Air Conditioners. Technical Data RKS-J

Similar documents
Air Conditioners Technical Data

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

Air Conditioners Technical Data

Cooling kw Heating kw

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Air Conditioners Technical Data

Daikin Altherma hybrid heat pump. The natural combination

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

emura Form. redefined.

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

The natural ombination

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

HP switch LP switch Discharge thermo Comp. Surface thermo

Daikin Altherma. hybrid heat pump. The natural combination

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Air conditioners Heating & Cooling

The natural ombination

Inverter technology. bulletin

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

SiUS Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Appendix - Controllers 179

DESIGN & TECHNICAL MANUAL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

DESIGN & TECHNICAL MANUAL

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Europe Inverter Single 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A)

FTQ. Daikin Inverter Ducted Heat Pump

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

MAC-120HE-01 Air-Cooled Chiller

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

ECOCIAT. Domestic hot water heat recovery unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

DAikin Altherma low temperature heat pump. end user leaflet

SERVICE MANUAL INDOOR UNIT

Split System Cooling Product Data

york air-conditioning products Residential & VRF News 2015

SERVICE MANUAL MXZ-2A20NA MXZ-2A20NA - MXZ-3A30NA MXZ-3A30NA - MXZ-4A36NA OUTDOOR UNIT. No. OB444. Models HFC. Inverter-controlled multi system type

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

PANASONIC TROUBLE SHOOTING GUIDE

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

Split units TH with hermetic compressors

Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps.

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

How To Measure Temperature On A Thermostat

Split System Air Conditioners SkyAir Inverter

NEW 3-PIPE ECOi MF2 SERIES

SERVICE MANUAL INDOOR UNIT

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

FTXS. Wall Mount Heat Pump or Cooling Only

Operating Instructions Split System Air Conditioner

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

FHQ. Ceiling Suspended Heat Pump or Cooling Only

USER S MANUAL HSC-24A

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

SERVICE MANUAL MU-A09WA MU-A12WA MU-A12WA- 1 OUTDOOR UNIT. No. OB449. Wireless type Models HFC. Revision : A SPLIT-TYPE AIR CONDITIONERS

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

SERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

Technical service manual 2009

How To Power A Car With A Fan And A Fan (Power)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Failure code manual. content

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Refrigeration Compressed Air Dryer Buran Ultrapulse

LOBOY 16 AIR CONDITIONERS

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

MDT5N25 & MTD5N40 SERVICE PARTS

Multi Air Conditioner SVC MANUAL(Exploded View)

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

Condensing unit type EPSILON-ECHOS LE Technical information manual

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Unico Inverter. Unique and efficient.

Transcription:

Air Conditioners Technical Data P a i r a p p l i c a t i o n E E D E N 1 1-1 0 0 RKS-J

Air Conditioners Technical Data P a i r a p p l i c a t i o n E E D E N 1 1-1 0 0 RKS-J

TABLE OF CONTENTS RKS-J 1 Features............................................................. 2 2 Specifications....................................................... 3 Nominal Capacity And Nominal Input................................ 3 Technical Specifications............................................. 7 Electrical Specifications.............................................. 8 3 Electrical data....................................................... 9 Electrical Data........................................................ 9 4 Capacity tables.................................................... 12 Cooling Capacity Tables............................................ 12 5 Dimensional drawings............................................ 15 Dimensional Drawings.............................................. 15 6 Centre of gravity................................................... 16 Centre of Gravity.................................................... 16 7 Piping diagrams................................................... 18 Piping Diagrams.................................................... 18 8 Wiring diagrams................................................... 20 Wiring Diagrams - Single Phase................................... 20 9 Sound data......................................................... 22 Sound Pressure Spectrum - Cooling................................ 22 10 Operation range................................................... 23 Operation Range.................................................... 23 Split - Sky Air Outdoor Unit 1

k i ni l p- rp ao t o J i dr - l ti pua 1 Features c S U S K PS OR Energy efficient units: up to class A energy labels Outdoor units for pair application Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency 2 Split - Sky Air Outdoor Unit

