the standard s Purpose (Section 1) or Scope (Section 2) unless such claims meet all of the requirements of the standard and all of the testing and rating requirements are measured and reported in complete compliance with the standard. Any product that has not met all the requirements of the standard shall not reference, state, or acknowledge the standard in any written, oral, or electronic communication. 5

ANSI/AHRI STANDARD 640-2005 APPENDIX A. REFERENCES - NORMATIVE A1 Listed here are all standards, handbooks and other publications essential to the formation and implementation of the standard. All references in this appendix are considered as part of the standard. A1.1 AHAM HU-1-2003, Household Humidifiers, 2003, Association of Home Appliance Manufacturers, 1111 19 th St., N.W., Suite 402, Washington, DC 20036, U.S.A. A1.2 AHRI Standard 110-2002 (formerly ARI Standard 110-2002), Air-Conditioning and Refrigerating Equipment Nameplate Voltages, 2002, Air-Conditioning Heating and Refrigeration Institute, 2111 Wilson Blvd., Suite 500, Arlington, VA 22201, U.S.A. A1.3 AHRI Standard 610-2004 (formerly ARI Standard 610-2004, Performance Rating of Central System Humidifiers, 2004, Air-Conditioning Heating and Refrigeration Institute, 2111 Wilson Blvd., Suite 500, Arlington, VA 22201, U.S.A. A1.4 AHRI Standard 620-2004 (formerly ARI Standard 620-2004, Performance Ratings of Self-Contained Humidifiers for Residential Application, 2004, Air-Conditioning Heating and Refrigeration Institute, 2111 Wilson Blvd., Suite 500, Arlington, VA 22201, U.S.A. A1.5 ANSI/ASHRAE Standard 41.1-1986 (RA 2001), Standard Method for Temperature Measurement, 2001, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.6 ANSI/ASHRAE Standard 41.2-1987 (RA 92), Standard Methods for Laboratory Airflow Measurement, 1992, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.7 ANSI/ASHRAE Standard 41.3-1989, Standard Method for Pressure Measurement, 1989, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.8 ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration Second Edition, 1991, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.9 IEC Standard 60038, IEC Standard Voltages, 2002, International Electrotechnical Commission, 3, rue de Varembe, P.O. Box 131, 1211 Geneva 20, Switzerland. APPENDIX B. REFERENCES - INFORMATIVE None. 6

ANSI/AHRI STANDARD 640-2005 APPENDIX C. METHOD OF TEST FOR COMMERCIAL AND INDUSTRIAL HUMIDIFIERS - NORMATIVE C1 Purpose. The purpose of this appendix is to specify for Commercial and Industrial Humidifiers: instrumentation; measurement and treatment apparatus; and test procedures for determining their capacity and related performance. C2 Scope. The test procedures are provided for use with Commercial and Industrial Humidifiers, and shall be used for both Standard Rating determinations and Application Rating determinations by suitable adjustment of Rating Conditions. C2.2 Exclusions. This standard is not applicable to tests conducted in the field or on the production line. C3 Instrumentation. C3.1 Airflow Rate Measuring Instruments. Airflow rate measuring instruments involved in the measurement of airflow shall be in accordance with Section 6 of ANSI/ASHRAE 41.2. C3.1.1 Nozzle Construction. Construction of nozzles shall be in accordance with Figure 6 of ANSI/ASHRAE Standard 41.2. Nozzles shall be sized for a throat velocity not less than 3,000 ft/min [15.24 m/s] nor more than 7,000 ft/min [35.56 m/s]. When nozzles are constructed in accordance with ANSI/ASHRAE Standard 41.2 and installed in accordance with C4.1, they may be used without calibration. If the throat diameter is 5.00 in [127 mm] or larger, the nozzle discharge coefficient, C, may be assumed to be 0.99. For nozzles smaller than 5.00 in [127 mm] in diameter, or where a more precise coefficient is desired, the value shown in Table C1 may be used. Reynolds Number is calculated as follows: Table C1. Nozzle Discharge Coefficients Reynolds Number, N Re Coefficient of Discharge, C 50,000 0.97 100,000 0.98 150,000 0.98 200,000 0.99 250,000 0.99 300,000 0.99 400,000 0.99 500,000 0.99 N Re = f V a D N C1 where: f = temperature correction factor V a = velocity of air at nozzle, fpm [m/s] D N = nozzle throat diameter, in [mm] 7

