GE OEC 9800 Surgical C- Arm System

Similar documents
HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

AXIOM Artis U The little big one for universal angiography and cardiology applications

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Performance testing for Precision 500D Classical R/F System

GE Healthcare. OEC 9900 Elite. Premium Digital Mobile Imaging System.

X-ray Imaging Systems

Digital Dental X-ray. Midmark Animal Health Products

C-Arm 101. Everything you ever need to know! Guide to C-Arms

MEDICAL IMAGING. 90/30 Remote Controlled RF System

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

X-ray Imaging Systems

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

How To Use Bodescan For 3D Imaging Of The Human Body

Cardius. XPO Series. Cardius 3 XPO

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

MRC High Resolution. MR-compatible digital HD video camera. User manual

Data. microcat +SPECT

Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound)

D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Diffractive Optical Elements (DOE) for FLEXPOINT Laser Modules

D/N VARI-FOCAL IR CAMERA

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Required RS Training Info

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

BB-18 Black Body High Vacuum System Technical Description

How an electronic shutter works in a CMOS camera. First, let s review how shutters work in film cameras.

Digital panoramic X-ray for practical diagnostics

SMART Board interactive flat panel with appliance Model 8055ie-SMP

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Electronic Control Devices The European Product Catalogue 2007

Motion Activated Camera User Manual

DENTAL Cone beam 3D X-RAY SYSTEM with

The Convenient and Compact CR System for Veterinary Practices

UV-NIR LASER BEAM PROFILER

Tube Control Measurement, Sorting Modular System for Glass Tube

X-Mind. Instinct for perfection

Robot Perception Continued

Rodenstock Photo Optics

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

SERIE NEMESIS 9000 TM

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Kleuren camera PAL : 512 (H) X 582 ( V) NTSC : 512 (H) X 492 (V) CS/ C Mount (Mount adaptor option)

ADVANCED DIRECT IMAGING. by ALTIX

Series. Laser air Leddura Lexinus Mensa. 70 inch. Smart innovation! When function matters.

A single device, a plethora of treatments.

DR Retrofit Kit 1417 WL Configuration Integrated PACS

The Trade-off between Image Resolution and Field of View: the Influence of Lens Selection

Description. Dimensions. Features. precision works better

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Synthetic Sensing: Proximity / Distance Sensors

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Waveform Monitor Audio & Loudness Logging

Chapter I Model801, Model802 Functions and Features

Pictorial User s Guide

ENGLISH. Planmeca ProMax 3D Mid

Frequency Converter Fv

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

The convenient and compact CR system for veterinary practices

White paper. In the best of light The challenges of minimum illumination

Sympodium Interactive Pen Display

Three Channel Optical Incremental Encoder Modules Technical Data

Appendix - Controllers 179

Dome Camera with IR Night Vision

Luminos Agile A RADical new way in fluoroscopy Answers for Life

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

SL Series AC and DC Electronic Loads

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

pb tec solutions GmbH, Max-Planck-Str. 11, Alzenau (Germany) Tel.: Fax:

E190Q Lecture 5 Autonomous Robot Navigation

Talon and Talon SR User Manual

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Planetary Imaging Today. Bryan Cogdell, Celestron LLC

DXC-990 DXC-990P. 3-CCD Colour Video Camera

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

Parameter values for the HDTV standards for production and international programme exchange

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!

Machine Tool Inspection & Analyzer solutions

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

LEICA TRI-ELMAR-M mm f/4 ASPH. 1

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

The professional for your diagnostics.