2 Specifications 2-1 Nominal Capacity And Nominal Input FCQ35C8VEB / RKS35J2V1B FCQ50C8VEB / RKS50J2V1B Cooling capacity Min. kw 1.4 (3) 0.9 (3) Btu/h 4,780 (3) 3,070 (3) kcal/h 1,200 (3) 770 (3) Nom. kw 3.40 (3) 5.0 (3) Btu/h 11,600 (3) 17,100 (3) kcal/h 2,920 (3) 4,300 (3) Max. kw 3.7 (3) 5.6 (3) Btu/h 12,600 (3) 19,100 (3) kcal/h 3,180 (3) 4,820 (3) Power input Cooling Nom. kw 0.950 1.410 EER 3.58 3.55 Annual energy consumption kwh 475 705 Energy label Cooling A Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain OD mm 32 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: return air temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent refrigerant piping length 5m (horizontal) (4) Nominal heating capacities are based on: indoor temperature: 20ºCDB, outdoor temperature: 7ºCDB, 6ºCWB, equivalent refrigerant piping: 5m, level difference: 0m. (5) All data mentioned is preliminary information FTXS20J2V1B / RKS20J2V1B FTXS25J2V1B / RKS25J2V1B FTXS35J2V1B / RKS35J2V1B 2-1 Nominal Capacity And Nominal Input Cooling capacity Min. kw 1.3 1.4 1.7 Btu/h 4,400 4,800 5,800 kcal/h 1,120 1,200 1,460 Nom. kw 2.0 (3) 2.5 (3) 3.5 (3) 4.2 (3) 5.0 (3) Btu/h 6,800 (3) 8,500 (3) 11,900 (3) 14,300 (3) 17,100 (3) kcal/h 1,720 (3) 2,150 (3) 3,010 (3) 3,010 (3) 4,300 (3) Max. kw 2.8 3.2 4.0 5.0 5.3 Btu/h 9,600 10,900 13,600 17,100 18,100 kcal/h 2,410 2,750 3,440 4,300 4,560 Power input Cooling Min. kw 0.320 0.350 0.440 Nom. kw 0.450 0.535 0.860 1.210 1.460 Max. kw 0.810 0.810 1.190 2.330 1.810 EER 4.44 4.67 4.07 3.47 3.42 Annual energy consumption kwh 225 268 430 605 730 Energy label Cooling A Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain OD mm 18.0 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m FTXS42J2V1B / RKS42J2V1B FTXS50J2V1B / RKS50J2V1B Split - Sky Air Outdoor Unit 3

2 Specifications 2-1 Nominal Capacity And Nominal Input FBQ35C7VEB / RKS35J2V1B FBQ50C7VEB / RKS50J2V1B Cooling capacity Min. kw 1.4 0.9 Btu/h 4,800 3,100 kcal/h 12,600 770 Nom. kw 3.40 (3) 5.0 (3) Btu/h 11,600 (3) 17,100 (3) kcal/h 2,920 (3) 4,300 (3) Max. kw 3.7 5.6 Btu/h 12,600 19,100 kcal/h 3,180 4,820 Power input Cooling Min. kw - 4.50 Nom. kw 1.05 1.83 Max. kw - 2.02 EER 3.24 2.73 Annual energy consumption kwh 530 825 Energy label Cooling A B Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 2-1 Nominal Capacity And Nominal Input FHQ35BVV1B / RKS35J2V1B FHQ50BVV1B / RKS50J2V1B Cooling capacity Min. kw 1.4 1.7 Btu/h 4,800 5,800 kcal/h 1,200 1,460 Nom. kw 3.4 (3) 5.0 (3) Btu/h 11,600 (3) 17,100 (3) kcal/h 2,920 (3) 4,300 (3) Max. kw 3.7 5.6 Btu/h 12,600 19,100 kcal/h 3,180 4,820 Power input Cooling Min. kw - 0.44 Nom. kw 1.05 1.83 Max. kw - 2.02 EER 3.24 2.73 Annual energy consumption kwh 525 915 Energy label Cooling A D Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 4 Split - Sky Air Outdoor Unit