ANSI/AHRI STANDARD 640-2005 The temperature correction factor f shall be determined from Table C2. Table C2. Temperature Correction Factor Nozzle Air Temperature F [ C] Temperature Correction Factor, f 20 [-6.7] 10.1 [78.2] 40 [4.4] 9.30 [72.0] 60 [15.6] 8.70 [67.4] 80 [26.7] 8.10 [62.8] 100 [37.8] 7.50 [58.1] 120 [48.9] 7.10 [55.0] 140 [60.0] 6.70 [51.9] 160 [71.1] 6.30 [48.8] C3.2 Air Pressure Measuring Instruments. Pressure taps and measurement techniques shall be in accordance with ANSI/ASHRAE Standard 41.3. C3.3 Mass Flow Measuring Instruments. Mass flow measurements for steam or natural gas shall be made using a primary element, such as an orifice plate, a flow nozzle or flow tube, venturi or an averaging pitot tube, to develop a differential pressure. The accuracy of the mass flow rate measuring instruments shall permit measurements within 2.0% of the quantity measured. C3.4 Temperature Measuring Instruments. Temperature measurements shall be made in accordance with ANSI/ASHRAE Standard 41.1, having an accuracy of ± 0.10 F [± 0.05 C] to measure both wet-bulb and dry-bulb temperatures. The smallest gradation is to represent a maximum of 0.2 F [0.1 C]. C3.5 Water Quantity Measuring Instruments. Water quantity measurements shall be made with one of the following instruments having an accuracy as shown: a. Scale and weigh tank. Weight measurements shall be made with a scale having an accuracy of ± 1.0% of the unit s capacity, lb/h [kg/h]. b. Calibrated pressurized cylinder. Calibration of the cylinder shall be accurate to 1.0% of the unit s capacity, lb/h [kg/h]. C3.6 Water Pressure Measuring Instruments. Water pressure measurements shall be made in accordance with ANSI/ASHRAE 41.3 using one or more of the following instruments: a. Manometer b. Bourdon tube gage c. Aneroid pressure gage d. Calibrated pressure transducer C3.6.1 The accuracy of the water pressure measuring instruments shall permit measurements within 1.0 psi [7.0 kpa]. C3.6.2 Calibration of the Bourdon tube gage shall be with respect to a dead-weight tester or by comparison with a manometer. C3.7 Other Measurements. C3.7.1 Electrical Measurements. Electrical measurements shall be made with instruments having an accuracy of ± 1.0% of the value being observed. C3.7.2 Supplementary Heat (Water) Flow Rate Measurements. Flow rate measurements shall be made with a liquid type flow meter having an accuracy of ± 2.0% of the quantity measured. 8

ANSI/AHRI STANDARD 640-2005 C3.7.3 Supplementary Heat (Steam) Condensate Quantity Measurements. Condensate quantity shall be measured with a liquid quantity meter measuring either weight or volume having an accuracy of ± 2.0% of the quantity measured. C3.7.4 Time Measurements. Elapsed time measurements shall be made with instruments having an accuracy of ± 0.5% of the value being observed. C4 Measuring and Treatment Apparatus. C4.1 Airflow Rate Measuring Apparatus for Air Distribution Systems. Accurate and precise measurement of airflow rate is necessary to the testing of Humidifiers, which receive air from the space in which they are located and deliver it to an air distribution system. The Humidifier itself exerts no control over the airflow rate circulated through the duct system, yet the performance of several types of furnace and duct-mounted Humidifiers is substantially affected by air velocity within the system. Airflow rates shall be measured using the apparatus described below. The apparatus shall be constructed as described either in this appendix or in those publications referenced in this standard. The apparatus consists of a fan to serve as supply with variable-speed or damper to control flow rate. It includes a receiving chamber with settling means, one or more airflow measuring nozzles installed in a nozzle plate, a discharge chamber with settling means, and suitable transformation pieces for connecting the airflow rate measuring apparatus to other sections of the air distribution system. The apparatus shall be constructed in accordance with Section 5.3 of ANSI/ASHRAE 41.2, for free inlet, ducted outlet test chamber as diagramed in Figure 13, Inlet Chamber Setup for Multiple Nozzles in Chamber. C4.1.1 Setup. The requirements of the airflow rate measuring apparatus, setup for testing, proper connections and connecting ductwork, design and application of appurtenances such as straighteners, mixers, settling means, sampling devices, and variable supply or exhaust means, shall be in accordance with Section 7.2 of ANSI/ASHRAE 41.2 for inlet test chamber. C4.2 Air Treatment Apparatus. Each test facility shall be provided with the air treatment apparatus to maintain prescribed conditions of temperature, humidity, duct airflow velocity, and pressure of the air entering the test section in accordance with Section 8.2 of ANSI/ASHRAE 41.2. C4.3 Temperature Measuring Apparatus. Air temperature measurements in ducts and fluid temperature measurements within conduits