Transcription:

9 I.I. System With Super- C Option Shown GE OEC 9800 Surgical C- Arm System The GE OEC 9800 C- Arm System is a versatile unit designed with multiple x- ray applications in mind. The 9800 can be used in Pain Management, Orthopedics, Vascular and Neurovascular environments. An upgrade from the 9600, the 9800 now offers 1K x 1K image resolution, better image quality with lower x- ray dosage due to new imaging software, and touch screen operation, on top of the already excellent penetration power, and excellent image quality. Includes the following: Software Options: GSP General Surgical Package ESP Expanded Surgical Package (optional 8 Frames Per Sec) Vascular Package ( 8/15 Frames Per Sec) Nero Vascular Package (30 Frames Per Sec) Cardiac Package (30 Frames Per Sec)

Super- C: (optional): Adds Extra 7 Of Depth To Arc Of C- Arm Allows 148 Degrees Of Orbital Rotation Not Available With 12 Image Intensifier Generator: 60 khz High frequency 15 kw full- wave Up to 120 kvp Up to 75 ma for radiographic film exposures Continuous fluoro boost mode up to 20mA Pulsed fluoro mode Pulsed fluorography mode up to 40 ma(optional) Full power from outlet: - 50 Hz or 60 Hz - 100V- 15A to 240V- 10A Patented energy buffer design X- Ray Tube: Rotating anode X- ray tube Focal spots: 0.3 mm and 0.6 mm Anode heat capacity: 300,000 HU Anode cooling rate: 60,000 HU/min Housing heat capacity: 1,600,000 HU Anode diameter: 3.1 in Anode angle: 10 X- ray tube cooling fan (Vascular, Neurovascular & Cardiac units) Collimator: Iris collimation with dual opposing semitransparent leaf shutters allow elliptical, round and rectangular collimation Minimum beam size < 5 X 5 cm2 Iris and shutters are continuously variable All functions remotely controlled from the C- Arm control panel

Fluoroscopy Mode: kvp range: 40 120 kvp ma range: 0.2 10 ma normal mode ma range: 0.2 20 ma continuous fluoro boost mode Auto and manual modes Continuous, one- shot or pulsed operation ABS varies ma, kvp and camera gain User specific ABS tables Pulsed Fluoroscopy Mode: kvp range: 40-120 kvp ma range: 0.2-5.0 ma Pulse rate: 1, 2, 4, or 8 pulses per second Pulse width: 30 or 50 milliseconds Computer controlled ABS, ma, kvp and camera gain Pulsed Fluorography Mode (optional): kvp range: 40-120 kvp ma range: 0.2-40.0 ma Pulse rate: 1, 2, 4, or 8 pulses per second Pulse width: 30 or 50 milliseconds Computer controlled ABS, ma, kvp and camera gain Digital Spot Mode (optional): Standard with the Expanded Surgical Platform (ESP) Enhanced digital fluorographic oneshot with 12 ma boost Automatically terminates exposure and stores enhanced image to storage archival disk Radiographic Mode: or 0.6 mm Focal spot automatically selected 0.3 mm - mas range: 1-100 mas 0.6 mm - mas range: 110-300 mas kvp range: 50-120 kvp

9 in Image Intensifier: Tri- mode 9 in. / 6 in. / 4.5 in. image intensifier Minimum central resolution (at the monitor): - 9 in.: 1.4 lp/mm - 6 in.: 2.0 lp/mm - 4.5 in.: 2.4 lp/mm DQE: 65% (typical) 12 in Image Intensifier (optional): Tri- mode 12 in. / 9 in. / 6 in. image intensifier Minimum central resolution (at the monitor): - 12 in.: 1.0 lp/mm - 9 in.: 1.3 lp/mm - 6 in.: 1.6 lp/mm DQE: 65% (typical) Video Camera: High resolution CCD camera Full frame capture 360 motorized rotation On- screen orientation indicator (realtime feedback without fluoro) Left- right image reversal Top- bottom image reversal Negative mode Video signal: Standard RS 170A 60 Hz, 525 lines Aspect ratio: 4:3 Computer controlled features: - Gain - Blanking - Camera iris Video Monitors: Dual 16 in square, black etched, anti- glare, anti- static 525 lines/frame - 512 pixels Ambient room light sensor Multi- LED X- ray ON indicator Remote window/level controls

Hardcopy Options: Thermal printer External DICOM box Laser aiming device (optional) C- Arm Dimensions: Height: 68 / 86 in (1734 / 2191 mm) Width: 33 in (838 mm) Length: 78 in (1994 mm) Weight: 720 lbs. Workstation Dimensions: Height: 64 in (1632 mm) Width: 27 in (692 mm) Depth: 27 in (692