2 Specifications 2-1 Nominal Capacity And Nominal Input FDKS50C7VMB / RKS50J2V1B Cooling capacity Min. kw 1.7 (3) Btu/h 5,800 (3) kcal/h 1,460 (3) Nom. kw 5.0 (3) Btu/h 17,100 (3) kcal/h 4,300 (3) Max. kw 5.3 (3) Btu/h 18,100 (3) kcal/h 4,560 (3) Power input Cooling Min. kw 0.440 Nom. kw 1.650 Max. kw 1.930 EER 3.03 Annual energy consumption kwh 825 Energy label Cooling B Piping connections Liquid OD mm 6.35 Gas OD mm 12.7 Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (5) All data mentioned is preliminary information 2-1 Nominal Capacity And Nominal Input FFQ25B8V1B / RKS25J2V1B FFQ35B8V1B / RKS35J2V1B FFQ50B8V1B / RKS50J2V1B Cooling capacity Min. kw 1.3 1.4 0.9 Btu/h 4,400 4,750 3,050 kcal/h 1,110 1,200 770 Nom. kw 2.5 (3) 3.4 (3) 4.7 (3) Btu/h 8,500 (3) 11,600 (3) 16,050 (3) kcal/h 2,150 (3) 2,920 (3) 4,040 (3) Max. kw 3.0 3.7 5.6 Btu/h 10,200 12,600 19,100 kcal/h 2,580 3,180 4,820 Power input Cooling Min. kw 0.30 0.45 Nom. kw 0.83 1.30 1.80 Max. kw 1.10 1.47 2.26 EER 3.01 2.62 2.61 Annual energy consumption kwh 365 550 900 Energy label Cooling A B D Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information Split - Sky Air Outdoor Unit 5

2 Specifications 2-1 Nominal Capacity And Nominal Input FDKS25E7VMB / RKS25J2V1B FDKS35E7VMB / RKS35J2V1B Cooling capacity Min. kw 1.3 (3) 1.4 (3) Btu/h 4,400 (3) 4,800 (3) kcal/h 1,110 (3) 1,200 (3) Nom. kw 2.4 (3) 3.4 (3) Btu/h 8,150 (3) 11,600 (3) kcal/h 2,060 (3) 2,920 (3) Max. kw 3.0 (3) 3.8 (3) Btu/h 10,200 (3) 13,000 (3) kcal/h 2,580 (3) 3,260 (3) Power input Cooling Nom. kw 0.690 1.090 EER 3.48 3.12 Annual energy consumption kwh 345 545 Energy label Cooling A B Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 2-1 Nominal Capacity And Nominal Input FVXS25FV1B / RKS25J2V1B FVXS35FV1B / RKS35J2V1B FVXS50FV1B / RKS50J2V1B Cooling capacity Min. kw 1.3 1.4 Btu/h 4,400 4,800 kcal/h 1,120 1,200 Nom. kw 2.5 (3) 3.5 (3) 5.0 (3) Btu/h 8,500 (3) 11,900 (3) 17,100 (3) kcal/h 2,150 (3) 3,010 (3) 4,300 (3) Max. kw 3.0 3.8 5.6 Btu/h 10,200 13,000 19,100 kcal/h 2,580 3,270 4,820 Power input Cooling Min. kw 0.30 0.50 Nom. kw 0.57 1.02 1.55 Max. kw 0.92 1.25 2.00 EER 4.39 3.43 3.23 Annual energy consumption kwh 285 510 775 Energy label Cooling A Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain OD mm 20.0 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 6 Split - Sky Air Outdoor Unit