shall be made in accordance with C3.4. C4.4 Water Quantity Measuring Apparatus. Means shall be provided to measure the quantity of supply and waste water used by the Humidifier under test in accordance with C3.5. C4.5 Supplemental Heat Measuring Apparatus. Means shall be provided to measure the amount of water, steam, or electricity used to supply Supplementary Heat to a Humidifier with a recirculating coil in accordance with C3.7.1, C3.7.2, or C3.7.3. C4.6 Humidifier Test Sections. Humidifier test sections shall be provided to mount the various classes of Humidifiers. The test sections shall be constructed as described below. C4.6.1 Return Air (Duct or Plenum) Test Sections. Each return air (duct or plenum) test section shall contain a diffusion baffle and airflow straightener to assure uniform air velocity and temperature within the test section. If two or more humidifier test sections are located in series, the transition and turning fittings connecting them shall be designed to minimize disturbances in the air stream. Similar transition and turning fittings shall be used to connect a humidifier test section to an airflow rate measuring apparatus, heating unit, or other apparatus. C4.7 Plenum and Duct Sections. Plenum and duct sections shall be used to connect the airflow rate measuring apparatus with other sections of the test apparatus and shall be insulated to prevent heat leakage. All joints and seams in the connecting ducts and between the connecting ducts and adjoining sections of the test apparatus shall be sealed, using tape or other sealants, so that the test apparatus is substantially air tight. Special attention shall be paid to sealing the heating unit of the heating section to prevent air leakage. 9

ANSI/AHRI STANDARD 640-2005 C4.8 Humidifier Test Room. The humidifier test room shall be any room or space in which the desired test conditions can be maintained within the test operating tolerances. C4.9 Mass Flow Measuring Apparatus. Means shall be provided to measure the quantity of supply and waste steam or gas used by the Humidifier in accordance with C3.3. The mass flow rate may be compensated for temperature and pressure by using additional temperature and pressure measuring instruments. C4.10 Test Apparatus for Direct Steam Injection Humidifiers. The apparatus consists of a source of steam; a supply side steam trap; a shut off valve; a regulator; a pressure gauge; a mass flow measuring apparatus; a receiving chamber with settling means and steam trap; and a suitable transformation piece for connecting the apparatus to the Humidifier. The apparatus shall be constructed in accordance with Figure C1. C4.11 Test Apparatus for Heated Tank Humidifiers. The apparatus consists of a source of water, steam, and where applicable-natural gas, steam, or hot water. The water supply source consists of a shut off valve and temperature gauge. Water from the water supply source is fed into a pressurized water storage tank resting on a water quantity measuring apparatus used for measuring the quantity of supply water. The water held in the pressurized water storage tank is used as the supply water to the unit under test using a suitable transformation piece consisting of a pump, pressure regulator and pressure gauge. The electrical supply to the unit under test is monitored using an electrical measuring device. In addition, the apparatus includes a second water quantity measuring apparatus for measuring waste water. The apparatus shall be constructed in accordance with Figure C2. STEAM SUPPLY 20 ft [6.1m] MIN PRESSURE REGULATOR PRESSURE GAUGE CALIBRATED ORIFICE FITTING HUMIDIFIER VALVE VALVE DRAIN TRAP PRESSURE DIFFERENTAL METER OR MANOMETER TRAP WATER DRAIN SCALE & CONTAINER TOTAL WATER OUT = WEIGHT OF WATER AT END OF TEST MINUS WEIGHT OF WATER AT START OF TEST FIGURE C1. Test Apparatus for Direct Steam Injection 10

ANSI/AHRI STANDARD 640-2005 NOTE: COMPOSITION OF THE WATER SUPPLIED IS CONDITIONED TO CONDUCTIVIY, TOTAL DISSOLVED SOLIDS, AND TEMPERATURE BEFORE START OF TEST WHERE APPLICABLE. WATER SUPPLY VALVE PRESSURE REGULATOR TIME MEASUREMENT - MEASURES TOTAL HOURS OF TEST SUPPLY ELECTRICAL MEASURING DEVICE PRESSURE GAUGE MIN. 5 ft [1.5 m] OF STEAM HOSE WHERE APPLICABLE STEAM TEMPERATURE IN LARGE SCALE & CONTAINER TOTAL WATER IN = WEIGHT OF WATER AT START OF TEST MINUS WEIGHT OF WATER AT END OF TEST HEATED TANK HUMIDIFIER AUXILLARY HEAT SOURCE-ELECTRIC, NATURAL GAS, STEAM, OR HOT WATER; WHERE APPLICABLE. PUMP OPTIONAL WATER DRAIN SCALE & CONTAINER TOTAL WATER OUT = WEIGHT OF WATER AT END OF TEST MINUS WEIGHT OF WATER AT