DKG-114-J MANUAL AND REMOTE START UNIT WITH J1939 INTERFACE

Similar documents
FIREDEX Conventional Fire Panels

GST301. (Single Protection Zone) Operation Manual

is then retained absolutely without interruption.

Drayton Digistat +2RF/+3RF

Product and functional description

SX460. Generator Automatic Voltage Regulator Operation Manual

Energy Division

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

GENERATORS CONTROL PANEL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Manual Ranging MultiMeter

Stove Guard Kit User Manual

ATL Fuel Level Sender Probes

PUSH BUTTON START INSTALLATION MANUAL

Installation & User Manual Radio Remote rev1.0.3

Solar Controller / Battery Charger User s Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Signature and ISX CM870 Electronics

DALI RC BASIC SO. Control unit Operating instructions

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

ACS-30-EU-EMDR-10-MOD

COMPALARM AP GENERAL MAIN FEATURES

INSTALLATION & SERVICE MANUAL. Display Panel

*.ppt 11/2/ :48 PM 1

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Duct Humidity Transmitter

Power Generation. Power Control PCL System Generator Set Control

WIRELESS MAGNETIC CONTACT

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

User Manual for CH-PFC76810

I STAR COMPUTER CO., LTD

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

WD-AMX Water Detection Controllers

SYSTEM 4C. C R H Electronics Design

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

LOXONE 12 Channel Amplifier

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Inwall 4 Input / 4 Output Module

Digital Pressure Measuring Instrument MDR480

Antec TruePower User's Manual

NC-12 Modbus Application

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Manual for Fire Suppression & Methane Detection System

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

T7560A,B,C Digital Wall Module

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ZC-24DO CANopen I/O Module: 24 Digital Outputs

HMI display Installation Guide

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

SOLAR POWER - THE NEW WAY TO RV!

COLOR VIDEO DOOR PHONE CDV-71BE/D

Digital input modules

Model 201 Wiegand Touchpad Reader Installation Guide

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

AXIS T81B22 DC 30W Midspan

Model EC5111 Speed Controller Isochronous / Droop

PRO PLM Installation Instructions

500r+ Installation and User Guide

User s Manual Before using the inverter, you need to read and save the safety instructions.

BODY ELECTRICAL TOYOTA ELECTRICAL WIRING DIAGRAM WORKBOOK. ASSIGNMENT Version 1.8 WORKSHEETS.

AUTODIALLER / QUICKDIALLER - SA132

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Repeaters and Mimics Data Sheet

12 Volt 30 Amp Digital Solar Charge Controller

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

FT-100 Fire Training Fog Machine User Manual English

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Preset Counter signo 721

SYSTEM 45. C R H Electronics Design

Installation Manual for D1110 DigiCom2

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

Installation and User Guide

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Modular I/O System Analog and Digital Interface Modules

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Transcription:

Tel: +90-216-466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr DKG-114-J MANUAL AND REMOTE START UNIT WITH J1939 INTERFACE FEATURES Manual and remote starting and stopping ECU control via J1939 CANBUS ECU alarm display via J1939 CANBUS Zero power consumption at rest Replaces the CIU unit in Volvo engines Various engine brands and models supported Automatic shutdown on fault condition Built in alarms and warnings LED displays Jumper selected operating modes Survives cranking dropouts Sealed front panel Plug-in connection system for easy replacement Low cost, Small dimensions, Standard panel dimensions, (72x72mm)

TABLE OF CONTENTS Section 1. DESCRIPTION 2. INSTALLATION 2.1. Introduction to the Control Panel 2.2. Mounting the Unit 2.3. Wiring the Unit 2.4. Inputs and outputs 3. DISPLAYS 4. ALARMS 5. MODES OF OPERATION 6. J1939 ENGINE MONITORING AND CONTROL PORT 7. JUMPER SELECTOR SWITCHES 8. MAINTENANCE 9. TROUBLESHOOTING 10. DECLARATION OF CONFORMITY 11. TECHNICAL SPECIFICATIONS 12. CONNECTION DIAGRAM - 2 -