2 Specifications 2-1 Nominal Capacity And Nominal Input FLKS25BAVMB / RKS25J2V1B FLKS35BAVMB / RKS35J2V1B FLKS50BAVMB / RKS50J2V1B Cooling capacity Min. kw 1.2 0.9 Btu/h 4,100 3,070 kcal/h 1,030 770 Nom. kw 2.5 (3) 3.5 (3) 4.9 (3) Btu/h 8,500 (3) 11,900 (3) 16,730 (3) kcal/h 2,150 (3) 3,010 (3) 4,210 (3) Max. kw 3.0 3.8 5.3 Btu/h 10,200 13,000 18,090 kcal/h 2,580 3,270 4,560 Power input Cooling Min. kw 0.30 0.45 Nom. kw 0.65 1.13 1.72 Max. kw 0.86 1.26 1.95 EER 3.85 3.10 2.85 Annual energy consumption kwh 325 565 860 Energy label Cooling A B C Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain OD mm 18.0 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 2-2 Technical Specifications RKS20J2V1B RKS25J2V1B RKS35J2V1B RKS42J2V1B RKS50J2V1B Casing Colour Ivory white Dimensions Unit Height mm 550 735 Width mm 765 825 Depth mm 285 300 Packed unit Height mm 612 797 Width mm 906 960 Depth mm 364 390 Weight Unit kg 32 39 47 Packed unit kg 35 45 52 Heat exchanger Length mm 828 810 845 Rows Quantity 1 2 Fin pitch mm 1.4 1.5 1.8 Stages Quantity 24 32 Tube type ø7 Hi-XA ø8 Hi-XA Fin Type Waffle louvered fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller fan Air flow rate Cooling High m³/min 36.2 33.5 36.0 37.3 50.9 cfm 1,278 1,183 1,271 1,317 1,797 Super m³/min 32.7 30.1 30.6 48.9 low cfm 1,155 1,063 1,080 1,727 Heating Super m³/min - low cfm - Fan motor Model D23H-28 D50R-28 KFD-380-50-8C Output W 23 50 53 Speed Cooling High rpm 860 920 890 780 Super low rpm 780 790 670 Heating Super low rpm - Sound power level Cooling High dba 61 63 Split - Sky Air Outdoor Unit 7

2 Specifications 2-2 Technical Specifications RKS20J2V1B RKS25J2V1B RKS35J2V1B RKS42J2V1B RKS50J2V1B Sound pressure level Cooling High dba 46 48 Silent operation dba 43 44 Compressor Model 1YC23AEXD 2YC36BXD Type Hermetically sealed swing compressor Output W 600 1,100 Operation range Cooling Ambien Min. ºCDB -10 t Max. ºCDB 46 Refrigerant Type R-410A Charge kg 0.8 1.0 1.2 1.3 1.7 Refrigerant oil Type FVC50K Charged volume l 0.375 0.65 Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 12.7 Drain Type Hole ID mm 15.9 Piping length OU - IU Max. m 20 30 Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) Level difference IU - OU Max. m 15 20 2-3 Electrical Specifications RKS20J2V1B RKS25J2V1B RKS35J2V1B RKS42J2V1B RKS50J2V1B Power supply Phase 1~ Frequency Hz 50 Voltage V 220-240 Current Nominal running Cooling A 2.5 (1) 2.4 (2) 2.3 3.0 (1) 2.8 (2) 2.7 4.3 (1) 4.1 (2) 3.9 6.0 (1) 5.7 (2) 5.5 6.7 (1) 6.4 (2) 6.1 current (RLA) (3) (3) (3) (3) (3) Starting current Cooling A 2.6 3.1 4.4 6.1 6.8 Wiring connections For power supply Quantity 3 For connection with Quantity 4 indoor Remark Earth wire included Notes (1) 220V (2) 240V 8 Split - Sky Air Outdoor Unit

3 Electrical data 3-1 Electrical Data FTKS20J2V1B + RKS20J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 2.1 FTXS20J2V1B RKS20J2V1B 50-230 9.75 10 34 2.0 23 0.23 23 0.15 50-240 1.9 1. RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D055006D RKS25J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 2.6 FTXS25J2V1B RKS25J2V1B 50-230 9.75 10 45 2.4 23 0.23 23 0.15 50-240 2.3 3.0 FVXS25FV1B RKS25J2V1B 50-230 9.75 10 46 2.8 23 0.23 48 0.05 50-240 2.7 2.4 FFQ25B8V1B RKS25J2V1B 50-230 9.75 10 46 2.3 23 0.23 55 0.60 50-240 2.1 2.7 FLKS25BAVMB RKS25J2V1B 50-230 9.75 10 46 2.5 23 0.23 34 0.34 50-240 2.4 2.5 FDKS25E7VMB RKS25J2V1B 50-230 9.75 10 46 2.4 23 0.23 62 0.50 50-240 2.2 1. RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D070944 Split - Sky Air Outdoor Unit 9