START OF TEST FIGURE C2. Test Apparatus for Heated Tanks C5 Test Procedures. C5.1 Test Methods. The test methods described in this appendix shall be used in determining the Humidification Capacity. C5.1.1 Titles of Test Methods. The test methods described are: a. Group I (Atomizing) C5.3 b. Group II (Direct steam injection and heated tank) C5.4 C5.1.2 Applicability of Test Methods. Humidifiers shall be tested using the method described in C5.1.1 which most nearly coincides with the installation method or installation location described in the manufacturer s installation instructions. C5.2 Conditions of Test. The following conditions shall be maintained throughout the tests: C5.2.1 Air Pressure in the Air Treatment Apparatus. The air pressure in the air treatment apparatus shall be maintained as stated, except that a test tolerance of ± 0.01 in H 2 O. [± 2.5 Pa] shall be allowed. C5.2.2 Air Temperatures. The air entering the humidifier test section shall be maintained at the dry-bulb and wetbulb temperatures selected. During any test, the variation of dry-bulb temperatures shall not be more than 1.0 F [0.6 C] and the variation of wet-bulb temperatures shall be not more than 0.6 F [0.3 C]. The average of these temperatures shall be the test temperatures. These test temperatures shall be within 2.0 F [1.1 C] of the selected dry-bulb temperature and within 1.0 F [0.6 C] of the selected wet-bulb temperature. (C5.3.5.2 for temperature correction procedure.) 11

ANSI/AHRI STANDARD 640-2005 C5.2.3 Duct Airflow Velocity. The duct airflow velocity in the vicinity of the unit under test shall not exceed 500 fpm [2.5 m/s] ±2% with the Humidifier installed. C5.2.4 Electrical Supply Source. Humidifiers which require electrical energy for proper operation shall be connected to a supply of the proper voltage and frequency as measured at the electrical terminals of the Humidifier. A watt meter shall be installed in the electrical circuit when a Humidifier is connected to an electrical supply circuit. The voltage supplied to the electrical terminals of the Humidifier shall be maintained and a test tolerance of ± 1% shall be allowed. C5.2.5 Steam Supply Source. The steam supply source shall be directly connected to the Humidifier, and the steam control valve on the Humidifier shall regulate the steam flow rate. The pressure of the steam entering the steam control valve shall be maintained and a test tolerance of ± 1% shall be allowed. C5.2.6 Natural Gas Supply Source. The gas supply source shall be directly connected to the Humidifier, and the gas control valve on the Humidifier shall regulate the gas flow rate. The composition of the natural gas shall be such that its heating value is within the range of 1,000 to 1,050 Btu/ft 3 [37,260 to 39,130 kj/m 3 ]. The pressure of the gas entering the gas control valve shall be maintained within the pressure range specified by the manufacturer and a test tolerance of ± 0.1 psi [± 0.7 kpa] shall be allowed. C5.2.7 Units with Supplementary Heat (Steam). The pressure of the feed steam entering the recirculating coil shall be maintained and a test tolerance of ± 0.1 psi [± 0.7 kpa] shall be allowed. C5.2.8 Units with Supplementary Heat (Water). The pressure of the feed water entering the recirculating coil shall be maintained. (A test tolerance of ± 1.0 psi [± 7.0 kpa] shall be allowed.) The temperature of the feed water entering the recirculating coil shall be maintained and a test tolerance of ± 4.0 F [± 2.2 C] shall be allowed. C5.2.9 Water Supply Source. The water supply source shall be directly connected to the Humidifier, and the water control valve on the Humidifier shall regulate the water flow rate. The pressure of the water entering the water control valve shall be maintained and a test tolerance of ± 5.0 psi [± 34 kpa] shall be allowed. The temperature of the water entering the water control valve shall be maintained and a test tolerance of ± 2.0 F [± 1.1 C] shall be allowed. C5.2.9.1 Heating Tank Humidifiers. The composition of the water supplied to Heated Tank Humidifiers shall be such that its total dissolved solids content is within the range of 85 to 170 ppm. C5.2.9.1.1 Heating Tank Humidifiers (Electrode Type). The composition of the water supplied to electrode type Heated Tank Humidifiers shall be such that its conductivity is within the range of 300 to 315 μmhos/cm 3. C5.2.10 Direct Steam Injection. The Humidifier shall be tested using the maximum orifice size offered in the model group and fitted with a minimum 4.0 ft [1.2 m] manifold or multiples if required. C5.3 Group I (Atomizing) Test