1. DESCRIPTION The DKG-114-J is a low cost engine control unit designed to start and stop electronic engines both manually and remotely. The manual control is made using the pushbuttons on the front panel. The remote control is made via the REMOTE START input signal. The unit connects to ECU controlled electronic engines through its standard J1939 CANBUS port providing engine control and protection without extra senders. It has the ability of engine starting and stopping with J1939 messages. The ECU alarms are displayed with appropriate leds. The message starting feature allows removal of the CIU unit in message started engines. In the STOP position, the DC supply is removed from the module, thus zero power consumption is achieved. The unit powers up when the RUN button is pressed or BAT + is applied to the REMOTE START input. This will also energize the fuel solenoid relay. The engine is automatically started 3 times until operation. Once the engine is running, it monitors the ECU alarms. If a fault condition occurs, the unit shuts down the engine automatically and indicates the failure source with the corresponding red led lamp. If the STOP button is pressed or the REMOTE START signal removed, the engine will be stopped. The unit offers jumper selectable operating parameters, which lets it to be used with various engine brands and models. The unit fits into a standard 72x72mm panel meter opening and offers a very cost effective and space saving solution for the electronic engine control. Thanks to the completely sealed structure, IP65 protection degree is achieved from the front panel. The unit works on both 12 Volt and 24 Volt gensets. 2. INSTALLATION 2.1 Introduction to the Control Panel The control panel is designed to provide user friendliness for both the installer and the user. Jumper selectors allow the complete control over the generating set or engine. 2.2 Mounting the Unit The unit is designed for panel mounting. The user should not be able to access parts of the unit other than the front panel. Mount the unit on a flat, vertical surface. The unit fits into a standard panel meter opening of 68x68 millimeters. Before mounting, remove the mounting brackets and connectors from the unit, then pass the unit through the mounting opening. The unit will be maintained in its position by the mounting brackets. Please use a twisted pair of cable or a dedicated 120 ohms coaxial cable for the CANBUS connection. The shield of the cable should be grounded at one end only. The charge alternator connection terminal provides also the excitation current, thus it is not necessary to use an external charge lamp. - 3 -

2.3 Wiring the Unit 2.4 Inputs and Outputs WARNING: THE UNIT IS NOT FUSED. Use external fuse for: BAT(+). Install the fuse as close as possible to the unit. The fuse rating should be 6 Amps. Term Function Technical data Description 1 Digital communication J1939 + port 2 J1939 - Connect the J1939 port of an electronic engine to these terminals. The 120 ohm terminating resistors are inside the unit. Please do not connect external resistors. If external resistors are already fitted, the terminating resistor can be cancelled with jumper control. Use a twisted cable pair or coaxial cable for best results. 3 GROUND 0VDC The negative (-) terminal of the DC Supply shall be connected to this terminal. Be careful for the polarization, in case of polarity error the unit will not operate. The unit operates on both 12V and 24V battery systems. 4 START RELAY Output 10A/28VDC Engine crank output. Relay automatically turns off when the engine speed reaches 300rpm. 5 REMOTE START Digital input A battery positive connection to this terminal will initiate a REMOTE START cycle. If the signal is disconnected, this will stop the engine after cooldown cycle. If STOP key is pressed during Cooldown, the engine will stop immediately. 6 EMERGENCY STOP Digital input If battery negative is applied to this input, the engine will stop immediately. 7 LAMP TEST Digital input If battery negative is applied to this input, all displays will turn on for checking. 8 BATTERY POSITIVE +12 or 24VDC The positive (+) terminal of the DC Supply shall be connected to this terminal. Be careful for the polarization, in case of polarity error the unit will not operate. The unit may operate on both 12V and 24V battery systems. 9 FUEL RELAY Output 10A/28VDC The unit activates this output before starting the engine and deactivates it to stop it. It is internally connected to terminal 11 for supplying the charge alternator s excitation current. 10 ALARM RELAY Output 10A/28VDC This relay is activated when a fault condition has occurred. 11 CHARGE Input and output Connect the charge alternator s D+ terminal to this terminal. This terminal will supply the excitation current and measure the voltage of the charge alternator. If the CANBUS is disabled by jumper selection, this terminal will act as ENGINE RUNNING signal input. - 4 -

3. DISPLAYS POWER: (green) it flashes when the unit is powered on. It turns steadily on when the engine is running. REMOTE START: (yellow) it turns on when the remote start signal is present. 4. ALARMS Alarms indicate an abnormal situation in the engine and cause: - The related alarm led to turn on steadily, - The engine to stop immediately, - The Alarm relay output to operate, - The related alarm source led to flash. Alarm LEDs will stay on and disable the operation of the engine even if the alarm source is removed. In order to reset the alarm conditions press the STOP button. COMMUNICATION LOST: Set if no information has been received during 3 seconds from the ECU of the electronic engine. This fault condition is only controlled when the fuel is on. ECU FAIL: Set when an engine fault code is received from the ECU of the electronic engine. The alarm source will also be indicated by flashing OIL, TEMP and SPEED leds wherever applicable. OIL: Flashes if a fault code concerning the oil pressure is received from the ECU of the electronic engine. TEMP: Flashes if a fault code concerning the coolant temperature is received from the ECU of the electronic engine. SPEED: Flashes if a fault code concerning the engine rpm is received from the ECU of the electronic engine. 5. MODES OF OPERATION The modes of operation are selected by pressing the front panel keys. MANUAL START / REMOTE START: Manual start mode is entered by pressing the front panel RUN key, remote start mode is entered by applying the battery positive voltage to the REMOTE START terminal. In both modes, the engine will be started 3 times. When the engine runs, the crank relay will be immediately deactivated. MANUAL STOP / REMOTE STOP: Manual stop mode is entered by pressing the front panel STOP key, remote stop mode is entered by disconnecting the battery positive voltage from the REMOTE START terminal. When engine stop is requested, a cooldown cycle of 30 seconds will be entered. At the end of the cooldown cycle the engine will stop. If immediate stop is requested, the STOP key should be pressed again. If no alarm exists, the unit disconnects from the power source in order to reach zero power consumption. If alarm exists, the unit will not power off until the front panel STOP key is pressed. - 5 -