3 Electrical data 3-1 Electrical Data RKS35J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 3.9 FTXS35J2V1B RKS35J2V1B 50-230 9.75 10 65 3.7 23 0.23 23 0.15 50-240 3.5 4.8 FVXS35FV1B RKS35J2V1B 50-230 9.75 10 66 4.6 23 0.23 48 0.05 50-240 4.4 4.3 FFQ35B8V1B RKS35J2V1B 50-230 9.75 10 66 4.1 23 0.23 55 0.60 50-240 3.9 4.3 FHQ35BVV1B RKS35J2V1B 50-230 9.75 10 66 4.1 23 0.23 62 0.60 50-240 3.9 4.4 FBQ35C7VEB RKS35J2V1B 50-230 9.75 10 66 4.2 23 0.23 65 0.50 50-240 4.0 4.5 FLKS35BAVMB RKS35J2V1B 50-230 9.75 10 66 4.3 23 0.23 34 0.38 50-240 4.1 4.4 FDKS35E7VMB RKS35J2V1B 50-230 9.75 10 66 4.2 23 0.23 62 0.50 50-240 4.0 1. RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D070943 FTXS42J2V1B + RKS42J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 5.6 FTXS42J2V1B RKS42J2V1B 50-230 14.75 20 57 5.3 50 0.23 23 0.15 50-240 5.1 1. RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D059709B 10 Split - Sky Air Outdoor Unit

3 Electrical data 3-1 Electrical Data RKS50J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 6.3 FTXS50J2V1B RKS50J2V1B 50-230 19.75 20 66 6.0 53 0.27 23 0.15 50-240 5.7 6.7 FVXS50FV1B RKS50J2V1B 50-230 19.75 120 69 6.3 53 0.27 48 0.10 50-240 6.1 1. RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D070939 Split - Sky Air Outdoor Unit 11

4 Capacity tables 4-1 Cooling Capacity Tables FTXS20J2V1B + RKS20J2V1B COOLING 50Hz 220-240V AFR 9.4 BF 0.14 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 2.05 1.84 0.35 1.96 1.80 0.38 1.86 1.76 0.41 1.83 1.74 0.43 1.77 1.71 0.45 1.68 1.67 0.48 16.0 22 2.14 1.81 0.35 2.05 1.77 0.38 1.95 1.73 0.41 1.92 1.72 0.43 1.86 1.69 0.45 1.77 1.66 0.48 18.0 25 2.23 1.94 0.35 2.14 1.90 0.38 2.05 1.87 0.42 2.01 1.85 0.43 1.95 1.83 0.45 1.86 1.80 0.48 19.0 27 2.28 2.09 0.35 2.19 2.05 0.38 2.09 2.02 0.42 2.06 2.00 0.43 2.00 1.98 0.45 1.91 1.95 0.48 22.0 30 2.42 2.03 0.35 2.32 2.00 0.39 2.23 1.97 0.42 2.19 1.96 0.43 2.14 1.94 0.45 2.05 1.91 0.49 24.0 32 2.51 1.99 0.36 2.42 1.96 0.39 2.32 1.93 0.42 2.29 1.92 0.44 2.23 1.91 0.45 2.14 1.88 0.49 3D070642 SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. FTXS25J2V1B + RKS25J2V1B COOLING 50Hz 220-240V AFR 10.8 BF 0.16 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 2.56 2.18 0.41 2.44 2.13 0.45 2.33 2.08 0.49 2.28 2.05 0.51 2.21 2.02 0.53 2.10 1.97 0.57 16.0 22 2.68 2.15 0.41 2.56 2.10 0.45 2.44 2.05 0.49 2.40 2.03 0.51 2.33 2.00 0.53 2.21 1.95 0.57 18.0 25 2.79 2.29 0.42 2.68 2.24 0.45 2.56 2.20 0.49 2.51 2.18 0.51 2.44 2.15 0.53 2.33 2.10 0.57 19.0 27 2.85 2.45 0.42 2.73 2.41 0.46 2.62 2.36 0.50 2.57 2.34 0.51 2.50 2.32 0.54 2.38 2.27 0.57 22.0 30 3.02 2.38 0.42 2.91 2.34 0.46 2.79 2.30 0.50 2.74 2.28 0.51 2.67 2.26 0.54 2.56 2.22 0.58 24.0 32 3.14 2.33 0.42 3.02 2.29 0.46 2.90 2.26 0.50 2.86 2.24 0.52 2.79 2.22 0.54 2.67 2.19 0.58 3D070647 SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 12 Split - Sky Air Outdoor Unit