Method. This test method is used to determine the Humidification Capacity of a Humidifier which is installed in the return air duct system or the return air plenum system of an air distribution system. In either case, the Humidifier shall be installed in the humidifier test section in accordance with manufacturers written instructions. C5.3.1 Test Apparatus. The test apparatus is composed of the following components where applicable: a. Airflow rate measuring apparatus for air distribution systems (C4.1) b. Air treatment apparatus (C4.2) c. Temperature measuring apparatus (C4.3) d. Water quantity measuring apparatus (C4.4) e. Supplemental heat measuring apparatus (C4.5) f. Humidifier test sections (C4.6) g. Plenum and duct sections (C4.7) h. Humidifier test room (C4.8) C5.3.2 Air Velocity. The air velocity in the return air duct system or the return air plenum system shall be maintained at 500 fpm [2.54 m/s] or as recommended by the manufacturer based on 75.0 F [23.9 C] dry-bulb 12

ANSI/AHRI STANDARD 640-2005 temperature and 56.5 F [13.6 C] wet-bulb temperature as measured at the air measuring device section throughout the test. (A test tolerance of ± 20 fpm [± 0.10 m/s] shall be allowed.) The air velocity shall be uniform. No diverters, plates, or air directing devices, other than those supplied with the Humidifier by the manufacturer, shall be used to direct air at a higher-than-average velocity either toward or away from the Humidifier under test. C5.3.2.1 The cross-sectional area shall be the cross-sectional area of the humidifier test section measured 12.0 in [305 mm] upstream of the test unit and perpendicular to the direction of airflow. C5.3.3 Performance Test. The Humidifier to be tested shall be installed in the humidifier test room as described in C4 and the air temperatures, water temperatures, water pressures for the test shall be maintained as described in C5.1. C5.3.3.1 Water Supply Source Adjustment. If the water measuring apparatus prescribed in C4.4 does not permit supply and waste water flow rate determination while the Humidifier is connected to the water supply source, the procedure described below shall be followed. The purpose for adjusting the water flow rate is to establish the water level that is to be maintained in a Humidifier which has a float or balanced-pan valve, or the water flow rate for a Humidifier equipped with an electric water control valve (solenoid valve). C5.3.3.1.1 Water Level Determination. A Humidifier which contains a reservoir shall be installed in the test section and adjusted in accordance with the manufacturers recommendations. It shall be operated in the humidifier test section while connected to the water supply source described in C5.2.9. The water level in the reservoir shall be observed. After it has remained constant during an operating period of not less than 30 minutes, a water level line shall be marked on the reservoir. This reservoir water level shall be maintained during the capacity test. C5.3.3.1.2 Water Flow Rate Determination. A Humidifier which utilizes an electric water control valve shall be adjusted in accordance with the manufacturers recommendations. (An alternative procedure is to remove the water control valve from the Humidifier and to adjust the flow rate in accordance with the manufacturers recommendations.) The water control valve shall be opened electrically, and the water flow rate through the valve shall be determined using C4.4. The period of the preliminary test shall be not less than 30 minutes. C5.3.3.2 Connection for Capacity Test. The Humidifier under test shall be connected to the water quantity measuring apparatus described in C4.4. a. Humidifiers having a float or balanced pan valve shall be adjusted to maintain the water level determined in C5.3.3.1.1. b. Humidifiers having an electric water control valve shall be adjusted or the water-control supply source shall be controlled so that it equals the water flow rate determined in C5.3.3.1.2. C5.3.3.3 Data to Be Recorded. All data required to determine the Humidification Capacity of the unit shall be observed and recorded where applicable. C5.3.3.3.1 Air Pressures. Air pressures or a differential pressure shall be observed and recorded at the following locations: a. Static pressure drop across flow nozzle, (p v ), in H 2 O [Pa] b. Absolute pressure of air entering flow nozzle, (P n ), in Hg [kpa] c. Pressure in return air duct or return air plenum humidifier test section below atmospheric pressure, in H 2 O [kpa] C5.3.3.3.2 Air Temperatures. Dry-bulb and wet-bulb temperatures entering the Humidifier, F [ C]. a. Air entering flow nozzles b. Air entering return air duct or return air plenum c. Air entering supply air plenum or supply air duct 13