6. J1939 ENGINE MONITORING AND CONTROL PORT The unit offers a special J1939 port in order to communicate with electronic engines controlled by an ECU (electronic control unit). The J1939 port consists of 2 terminals which are J1939+ and J1939-. The connection between the unit and the engine should be made with either a twisted cable pair or a coaxial cable. If a coaxial cable is used, the external conductor should be grounded at one end only. The 120 ohms termination resistor is included inside the unit with jumper control. Please do not connect external resistor. If the terminating resistor is already installed, the internal 120 ohms resistor may be cancelled by removing JP1. The J1939 port is activated by inserting the jumper JP2. If the engine is a message started type like Volvo models insert also jumper JP3. Please contact DATAKOM for the current list of supported engines. When the fuel output is active, if no information is received from the ECU during last 3 seconds, then the unit will give a COMMUNICATION LOST alarm and stop the engine. This feature prevents uncontrolled engine operation. Any fault condition received from the ECU of the electronic engine will also cause the engine to be stopped. If the fault condition is caused by the oil pressure sensor, coolant temperature sensor or engine speed sensor the related alarm led will also flash. 7. JUMPER SELECTOR SWITCHES FUNCTION JUMPERS SETTINGS Terminating resistor JP1 CANBUS enable JP2 Message start JP3 ON: 120 ohms Terminating resistor is inserted OFF: No terminating resistor ON: CANBUS communication enabled OFF: CANBUS communication disabled ON: Message started engine (some Volvo types) OFF: Crank relay started engine (most common engine type) 8. MAINTENANCE DO NOT OPEN THE UNIT There are NO serviceable parts inside the unit. Wipe the unit, if necessary with a soft damp cloth. Do not use chemical agents - 6 -

9. TROUBLESHOOTING When the RUN key is pressed the unit gives COMMUNICATION LOST alarm: - Check that CANBUS J1939 cables are connected properly to the ECU. - Check the terminating resistor necessity and set jumper JP1 accordingly. - Check polarity reversal of the cables. - Connect the ground terminal of the unit to the ground terminal of the ECU. - Use coaxial cable, ground at one end. - Check sanity of the ECU. When the engine is running the unit gives COMMUNICATION LOST alarm: - Excessive EMI noise: - Connect the ground terminal of the unit to the ground terminal of the ECU. - Use coaxial cable, ground at one end. - Check the terminating resistor necessity and set jumper JP1 accordingly. 10. DECLARATION OF CONFORMITY The unit conforms to the EU directives -2006/95/EC (low voltage) -2004/108/EC (electro-magnetic compatibility) Norms of reference: EN 61010 (safety requirements) EN 61326 (EMC requirements) The CE mark indicates that this product complies with the European requirements for safety, health environmental and customer protection. - 7 -

11. TECHNICAL SPECIFICATIONS DC Supply Range: 9.0 to 30.0 V-DC Cranking dropouts: survives 0 V for 100ms. Typical Standby Current: 0 ma-dc in OFF mode. Maximum Operating Current: 250 ma-dc (Relay outputs open) DC Relay Outputs: 10 A / 28V-DC Charge excitation current: 150mA-min @ 10 to 30V-DC Digital inputs: input voltage 0-30 VDC. Internally connected to battery positive via 4700 ohm resistor. Number of starts: 3 Start duration: 8 sec. Wait between starts: 10 sec. Cooldown: 30 sec. Alarm duration: 1 minute. Protection delay: 8 sec. Operating temp.: -20 C (-4 F) to 70 C (158 F). Storage temp.: -40 C (-40 F) to 80 C (176 F). Humidity: max 95% (non-condensing) Dimensions: 72 x 72 x 43 mm (WxHxD) Panel Cut-out Dimensions: 69 x 69 mm minimum. Measurement category: CAT II Air category: Pollution degree II Weight: 180 g (approx.) Case Material: High Temp. ABS (UL94-V0, 100 C) IP Protection: front panel:ip65, rear: IP30 Case material: High temperature, self extinguishing ABS (UL94-V0, 100 C) 12. CONNECTION DIAGRAM - 8 -