4 Capacity tables 4-1 Cooling Capacity Tables FTXS35J2V1B + RKS35J2V1B COOLING 50Hz 220-240V AFR 11.4 BF 0.21 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 3.59 2.67 0.66 3.42 2.59 0.72 3.26 2.51 0.79 3.19 2.48 0.81 3.10 2.43 0.85 2.93 2.35 0.91 16.0 22 3.75 2.63 0.66 3.58 2.55 0.73 3.42 2.48 0.79 3.36 2.45 0.82 3.26 2.40 0.85 3.10 2.33 0.92 18.0 25 3.91 2.75 0.67 3.75 2.68 0.73 3.58 2.61 0.79 3.52 2.58 0.82 3.42 2.54 0.86 3.26 2.47 0.92 19.0 27 3.99 2.91 0.67 3.83 2.84 0.73 3.66 2.77 0.80 3.60 2.74 0.82 3.50 2.70 0.86 3.34 2.64 0.92 22.0 30 4.23 2.80 0.67 4.07 2.74 0.74 3.90 2.68 0.80 3.84 2.66 0.83 3.74 2.62 0.87 3.58 2.57 0.93 24.0 32 4.39 2.73 0.68 4.23 2.67 0.74 4.07 2.62 0.81 4.00 2.60 0.83 3.90 2.57 0.87 3.74 2.51 0.93 3D070669A SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables (figures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. FTXS42J2V1B + RKS42J2V1B COOLING 50Hz 220-240V AFR 11.3 BF 0.14 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20 4.30 3.10 0.93 4.11 3.00 1.02 3.91 2.90 1.11 3.83 2.87 1.14 3.72 2.81 1.20 3.52 2.71 1.29 16.0 22 4.50 3.05 0.93 4.30 2.96 1.02 4.11 2.86 1.11 4.03 2.83 1.15 3.91 2.77 1.20 3.71 2.68 1.29 18.0 25 4.69 3.18 0.94 4.49 3.09 1.03 4.30 3.01 1.12 4.22 2.97 1.15 4.10 2.92 1.21 3.91 2.83 1.30 19.0 27 4.79 3.34 0.94 4.59 3.26 1.03 4.40 3.17 1.12 4.32 3.14 1.16 4.20 3.09 1.21 4.00 3.01 1.30 22.0 30 5.08 3.22 0.95 4.88 3.14 1.04 4.69 3.07 1.13 4.61 3.04 1.16 4.49 2.99 1.22 4.29 2.92 1.31 24.0 32 5.27 3.13 0.96 5.07 3.06 1.04 4.88 2.99 1.13 4.80 2.96 1.17 4.68 2.92 1.22 4.49 2.86 1.31 3D070645 SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. Split - Sky Air Outdoor Unit 13

4 Capacity tables 4-1 Cooling Capacity Tables FTXS50J2V1B + RKS50J2V1B COOLING 50Hz 220-240V AFR 11.6 BF 0.18 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 30 32 35 40 C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14.0 20.0 4.62 3.26 1.07 4.62 3.26 1.20 4.62 3.26 1.33 4.56 3.22 1.38 4.42 3.15 1.44 4.19 3.03 1.55 16.0 22.0 5.35 3.47 1.13 5.12 3.34 1.23 4.89 3.23 1.34 4.79 3.18 1.39 4.65 3.11 1.45 4.42 3.00 1.56 18.0 25.0 5.58 3.58 1.13 5.35 3.47 1.24 5.12 3.36 1.35 5.02 3.31 1.39 4.88 3.25 1.46 4.65 3.14 1.56 19.0 27.0 5.70 3.73 1.14 5.47 3.62 1.24 5.23 3.51 1.35 5.14 3.47 1.40 5.00 3.41 1.46 4.77 3.31 1.57 22.0 30.0 6.04 3.58 1.15 5.81 3.48 1.25 5.58 3.39 1.36 5.49 3.35 1.40 5.35 3.30 1.47 5.11 3.20 1.58 24.0 32.0 6.27 3.47 1.15 6.04 3.38 1.26 5.81 3.30 1.37 5.72 3.26 1.41 5.58 3.21 1.48 5.34 3.13 1.58 3D070730 SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 14 Split - Sky Air Outdoor Unit