ANSI/AHRI STANDARD 640-2005 C5.3.3.3.3 Airflow Rate. Airflow rate measurement data shall be recorded in accordance with Section 9 of ANSI/ASHRAE 41.2. C5.3.3.3.4 Electric Power Input. Power input (including transformer) shall be recorded in W [kw]. Electric energy input shall be calculated from this data and expressed in Btu/h [W]. C5.3.3.3.5 Time. The time of each reading and the elapsed time between successive readings of all data, h [s]. C5.3.3.3.6 Water Temperatures and Water Pressures. a. Water temperature entering and leaving the Humidifier, F [ C] b. Water pressure during test or during preliminary water adjustment, psig [kpa gage] C5.3.3.3.7 Water Quantity. Weights or water flow rates a. Supply water to Humidifier, lb or gal [kg or L] b. Waste water, lb or gal [kg or L] c. Recirculating water (where used), lb/h or gal/h [kg/h or L/h] C5.3.3.4 Procedure. After prescribed Rating Conditions for the test have been attained, no less than five sets of readings shall be taken. The duration of the test shall not be less than thirty minutes. The test shall be continued until the weight or volume of water evaporated or injected into the Humidifier is within 5% for four successive test readings. C5.3.4 Test Results. The Humidification Capacity of the Humidifier under test shall be determined using C5.3.5.2 and shall be the average Humidification Capacity of four successive test runs complying with this section. C5.3.5 Capacity Rating Calculations. C5.3.5.1 Calculation of Velocity in the Test Section. The test unit airflow rate through the test section shall be calculated in accordance with Section 11 of ANSI/ASHRAE 41.2. In order to provide a uniform base for expressing Humidification Capacity, the total airflow rate at experimental conditions is then converted to a flow rate at Standard Rating Conditions. C5.3.5.1.1 Calculation of Specific Volume at the Nozzle. The specific volume of the air-vapor mixture at the nozzle shall be calculated as follows: v v = 1 n x 1 + W 1 or = 29.92v n + W P n (1 P b ) n v = 1 x 1 + W 1 101v or = n P (1 + W n P b ) n 29.92 460 + t x an p 460 + t + v a1 13.62 101 + p v 273 + t x an 273 + t a1 C2 14

ANSI/AHRI STANDARD 640-2005 C5.3.5.1.2 Calculation of Humidity Ratio. The humidity ratio shall be calculated as follows: W l (1,093 0.556 t a1)ws1 0.240 (t = 1,093 + 0.444 t t 6 (2.5x10 3,155 t a1)w = 6 2.5x10 + 1,035 t a1 s1 a1 a1 a1 1,005 (t 4,190 t t a1 a1 a1 ) t a1 ) C3 W n (1,093 0.556t a2 )Wsn 0.240 (t = 1,093 + 0.444 t t 6 (2.5x10 3,155 t a2 )W = 6 2.5x10 + 1,035 t a2 sn a2 a2 a2 1,005(t 4,190 t t a2 a2 a2 ) t a2 ) C4 C5.3.5.1.3 Calculation of Specific Volume at Unit. The specific volume of air entering unit shall be calculated as follows: v 1 53.352 (460 + t = 70.726 P b a1 ) (1 + 1.6078W ) 0.287 (273 + t a1) = (1 + 1.6078 W1 ) Pb 1 C5 C5.3.5.1.4 Calculation of Specific Volume at Nozzle. The specific volume of air exiting the nozzles at standard barometric pressure shall be calculated as follows: v n 53.352 (460 + t = 70.726 P 0.287 (273 + t = Pn n an an ) (1 + 1.6078 ) (1 + 1.6078 W W n n ) ) C6 C5.3.5.1.5 Calculation of Airflow Rate Through a Single Nozzle. The volume flow rate through a single nozzle shall be calculated as follows: Q 0.5 an = K 1 A n C n (p v v n ) C7 C5.3.5.1.6 Calculation of the Total Airflow Rate. The total airflow rate through multiple nozzles shall be the sum of the flow rates for each nozzle used. C5.3.5.1.7 Calculation of Specific Volume of the Air-vapor Mixture. The specific volume of the air-vapor mixture entering the unit under test shall be calculated as follows: v v1 = 1 C8 1+ W 1 15

ANSI/AHRI STANDARD 640-2005 C5.3.5.1.8 Calculation of the Airflow Rate of the Humidifier Under Test. The airflow rate for the Humidifier under test shall be calculated as follows: Q a = Q an v 1 v n C9 C5.3.5.1.9 Correct Airflow Rate to Standard Airflow. To correct the airflow rate to standard airflow the following equation shall be used: Q s Q = a C10 K (v ) 2 1 C5.3.5.1.10 Calculation of Air Velocity in Test Section. The air velocity in the test section shall be calculated as follows: V t Q = s v n A v t n C11 where: A n = Nozzle throat area, ft 2 [m 2 ] A t = Cross-sectional area of test section, ft 2 [m 2 ] C n = Nozzle discharge coefficient K 1 = 1096 [1.414] K 2 = 0.075 [1.200] P b = Barometric pressure, in Hg [kpa] P n = Nozzle throat pressure, in Hg [kpa] p v = Velocity pressure at nozzle throat or static pressure difference across nozzle, in H 2 O [Pa] Q a = Airflow rate at test unit, cfm [m 3 /s] Q an = Measured airflow rate at nozzle, cfm [m 3 /s] Q s = Measured airflow rate of standard air at test unit, scfm [standard m 3 /s] t a1 = Air entering test unit dry-bulb temperature, F [ C] t a1 = Air entering test unit wet-bulb temperature, F [ C] t a2 = Air leaving test unit dry-bulb temperature, F [ C] t a2 = Air leaving test unit wet-bulb temperature, F [ C] t an = Air entering nozzle dry-bulb temperature, F [ C] v n = Specific volume of air at dry-bulb and wet-bulb temperature conditions existing at nozzle but at standard barometric pressure, ft 3 /(lb of dry air) [m 3 /(kg of dry air)] v n = Specific volume of air at nozzle, ft 3 /(lb of moist air) [m 3 /(kg of moist air)] V t = Air velocity in test section, ft/min [m/s] v 1 = Specific volume of air at dry-bulb and wet-bulb temperature conditions existing in test section, ft 3 /lb [m 3 /kg] v 1 = Specific volume of air entering test section, ft 3 /lb [m 3 /kg] W n = Specific humidity ratio of air at nozzle, (lb moisture)/(lb of dry air), [(kg of moisture)/(kg of dry air)] W 1 = Specific humidity ratio of air entering test section, (lb moisture)/(lb of dry air), [(kg of moisture)/(kg of dry air)] 16

ANSI/AHRI STANDARD 640-2005 W s1 = Specific humidity ratio of air at saturation at wet-bulb temperature entering test section, (lb moisture)/(lb of dry air), [(kg of moisture)/(kg of dry air)] W sn = Specific humidity ratio of air at wet-bulb temperature at nozzle, (lb moisture)/(lb of dry air), [(kg of moisture)/(kg of dry air)] C5.3.5.2 Calculation of Humidification Capacity. The Humidification Capacity shall be calculated using the following equation: H m = K 1 F (H s - H t ) C12 where: FF = (t r t r)/(t t t t) = temperature correction factor C13 H m = Humidification Capacity, lb/h [kg/h] H S = Water supply rate, lb/h [kg/h] H t = Waste water rate, lb/h [kg/h] K 1 = 1.000 [0.264] t r = Return air dry-bulb temperature at Rating Conditions, F [ C] t r = Return air wet-bulb temperature at Rating Conditions, F [ C] t t = Return air dry-bulb test temperature, F [ C] t t = Return air wet-bulb test temperature, F [ C] C5.4 Group II (Direct Steam Injection and Heated Tank) Test Method. This test method is used to determine the Humidification Capacity of a Humidifier that is placed on a bench and connected in accordance with the manufacturer s written instructions. C5.4.1 Test Apparatus. The test apparatus is composed of the following components where applicable: a. Temperature measuring apparatus (C4.3) b. Water quantity measuring apparatus (C4.4) c. Supplemental heat measuring apparatus (C4.5) d. Humidifier test room (C4.8) e. Mass flow measuring apparatus (C4.9) f. Test Apparatus for Direct Steam Injection Humidifiers (C4.10) g. Test Apparatus for Heated Tank Humidifiers (C4.11) C5.4.2 Performance Test. The Humidifier to be tested shall be installed in the humidifier test room as described in C4, and the air temperatures, water temperatures, water pressures, gas pressures, steam pressure, and natural gas pressure required for the test shall be maintained as described in C5. C5.4.2.1 Connection for Capacity Test (Heated Tank). Heated Tank Humidifiers under test shall be connected to the water quantity measuring apparatus described in C4.4 for both supply and waste water. a. Humidifiers having a float or balanced pan valve shall be adjusted to maintain the water level determined in C5.3.3.1.1. b. Humidifiers having an electric water control valve shall be adjusted or the water control supply source shall be controlled so that it equals the water flow rate determined in C5.3.3.1.2. Other consistent units, such as gal/day [L/day] may be used. Dry-Bulb and Wet-Bulb Temperatures. Temperatures t t and t t are the average of the actual test temperatures entering the test section (C5.2.2) immediately before entering the Humidifier under test. Temperatures t r and t r are the rated temperatures at the same point. 17