5 Dimensional drawings 5-1 Dimensional Drawings RKS20-42J2V1B Drain outlet (I.D Ø 15.9 hose for connection) 4-holes for anchor bolts (M8 or M10) Minimum space for air passage Wall height on air outlet side = less than 1200 Handle Brand name label Manufacture s label Liquid stop valve (Ø 6.4CuT) Outdoor air thermistor Wiring inlet Service port In case of removing stop valve cover Gas stop valve (Ø 9.5CuT) 3D055546C RKS50J2V1B Drain outlet (I.D. Ø 15.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than 1200 4-holes for anchor bolts (M8 or M10) Brand name label Name plate Wiring inlet In case of removing stop valve cover Terminal strip with earth terminal Outdoor air temperature thermistor Liquid stop valve (Ø 6.4CuT) Service port Gas stop valve (Ø 12.7CuT) 3D051657Q Split - Sky Air Outdoor Unit 15

6 Centre of gravity 6-1 Centre of Gravity RKS20-35J2V1B 4D056351R RKS42J2V1B 4D059009E 16 Split - Sky Air Outdoor Unit

6 Centre of gravity 6-1 Centre of Gravity Split - Sky Air Outdoor Unit 17

7 Piping diagrams 7-1 Piping Diagrams RKS20J2V1B 7.0 CuT Heat exchanger Outdoor temperature thermistor 9.5 CuT 7.0 CuT Heat exchanger thermistor 7.0 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve normally: off 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling 3D059588B RKS25-35J2V1B 7.0 CuT Heat exchanger Outdoor temperature thermistor 9.5 CuT 7.0 CuT Heat exchanger thermistor 4.8 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve normally: off 4.8 CuT 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling 3D059589D 18 Split - Sky Air Outdoor Unit

7 Piping diagrams 7-1 Piping Diagrams RKS42J2V1B Heat exchanger Outdoor temperature thermistor 12.7 CuT Heat exchanger thermistor 4.8 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve normally: off 4.8 CuT 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling 3D059591A RKS50J2V1B 12.7 CuT Heat exchanger thermistor Heat exchanger Outdoor air temperature thermistor 4.0 CuT 4.0 CuT 4.0 CuT 4.0 CuT Capillary tube 1 Capillary tube 2 Capillary tube 3 Capillary tube 4 Muffl er with fi lter 6.4 CuT 6.4 CuT Refrigerant fl ow Cooling Propeller fan 6.4 CuT 12.7 CuT 12.7 CuT Muffl er Discharge pipe thermistor Four way valve normally: off 12.7 CuT 12.7 CuT Muffl er 12.7 CuT Motor operated valve Muffl er with fi lter 6.4 CuT Liquid stop valve Field piping (6.4 CuT) 12.7 CuT Field piping Compressor Gas stop valve with service port (12.7 CuT) 3D051636Q Split - Sky Air Outdoor Unit 19