ANSI/AHRI STANDARD 640-2005 C5.4.2.2 Connection for Capacity Test (Direct Steam Injection). Direct Steam Injection Humidifiers under test shall be connected to a mass flow measuring apparatus described in C4.9. Condensate shall be measured using the method described in C3.7.3. C5.4.2.3 Water Supply Source Adjustment. If the water measuring apparatus prescribed in C4.4 does not permit supply and waste water flow rate determination while the Humidifier is connected to the water supply source, the procedure described below shall be followed. The purpose for adjusting the water flow rate is to establish the water level that is to be maintained in a Humidifier which has a float or balanced-pan valve, or the water flow rate for a Humidifier equipped with an electric water control valve (solenoid valve). C5.4.2.3.1 Water Level Determination. A Humidifier which contains a reservoir shall be installed in the test section and adjusted in accordance with the manufacturers recommendations. It shall be operated in the humidifier test section while connected to the water supply source described in C5.2.9. The water level in the reservoir shall be observed. After it has remained constant during an operating period of not less than 30 minutes, a water level line shall be marked on the reservoir. This reservoir water level shall be maintained during the capacity test. C5.4.2.3.2 Water Flow Rate Determination. A Humidifier which utilizes an electric water control valve shall be adjusted in accordance with the manufacturers recommendations. (An alternative procedure is to remove the water control valve from the Humidifier and to adjust the flow rate in accordance with the manufacturers recommendations.) The water control valve shall be opened electrically, and the water flow rate through the valve shall be determined using C4.4. The period of the preliminary test shall be not less than 30 minutes. C5.4.2.3.3 Water Supply Adjustment for Supplemental Heat using a Recirculating Coil. The water or steam flow rate through the recirculating coil of a Humidifier using such a coil for Supplementary Heat shall be adjusted as necessary to maintain the required inlet water temperature during the test. C5.4.2.4 Steam Supply Source Adjustment. The steam flow rate through the Humidifier or recirculating coil or Humidifiers using such a coil for Supplementary Heat shall be adjusted as necessary to maintain the required inlet steam pressure during the test. C5.4.2.5 Natural Gas Supply Source Adjustment. The natural gas flow rate through the Humidifier shall be adjusted as necessary to maintain the required inlet gas pressure during the test. C5.4.3 Data to Be Recorded. All data required to determine the Humidification Capacity of the unit shall be observed and recorded where applicable. C5.4.3.1 Electric Power Input. Power input (including transformer), W [kw]. Electric energy input shall be calculated from this data and expressed in Btu/h [W]. C5.4.3.2 Natural Gas Supply Input. Natural gas consumption, Btu/ft 3 [kj/m 3 ]. C5.4.3.3 Time. The time of each reading and the elapsed time between successive readings of all data, h [s]. C5.4.3.4 Water and Steam Temperatures and Pressures. a. Water temperature entering and leaving the Humidifier, F [ C] b. Water temperature entering and leaving the recirculating coil (recirculating coil on Humidifiers using such a coil for Supplementary Heat), F [ C] c. Water pressure during test or during preliminary water adjustment,psig [kpa gage] d. Steam pressure entering unit (where used), psig [kpa gage] 18

ANSI/AHRI STANDARD 640-2005 C5.4.3.5 Water Quantity. Weights or water flow rates a. Supply water to Humidifier, lb or gal [kg or L] b. Waste water, lb or gal [kg or L] c. Recirculating water (where used), lb/h, or gal/hr [kg/h or L/h] C5.4.3.6 Condensate Quantity. Condensate leaving the Humidifier, lb or gal [kg or L]. C5.4.4 Procedure. After prescribed Rating Conditions for the test have been attained, no less than five sets of readings shall be taken. The duration of the test shall not be less than thirty minutes. The test shall be continued until the weight or volume of water evaporated or injected into the Humidifier is within 5% for four successive test readings. C5.4.5 Test Results. The Humidification Capacity of the Humidifier under test shall be determined using C5.4.6.1 and shall be the average Humidification Capacity of four successive test runs complying with this section. C5.4.6 Capacity Rating Calculations. C5.4.6.1 Calculation of Humidification Capacity. The Humidification Capacity, except for Direct Injection Steam Humidifiers, shall be calculated using the following equation: H m = K 1 (H s - H t ) C14 where: H m = Humidification Capacity, lb/h [kg/h] H S = Water supply rate, lb/h [kg/h] H t = Waste water rate, lb/h [kg/h] K 1 = 1.000 [0.264] C5.4.6.1.1 Direct Injection Steam Humidifiers. Humidification Capacity, for Direct Injection Steam Humidifiers, shall be calculated using the following equation: H m = m s m c C15 where: m c = mass flow of condensate, lb/h [kg/h] m s = mass flow measurement for steam, lb/h [kg/ h] Other consistent units, such as gal/day [L/day] may be used. 19