8 Wiring diagrams 8-1 Wiring Diagrams - Single Phase RKS20-35J2V1B FIELD WIRING indoor outdoor C5,C6,C119 : Capacitor DB1, DB2, DB3 : Diode Bridge FU1, FU2, FU3 : Fuse IPM1, IPM2 : Instelligent Power Module L : Live L1 : Coil L1R : Reactor M1C : Compressor Motor M1F : Fan motor MRCW, MR30, MRM10, MRM20 : Magnetic Relay N : Neutral Q1L : Overload Protector PCB1, PCB2, PCB3 : Printed Circuit Board S10, S11, S20, S40, S50, S70, S80, S90, S100, S110 HL3, HN3, X11A, X12A : Connector RKS42J2V1B R1T, R2T, R3T : Thermistor SA1 : Surge Arrester SW1 : Forced operation switch V1, V2, V3 : Varistor X1M : Terminal Strip Y1E : Electronic Expansion Valve Coil Y1R : Reversing Solenoide Valve Coil Z1C, Z2C, Z3C : Ferrite Core : Protective Earth In case of cooling only type (outdoor) (discharge) (condenser) 1. Refer to the nameplate for the power requirements. 2. Size: length 105 x width 185. 3. Refer to purchasing specifi cation AS(Y)303002, unless otherwise specifi ed. 4. This drawing was drawn on CAD system. 3D065704B indoor Power supply outdoor (outdoor) (discharge) (condenser) FIELD WIRING C74, C75,C94, C95 : Capacitor DB1, DB2, DB3 : Diode Bridge FU1, FU2, FU3 : Fuse IPM1 : Instelligent Power Module L : Live L1 : Coil L1R : Reactor M1C : Compressor Motor M1F : Fan motor MRCW, MRM10, MRM20, MR30 : Magnetic Relay N : Neutral PCB1 : Printed Circuit Board Q1L : Overload Protector R1T~R3T : Thermistor SA1 : Surge Arrester Q31 : IGBT V1, V3, V4 : Varistor X1M : Terminal Strip Y1E : Electronic Expansion Valve Coil Z1C, Z2C, Z3C, Z4C : Ferrite Core S20, S40, S70, S80, S90 X11A : Connector : Protective Earth BLK : Black BLU : Blue BRN : Brown GRN : Green ORG : Orange RED : Red WHT : White YLW : Yellow 1. Refer to purchasing specifi cation AS303002, unless otherwise specifi ed. 2. This drawing was drawn on CAD system. 3. The electric wiring diagram label is 3P210678-1. 3D059615A 20 Split - Sky Air Outdoor Unit

8 Wiring diagrams 8-1 Wiring Diagrams - Single Phase RKS50J2V1B Power supply To indoor unit sheet metal indoor FIELD WIRING outdoor (outdoor) (discharge) (condenser) Z1C~Z5C X1M, X2M Y1E V2, V3, V5, V6, V11 SA2 FU1, FU2, FU3 AC1, AC2 U, V, W, X11A, X12A E1, E2 : Ferrite Core : Terminal Strip : Electronic Expansion Valve Coil : Varistor : Surge Arrester : Fuse HR1, HR2 : Connector MRM10, MRM20 MRC/W : Magnetic Relay R1T~R3T : Thermistor S2~S102 LED A L N SW1 SW4 M1C M1F L1R Q1L PM1 PCB1, 2 Steel metal : Connector : Pilot lamp : Live : Neutral : Forced operation on/off SW (SW1) : Localsetting SW (SW4) : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Terminal strip fi xed plate 1. Refer to purchasing specification AS303002, unless otherwise specifi ed. 2. This drawing was drawn on CAD system. 3. The electric wiring diagram label is 3P193830-1. 3D056145B Split - Sky Air Outdoor Unit 21

9 Sound data 9-1 Sound Pressure Spectrum - Cooling RKS20-25J2V1B RKS35J2V1B Octave band sound pressure level db (0dB = 0.0002 bar) Octave band sound pressure level db (0dB = 0.0002 bar) Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency (Hz) 4D059600B Octave band center frequency (Hz) 4D059594B 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC9612 50 Hz Scale 220~240V (H) A 46 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC9612 50 Hz Scale 220~240V (H) A 48 RKS42J2V1B RKS50J2V1B Octave band sound pressure level db (0dB = 0.0002 bar) Octave band sound pressure level db (0dB = 0.0002 bar) Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency (Hz) 4D059598A Octave band center frequency (Hz) 4D059739A 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC9612 50 Hz Scale 220~240V (H) A 48 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC9612 50 Hz Scale 220~240V (H) A 48 22 Split - Sky Air Outdoor Unit

10 Operation range 10-1 Operation Range RKS20-50J2V1B Outdoor temperature ( cdb) Continuous operation Pull-down period 1. The graph is based on the following conditions. Equivalent piping length 7.5 m Level difference 0 m Air fl ow rate High Indoor temperature ( cwb) 4D029297W Split - Sky Air Outdoor Unit 23

Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Multi units are Eurovent certified for combinations up to 2 indoor units The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN11-100 CD 01/11 Copyright Daikin The present publication supersedes EEDEN10-100 Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environment is set in the EMAS and ISO 14001 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende